861 resultados para 390404 Detection and Prevention of Crime


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Toxoplasma gondii and Neospora caninum are related Apicomplexa parasites responsible for systemic diseases in many species of animals, including dogs. Methods: This study aimed to determine the occurrence of T. gondii and N. caninum infections in 50 dogs with neurological signs that were admitted to the Veterinary Hospital of Universidade Estadual Paulista, City of Botucatu, Brazil. All animals were screened for antibodies using an immunofluorescent antibody test for both parasites. Tissues of positive animals were bioassayed in mice (T. gondii) and gerbils (N. caninum), and DNA was analyzed using the polymerase chain reaction (PCR). Positive samples for T. gondii by PCR were typed using restriction fragment length polymorphism-PCR for 11 markers: SAG1, SAG2 (5'-3'-SAG2 and alt.SAG2), SAG3, Btub, GRA6, L358, c22-8, c29-6, PK1 and Apico, and CS3 marker for virulence analysis. Results: Specific antibodies were detected in 11/50 (22%; 95% confidence interval (CI95%), 12.8-35.3%) animals for T. gondii and 7/50 (14%; CI95%, 7.02-26.3%) for N. caninum. In the bioassay and PCR, 7/11 (63.6%; CI95%, 34.9-84.8%) samples were positive for T. gondii and 3/7 (42.9%; CI95% I, 15.7-75.5%) samples were positive for N. caninum. Three different genotypes were identified, but only 1 was unique. Conclusions: These data confirm the presence of T. gondii and N. caninum in dogs from Brazil, indicating the importance of this host as a sentinel of T. gondii for human beings, and the genotypic variation of this parasite in Brazil.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives:The aim of this in vitro study was to assess the inter- and intra-examiner reproducibility and the accuracy of the International Caries Detection and Assessment System-II (ICDAS-II) in detecting occlusal caries.Methods:One hundred and sixty-three molars were independently assessed twice by two experienced dentists using the 0- to 6-graded ICDAS-II. The teeth were histologically prepared and classified using two different histological systems [Ekstrand et al. (1997) Caries Research vol. 31, pp. 224-231; Lussi et al. (1999) Caries Research vol. 33, pp. 261-266] and assessed for caries extension. Sensitivity, specificity, accuracy and area under the ROC curve (A(z)) were obtained at D(2) and D(3) thresholds. Unweighted kappa coefficient was used to assess inter- and intra-examiner reproducibility.Results:For the Ekstrand et al. histological classification the sensitivity was 0.99 and 1.00, specificity 1.00 and 0.69 and accuracy 0.99 and 0.76 at D(2) and D(3), respectively. For the Lussi et al. histological classification the sensitivity was 0.91 and 0.75, specificity 0.47 and 0.62 and accuracy 0.86 and 0.68 at D(2) and D(3), respectively. The A(z) varied from 0.54 to 0.73. The inter- and intra-examiner kappa values were 0.51 and 0.58, respectively.Conclusions:ICDAS-II presented good reproducibility and accuracy in detecting occlusal caries, especially caries lesions in the outer half of the enamel.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work deals with noise removal by the use of an edge preserving method whose parameters are automatically estimated, for any application, by simply providing information about the standard deviation noise level we wish to eliminate. The desired noiseless image u(x), in a Partial Differential Equation based model, can be viewed as the solution of an evolutionary differential equation u t(x) = F(u xx, u x, u, x, t) which means that the true solution will be reached when t ® ¥. In practical applications we should stop the time ''t'' at some moment during this evolutionary process. This work presents a sufficient condition, related to time t and to the standard deviation s of the noise we desire to remove, which gives a constant T such that u(x, T) is a good approximation of u(x). The approach here focused on edge preservation during the noise elimination process as its main characteristic. The balance between edge points and interior points is carried out by a function g which depends on the initial noisy image u(x, t0), the standard deviation of the noise we want to eliminate and a constant k. The k parameter estimation is also presented in this work therefore making, the proposed model automatic. The model's feasibility and the choice of the optimal time scale is evident through out the various experimental results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

No ano agrícola de 2000/2001, ocorreu um surto de nanismo e necrose da haste em soja (Glycine max) plantada em duas áreas do Brasil Central e na safra seguinte, esta anomalia foi constatada em outras regiões produtoras, mesmo distantes mais de 2.000 km de onde fora inicialmente constatada. Estudos envolvendo ensaios de transmissão (enxertia, mecânica e insetos vetores), microscopia eletrônica, purificação, sorologia e ensaios moleculares indicaram que a enfermidade foi causada por um carlavirus transmitido por mosca branca, possivelmente relacionado ao Cowpea mild mottle virus (CpMMV).