910 resultados para Bus stops.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The management and coordination of business-process collaboration experiences changes because of globalization, specialization, and innovation. Service-oriented computing (SOC) is a means towards businessprocess automation and recently, many industry standards emerged to become part of the service-oriented architecture (SOA) stack. In a globalized world, organizations face new challenges for setting up and carrying out collaborations in semi-automating ecosystems for business services. For being efficient and effective, many companies express their services electronically in what we term business-process as a service (BPaaS). Companies then source BPaaS on the fly from third parties if they are not able to create all service-value inhouse because of reasons such as lack of reasoures, lack of know-how, cost- and time-reduction needs. Thus, a need emerges for BPaaS-HUBs that not only store service offers and requests together with information about their issuing organizations and assigned owners, but that also allow an evaluation of trust and reputation in an anonymized electronic service marketplace. In this paper, we analyze the requirements, design architecture and system behavior of such a BPaaS-HUB to enable a fast setup and enactment of business-process collaboration. Moving into a cloud-computing setting, the results of this paper allow system designers to quickly evaluate which services they need for instantiationg the BPaaS-HUB architecture. Furthermore, the results also show what the protocol of a backbone service bus is that allows a communication between services that implement the BPaaS-HUB. Finally, the paper analyzes where an instantiation must assign additional computing resources vor the avoidance of performance bottlenecks.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper proposes a method of designing fixed parameter decentralized power system stabilizers (PSS) for interconnected multi-machine power systems. Conventional design technique using a single machine infinite bus approximation involves the frequency response estimation called the GEP(s) between the AVR input and the resultant electrical torque. This requires the knowledge of equivalent external reactance and infinite bus voltage or their estimated values at each machine. Other design techniques using P-Vr characteristics or residues are based on complete system information. In the proposed method, information available at the high voltage bus of the step-up transformer is used to set up a modified Heffron-Phillip's model. With this model it is possible to decide the structure of the PSS compensator and tune its parameters at each machine in the multi-machine environment, using only those signals that are available at the generating station. The efficacy of the proposed design technique has been evaluated on three of the most widely used test systems. The simulation results have shown that the performance of the proposed stabilizer is comparable to that which could be obtained by conventional design but without the need for the estimation and computation of external system parameters.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Thermal decomposition of ethylene diamine diperchlorate (EDDP) has been studied by differential-thermal analysis (DTA), thermogravimetric analysis (TGA), isothermal weight-loss measurements and mass-spectrometric analysis of the decomposition products. It has been observed that EDDP decomposes in two temperature regions. The low-temperature decomposition stops at about 35 to 40 percent weight loss below 250°C. The reason for the low-temperature cessation may be the adsorption of excess ethylene diamine on the crystal surface of EDDP. An overall activation energy of 54 kcal per mole has been calculated for the thermal decomposition of EDDP. Mass-spectrometric analysis shows that the decomposition products are mainly CO2, H2O, HCl and N2. The following stoichiometry has been proposed for the thermal decomposition of EDDP: (−CH2NH3CIO4)2→2CO2O+2HCl+N2

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to examine the applicability of the Phonological Mean Length of Utterance (pMLU) method to the data of children acquiring Finnish, for both typically developing children and children with a Specific Language Impairment (SLI). Study I examined typically developing children at the end of the one-word stage (N=17, mean age 1;8), and Study II analysed children s (N=5) productions in a follow-up study with four assessment points (ages 2;0, 2;6, 3;0, 3;6). Study III was carried out in the form of a review article that examined recent research on the phonological development of children acquiring Finnish and compared the results with general trends and cross-linguistic findings in phonological development. Study IV included children with SLI (N=4, mean age 4;10) and age-matched peers. The analyses in Studies I, II and IV were made using the quantitative pMLU method. In the pMLU method, pMLU values are counted for both the words that the children targeted (so-called target words) and the words produced by the children. When the child s average pMLU value was divided with the average target word pMLU value, it is possible to examine that child s accuracy in producing the words with the Whole-Word Proximity (PWP) value. In addition, the number of entirely correctly produced words is counted to obtain the Whole-Word Correctness (PWC) value. Qualitative analyses were carried out in order to examine how the children s phoneme inventories and deficiencies in phonotactics would explain the observed pMLU, PWP and PWC values. The results showed that the pMLU values for children acquiring Finnish were relatively high already at the end of the one-word stage (Study I). The values were found to reflect the characteristics of the ambient language. Typological features that lead to cross-linguistic differences in pMLU values were also observed in the review article (Study III), which noted that in the course of phonological acquisition there are a large number of language-specific phenomena and processes. Study II indicated that overall the children s phonological development during the follow-up period was reflected in the pMLU, PWP and PWC values, although the method showed limitations in detecting qualitative differences between the children. Correct vowels were not scored in the pMLU counts, which led to some misleadingly high pMLU and PWP results: vowel errors were only reflected in the PWC values. Typically developing children in Study II reached the highest possible pMLU results already around age 3;6. At the same time, the differences between the children with SLI and age-matched