857 resultados para variable amplitude loading


Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present an experimental analysis of quadrature entanglement produced from a pair of amplitude squeezed beams. The correlation matrix of the state is characterized within a set of reasonable assumptions, and the strength of the entanglement is gauged using measures of the degree of inseparability and the degree of Einstein-Podolsky-Rosen (EPR) paradox. We introduce controlled decoherence in the form of optical loss to the entangled state, and demonstrate qualitative differences in the response of the degrees of inseparability and EPR paradox to this loss. The entanglement is represented on a photon number diagram that provides an intuitive and physically relevant description of the state. We calculate efficacy contours for several quantum information protocols on this diagram, and use them to predict the effectiveness of our entanglement in those protocols.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A comparison of a constant (continuous delivery of 4% FiO(2)) and a variable (initial 5% FiO(2) with adjustments to induce low amplitude EEG (LAEEG) and hypotension) hypoxic/ischemic insult was performed to determine which insult was more effective in producing a consistent degree of survivable neuropathological damage in a newborn piglet model of perinatal asphyxia. We also examined which physiological responses contributed to this outcome. Thirty-nine 1-day-old piglets were subjected to either a constant hypoxic/ischemic insult of 30- to 37-min duration or a variable hypoxic/ischemic insult of 30-min low peak amplitude EEG (LAEEG < 5 mu V) including 10 min of low mean arterial blood pressure (MABP < 70% of baseline). Control animals (n = 6) received 21% FiO(2) for the duration of the experiment. At 72 h, the piglets were euthanased, their brains removed and fixed in 4% paraformaldehyde and assessed for hypoxic/ischemic injury by histological analysis. Based on neuropathology scores, piglets were grouped as undamaged or damaged; piglets that did not survive to 72 h were grouped separately as dead. The variable insult resulted in a greater number of piglets with neuropathological damage (undamaged = 12.5%, damaged = 68.75%, dead = 18.75%) while the constant insult resulted in a large proportion of undamaged piglets (undamaged = 50%, damaged = 22.2%, dead = 27.8%). A hypoxic insult varied to maintain peak amplitude EEG < 5 mu V results in a greater number of survivors with a consistent degree of neuropathological damage than a constant hypoxic insult. Physiological variables MABP, LAEEG, pH and arterial base excess were found to be significantly associated with neuropathological outcome. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The results of two experiments are reported that examined how performance in a simple interceptive action (hitting a moving target) was influenced by the speed of the target, the size of the intercepting effector and the distance moved to make the interception. In Experiment 1, target speed and the width of the intercepting manipulandum (bat) were varied. The hypothesis that people make briefer movements, when the temporal accuracy and precision demands of the task are high, predicts that bat width and target speed will divisively interact in their effect on movement time (MT) and that shorter MTs will be associated with a smaller temporal variable error (VE). An alternative hypothesis that people initiate movement when the rate of expansion (ROE) of the target's image reaches a specific, fixed criterion value predicts that bat width will have no effect on MT. The results supported the first hypothesis: a statistically reliable interaction of the predicted form was obtained and the temporal VE was smaller for briefer movements. In Experiment 2, distance to move and target speed were varied. MT increased in direct proportion to distance and there was a divisive interaction between distance and speed; as in Experiment 1, temporal VE was smaller for briefer movements. The pattern of results could not be explained by the strategy of initiating movement at a fixed value of the ROE or at a fixed value of any other perceptual variable potentially available for initiating movement. It is argued that the results support pre-programming of MT with movement initiated when the target's time to arrival at the interception location reaches a criterion value that is matched to the pre-programmed MT. The data supported completely open-loop control when MT was less than between 200 and 240 ms with corrective sub-movements increasingly frequent for movements of longer duration.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