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Procion red HE-3B (RR120) is an example of dye currently used in affinity purification. A method is described for determining trace amounts of RR120 dye contaminant in human serum albumin by cathodic stripping voltammetry. The method is based on a measure of a well-defined peak at -0.58 V, obtained when samples of HSA protein (0.01-2% w/v) containing dye concentrations are submitted to a heating time of 330 min at 80degreesC in NaOH, pH 12.0 and the samples are removed to a solution containing Britton-Robinson buffer, pH 4.0. Using an optimum accumulation potential and tune of 0 V and 240 s, respectively, linear calibration curves were obtained from 1.0 X 10(-9) to 1.0 X 10(-8) mol 1(-1) for RR120 dye. Leakage/hydrolysis of reactive red 120 from an agarose support (e.g. at pH 2 or 12) can also be conveniently determined at very low levels (sub-mug ml(-1)) by means of cathodic stripping voltammetry, which involves adsorptive accumulation of the dye onto the hanging mercury-drop electrode. (C) 2002 Elsevier B.V. B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two simple methods were developed to determine, 11 pesticides in coconut water, a natural isotonic drink rich in salts, sugars and vitamins consumed by the people and athletes. The first procedure involves solid-phase extraction using Sep-Pak Vac C-18 disposable cartridges with methanol for elution. Isocratic analysis was carried out by means of high-performance liquid chromatography with ultraviolet detection at 254 nm to analyse captan, chlorothalonil, carbendazim, lufenuron and diafenthiuron. The other procedure is based on liquid-liquid extraction with hexane-dichloromethane (1:1, v/v), followed by gas chromatographic analysis with effluent splitting to electron-capture detection for determination of endosulfan, captan, tetradifon and trichlorfon and thermionic specific detection for determination of malathion, parathion-methyl and monocrotophos. The methods were validated with fortified samples at different concentration levels (0.01-12.0 mg/kg). Average recoveries ranged from 75 to 104% with relative standard deviations between 1.4 and 11.5%. Each recovery analysis was repeated at least five times. Limits of detection ranged from 0.002 to 2.0 mg/kg. The analytical procedures were applied to 15 samples and no detectable amounts of the pesticides were found in any samples under the conditions described. (C) 2002 Elsevier B.V. B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A fast, simple, non-destructive method for the direct screening of polycyclic aromatic hydrocarbons (PAHs) in vegetable oil samples is proposed. The method uses a supercritical fluid extraction (SFE) system coupled on-line with a fluorimetric detector to determine PAHs. This special assembly avoids the main problems encountered in the determination of PAHs in complex matrices such as vegetable oils. PAHs are selectively extracted by using silica gel in the thimble and cleaned up by passage through a C18 column. Interferences are preferentially retained by the silica gel during the SFE process while PAHs are adsorbed in the C18 column and the remainder of the matrix is sent to waste. Finally, the C18 column is purged to remove residual CO2 gas and adsorbed PAHs are recovered by desorption with a solvent. The extracts from positive samples are subsequently analyzed by liquid chromatography (LC) with fluorescence detection. The proposed method allows the confirmation of vegetable oil safety and hence provides a new tool for consumer protection. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective-To develop and apply the liquid-phase blocking sandwich ELISA (BLOCKING-ELISA) for the quantification of antibodies against foot-and-mouth disease virus (FMDV) strains O-1 Campos, A(24) Cruzeiro, and C-3 Indaial.Design-Antibody quantification.Sample Population-158 water buffalo from various premises of São Paulo Stale-Brazil. The sera were collected either from systemically vaccinated or nonvaccinated animals.Procedure-The basic reagents of BLOCKING-ELISA (capture and detector antibodies, virus antigens, and conjugate) were prepared and the reaction was optimized and standardized to quantify water buffalo antibodies against FMDV. An alternative procedure based on mathematical interpolation was adopted to estimate more precisely the antibody 50% competition liters in the BLOCKING-ELISA. These titers were compared with the virus-neutralization test (VNT) titers to determine the correlation between these techniques. The percentages of agreement, cutoff points, and reproducibility also were determined.Results-The antibody liters obtained in the BLOCKING-ELISA had high positive correlation coefficients with VNT, reaching values of 0.90 for O-1 Campos and C-3 Indaial, and 0.82 for the A(24) Cruzeiro (P < 0.0005). The cutoff points obtained by use of the copositivity and conegativity curves allowed determination of high levels of agreement between BLOCKLNG-ELISA and VNT antibody titers against the 3 FMDV strains analyzed.Conclusions-The results characterized by high cor relation coefficients, levels of agreement, and reproducibility indicate that the BLOCKING-ELISA may replace the conventional VNT for detection and quantification of antibodies from water buffalo sera to FMDV.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Organotin compounds, largely used as biocides in antifouling paints, are among the most toxic materials introduced into the aquatic environment. Sensitive analytical methods are thus required to characterize their occurrence in environmental and biological matrices. The comparison between two different photometric detectors in terms of analytical performance was carried out for the analysis of organotin compounds. A flame photometric detector (FPD) and a pulsed flame photometric detector (PFPD) were optimized. Their respective sensitivity, linearity range and selectivity were evaluated. Limits of detection obtained for a tributyltin compound (TBT) were 5.0 and 0.9 pg (as Sn) for the FPD and PFPD, respectively, using a 390 nm filter. The PFPD showed higher selectivity, besides reduced gas consumption in the flame, and is very attractive for organotin compound speciation in complex environmental matrices.