376 resultados para tributyltin hydride


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Few-cycle laser pulses are used to "pump and probe" image the vibrational wavepacket dynamics of a HD+ molecular ion. The quantum dephasing and revival structure of the wavepacket are mapped experimentally with time-resolved photodissociation imaging. The motion of the molecule is simulated using a quantum-mechanical model predicting the observed structure. The coherence of the wavepacket is controlled by varying the duration of the intense laser pulses. By means of a Fourier transform analysis both the periodicity and relative population of the vibrational states of the excited molecular ion have been characterized.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A wide range of palladium catalysed regio- and stereo-specific 5-, 6- and 7-exo-dig mono-, bis- and tris-cyclisation processes of aryl and vinyl halides and allylic acetates are described. The mono- and bis-cyclisation processes terminate in hydride capture from piperidine-formic acid or sodium formate. Addition of TI2CO3 results in alkyne-allene isomerisation and leads, after cyclisation, to 1,3-dienes which give Diels-Alder adducts in good yield. Copyright (C) 1996 Elsevier Science Ltd

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new, wide ranging, synthetically powerful, catalytic tandem cyclisation-anion capture process is proposed which depends on the rate of cyclisation of an organopalladium specifies (RPdX) onto a proximate alkene or diene being significantly faster than anion exchange and reductive elimination in the sequence RPdX --> RPdY --> RY + Pd(0). The catalytic cyclisation - anion capture sequence is illustrated for hydride capture by a wide variety of substrates giving rise to fused- and spiro-, carbo- and hetero-cyclic systems, regio- and stereo-specifically.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BaH (and its isotopomers) is an attractive molecular candidate for laser cooling to ultracold temperatures and a potential precursor for the production of ultracold gases of hydrogen and deuterium. The theoretical challenge is to simulate the laser cooling cycle as reliably as possible and this paper addresses the generation of a highly accurate ab initio $^{2}\Sigma^+$ potential for such studies. The performance of various basis sets within the multi-reference configuration-interaction (MRCI) approximation with the Davidson correction (MRCI+Q)is tested and taken to the Complete Basis Set (CBS) limit. It is shown that the calculated molecular constants using a 46 electron Effective Core-Potential (ECP) and even-tempered augmented polarized core-valence basis sets (aug-pCV$n$Z-PP, n= 4 and 5) but only including three active electrons in the MRCI calculation are in excellent agreement with the available experimental values. The predicted dissociation energy De for the X$^2\Sigma^+$ state (extrapolated to the CBS limit) is 16895.12 cm$^{-1}$ (2.094 eV), which agrees within 0.1$\%$ of a revised experimental value of <16910.6 cm$^{-1}$, while the calculated re is within 0.03 pm of the experimental result.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O tributilestanho (TBT) é considerado um dos xenobióticos mais tóxicos, produzidos e deliberadamente introduzidos no meio ambiente pelo Homem. Tem sido usado numa variedade de processos industriais e subsequentemente descarregado no meio ambiente. O tempo de meia-vida do TBT em águas marinhas é de várias semanas, mas em condições de anóxia nos sedimentos, pode ser de vários anos, devido à sua degradação mais lenta. Embora o TBT tenha sido descrito como sendo tóxico para eucariotas e procariotas, muitas bactérias podem ser resistentes a este composto. O presente trabalho teve como objetivo principal elucidar o mecanismo de resistência ao TBT em bactérias. Para além disso, pretendeu-se desenvolver um biorepórter para detectar TBT no ambiente. Para atingir estes objetivos foram delineadas várias tarefas cujos principais resultados obtidos se apresentam a seguir. Várias bactérias resistentes ao TBT foram isoladas de sedimento e água do Porto de Pesca Longínqua (PPL) na Ria de Aveiro, Portugal. Entre estas, Aeromonas molluscorum Av27 foi selecionada devido à sua elevada resistência a este composto (concentrações até 3 mM), à sua capacidade de degradar o TBT em compostos menos tóxicos (dibutilestanho, DBT e monobutilestanho, MBT) e também por usar o TBT como fonte de carbono. A. molluscorum Av27 foi caracterizada genotipica e fenotipicamente. Os fatores de virulência estudados mostraram que esta estirpe i) possui atividade lipolítica; ii) não é citotóxica para células de mamíferos, nomeadamente para células Vero; iii) não possui integrões de classe I e II e iv) possui cinco plasmídeos com aproximadamente 4 kb, 7 kb, 10 kb, 100 kb e mais de 100 kb. Estes resultados mostraram que a estirpe Av27 não é tóxica, aumentando assim o interesse nesta bactéria para futuras aplicações, nomeadamente na bioremediação. Os testes de toxicidade ao TBT mostraram que este composto tem um impacto negativo no crescimento desta estirpe, bem como, na densidade, no tamanho e na atividade metabólica das células e é responsável pela formação de agregados celulares. Assim, o TBT mostrou ser bastante tóxico para as bactérias interferindo com a atividade celular geral. O gene Av27-sugE, que codifica a proteína SugE pertencente à família das “small multidrug resistance proteins” (SMR), foi identificado como estando envolvido na resistência ao TBT nesta estirpe. Este gene mostrou ser sobreexpresso quando as células crescem na presença de TBT. O promotor do gene Av27-sugE foi utilizado para construir um bioreporter para detetar TBT, contendo o gene da luciferase do pirilampo como gene repórter. O biorepórter obtido reúne as características mais importantes de um bom biorepórter: sensibilidade (intervalo de limite de detecção de 1-1000 nM), rapidez (3 h são suficientes para a deteção de sinal) e, possivelmente, não é invasivo (pois foi construído numa bactéria ambiental). Usando sedimento recolhido no Porto de Pesca Longínqua da Ria de Aveiro, foi preparada uma experiência de microcosmos com o intuito de avaliar a capacidade de Av27 para bioremediar o TBT, isoladamente ou em associação com a comunidade bacteriana indígena. A análise das amostras de microcosmos por PCR-DGGE e de bibliotecas de 16S rDNA revelaram que a comunidade bacteriana é relativamente estável ao longo do tempo, mesmo quando Av27 é inoculada no sedimento. Para além disso, o sedimento estuarino demonstrou ser dominado por bactérias pertencentes ao filo Proteobacteria (sendo mais abundante as Delta e Gammaproteobacteria) e Bacteroidetes. Ainda, cerca de 13% dos clones bacterianos não revelaram nenhuma semelhança com qualquer dos filos já definidos e quase 100% afiliou com bactérias não cultiváveis do sedimento. No momento da conclusão desta tese, os resultados da análise química de compostos organoestânicos não estavam disponíveis, e por essa razão não foi possível tirar quaisquer conclusões sobre a capacidade desta bactéria remediar o TBT em sedimentos. Esses resultados irão ajudar a esclarecer o papel de A. molluscorum Av27 na remediação de TBT. Recentemente, a capacidade da estirpe Av27 remediar solo contaminado com TBT foi confirmada em bioensaios realizados com plantas, Brassica rapa e Triticum aestivum (Silva 2011a), e também com invertebrados Porcellionides pruinosus (Silva 2011B). Assim, poder-se-á esperar que a bioremediação do sedimento na experiência de microcosmos também tenha ocorrido. No entanto, só a análise química dos compostos organostânicos deverá ser conclusiva. Devido à dificuldade em realizar a análise analítica de organoestânicos, um método de bioensaio fácil, rápido e barato foi adaptado para avaliar a toxicidade do TBT em laboratório, antes de se proceder à análise química das amostras. O método provou a sua utilidade, embora tenha mostrado pouca sensibilidade quando se usam concentrações de TBT baixas. Em geral, os resultados obtidos contribuíram para um melhor entendimento do mecanismo de resistência ao TBT em bactérias e mostraram o potencial biotecnológico de A. molluscorum Av27, nomeadamente, no que refere à sua possível aplicação na descontaminação de TBT no ambiente e também no desenvolvimento de biorepórteres.