La presente Tesi ha per oggetto lo sviluppo e la validazione di nuovi criteri per la verifica a fatica multiassiale di componenti strutturali metallici . In particolare, i nuovi criteri formulati risultano applicabili a componenti metallici, soggetti ad un’ampia gamma di configurazioni di carico: carichi multiassiali variabili nel tempo, in modo ciclico e random, per alto e basso/medio numero di cicli di carico. Tali criteri costituiscono un utile strumento nell’ambito della valutazione della resistenza/vita a fatica di elementi strutturali metallici, essendo di semplice implementazione, e richiedendo tempi di calcolo piuttosto modesti. Nel primo Capitolo vengono presentate le problematiche relative alla fatica multiassiale, introducendo alcuni aspetti teorici utili a descrivere il meccanismo di danneggiamento a fatica (propagazione della fessura e frattura finale) di componenti strutturali metallici soggetti a carichi variabili nel tempo. Vengono poi presentati i diversi approcci disponibili in letteratura per la verifica a fatica multiassiale di tali componenti, con particolare attenzione all'approccio del piano critico. Infine, vengono definite le grandezze ingegneristiche correlate al piano critico, utilizzate nella progettazione a fatica in presenza di carichi multiassiali ciclici per alto e basso/medio numero di cicli di carico. Il secondo Capitolo è dedicato allo sviluppo di un nuovo criterio per la valutazione della resistenza a fatica di elementi strutturali metallici soggetti a carichi multiassiali ciclici e alto numero di cicli. Il criterio risulta basato sull'approccio del piano critico ed è formulato in termini di tensioni. Lo sviluppo del criterio viene affrontato intervenendo in modo significativo su una precedente formulazione proposta da Carpinteri e collaboratori nel 2011. In particolare, il primo intervento riguarda la determinazione della giacitura del piano critico: nuove espressioni dell'angolo che lega la giacitura del piano critico a quella del piano di frattura vengono implementate nell'algoritmo del criterio. Il secondo intervento è relativo alla definizione dell'ampiezza della tensione tangenziale e un nuovo metodo, noto come Prismatic Hull (PH) method (di Araújo e collaboratori), viene implementato nell'algoritmo. L'affidabilità del criterio viene poi verificata impiegando numerosi dati di prove sperimentali disponibili in letteratura. Nel terzo Capitolo viene proposto un criterio di nuova formulazione per la valutazione della vita a fatica di elementi strutturali metallici soggetti a carichi multiassiali ciclici e basso/medio numero di cicli. Il criterio risulta basato sull'approccio del piano critico, ed è formulato in termini di deformazioni. In particolare, la formulazione proposta trae spunto, come impostazione generale, dal criterio di fatica multiassiale in regime di alto numero di cicli discusso nel secondo Capitolo. Poiché in presenza di deformazioni plastiche significative (come quelle caratterizzanti la fatica per basso/medio numero di cicli di carico) è necessario conoscere il valore del coefficiente efficace di Poisson del materiale, vengono impiegate tre differenti strategie. In particolare, tale coefficiente viene calcolato sia per via analitica, che per via numerica, che impiegando un valore costante frequentemente adottato in letteratura. Successivamente, per validarne l'affidabilità vengono impiegati numerosi dati di prove sperimentali disponibili in letteratura; i risultati numerici sono ottenuti al variare del valore del coefficiente efficace di Poisson. Inoltre, al fine di considerare i significativi gradienti tensionali che si verificano in presenza di discontinuità geometriche, come gli intagli, il criterio viene anche esteso al caso dei componenti strutturali intagliati. Il criterio, riformulato implementando il concetto del volume di controllo proposto da Lazzarin e collaboratori, viene utilizzato per stimare la vita a fatica di provini con un severo intaglio a V, realizzati in lega di titanio grado 5. Il quarto Capitolo è rivolto allo sviluppo di un nuovo criterio per la valutazione del danno a fatica di elementi strutturali metallici soggetti a carichi multiassiali random e alto numero di cicli. Il criterio risulta basato sull'approccio del piano critico ed è formulato nel dominio della frequenza. Lo sviluppo del criterio viene affrontato intervenendo in modo significativo su una precedente formulazione proposta da Carpinteri e collaboratori nel 2014. In particolare, l’intervento riguarda la determinazione della giacitura del piano critico, e nuove espressioni dell'angolo che lega la giacitura del piano critico con quella del piano di frattura vengono implementate nell'algoritmo del criterio. Infine, l’affidabilità del criterio viene verificata impiegando numerosi dati di prove sperimentali disponibili in letteratura.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

