973 resultados para Airflow resistivity


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Evaporative cooling operates using water and air as working fluids. It consists in water evaporation, through the passage of an airflow, thus decreasing the air temperature. This system has a great potential to provide thermal comfort in places where air humidity is low, being, however, less efficient where air humidity is high. A way to solve this problem is to use dehumidifiers to pre-conditioning the process air. This paper presents a system that can be used in humid climates coupling desiccant dehumidification equipment to evaporative coolers. The paper shows, initially, the main characteristics of the evaporative cooling and of the adsorption dehumidification systems. Later on the coupled systems, in which occurs a dehumidification by adsorption in a counter flow rotary heat exchanger following the evaporate cooling of the air in evaporative coolers, are analyzed. The thermodynamic equations of state are also presented. Following, this paper analyzes some operation parameters such as: reactivation temperature, R/P relationship (reactivation air flow/ process air flow) and the thermodynamic conditions of the entering air flow. The paper shows the conditions for the best operation point, with regard to thermal comfort conditions and to the energy used in the process. In addition this paper presents an application of the system in different climate characteristics of several tropical and equatorial cities. Copyright © 2005 by ABCM.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A site investigation program was carried out to detect salt-water intrusions in a shallow sedimentary aquifer based on electrical resistivity measurements. The site is located close to Paranaguá harbor, in the Paraná State, Brasil. At this site, high chloride concentration contaminated shallow water wells used to supply water for local industries. The site investigation program included a fieldwork, dipole-dipole electrical profiling, resistivity piezocone tests, physical-chemical analysis of sampled water and interpretation of borehole logs. The resistivity piezocone tests provided two simultaneous information; the soil stratigraphy at a very detailed level and a quasi-continuous resistivity profile. Both information adequately complemented dipole-dipole electrical profiling test data. The integration of all test data allowed identifying the contaminated areas as well as guided the location of new water wells to be installed in this area.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Chronic obstructive pulmonary disease is progressive and is characterized by abnormal inflammation of the lungs in response to inhalation of noxious particles or toxic gases, especially cigarette smoke. Although this infirmity primarily affects the lungs, diverse extrapulmonary manifestations have been described. The likely mechanisms involved in the local and systemic inflammation seen in this disease include an increase in the number of inflammatory cells (resulting in abnormal production of inflammatory cytokines) and an imbalance between the formation of reactive oxygen species and antioxidant capacity (leading to oxidative stress). Weakened physical condition secondary to airflow limitation can also lead to the development of altered muscle function. Chronic obstructive pulmonary disease presents diverse systemic effects including nutritional depletion and musculoskeletal dysfunction (causing a reduction in exercise tolerance), as well as other effects related to the comorbidities generally observed in these patients. These manifestations have been correlated with survival and overall health status in chronic obstructive pulmonary disease patients. In view of these facts, the aim of this review was to discuss findings in the literature related to the systemic manifestations of chronic obstructive pulmonary disease, emphasizing the role played by systemic inflammation and evaluating various therapeutic strategies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Polycrystalline Nd1-xEuxNiO3 (0≤x≤0.5) compounds were synthesized in order to investigate the character of the metal-insulator (MI) phase transition in this series. Samples were prepared through the sol-gel route and subjected to heat treatments at ∼1000 °C under oxygen pressures as high as 80bar. X-ray diffraction (XRD) and neutron powder diffraction (NPD), electrical resistivity ρ(T), and magnetization M(T) measurements were performed on these compounds. The NPD and XRD results indicated that the samples crystallize in an orthorhombic distorted perovskite structure, space group Pbnm. The analysis of the structural parameters revealed a sudden and small expansion of ∼0.2% of the unit cell volume when electronic localization occurs. This expansion was attributed to a small increase of ∼0.003 of the average Ni-O distance and a simultaneous decrease of ∼-0.5° of the Ni-O-Ni superexchange angle. The ρ(T) measurements revealed a MI transition occurring at temperatures ranging from TMI∼193 to 336K for samples with x ≤ 0 and 0.50, respectively. These measurements also show a large thermal hysteresis in NdNiO3 during heating and cooling processes, suggesting a first-order character of the phase transition at TMI. The width of this thermal hysteresis was found to decrease appreciably for the sample Nd 0.7Eu0.3NiO3. The results indicate that cation disorder associated with increasing substitution of Nd by Eu is responsible for changing the first-order character of the transition in NdNiO3. © 2006 IOP Publishing Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Vertical electrical soundings using eletroresistivity method were carried out in the public waste landfill in Macapá - AP, having as a goal to investigate the geoelectrical and hidrogeologic characteristics of the ground. The results of geophysics interpretation allowed obtaining a model of five geoelectrical layers until the depth of 14,6 m. This model is correlated to a sedimentary sequence of clay-silt-sandy with laterite. The main flow of the water table, also determined, is concordant to the topographical gradient.