971 resultados para wooden poles
Resumo:
In recent years, international cooperation processes have become a key mechanism for companies to internationalise their innovative activities, par ticularly in the case of small businesses whose size reduces their possibilities of developing internationalisation strategies autonomously in the same way as larger companies. In Spain, the existence of two parallel programmes with similar structures oriented towards Europe (EUREKA) and Latin America (IBEROEKA) raises the question as to whether the fact that companies participate in only one (unipolar) or both (bipolar) of these programmes is the result of a selection process, which, in turn, results in the existence of different collectives with different efficiency parameters. The aim of this study is to provide a comparative analysis based on the final reports of Spanish companies that have participated in the EUREKA programme. Two groups of companies were compared: one comprising companies that have only had international experience in Europe (EUREKA); and another formed by companies that have also carried out IBEROEKA projects. The conclusions confirm that the behaviour of both groups of companies differs substantially and reveal the importance of geographical perspective in the analysis of international cooperation in technology. This disparate behaviour is a relevant aspect that must be taken into account when designing policies to promote international technological cooperation.
Resumo:
This study analyses the differences between two calculation models for guardrails on building sites that use wooden boards and tubular steel posts. Wood was considered an isotropic material in one model and an orthotropic material in a second model. The elastic constants of the wood were obtained with ultrasound. Frequencies and vibration modes were obtained for both models through linear analysis using the finite element method. The two models were experimentally calibrated through operational modal analysis. The results obtained show that for the three types of wood under analysis, the model which considered them as an orthotropic material fitted the experimental results better than the model which considered them as an isotropic material.
Resumo:
The paper presents the analysis of an important historical building: the Saint James Theater in the city of Corfù (Greece) actually used as the Municipality House. The building, located in the center of the city, is made of carves stones and is characterized by a stocky shape and by the presence of wooden floors. The study deals with the structural identification of such structure through the analysis of its ambient vibrations recorded by means of accelerometers with high accuracy. A full dynamic testing was developed using ambient vibrations to identify the main modal parameters and to make a non-destructive characterization of this building. The results of these dynamic tests are compared with the modal analysis of a complex finite element (FE) simulation of the structure. This analysis may present several problems and uncertainties for this stocky building. Due to the presence of wooden floors, the local modes can be highly excited and, as a consequence, the evaluation of the structural modal parameters presents some difficulties.
Resumo:
The wooden cellular slabs are lightweight structures, easy to assemble, and with excellent architectural features, as thermal and acoustic conditions. The wooden cellular slabs with perforations are typical and very common engineering solutions, used in the ceiling or flooring plates to improve the acoustic absorption of compartments, and also have a good insulation and relevant architectonic characteristics. However, the high vulnerability of wooden elements submitted to fire conditions requires the evaluation of its structural behavior with accurately. The main objective of this work is to present a numerical model to assess the fire resistance of wooden cellular slabs with different perforations. Also the thermal behavior of the wooden slabs will be compared considering material insulation inside the cavities
Resumo:
Wood is a natural and traditional building material, as popular today as ever, and presents advantages. Physically, wood is strong and stiff, but compared with other materials like steel is light and flexible. Wood material can absorb sound very effectively and it is a relatively good heat insulator. But dry wood burns quite easily and produces a great deal of heat energy. The main disadvantage is the high level of combustion when exposed to fire, where the point at which it catches fire is from 200–400°C. After fire exposure, is need to determine if the charred wooden structures are safe for future use. Design methods require the use of computer modelling to predict the fire exposure and the capacity of structures to resist those action. Also, large or small scale experimental tests are necessary to calibrate and verify the numerical models. The thermal model is essential for wood structures exposed to fire, because predicts the charring rate as a function of fire exposure. The charring rate calculation of most structural wood elements allows simple calculations, but is more complicated for situations where the fire exposure is non-standard and in wood elements protected with other materials. In this work, the authors present different case studies using numerical models, that will help professionals analysing woods elements and the type of information needed to decide whether the charred structures are adequate or not to use. Different thermal models representing wooden cellular slabs, used in building construction for ceiling or flooring compartments, will be analysed and submitted to different fire scenarios (with the standard fire curve exposure). The same numerical models, considering insulation material inside the wooden cellular slabs, will be tested to compare and determine the fire time resistance and the charring rate calculation.
Resumo:
Wood is a natural and traditional building material, as popular today as ever, and presents advantages. Physically, wood is strong and stiff, but compared with other materiais like steel is light and flexible. Wood material can absorb sound very effectively and it is a relatively good heat insulator. But dry wood does bum quite easily md produces a great deal ofheat energy. The main disadvantage is the high levei ofcombustion when exposed to fíre, where the point at which it catches fire is fi-om 200-400°C. After fu-e exposure, is need to determine if the charred wooden stmctures are safe for future use. Design methods require the use ofcomputer modelling to predict the fíre exposure and the capacity ofstructures to resist fhose action. Also, large or small scale experimental tests are necessary to calibrate and verify the numerical models. The thermal model is essential for wood stmctures exposed to fire, because predicts the charring rate as a fünction offire exposure. The charring rate calculation ofmost stmctural wood elements allows simple calculations, but is more complicated for situations where the fire exposure is non-standard and in wood elements protected with other materiais.
Resumo:
This paper presents a numerical approach with finite element method in order to predict both the behaviour and the performance of the wooden slabs with rectangular perforations under fire exposure. These typical constructions have good sound absorption, thermal insulation and relevant architectonic features, they are used in many civil engineering applications. These slabs are normally installed at lower level in building constructions essentially due to an easy maintenance requisite. Depending on the installation requirement, the perforated wooden slabs could have an additional insulation material inside the cavities. The proposed numerical model could be applied to different design constructive slab solutions. For this purpose a 3D numerical simulation was conducted with particular attention to the wood thermal properties variation with temperature. The numerical results were compared with those obtained experimentally in laboratory, for two wooden slabs. The fire resistance (performance criteria related to the insulation (I) and integrity (E)) was evaluated, as well as the effect of rectangular perforations into the residual cross section of the slab. This study was conducted in accordance with European Standard EN 1365-2 and using a fire resistance furnace which complies the requirements of EN 1363-1 in the experimental test.
Resumo:
Bibliography: p. 59-64.
Resumo:
National Highway Traffic Safety Administration, Washington, D.C.
Resumo:
National Highway Traffic Safety Administration, Washington, D.C.
Resumo:
Bibliographical footnotes.
Resumo:
Mode of access: Internet.
Resumo:
At head of title: U.S. Department of Commerce. Daniel C. Roper, secretary. Bureau of Foreign and Domestic Commerce. Alexander V. Dye, director ...
Resumo:
"January, 1958."
Resumo:
MTSD 0364.