997 resultados para tissue quantification
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Background: Very limited information is available from in vivo studies about whether smoking and/or nicotine affect gingival tissues in the absence of plaque. The purpose of this study is to evaluate the effect of the systemic administration of nicotine in the proliferation and counting of fibroblast-like cells in the gingival tissue of rats.Methods: Thirty adult male Wistar rats were randomly assigned into two groups to receive subcutaneous injections of a saline solution (control group = group C) or nicotine solution (group N; 3 mg/kg) twice a day. The animals were euthanized 37, 44, or 51 days after the first subcutaneous injection. Specimens were routinely processed for serial histologic sections. Five fields of view in the connective tissue adjacent to the gingival epithelium and above the alveolar bone crest of the maxillary first molar were selected for the counting of fibroblast-like cells. Data were statistically analyzed (P<0.05).Results: The intergroup analysis detected a lower number of fibroblast-like cells in group N compared to group C on days 37 (2.65 +/- 1.41 and 6.67 +/- 3.25, respectively), 44 (2.70 +/- 1.84 and 8.57 +/- 2.37, respectively), and 51(2.09 +/- 1.41 and 7.49 +/- 2.60, respectively) (P<0.05). The quantification of fibroblast-like cells showed no significant difference (P >0.05) in the intragroup analysis of control and nicotine throughout experimental periods. In the intergroup analysis, group N had reduced proliferating cell nuclear antigen positive fibroblasts compared to group C in all periods (P<0.05).Conclusion: The daily systemic administration of nicotine negatively affected, in vivo, the number and proliferation of fibroblast-like cells in the gingival tissue of rats. J Periodontol 2011;82:1206-1211.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
A análise morfométrica da melanina tecidual pode subsidiar quantitativamente a pesquisa em discromias. Os autores demonstram três técnicas de análise de imagem digital que permitem a identificação dos pixels equivalentes à melanina na epiderme pela coloração de Fontana-Masson, possibilitando o cálculo da sua porcentagem nas diferentes camadas da epiderme, e discutem os principais elementos relacionados à análise e a necessidade de rigorosa padronização do processo.
Resumo:
The aim of this study was to evaluate the amount of peroxide passage from the pulp chamber to the external enamel surface during the internal bleaching technique. Fifty bovine teeth were sectioned transversally 5 mm below the cemento-enamel junction (CEJ), and the remaining part of the root was sealed with a 2-mm layer of glass ionomer cement. The external surface of the samples was coated with nail varnish, with the exception of standardized circular areas (6-mm diameter) located on the enamel, exposed dentin, or cementum surface of the tooth. The teeth were divided into three experimental groups according to exposed areas close to the CEJ and into two control groups (n=10/group), as follows: GE, enamel exposure area; GC, cementum exposed area; GD, dentin exposed area; Negative control, no presence of internal bleaching agent and uncoated surface; and Positive control, pulp chamber filled with bleaching agent and external surface totally coated with nail varnish. The pulp chamber was filled with 35% hydrogen peroxide (Opalescence Endo, Ultradent). Each sample was placed inside of individual flasks with 1000 mu L of acetate buffer solution, 2 M (pH 4.5). After seven days, the buffer solution was transferred to a glass tube, in which 100 mu L of leuco-crystal violet and 50 mu L of horseradish peroxidase were added, producing a blue solution. The optical density of the blue solution was determined by spectrophotometer and converted into microgram equivalents of hydrogen peroxide. Data were submitted to Kruskal-Wallis and Dunn-Bonferroni tests (alpha=0.05). All experimental groups presented passage of peroxide to the external surface that was statistically different from that observed in the control groups. It was verified that the passage of peroxide was higher in GD than in GE (p<0.01). The GC group presented a significantly lower peroxide passage than did GD and GE (p<0.01). It can be concluded that the hydrogen peroxide placed into the pulp chamber passed through the dental hard tissues, reaching the external surface and the periodontal tissue. The cementum surface was less permeable than were the dentin and enamel surfaces.
