987 resultados para twice line frequency


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The issue of dynamic spectrum scene analysis in any cognitive radio network becomes extremely complex when low probability of intercept, spread spectrum systems are present in environment. The detection and estimation become more complex if frequency hopping spread spectrum is adaptive in nature. In this paper, we propose two phase approach for detection and estimation of frequency hoping signals. Polyphase filter bank has been proposed as the architecture of choice for detection phase to efficiently detect the presence of frequency hopping signal. Based on the modeling of frequency hopping signal it can be shown that parametric methods of line spectral analysis are well suited for estimation of frequency hopping signals if the issues of order estimation and time localization are resolved. An algorithm using line spectra parameter estimation and wavelet based transient detection has been proposed which resolves above issues in computationally efficient manner suitable for implementation in cognitive radio. The simulations show promising results proving that adaptive frequency hopping signals can be detected and demodulated in a non cooperative context, even at a very low signal to noise ratio in real time.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The development of algorithms, based on Haar functions, for extracting the desired frequency components from transient power-system relaying signals is presented. The applications of these algorithms to impedance detection in transmission line protection and to harmonic restraint in transformer differential protection are discussed. For transmission line protection, three modes of application of the Haar algorithms are described: a full-cycle window algorithm, an approximate full-cycle window algorithm, and a half-cycle window algorithm. For power transformer differential protection, the combined second and fifth harmonic magnitude of the differential current is compared with that of fundamental to arrive at a trip decision. The proposed line protection algorithms are evaluated, under different fault conditions, using realistic relaying signals obtained from transient analysis conducted on a model 400 kV, 3-phase system. The transformer differential protection algorithms are also evaluated using a variety of simulated inrush and internal fault signals.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a microscopic model for calculating the AC conductivity of a finite length line junction made up of two counter-or co-propagating single mode quantum Hall edges with possibly different filling fractions. The effect of density-density interactions and a local tunneling conductance (sigma) between the two edges is considered. Assuming that sigma is independent of the frequency omega, we derive expressions for the AC conductivity as a function of omega, the length of the line junction and other parameters of the system. We reproduce the results of Sen and Agarwal (2008 Phys. Rev. B 78 085430) in the DC limit (omega -> 0), and generalize those results for an interacting system. As a function of omega, the AC conductivity shows significant oscillations if sigma is small; the oscillations become less prominent as sigma increases. A renormalization group analysis shows that the system may be in a metallic or an insulating phase depending on the strength of the interactions. We discuss the experimental implications of this for the behavior of the AC conductivity at low temperatures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A general expression for the Mössbauer lineshape in the presence of a radio frequency field is derived. As an example the effect of the rf field on Fe57 nuclei is discussed for a situation where the 3/2 sublevel of 14.4 keV state of Fe57 is selectively populated. At resonance, both the diagonal and non-diagonal matrix elements contribute to the correlation function. As a result, in addition to a slight rf induced distortion of the main Mössbauer line. additional transition lines are obtained. Thus the present calculation supports the experimental observations of Heiman et al.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Quantifying nitrous oxide (N(2)O) fluxes, a potent greenhouse gas, from soils is necessary to improve our knowledge of terrestrial N(2)O losses. Developing universal sampling frequencies for calculating annual N(2)O fluxes is difficult, as fluxes are renowned for their high temporal variability. We demonstrate daily sampling was largely required to achieve annual N(2)O fluxes within 10% of the best estimate for 28 annual datasets collected from three continents, Australia, Europe and Asia. Decreasing the regularity of measurements either under- or overestimated annual N(2)O fluxes, with a maximum overestimation of 935%. Measurement frequency was lowered using a sampling strategy based on environmental factors known to affect temporal variability, but still required sampling more than once a week. Consequently, uncertainty in current global terrestrial N(2)O budgets associated with the upscaling of field-based datasets can be decreased significantly using adequate sampling frequencies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The driven state of a well-ordered flux line lattice in a single crystal of 2H-NbSe2 in the time domain has revealed the presence of substantial fluctuations in velocity, with large and distinct time periods (similar to seconds). A superposition of a periodic drive in the driven vortex lattice causes distinct changes in these fluctuations. We propose that prior to the onset of the peak effect there exists a heretofore unexplored regime of coherent dynamics, with unexpected behavior in velocity fluctuations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