With the extensive use of pulse modulation methods in telecommunications, much work has been done in the search for a better utilisation of the transmission channel.The present research is an extension of these investigations. A new modulation method, 'Variable Time-Scale Information Processing', (VTSIP), is proposed.The basic principles of this system have been established, and the main advantages and disadvantages investigated. With the proposed system, comparison circuits detect the instants at which the input signal voltage crosses predetermined amplitude levels.The time intervals between these occurrences are measured digitally and the results are temporarily stored, before being transmitted.After reception, an inverse process enables the original signal to be reconstituted.The advantage of this system is that the irregularities in the rate of information contained in the input signal are smoothed out before transmission, allowing the use of a smaller transmission bandwidth. A disadvantage of the system is the time delay necessarily introduced by the storage process.Another disadvantage is a type of distortion caused by the finite store capacity.A simulation of the system has been made using a standard speech signal, to make some assessment of this distortion. It is concluded that the new system should be an improvement on existing pulse transmission systems, allowing the use of a smaller transmission bandwidth, but introducing a time delay.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work has concentrated on the testing of induction machines to determine their temperature rise at full-load without mechanically coupling to a load machine. The achievements of this work are outlined as follows. 1. Four distinct categories of mixed-frequency test using an inverter have been identified by the author. The simulation results of these tests as well as the conventional 2-supply test have been analysed in detail. 2. Experimental work on mixed-frequency tests has been done on a small (4 kW) squirrel cage induction machine using a voltage source PWM inverter. Two out of the four categories of test suggested have been tested and the temperature rise results were found to be similar to the results of a direct loading test. Further, one of the categories of test proposed has been performed on a 3.3 kW slip-ring induction machine for the conformation of the rotor values. 3. A low current supply mixed-frequency test-rig has been proposed. For this purpose, a resonant bank was connected to the DC link of the inverter in order to maintain the exchange of power between the test machine and the resonant bank instead of between the main supply and the test machine. The resonant bank was then replaced with a special electro-mechanical energy storage unit. The current of the main power supply was then reduced in amplitude. 4. A variable inertia test for full load temperature rise testing of induction machines has been introduced. This test is purely mechanical in nature and does not require any electrical connection of the test machine to any other machine. It has the advantage of drawing very little net power from the supply.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Monoamines have an important role in neural plasticity, a key factor in cortical pain processing that promotes changes in neuronal network connectivity. Monoamine oxidase type A (MAOA) is an enzyme that, due to its modulating role in monoaminergic activity, could play a role in cortical pain processing. The X-linked MAOA gene is characterized by an allelic variant of length, the MAOA upstream Variable Number Tandem Repeat (MAOA-uVNTR) region polymorphism. Two allelic variants of this gene are known, the high-activity MAOA (HAM) and low-activity MAOA (LAM). We investigated the role of MAOA-uVNTR in cortical pain processing in a group of healthy individuals measured by the trigeminal electric pain-related evoked potential (tPREP) elicited by repeated painful stimulation. A group of healthy volunteers was genotyped to detect MAOA-uVNTR polymorphism. Electrical tPREPs were recorded by stimulating the right supraorbital nerve with a concentric electrode. The N2 and P2 component amplitude and latency as well as the N2-P2 inter-peak amplitude were measured. The recording was divided into three blocks, each containing 10 consecutive stimuli and the N2-P2 amplitude was compared between blocks. Of the 67 volunteers, 37 were HAM and 30 were LAM. HAM subjects differed from LAM subjects in terms of amplitude of the grand-averaged and first-block N2-P2 responses (HAM>LAM). The N2-P2 amplitude decreased between the first and third block in HAM subjects but not LAM subjects. The MAOA-uVNTR polymorphism seemed to influence the brain response in a repeated tPREP paradigm and suggested a role of the MAOA as a modulator of neural plasticity related to cortical pain processing. Monoamines have an important role in neural plasticity, a key factor in cortical pain processing that promotes changes in neuronal network connectivity. Monoamine