Resumo:
“Um desidro-rotenóide produzido por cultura de calos e por raízes de plantas silvestres de Boerhaavia coccinea”. Cultura de calos foram estabelecidos de folhas e galhos finos de plântula de B. coccinea produzida in vitro e analisada para isofl avonóide. A quantificação do 6,9,11-triidroxi-6a,12a-desidro-rotenóide isolado das raízes de B. coccinea P Miller, coletada em seu habitat natural, e do mesmo rotenóide produzido na cultura de células estão descritos neste artigo. A análise rotineira em CLAE mostrou que a cultura de calos produziu o mesmo isoflavonóide encontrado nas raízes da planta do campo. A quantidade do metabólito secundário produzido in vitro foi de 955.35
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
To quantify fibrin degradation products after topical and subconjunctival administration of recombinant tissue plasminogen activator in rabbits. Methods: Fibrin formation was induced in the anterior chamber in 25 rabbits. Subsequently, five rabbits received an injection of r-TPA (positive control) in the anterior chamber, another 10 received a subconjunctival injection of r-TPA, and the remaining 10 received instillations of topical r-TPA. Afterwards, samples of aqueous humor were collected and semi-quantitative analysis of fibrin degradation products (FDP) was performed. Results: No statistical differences were noted between the treatment and control groups at any time point. Fibrin degradation products semi-quantification showed statistical improvement in the control group and the subconjunctival group. Conclusion: Fibrin degradation products were observed in the anterior chamber after subconjunctival administration of r-TPA. However, it was probably not sufficient to cause fibrin degradation. Topical r-TPA did not effectively absorb anterior chamber fibrin.
Resumo:
Degeneration of tendon tissue is a common cause of tendon dysfunction with the symptoms of repeated episodes of pain and palpable increase of tendon thickness. Tendon mechanical properties are directly related to its physiological composition and the structural organization of the interior collagen fibers which could be altered by tendon degeneration due to overuse or injury. Thus, measuring mechanical properties of tendon tissue may represent a quantitative measurement of pain, reduced function, and tissue health. Ultrasound elasticity imaging has been developed in the last two decades and has proved to be a promising tool for tissue elasticity imaging. To date, however, well established protocols of tendinopathy elasticity imaging for diagnosing tendon degeneration in early stages or late stages do not exist. This thesis describes the re-creation of one dynamic ultrasound elasticity imaging method and the development of an ultrasound transient shear wave elasticity imaging platform for tendon and other musculoskeletal tissue imaging. An experimental mechanical stage with proper supporting systems and accurate translating stages was designed and made. A variety of high-quality tissue-mimicking phantoms were made to simulate homogeneous and heterogeneous soft tissues as well as tendon tissues. A series of data acquisition and data processing programs were developed to collect the displacement data from the phantom and calculate the shear modulus and Young’s modulus of the target. The imaging platform was found to be capable of conducting comparative measurements of the elastic parameters of the phantoms and quantitatively mapping elasticity onto ultrasound B-Mode images. This suggests the system has great potential for not only benefiting individuals with tendinopathy with an earlier detection, intervention and better rehabilitation, but also for providing a medical tool for quantification of musculoskeletal tissue dysfunction in other regions of the body such as the shoulder, elbow and knee.
Resumo:
Objectives: This study evaluated subcutaneous tissue response to Aroeira (Myracrodruon urundeuva) extract employing edemogenic and histological analyses. Material and methods: Test groups consisted of aqueous and ethanolic Aroeira extracts and saline (control). For groups consisted of aqueous and ethanolic Aroeira extracts and saline Blue. After 30 min, the extracts and saline were injected on the dorsum of the rats, which were then sacrificed after 3 and 6 h. Readings were performed in a spectrophotometer. For subcutaneous implantation, 30 rats received a polyethylene tube containing the extracts on their dorsum and then they were killed after 7 and 28 days. The samples were processed for histological analysis and evaluated with a light microscope. The inflammatory infiltrate was quantified. Results: There were no statistically significant differences between aqueous extract and saline groups in relation to edema quantification in the different periods (p > 0.05). Ethanolic solution resulted in more edema independently of the experimental period (p < 0.05). Histological analysis showed similar results on the 7-day period for the 3 groups. There was a notable reduction on inflammatory cell number for saline and aqueous extract groups at 28 days. Conclusion: The aqueous extract showed biocompatible properties similar to those of saline.
