442 resultados para trimming coils


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present an empirical investigation of the correcting coils behavior used to homogenize the field distribution of the race-track microtron accelerator end magnets. These end magnets belong to the second stage of the 30.0 MeV cw electron accelerator under construction at IFUSP, the race-track microtron booster, in which the beam energy is raised from 1.97 to 5.1 MeV. The correcting coils are attached to the pole faces and are based on the inhomogeneities of the magnetic field measured. The performance of these coils, when operating the end magnets with currents that differ by ±10% from the one used in the mappings that originated the coils copper leads, is presented. For one of the magnets, adjusting conveniently the current of the correcting coils makes it possible to homogenize field distributions of different intensities, once their shapes are practically identical to those that originated the coils. For the other one, the shapes are changed and the coils are less efficient. This is related to intrinsic factors that determine the inhomogeneities. However, we obtained uniformity of 0.001% in both cases. © 1998 The American Physical Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to compare the efficiency of washing and trimming broiler carcasses to reduce bacterial contamination. At the poste-visceration site, 100 broiler carcasses were collected during 4 visits to a slaughterhouse in Santa Catarina State, Brazil. Birds were from the same flock, age, and approximately 2.4 kg of weight. Groups were as follows: group 1, with fecal contamination; group 2, without fecal contamination; group 3, with fecal contamination and trimmed; group 4, with fecal contamination and washed; group 5, with fecal contamination, and washed and trimmed. Carcass washings were performed with at least 1.5 L/bird of potable water (0.5 to 1 mg/kg of residual chlorine) at room temperature (20-25 degrees C) using spray cabinets with 44 spray nozzles distributed into 2 chambers (pressure of 2 kgf/cm(2) and 4 kgf/cm(2)). Washed carcasses (trimmed or not) showed significantly (P < 0.05) lower counts of aerobic mesophiles (plate count agar) on the third evaluation, and even lower (P < 0.01) counts for total coliforms (CT) and fecal coliforms (Escherichia coli). Trimmed carcasses showed significantly lower counts (P < 0.05) for plate count agar; however, we observed higher counts for E. coli (P < 0.05). The association of both treatments (washing and trimming) showed significantly higher (P < 0.05) counts for coliforms (CT and E. coli). We can conclude that the washing method is overall more efficient than the trimming method to decontaminate chicken carcasses at the postevisceration site. Hopefully, our findings can help poultry companies to minimize production costs by applying the washing method for carcass decontamination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Every fall millions of blackbirds come down the Mississippi Flyway to return to their winter roosts in Arkansas, Louisiana, and East Texas. When these roosts are located in urban areas, public pressure makes the more common chemical means of control impractical. A less destructive and more permanent method of control was sought. At Rice University, in Houston, Texas, there has been a blackbird roost of various sizes and durations since 1956. For the past two years we have had the opportunity both to study roosting blackbird biology and experiment with habitat alteration as a control method. This particular report concentrates on the results and interpretation of the tree- trimming program initiated in August 1974. The birds involved are primarily Brown-headed Cowbirds (Molothrus ater), along with Starlings (sturnus vulgaris), Common and Great-tailed Grackles (Quiscalus quiscula and Cassidix mexicanus), Red-winged Blackbirds (Agelaius phoenicus) and Robins (Turdus migratorius). The campus comprises 121 ha and was planted with live oaks (Quercus virginiana) in 1912. These trees retain their foliage throughout the winter and now form a closed canopy over some 5-6 ha. In the 60s and early 70s most of the birds that came to Houston for the winter roosted in a 64-ha woodlot 10 km north of campus. In January 1970, the U.S. Fish and Wildlife Roosting Survey reported one million birds at this site we call the North Loop. Fifteen- thousand birds were estimated at Rice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study was designed in an attempt to identify the risk factors that could be significantly associated with angio graphic recurrences after selective endovascular treatment of aneurysms with inert platinum coils. A retrospective analysis of all patients with selective endovascular coil occlusion of intracranial aneurysms was prospectively collected from 1999 to 2003. There were 455 aneurysms treated with inert platinum coils and followed by digital subtraction angiography. Angio graphic results were classified according Roy and Raymond's classification. Recurrences were subjectively divided into minor and major. The most significant predictors for angio graphic recurrences were determined by ANOVAs logistic