oxidase type A (MAOA) is an enzyme that, due to its modulating role in monoaminergic activity, could play a role in cortical pain processing. © 2014 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A CMOS vector-sum phase shifter covering the full 360° range is presented in this paper. Broadband operational transconductance amplifiers with variable transconductance provide coarse scaling of the quadrature vector amplitudes. Fine scaling of the amplitudes is accomplished using a passive resistive network. Expressions are derived to predict the maximum bit resolution of the phase shifter from the scaling factor of the coarse and fine vector-scaling stages. The phase shifter was designed and fabricated using the standard 130-nm CMOS process and was tested on-wafer over the frequency range of 4.9–5.9 GHz. The phase shifter delivers root mean square (rms) phase and amplitude errors of 1.25° and 0.7 dB, respectively, at the midband frequency of 5.4 GHz. The input and output return losses are both below 17 dB over the band, and the insertion loss is better than 4 dB over the band. The circuit uses an area of 0.303 mm2 excluding bonding pads and draws 28 mW from a 1.2 V supply.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A variable width pulse generator featuring more than 4-V peak amplitude and less than 10-ns FWHM is described. In this design the width of the pulses is controlled by means of the control signal slope. Thus, a variable transition time control circuit (TTCC) is also developed, based on the charge and discharge of a capacitor by means of two tunable current sources. Additionally, it is possible to activate/deactivate the pulses when required, therefore allowing the creation of any desired pulse pattern. Furthermore, the implementation presented here can be electronically controlled. In conclusion, due to its versatility, compactness and low cost it can be used in a wide variety of applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The mesoporous SBA-15 silica with uniform hexagonal pore, narrow pore size distribution and tuneable pore diameter was organofunctionalized with glutaraldehyde-bridged silylating agent. The precursor and its derivative silicas were ibuprofen-loaded for controlled delivery in simulated biological fluids. The synthesized silicas were characterized by elemental analysis, infrared spectroscopy, (13)C and (29)Si solid state NMR spectroscopy, nitrogen adsorption, X-ray diffractometry, thermogravimetry and scanning electron microscopy. Surface functionalization with amine containing bridged hydrophobic structure resulted in significantly decreased surface area from 802.4 to 63.0 m(2) g(-1) and pore diameter 8.0-6.0 nm, which ultimately increased the drug-loading capacity from 18.0% up to 28.3% and a very slow release rate of ibuprofen over the period of 72.5h. The in vitro drug release demonstrated that SBA-15 presented the fastest release from 25% to 27% and SBA-15GA gave near 10% of drug release in all fluids during 72.5 h. The Korsmeyer-Peppas model better fits the release data with the Fickian diffusion mechanism and zero order kinetics for synthesized mesoporous silicas. Both pore sizes and hydrophobicity influenced the rate of the release process, indicating that the chemically modified silica can be suggested to design formulation of slow and constant release over a defined period, to avoid repeated administration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Negative-ion mode electrospray ionization, ESI(-), with Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) was coupled to a Partial Least Squares (PLS) regression and variable selection methods to estimate the total acid number (TAN) of Brazilian crude oil samples. Generally, ESI(-)-FT-ICR mass spectra present a power of resolution of ca. 500,000 and a mass accuracy less than 1 ppm, producing a data matrix containing over 5700 variables per sample. These variables correspond to heteroatom-containing species detected as deprotonated molecules, [M - H](-) ions, which are identified primarily as naphthenic acids, phenols and carbazole analog species. The TAN values for all samples ranged from 0.06 to 3.61 mg of KOH g(-1). To facilitate the spectral interpretation, three methods of variable selection were studied: variable importance in the projection (VIP), interval partial least squares (iPLS) and elimination of uninformative variables (UVE). The UVE method seems to be more appropriate for selecting important variables, reducing the dimension of the variables to 183 and producing a root mean square error of prediction of 0.32 mg of KOH g(-1). By reducing the size of the data, it was possible to relate the selected variables with their corresponding molecular formulas, thus identifying the main chemical species responsible for the TAN values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física