peers in the pMLU values were very prominent (Study IV). The values for the children with SLI were similar to the ones reported for two-year-old children. Qualitative analyses revealed that the phonologies of the children with SLI largely resembled the ones of younger, typically developing children. However, unusual errors were also witnessed (e.g., vowel errors, omissions of word-initial stops, consonants added to the initial position in words beginning with a vowel). This dissertation provides an application of a new tool for quantitative phonological assessment and analysis in children acquiring Finnish. The preliminary results suggest that, with some modifications, the pMLU method can be used to assess children s phonological development and that it has some advantages compared to the earlier, segment-oriented approaches. Qualitative analyses complemented the pMLU s observations on the children s phonologies. More research is needed in order to verify the levels of the pMLU, PWP and PWC values in children acquiring Finnish.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Neutral point clamped (NPC), three level converters with insulated gate bipolar transistor devices are very popular in medium voltage, high power applications. DC bus short circuit protection is usually done, using the sensed voltage across collector and emitter (i.e., V-CE sensing), of all the devices in a leg. This feature is accommodated with the conventional gate drive circuits used in the two level converters. The similar gate drive circuit, when adopted for NPC three level converter protection, leads to false V-CE fault signals for inner devices of the leg. The paper explains the detailed circuit behavior and reasons, which result in the occurrence of such false V-CE fault signals. This paper also illustrates that such a phenomenon shows dependence on the power factor of the supplied three-phase load. Finally, experimental results are presented to support the analysis. It is shown that the problem can be avoided by blocking out the V-CE sense fault signals of the inner devices of the leg.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper we present a cache coherence protocol for multistage interconnection network (MIN)-based multiprocessors with two distinct private caches: private-blocks caches (PCache) containing blocks private to a process and shared-blocks caches (SCache) containing data accessible by all processes. The architecture is extended by a coherence control bus connecting all shared-block cache controllers. Timing problems due to variable transit delays through the MIN are dealt with by introducing Transient states in the proposed cache coherence protocol. The impact of the coherence protocol on system performance is evaluated through a performance study of three phases. Assuming homogeneity of all nodes, a single-node queuing model (phase 3) is developed to analyze system performance. This model is solved for processor and coherence bus utilizations using the mean value analysis (MVA) technique with shared-blocks steady state probabilities (phase 1) and communication delays (phase 2) as input parameters. The performance of our system is compared to that of a system with an equivalent-sized unified cache and with a multiprocessor implementing a directory-based coherence protocol. System performance measures are verified through simulation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The amount of reactive power margin available in a system determines its proximity to voltage instability under normal and emergency conditions. More the reactive power margin, better is the systems security and vice-versa. A hypothetical way of improving the reactive margin of a synchronous generator is to reduce the real power generation within its mega volt-ampere (MVA) ratings. This real power generation reduction will affect its power contract agreements entered in the electricity market. Owing to this, the benefit that the generator foregoes will have to be compensated by paying them some lost opportunity cost. The objective of this study is three fold. Firstly, the reactive power margins of the generators are evaluated. Secondly, they are improved using a reactive power optimization technique and optimally placed unified power flow controllers. Thirdly, the reactive power capacity exchanges along the tie-lines are evaluated under base case and improved conditions. A detailed analysis of all the reactive power sources and sinks scattered throughout the network is carried out in the study. Studies are carried out on a real life, three zone, 72-bus equivalent Indian southern grid considering normal and contingency conditions with base case operating point and optimised results presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents the analysis and study of voltage collapse at any converter bus in A C-DC systems considering the dynamics of DC system. The problem of voltage instability is acute when HVDC links are connected to weak AC systems, the strength determined by short circuit ratio (SCR) at the converter bus. The converter control strategies are important in determining voltage instability. Small signal analysis is used to identify critical modes and evaluate the effect of AC system strength and control parameters. A sample two-terminal DC system is studied and the results compared with those obtained from static analysis. Also, the results obtained from small signal analysis are validated with nonlinear simulation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new design technique for an SVC-based power system damping controller has been proposed. The controller attempts to place all plant poles within a specified region on the s-plane to guarantee the desired closed loop performance. The use of Horowitz's quantitative feedback theory (QFT) permits the design of a 'fixed gain controller' that maintains its performance in spite of large variations in the plant parameters during its normal course of operation. The required controller parameters are arrived at by solving an optimization problem that incorporates the control specifications. The performance of this robust controller has been evaluated on a single machine infinite bus system equipped with a mid point SVC, and the results are shown to be consistent with the expected performance of the stabilizer. (C) 1998 Elsevier Science S.A. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Simulation is an important means of evaluating new microarchitectures. With the invention of multi-core (CMP) platforms, simulators are becoming larger and more complex. However, with the availability of CMPs with larger caches and higher operating frequency, the wall clock time required for simulating an application has become comparatively shorter. Reducing this simulation time further is a great challenge, especially in the case of multi-threaded workload due to indeterminacy introduced due to simultaneously executing various threads. In this paper, we propose a technique for speeding multi-core simulation. The model of the processor core and cache are replaced with functional models, to achieve speedup. A timed Petri net model is used to estimate the execution time of the processor and the memory access latencies are estimated using hit/miss information obtained from the functional model of the cache. This model can be used to predict performance of data parallel applications or multiprogramming workload on CMP platform with various cache hierarchies and shared bus interconnect. The error in estimation of the execution time of an application is within 6%. The speedup achieved ranges between an average of 2x--4x over the cycle accurate simulator.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