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The definition of models and base parameters for application of investigation tools in environment with high complexity are a basic premise to any sciences. The geophysics is a science with solid theoretical base and applications in diversified areas of the sciences geological, astronomical, meteorological, among many others. Its application in environmental studies is relatively recent and needs further research. To understand the behavior of resident contaminants in a dynamic and complex environment as the geological, it requests studies in scale laboratorial, under control of factors seasonality variable. This work simulates a leak of gasoline in soil, under conditions and in laboratory scale, with the objective of monitoring the temporary behavior of the hydrocarbon under the optics of variation of the parameter physical electric resistivity. The results indicate increase of the resistivity in recent periods the contamination, followed for stability in the values and finally fall and return tendency to the natural conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Surgical defects of the alar lobule can be difficult to repair with functional and aesthetically desirable results. Skin grafts are smoother and paler than the nasal skin. Flaps from the cheek and proximal nose can bridge the alar crease, resulting in obstruction. The authors describe a technique to repair nasal ala defects, with maintenance of the cosmetic unit, without airflow disturbance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Landfill is an engineering work that aims at to accommodate residues in the smallest possible space in the soil, with minimum damages to the environment and the public health. One in the constructive forms of a controlled landfill is the excavation of ditches with appropriate dimensions, for disposition of solid residues without compactation or impermeabilization. Liquid effluents generated for similar volumes of residues, disposed in ditches with ages different from closing, it should result in physical and chemical alterations you correlated at the time of residence materials. With base in this hypothesis, measures of electric resistivity were accomplished through the of Eletrical Resistivity geophysical method, on residues ditches closed annually between 12/2001 and 12/2007, localized in control landfill of the Cordeirópolis city (SP). The leachate is a liquid effluent generated by the decomposition of organic matter and characterized by high content in total dissolved solids, whose interaction with geological environment results in alterations in terms of electrical resistivity susceptible to detection for the geophysical instrumental. The results suggest a resistivity reduction for leachate percolation produced for ditches recently and increase progressive of the resistivity for older ditches. The statistical comparative analysis with reference values for the area suggests ages of the finish production and percolation leachate for soil and rock below the ditches.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article shows an analysis of the electrical parameters of a three-phase transmission line section using a relatively new design for steel towers characterized by 280 meters high. These main features, the height of the line conductors and distance between them, are intrinsically related to the longitudinal and transversal parameters of the line. By this means, an analysis was carried out in order to show the electrical variations between a transmission line using the new technology and a conventional 440-kV line through a wide range of frequencies and a variable soil resistivity. © 2012 The Institution of Engineering and Technology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The geoelectrical methods have been widely used in research involving the evaluation and monitoring of areas with environmental risk. This paper presents the results of applying the Electrical Resistivity method by electrical profiling technique to investigate the fuel presence in soil and groundwater proceeding in station gas, located in an urban area Caçapava do Sul (RS), on soil in situ, from modification of Caçapava granite. The results suggest an association between low resistivity anomalies zone with potentially degraded from underground tanks worthless on the form of free phase, now represented as residual phase. The results of the model inversion are consistent with the standards expected for hydrocarbons present in the saturated zone. The electrical resistivity method proved to be an important tool for