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A flow injection hydride generation direct current plasma atomic emission spectrometric (FI-HG-DCP-AES) method was developed for the determination of lead at ng.ml-l level. Potassium ferricyanide (K3Fe(CN)6) was used along with sodium tetrahydroborate(III) (NaBH4) to produce plumbane (PbH4) in an acid medium. The design of a gas-liquid separator (hydride generator) was tested and the parameters of the flow injection system were optimized to achieve a good detection limit and sample throughput. The technique developed gave a detection limit of 0.7 ng.ml-l(3ob). The precision at 20 ng.ml"* level was 1.6 % RSD with 1 1 measurements (n=l 1). Volume of sample loop was 500 |J.l. A sample throughput of 120 h"^ was achieved. The transition elements, Fe(II), FeOH), Cd(n), Co(II), Mn(n), Ni(II) and Zn(n) do not interfere in this method but 1 mg,l'l Cu(II) will suppress 50 % of the signal from a sample containing 20 ng.ml'l Pb. This method was successfully applied to determine lead in a calcium carbonate (CaC03) matrix of banded coral skeletons from Si-Chang Island in Thailand.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Modifications to the commercial hydride generator, manufactured by Spectrametrics, resulted in improved operating procedure and enhancement of the arsenic and germanium signals. Experiments with arsenic(III) and arsenic(V) showed that identical reiults could be produced from both oxidation states. However, since arsenic(V) is reduced more slowly than arsenic(III), peak areas and not peak heights must be measured when the arsine is immediately stripped from the system (approximately 5 seconds reaction). When the reduction is allowed to proceed for 20 seconds before the arsine is stripped, peak heights may be used. For a 200 ng/mL solution, the relative standard deviation is 2.8% for As(III) and 3.8% for As(V). The detection limit for arsenic using the modified system is 0.50 ng/mL. Studies performed on As(V) standards show that the interferences from 1000 mg/L of nickel(II), cobalt(II), iron(III), copper(II), cadmium(II), and zinc(II) can be eliminated with the aid of 5 M Hel and 3% L-cystine. Conditions for the reduction of germanium to the corresponding hydride were investigated. The effect of different concentrations of HCl on the reduction of germanium to the covalent hydride in aqueous media by means of NaBH 4 solutions was assessed. Results show that the best response is accomplished at a pH of 1.7. The use of buffer solutions was similarly characterized. In both cases, results showed that the element is best reduced when the final pH of the solution after reaction is almost neutral. In addition, a more sensitive method, which includes the use of (NH4)2S208' has been developed. A 20% increase in the germanium signal is registered when compared to the signal achieved with Hel alone. Moreover, under these conditions, reduction of germanium could be accomplished, even when the solution's pH is neutral. For a 100 ng/mL germanium standard the rsd is 3%. The detection limit for germanium in 0.05 M Hel medium (pH 1.7) is 0.10 ng/mL and 0.09 ng/mL when ammonium persulphate is used in conjunction with Hel. Interferences from 1000 mg/L of iron(III), copper(II), cobalt(II), nickel(II), cadmium(II), lead(II), mercury(II), aluminum(III), tin(IV), arsenic(III), arsenic(V) and zinc(II) were studied and characterized. In this regard, the use of (NH4)ZS20S and Hel at a pH of 1.7 proved to be a successful mixture in the sbppression of the interferences caused by iron, copper, aluminum, tin, lead, and arsenic. The method was applied to the determination of germanium in cherts and iron ores. In addition, experiments with tin(IV) showed that a 15% increase in the tin signal can be accomplished in the presence of 1 mL of (NH4)2S20S 10% (m/V).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method using L-cysteine for the determination of arsenous acid (As(III)), arsenic acid (As(V)), monomethylarsonic acid (MMAA), and dimethylarsinic acid (DMAA) by hydride generation was demonstrated. The instrument used was a d.c. plasma atomic emission spectrometer (OCP-AES). Complete recovery was reported for As(III), As(V), and DMAA while 86% recovery was reported for MMAA. Detection limits were determined, as arsenic for the species listed previously, to be 1.2, 0.8, 1.1, and 1.0 ngemL-l, respectively. Precision values, at 50 ngemL-1 arsenic concentration, were f.80/0, 2.50/0, 2.6% and 2.6% relative standard deviation, respectively. The L-cysteine reagent was compared directly with the conventional hydride generation technique which uses a potassium iodide-hydrochloric acid medium. Recoveries using L-cysteine when compared with the conventional method provided the following results: similar recoveries were obtained