regression, Cochran-Mantel-Haenszel test, Fisher exact probability. Short-term (4.3 +/- 1.4 months) follow-up angiograms were available in 377 aneurysms, middle-term (14.1 +/- 4.0 months) in 327 and long-term (37.4 +/- 11.5 months) in 180. Recurrences were found in 26.8% of treated aneurysms with a mean of 21 +/- 15.7 months of follow-up. Major recurrences needing retreatment were present in 8.8% during a mean period follow-up of 17.9 +/- 12.29 months after the initial endovascular treatment. One patient (0.2%) experienced a bleed during the follow-up period. Recurrences after endovascular treatment of aneurysms with inert platinum coils are frequent, but hemorrhages are unusual. Single aneurysm, ruptured aneurysm, neck greater than 4 mm and time of follow-up were risk factors for recurrence after endovascular treatment. The retreatment of recurrent aneurysm decreases the risk of major recurrences 9.8 times. Long-term angiogram monitoring is necessary for the population with significant recurrence predictors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The quench characteristics of second generation (2 G) YBCO Coated Conductor (CC) tapes are of fundamental importance for the design and safe operation of superconducting cables and magnets based on this material. Their ability to transport high current densities at high temperature, up to 77 K, and at very high fields, over 20 T, together with the increasing knowledge in their manufacturing, which is reducing their cost, are pushing the use of this innovative material in numerous system applications, from high field magnets for research to motors and generators as well as for cables. The aim of this Ph. D. thesis is the experimental analysis and numerical simulations of quench in superconducting HTS tapes and coils. A measurements facility for the characterization of superconducting tapes and coils was designed, assembled and tested. The facility consist of a cryostat, a cryocooler, a vacuum system, resistive and superconducting current leads and signal feedthrough. Moreover, the data acquisition system and the software for critical current and quench measurements were developed. A 2D model was developed using the finite element code COMSOL Multiphysics R . The problem of modeling the high aspect ratio of the tape is tackled by multiplying the tape thickness by a constant factor, compensating the heat and electrical balance equations by introducing a material anisotropy. The model was then validated both with the results of a 1D quench model based on a non-linear electric circuit coupled to a thermal model of the tape, to literature measurements and to critical current and quench measurements made in the cryogenic facility. Finally the model was extended to the study of coils and windings with the definition of the tape and stack homogenized properties. The procedure allows the definition of a multi-scale hierarchical model, able to simulate the windings with different degrees of detail.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We evaluated the feasibility of a modified embolization technique of pulmonary arteriovenous malformations (PAVM) using venous sac embolization with detachable coils combined with the feeding artery embolization with the Amplatzer vascular plug (AVP).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE:Conventional platinum coils cause imaging artifacts that reduce imaging quality and therefore impair imaging interpretation on intraprocedural or noninvasive follow-up imaging. The purpose of this study was to evaluate imaging characteristics and artifact production of polymeric coils compared with standard platinum coils in vitro and in vivo.MATERIALS AND METHODS:Polymeric coils and standard platinum coils were evaluated in vitro with the use of 2 identical silicon aneurysm models coiled with a packing attenuation of 20% each. DSA, flat panel CT, CT, and MR imaging were performed. In vivo evaluation of imaging characteristics of polymeric coils was performed in experimentally created rabbit carotid bifurcation aneurysms. DSA, CT/CTA, and MR imaging were performed after endovascular treatment of the aneurysms. Images were evaluated regarding visibility of individual coils, coil mass, artifact production, and visibility of residual flow within the aneurysm.RESULTS:Overall, in vitro and in vivo imaging showed relevantly reduced artifact production of polymeric coils in all imaging modalities compared with standard platinum coils. Image quality of CT and MR imaging was improved with the use of polymeric coils, which permitted enhanced depiction of individual coil loops and residual aneurysm lumen as well as the peri-aneurysmal area. Remarkably, CT images demonstrated considerably improved image quality with only minor artifacts compared with standard coils. On DSA, polymeric coils showed transparency and allowed visualization of superimposed vessel structures.CONCLUSIONS:This initial experimental study showed improved imaging quality with the use of polymeric coils compared with standard platinum coils in all imaging modalities. This might be advantageous for improved intraprocedural imaging for the detection of complications and posttreatment noninvasive follow-up imaging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to analyze the immediate and long-term angiographic and clinical results of endovascular treatment of posterior circulation aneurysms with special regard to technical development.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