assessment and environmental monitoring in conjunction with direct methods of investigation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Ji-Paraná city (RO) it doesn't possess public system of collection and treatment of sewers, being the waters residuárias produced by the local population thrown at sewages. Traditionally, many inhabitants use wells amazon extracted underground water or tubular shallow in the urban zone. The study accomplished in the Nova Brasília neighborhood for Silva (2009) revealed that the local aquifer is strongly contaminated for nitrate, originated of the decomposition of the organic matter deposited at the sewages local maidservants. With the objective of detecting areas with high concentrations originating from organic compositions of septic sewages, geophysical risings were accomplished, later related with analyses physical-chemistries in samples of groundwaters obtained in several wells installed in the Nova Brasília neighborhood, besides of soil samples descriptions in zone not saturated obtained in wells. The results obtained by the geophysical rehearsals they reveal that the polluting feather not migrates through the zone saturated, arriving with relative easiness to the aquifer, reaching in some points, superior depth to 34 m reached by the geoelectrical profiling.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article shows an analysis of the longitudinal electric parameters of a three-phase transmission line/section using a 280-meter high steel tower. This characteristic, the height of the line conductors and distance between them, are intrinsic related to the longitudinal and transversal parameters of the line. By this means, an accurate study was carried out in order to show the electric variations between a transmission line using the new technology and a three-phase conventional 440 kV line for a wide range of frequencies and a variable soil resistivity. In addition, by using a digital line model, simulations are carried out in time domain to analyze critical overvoltage transients on the studied line. © 2011 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction. In this study we aimed to evaluate the peak cough flow (PCF) in healthy Brazilian subjects. Methods. We evaluated 484 healthy subjects between 18 and 40 years old. Subjects were seated and oriented were asked to perform a maximal inspiration followed by a quick, short and explosive expiration on the peak flow meter. Three measures were carried out and recorded the average of the three results for each individual. Results: The PCF values ranged between 240 and 500 L/min. The PCF values were lower in females than in males. The PCF was inversely proportional to age. Conclusion: The values for Brazilian adult healthy subjects regarding PCF were between 240 and 500 L/min. © 2012 Cardoso et al.; licensee BioMed Central Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Several factors have contributed to the increase the world production of urban solid waste, resulting in difficulties to the correct management and the final environmentally appropriate disposal, in addition to causing serious socio-economic, environmental, and public health troubles. The soil and groundwater contamination by leachate in waste disposal sites is almost always present, leveraging the emergence and/or adaptation of methodologies for environmental assessment of these areas. The geophysical methods, especially the electrical resistivity method, are fast, reliable and low-cost alternative for this purpose. This paper reports the methodology adopted for the temporal monitoring of the plume of contamination of controlled landfill in the municipality of Rio Claro (SP). Electrical resistivity data were obtained in 1999 and 2008, by the resistivity method, using the techniques of vertical electrical sounding and electrical profile. In both years, similar tests were carried out in the same locations within the disposal area. The results indicated that the plume of contamination has resistivity values less than or equal to 50 ohm.m and moves guided by 2 flows: the main, to the southeast, and the secondary, to the west. Relatively to the first series of tests in 1999, the plume of contamination was higher and deeper in 2008, contrary to what was expected for a landfill deactivated for at least 10 years.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The mineral exploration is a complex activity that should involve a combination of direct and indirect techniques of geological investigation. The growing demand for base metals in the national and international market provides the revaluation of mineral occurrences that can become deposits and mines. This paper presents the results of the electrical resistivity and induced polarization geophysical methods in azimuthal arrangement, applied in a mineral occurrence of disseminated copper sulfides, previously studied through trenches and core drilling, located in the Camaquã Sedimentary Basin, Rio Grande do Sul State, Brazil. The inversion models indicate the coincidence of high chargeability and low resistivity values. The integration of geophysical data permitted the elaboration of 3D attributes visualization models for the mineralization enclosed in volcanic tuffs. The integrated geophysical and geological analysis indicates the potential of a new mineralized area. © 2012 Sociedade Brasileira de Geofísica.