With technology scaling, vulnerability to soft errors in random logic is increasing. There is a need for on-line error detection and protection for logic gates even at sea level. The error checker is the key element for an on-line detection mechanism. We compare three different checkers for error detection from the point of view of area, power and false error detection rates. We find that the double sampling checker (used in Razor), is the simplest and most area and power efficient, but suffers from very high false detection rates of 1.15 times the actual error rates. We also find that the alternate approaches of triple sampling and integrate and sample method (I&S) can be designed to have zero false detection rates, but at an increased area, power and implementation complexity. The triple sampling method has about 1.74 times the area and twice the power as compared to the Double Sampling method and also needs a complex clock generation scheme. The I&S method needs about 16% more power with 0.58 times the area as double sampling, but comes with more stringent implementation constraints as it requires detection of small voltage swings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: This multicentre, open-label, randomized, controlled phase II study evaluated cilengitide in combination with cetuximab and platinum-based chemotherapy, compared with cetuximab and chemotherapy alone, as first-line treatment of patients with advanced non-small-cell lung cancer (NSCLC). Patients and methods: Patients were randomized 1:1:1 to receive cetuximab plus platinum-based chemotherapy alone (control), or combined with cilengitide 2000 mg 1×/week i.v. (CIL-once) or 2×/week i.v. (CIL-twice). A protocol amendment limited enrolment to patients with epidermal growth factor receptor (EGFR) histoscore ≥200 and closed the CIL-twice arm for practical feasibility issues. Primary end point was progression-free survival (PFS; independent read); secondary end points included overall survival (OS), safety, and biomarker analyses. A comparison between the CIL-once and control arms is reported, both for the total cohorts, as well as for patients with EGFR histoscore ≥200. Results: There were 85 patients in the CIL-once group and 84 in the control group. The PFS (independent read) was 6.2 versus 5.0 months for CIL-once versus control [hazard ratio (HR) 0.72; P = 0.085]; for patients with EGFR histoscore ≥200, PFS was 6.8 versus 5.6 months, respectively (HR 0.57; P = 0.0446). Median OS was 13.6 for CIL-once versus 9.7 months for control (HR 0.81; P = 0.265). In patients with EGFR ≥200, OS was 13.2 versus 11.8 months, respectively (HR 0.95; P = 0.855). No major differences in adverse events between CIL-once and control were reported; nausea (59% versus 56%, respectively) and neutropenia (54% versus 46%, respectively) were the most frequent. There was no increased incidence of thromboembolic events or haemorrhage in cilengitide-treated patients. αvβ3 and αvβ5 expression was neither a predictive nor a prognostic indicator. Conclusions: The addition of cilengitide to cetuximab/chemotherapy indicated potential clinical activity, with a trend for PFS difference in the independent-read analysis. However, the observed inconsistencies across end points suggest additional investigations are required to substantiate a potential role of other integrin inhibitors in NSCLC treatment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

As is well known, when monochromatic light scattered by a liquid is examined under high resolution it exhibits a fine structure: an undisplaced central line and two lines on either side with wavelengths slightly different from that of the incident light. The appearance of the displaced components was first predicted by Brillouin1. On the basis of his theory, the observed displacements of frequency are regarded as a Doppler effect arising from the reflexion of the light wave by the progressive sound waves of thermal origin in the scattering medium. The frequency shift of the so-called Brillouin components is given by the formula where nu and c are the velocities of sound and light in the medium and theta is the angle of scattering. That the effect contemplated by Brillouin does arise in liquids and crystals is now a well-established experimental fact.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ultrafast Raman loss spectroscopy (URLS) enables one to obtain the vibrational structural information of molecular systems including fluorescent materials. URLS, a nonlinear process analog to stimulated Raman gain, involves a narrow bandwidth picosecond Raman pump pulse anda femtosecond broadband white light continuum. Under nonresonant condition, the Raman response appears as a negative (loss) signal, whereas, on resonance with the electronic transition the line shape changes from a negative to a positive through a dispersive form. The intensities observed and thus, the Franck-Condon activity (coordinate dependent), are sensitive to the wavelength of the white light corresponding to a particular Raman frequency with respect to the Raman pump pulse wavelength, i.e., there is a mode-dependent response in URLS. (C) 2010 American Institute of Physics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The issue of dynamic spectrum scene analysis in any cognitive radio network