for As(III), slightly better recoveries were obtained for As(V) and MMAA, and significantly better recoveries for DMAA. In addition, tall and sharp peak shapes were observed for all four species when using L-cysteine. The arsenic speciation method involved separation by ion exchange .. high perfonnance liquid chromatography (HPLC) with on-line hydride generation using the L.. cysteine reagent and measurement byOCP-AES. Total analysis time per sample was 12 min while the time between the start of subsequent runs was approximately 20 min. A binary . gradient elution program, which incorporated the following two eluents: 0.01 and 0.5 mM tri.. sodium citrate both containing 5% methanol (v/v) and both at a pH of approximately 9, was used during the separation by HPLC. Recoveries of the four species which were measured as peak area, and were normalized against As(III), were 880/0, 290/0, and 40% for DMAA, MMAA and As(V), respectively. Resolution factors between adjacent analyte peaks of As(III) and DMAA was 1.1; DMAA and MMAA was 1.3; and MMAA and As(V) was 8.6. During the arsenic speciation study, signals from the d.c. plasma optical system were measured using a new photon-signal integrating device. The_new photon integrator developed and built in this laboratory was based on a previously published design which was further modified to reflect current available hardware. This photon integrator was interfaced to a personal computer through an AID convertor. The .photon integrator has adjustable threshold settings and an adjustable post-gain device.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Arsenic, bismuth, germanium, antimony and tin were simultaneously determined by continuous hydride generation and inductively coupled plasma-atomic emission spectrometry . I Hydrides were introduced into four different types of gas-liquid separators. Two of the gas-liquid separators were available in-house. A third was developed for this project and a fourth was based on a design used by CET AC. The best signal intensity was achieved by the type II frit-based gas-liquid separator, but the modified Cetac design gave promise for the future, due to low relative standard deviation. A method was developed for the determination of arsenic, bismuth, antimony and tin in low-alloy steels. Four standard reference materials from NIST were dissolved in 10 mL aqua regia without heat. Good agreement was obtained between experimental values and certified values for arsenic, bismuth, antimony and tin. The method was developed to provide the analyst with the opportunity to determine the analytes by using simple aqueous standards to prepare calibration lines. Within the limits of the samples analyzed, the method developed is independent of matrix.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Analytical methods for the determination of trace amounts of germanium, tin and arsenic were established using hydride generation coupled with direct current plasma atomic emission spectrometry. A continuous gas flowing batch system for the hydride generation was investigated and was applied to the determination of germanium(Ge), tin(Sn), antimony(Sb) and lead(Pb) (Preliminary results suggest that it is also applicable to arsenic)As) ). With this system, the reproducibility of signals was improved and the determination was speeded up, compared with the conventional batch type hydride generation system. Each determination was complete within one minute. Interferences from a number of transition metal ions, especially from Pd(II), Pt(IV), Ni(II), Cu(II), Co(II), and Fe(II, III), have proven to be very serious under normal conditions, in the determination of germanium, tin, and arsenic. These interference effects were eliminated or significantly reduced in the presence of L-cystine or L-cysteine. Thus, a 10-1000 fold excess of Ni(II), Cu(II), Co(II), Fe(II), Pt(IV), Pd(II), etc. can be tolerated without interference, In the presence of L-cystine or L-cysteine, compared with absence of interference reducing agent. The methods for the determination of Ge, Sn, and As were examined by the analyses of standard reference materials. Interference effects from the sample matrix, for example, in transition metal-rich samples, copper, iron and steel, were eliminated by L-cystine (for As and Sn) and by LI cysteine (for Ge). The analysis of a number of standard reference