(31)P MRS magnetization transfer ((31)P-MT) experiments allow the estimation of exchange rates of biochemical reactions, such as the creatine kinase equilibrium and adenosine triphosphate (ATP) synthesis. Although various (31)P-MT methods have been successfully used on isolated organs or animals, their application on humans in clinical scanners poses specific challenges. This study compared two major (31)P-MT methods on a clinical MR system using heteronuclear surface coils. Although saturation transfer (ST) is the most commonly used (31)P-MT method, sequences such as inversion transfer (IT) with short pulses might be better suited for the specific hardware and software limitations of a clinical scanner. In addition, small NMR-undetectable metabolite pools can transfer MT to NMR-visible pools during long saturation pulses, which is prevented with short pulses. (31)P-MT sequences were adapted for limited pulse length, for heteronuclear transmit-receive surface coils with inhomogeneous B1 , for the need for volume selection and for the inherently low signal-to-noise ratio (SNR) on a clinical 3-T MR system. The ST and IT sequences were applied to skeletal muscle and liver in 10 healthy volunteers. Monte-Carlo simulations were used to evaluate the behavior of the IT measurements with increasing imperfections. In skeletal muscle of the thigh, ATP synthesis resulted in forward reaction constants (k) of 0.074 ± 0.022 s(-1) (ST) and 0.137 ± 0.042 s(-1) (IT), whereas the creatine kinase reaction yielded 0.459 ± 0.089 s(-1) (IT). In the liver, ATP synthesis resulted in k = 0.267 ± 0.106 s(-1) (ST), whereas the IT experiment yielded no consistent results. ST results were close to literature values; however, the IT results were either much larger than the corresponding ST values and/or were widely scattered. To summarize, ST and IT experiments can both be implemented on a clinical body scanner with heteronuclear transmit-receive surface coils; however, ST results are much more robust against experimental imperfections than the current implementation of IT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Infrared thermography (IRT) was used to assess the effect of routine claw trimming on claw temperature. In total, 648 IRT observations each were collected from 81 cows housed in 6 tiestalls before and 3 wk after claw trimming. The feet were classified as either healthy (nonlesion group, n = 182) or affected with infectious foot disorders (group IFD, n = 142). The maximal surface temperatures of the coronary band and skin and the difference of the maximal temperatures (ΔT) between the lateral and medial claws of the respective foot were assessed. Linear mixed models, correcting for the hierarchical structure of the data, ambient temperature, and infectious status of the claws, were developed to evaluate the effect of time in relation to the trimming event (d 0 versus d 21) and claw (medial versus lateral). Front feet and hind feet were analyzed separately. Ambient temperature and infectious foot status were identified as external and internal factors, respectively, that significantly affected claw temperature. Before claw trimming, the lateral claws of the hind feet were significantly warmer compared with the medial claws, whereas such a difference was not evident for the claws of the front feet. At d 21, ΔT of the hind feet was reduced by ≥ 0.25 °C, whereas it was increased by ≤ 0.13 °C in the front feet compared with d 0. Therefore, trimming was associated with a remarkable decrease of ΔT of the hind claws. Equalizing the weight bearing of the hind feet by routine claw trimming is associated with a measurable reduction of ΔT between the paired hind claws.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ACKNOWLEDGMENTS G.D.B. thanks the Wellcome Trust and MRC (United Kingdom) for funding.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Subunit oligomerization of many proteins is mediated by coiled-coil domains. Although the basic features contributing to the thermodynamic stability of coiled coils are well understood, the mechanistic details of their assembly have not yet been dissected. Here we report a 13-residue sequence pattern that occurs with limited sequence variations in many two-stranded coiled coils and that is absolutely required for the assembly of the Dictyostelium discoideum actin-bundling protein cortexillin I and the yeast transcriptional activator GCN4. The functional relationship between coiled-coil “trigger” sequences was manifested by replacing the intrinsic trigger motif of GCN4 with the related sequence from cortexillin I. We demonstrate that these trigger sequences represent autonomous helical folding units that, in contrast to arbitrarily chosen heptad repeats, can mediate coiled-coil formation. Aside from being of general interest for protein folding, trigger motifs should be of particular importance in the protein de novo design.