becomes extremely complex when low probability of intercept, spread spectrum systems are present in environment. The detection and estimation become more complex if frequency hopping spread spectrum is adaptive in nature. In this paper, we propose two phase approach for detection and estimation of frequency hoping signals. Polyphase filter bank has been proposed as the architecture of choice for detection phase to efficiently detect the presence of frequency hopping signal. Based on the modeling of frequency hopping signal it can be shown that parametric methods of line spectral analysis are well suited for estimation of frequency hopping signals if the issues of order estimation and time localization are resolved. An algorithm using line spectra parameter estimation and wavelet based transient detection has been proposed which resolves above issues in computationally efficient manner suitable for implementation in cognitive radio. The simulations show promising results proving that adaptive frequency hopping signals can be detected and demodulated in a non cooperative context, even at a very low signal to noise ratio in real time.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A three-level inverter produces six active vectors, each of normalized magnitudes 1, 0.866, and 0.5, besides a zero vector. The vectors of relative length 0.5 are termed pivot vectors.The three nearest voltage vectors are usually used to synthesize the reference vector. In most continuous pulsewidth-modulation(PWM) schemes, the switching sequence begins from a pivot vector and ends with the same pivot vector. Thus, the pivot vector is applied twice in a subcycle or half-carrier cycle. This paper proposes and investigates alternative switching sequences, which use the pivot vector only once but employ one of the other two vectors twice within the subcycle. The total harmonic distortion(THD) in the fundamental line current pertaining to these novel sequences is studied theoretically as well as experimentally over the whole range of modulation. Compared with centered space vector PWM, two of the proposed sequences lead to reduced THD at high modulation indices at a given average switching frequency.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Voltage source inverters (VSIs) supply nonsinusoidal voltages to induction motor drives, leading to line current distortion and torque pulsation. Conventional space vector pulsewidth modulation (PWM) techniques are widely used in VSIs on the account of good waveform quality and high dc bus utilization. In a conventional space vector PWM technique, the switching sequence begins with one zero state and ends with the other zero state in a subcycle. Some novel switching sequences have been proposed, which employ only one zero state but apply one of the two active states twice in a subcycle. One pair of such special switching sequences has recently been shown to reduce the pulsating torque considerably. In this paper, the conventional and special switching sequences are compared experimentally in terms of acoustic noise. In the low-and medium-speed ranges, the special switching sequence is seen to reduce the amplitude of the tonal component of noise at the switching frequency considerably and is also found to result in spread spectrum.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We have developed a technique to measure the absolute frequencies of optical transitions by using an evacuated Rb-stabilized ring-cavity resonator as a transfer cavity. The absolute frequency of the Rb D-2 line (at 780 nm) used to stabilize the cavity is known and allows us to determine the absolute value of the unknown frequency. We study wavelength-dependent errors due to dispersion at the cavity mirrors by measuring the frequency of the same transition in the Cs D-2 line (at 852 nm) at three cavity lengths. The spread in the values shows that dispersion errors are below 30 kHz, corresponding to a relative precision of 10(-10). We give an explanation for reduced dispersion errors in the ring-cavity geometry by calculating errors due to the lateral shift and the phase shift at the mirrors, and show that they are roughly equal but occur with opposite signs. We have earlier shown that diffraction errors (due to Guoy phase) are negligible in the ring-cavity geometry compared to a linear cavity; the reduced dispersion error is another advantage. Our values are consistent with measurements of the same transition using the more expensive frequency-comb technique. Our simpler method is ideally suited for measuring hyperfine structure, fine structure, and isotope shifts, up to several hundreds of gigahertz.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pulse width modulation (PWM) techniques involving different switching sequences are used in space vector-based PWM generation for reducing line current ripple in induction motor drives. This study proposes a hybrid PWM technique employing five switching sequences. The proposed technique is a combination of continuous PWM, discontinuous PWM (DPWM) and advanced bus clamping PWM methods. Performance of the proposed PWM technique is evaluated and compared with those of the existing techniques on a constant volts per hertz induction motor drive. In terms of total harmonic distortion in the line current, the proposed method is shown to be superior to both conventional space vector PWM (CSVPWM) and DPWM over a fundamental frequency range of 32-50 Hz at a given average switching frequency. The reduction in harmonic distortion is about 42% over CSVPWM at the rated speed of the drive.