materials gave excellent results of As and Sn contents in agreement with the certified values, showing there was no systematic interference. The detection limits for both germanium and tin were 20 pg ml- I . Preliminary studies were carried out for the determination of antimony and lead. Antimony was found to react with NaBH4, remaInIng from the previous determinations, giving an analytical signal. A reversed injection manner, i.e., injection of the NaBH4 solution prior to the analyte solution was used to avoid uncertainty caused by residual NaBH4 present and to ensure that an excess of NaB H4 was available. A solution of 0.4% L-cysteine was found to reduce the interference from selected transition metal ions, Co(II), Cu(II), Ni(II) and Pt(IV). Hydrochloric acid - hydrogen peroxide, nitric acid - ammonium persulphate, and potassium dichromate malic acid reaction systems for lead hydride generation were compared. The potassium dichromate - malic acid reaction medium proved to be the best with respect to reproducibility and minimal interference. Cu(II), Ni(II), and Fe(II) caused strong interference In lead determinations, which was not reduced by L-cysteine or Lcystine. Sodium citrate, ascorbic acid, dithizone, thiosemicarbazide and penicillamine reduced interferences to some extent. Further interference reduction studies were carried out uSIng a number of amino acids, glycine, alanine, valine, leucine and histidine, as possible interference reducing agents in the determination of germanium. From glycine, alanine, valine to leucine, the interference reduction effect in germanium determinations decreased. Histidine II was found to be very promising In the reduction of interference. In fact, histidine proved more efficient than L-cystine and L-cysteine In the reduction of interference from Ni(II) in the determination of germanium. Signal enhancement by easily ionized elements (EIEs), usually regarded as an interference effect in analysis by DCP-AES, was studied and successfully applied to advantage in improving the sensitivity and detection limit in the determination of As, Ge, Sn, Sb, and Pb. The effect of alkali and alkaline-earth elements on the determination of the above five hydride forming elements was studied. With the appropriate EIE, a signal enhancement of 40-115% was achieved. Linear calibration and good reproducibility were also obtained in the presence of EIEs. III

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis describes the synthesis, structural studies, and stoichiometric and catalytic reactivity of novel Mo(IV) imido silylamide (R'N)Mo(R2)(173_RIN-SiR32-H)(PMe3)n (1: Rl = tBu, Ar', Ar; R2 = Cl; R32 = Me2, MePh, MeCl, Ph2, HPh; n = 2; 2: R' = Ar, R2 = SiH2Ph, n = 1) and hydride complexes (ArN)Mo(H)(R)(PMe3)3 (R = Cl (3), SiH2Ph (4». Compounds of type 1 were generated from (R'N)Mo(PMe3)n(L) (5: R' = tBu, Ar', Ar; L = PMe3, r/- C2H4) and chlorohydrosilanes by the imido/silane coupling approach, recently discovered in our group. The mechanism of the reaction of 5 with HSiCh to give (ArN)MoClz(PMe3)3 (8) was studied by VT NMR, which revealed the intermediacy of (ArN)MCh(172 -ArN=SiHCl)(PMe3)z (9). The imido/silyl coupling methodology was transferred to the reactions of 5 with chlorine-free hydrosilanes. This approach allowed for the isolation of a novel ,B-agostic compound (ArN)Mo(SiHzPh)(173 -NAr-SiHPhH)(PMe3) (10). The latter was found to be active in a variety of hydrosilation processes, including the rare monoaddition of PhSiH3 to benzonitrile. Stoichiometric reactions of 11 with unsaturated compounds appear to proceed via the silanimine intermediate (ArN)M(17z-ArN=SiHPh)(PMe3) (12) and, in the case of olefins and nitriles, give products of Si-C coupling, such as (ArN)Mo(R)(173 -NAr-SiHPh-CH=CHR')(PMe3) (13: R = Et, R' = H; 14: R = H, R' = Ph) and (ArN)Mo(172-NAr-SiHPh-CHR=N)(PMe3) (15). Compound 13 was also subjected to catalysis showing much improved activity in the hydrosilation of carbonyls and alkenes. Hydride complexes 3 and 4 were prepared starting from (ArN)MoCh(PMe3)3 (8). Both hydride species catalyze a diversity of hydrosilation processes that proceed via initial substrate activation but not silane addition. The proposed mechanism is supported by stoichiometric reactions of 3 and 4, kinetic NMR studies, and DFf calculations for the hydrosilation of benzaldehyde and acetone mediated by 4.