With deregulation, the total transfer capability (TTC) calculation, which is the basis for evaluating available transfer capability (ATC), has become very significant. TTC is an important index in power markets with large volume of inter-area power exchanges and wheeling transactions taking place on an hourly basis. Its computation helps to achieve a viable technical and commercial transmission operation. The aim of the paper is to evaluate TTC in the interconnections and also to improve it using reactive optimization technique and UPFC devices. Computations are carried out for normal and contingency cases such as single line, tie line and generator outages. Base and optimized results are presented, and the results show how reactive optimization and unified power flow controller help to improve the system conditions. In this paper repeated power flow method is used to calculate TTC due to its ease of implementation. A case study is carried out on a 205 bus equivalent system, a part of Indian Southern grid. Parameters like voltage magnitude, L-index, minimum singular value and MW losses are computed to analyze the system performance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

When the cold accretion disc coupling between neutral gas and a magnetic field is so weak that the magnetorotational instability is less effective or even stops working, it is of prime interest to investigate the pure hydrodynamic origin of turbulence and transport phenomena. As the Reynolds number increases, the relative importance of the non-linear term in the hydrodynamic equation increases. In an accretion disc where the molecular viscosity is too small, the Reynolds number is large enough for the non-linear term to have new effects. We investigate the scenario of the `weakly non-linear' evolution of the amplitude of the linear mode when the flow is bounded by two parallel walls. The unperturbed flow is similar to the plane Couette flow, but with the Coriolis force included in the hydrodynamic equation. Although there is no exponentially growing eigenmode, because of the self-interaction, the least stable eigenmode will grow in an intermediate phase. Later, this will lead to higher-order non-linearity and plausible turbulence. Although the non-linear term in the hydrodynamic equation is energy-conserving, within the weakly non-linear analysis it is possible to define a lower bound of the energy (alpha A(c)(2), where A(c) is the threshold amplitude) needed for the flow to transform to the turbulent phase. Such an unstable phase is possible only if the Reynolds number >= 10(3-4). The numerical difficulties in obtaining such a large Reynolds number might be the reason for the negative result of numerical simulations on a pure hydrodynamic Keplerian accretion disc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a prototype of a fuzzy system for alleviation of network overloads in the day-to-day operation of power systems. The control used for overload alleviation is real power generation rescheduling. Generation Shift Sensitivity Factors (GSSF) are computed accurately, using a more realistic operational load flow model. Overloading of lines and sensitivity of controlling variables are translated into fuzzy set notations to formulate the relation between overloading of line and controlling ability of generation scheduling. A fuzzy rule based system is formed to select the controllers, their movement direction and step size. Overall sensitivity of line loading to each of the generation is also considered in selecting the controller. Results obtained for network overload alleviation of two modified Indian power networks of 24 bus and 82 bus with line outage contingencies are presented for illustration purposes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper, a wind energy conversion system (WECS) using grid-connected wound rotor induction machine controlled from the rotor side is compared with both fixed speed and variable speed systems using cage rotor induction machine. The comparison is done on the basis of (I) major hardware components required, (II) operating region, and (III) energy output due to a defined wind function using the characteristics of a practical wind turbine. Although a fixed speed system is more simple and reliable, it severely limits the energy output of a wind turbine. In case of variable speed systems, comparison shows that using a wound rotor induction machine of similar rating can significantly enhance energy capture. This comes about due to the ability to operate with rated torque even at supersynchronous speeds; power is then generated out of the rotor as well as the stator. Moreover, with rotor side control, the voltage rating of the power devices and dc bus capacitor bank is reduced. The size of the line side inductor also decreasesd. Results are presented to show the substantial advantages of the doubly fed system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new topology of asymmetric cascaded H-Bridge inverter is presented in this paper It consists of two cascaded H-bridge cells per phase. They are fed from isolated dc sources having a dc bus ratio of 1:0.366. Out of many space vectors possible from this circuit, only those are chosen that lie on 12-sided polygons. Thus, the overall space vector diagram produced by this circuit consists of multiple numbers of 12-sided polygons. With a proper PWM timing calculations based on these selected space vectors, it is possible to eliminate all the 6n +/- 1, (n = odd) harmonics from the phase voltage under all operating conditions. The switching frequency of individual H-Bridge cells is also substantially low. Extensive experimental results have been presented in this paper to validate the proposed concept.