Resumo:
Studies on the collagen system of the human myocardium are still limited compared to those on small laboratory animals. The aim of this work was to observe the collagen tissue of the myocardium of the human heart as a function of age. The types of collagen, as well as the density of collagen tissue and the diameter of collagen fibrils, were examined. Fragments of the left ventricular wall from 15 hearts, 5 from children, 5 from young adults, and 5 from elderly individuals, were analyzed by using the Picrosirius-polarization method and by transmission electron microscopy (TEM). The results showed the presence of collagen type III and collagen type I, both in the endomysium and perimysium of the 3 groups studied. Measurements of collagen content in myocardial tissue displayed that both endomysial and perimysial collagen increase in number and thickness in the adult and elderly. These histochemical results coincided with the observations obtained with the electron microscope in showing an increase in the number of collagen fibrils with a large diameter in the adult and elderly hearts. The present results on cardiac collagen may be important for assessing the pathogenesis of several cardiopathies in the hearts of children, young adults, and the elderly.
Resumo:
3D video-fluoroscopy is an accurate but cumbersome technique to estimate natural or prosthetic human joint kinematics. This dissertation proposes innovative methodologies to improve the 3D fluoroscopic analysis reliability and usability. Being based on direct radiographic imaging of the joint, and avoiding soft tissue artefact that limits the accuracy of skin marker based techniques, the fluoroscopic analysis has a potential accuracy of the order of mm/deg or better. It can provide fundamental informations for clinical and methodological applications, but, notwithstanding the number of methodological protocols proposed in the literature, time consuming user interaction is exploited to obtain consistent results. The user-dependency prevented a reliable quantification of the actual accuracy and precision of the methods, and, consequently, slowed down the translation to the clinical practice. The objective of the present work was to speed up this process introducing methodological improvements in the analysis. In the thesis, the fluoroscopic analysis was characterized in depth, in order to evaluate its pros and cons, and to provide reliable solutions to overcome its limitations. To this aim, an analytical approach was followed. The major sources of error were isolated with in-silico preliminary studies as: (a) geometric distortion and calibration errors, (b) 2D images and 3D models resolutions, (c) incorrect contour extraction, (d) bone model symmetries, (e) optimization algorithm limitations, (f) user errors. The effect of each criticality was quantified, and verified with an in-vivo preliminary study on the elbow joint. The dominant source of error was identified in the limited extent of the convergence domain for the local optimization algorithms, which forced the user to manually specify the starting pose for the estimating process. To solve this problem, two different approaches were followed: to increase the optimal pose convergence basin, the local approach used sequential alignments of the 6 degrees of freedom in order of sensitivity, or a geometrical feature-based estimation of the initial conditions for the optimization; the global approach used an unsupervised memetic algorithm to optimally explore the search domain. The performances of the technique were evaluated with a series of in-silico studies and validated in-vitro with a phantom based comparison with a radiostereometric gold-standard. The accuracy of the method is joint-dependent, and for the intact knee joint, the new unsupervised algorithm guaranteed a maximum error lower than 0.5 mm for in-plane translations, 10 mm for out-of-plane translation, and of 3 deg for rotations in a mono-planar setup; and lower than 0.5 mm for translations and 1 deg for rotations in a bi-planar setups. The bi-planar setup is best suited when accurate results are needed, such as for methodological research studies. The mono-planar analysis may be enough for clinical application when the analysis time and cost may be an issue. A further reduction of the user interaction was obtained for prosthetic joints kinematics. A mixed region-growing and level-set segmentation method was proposed and halved the analysis time, delegating the computational burden to the machine. In-silico and in-vivo studies demonstrated that the reliability of the new semiautomatic method was comparable to a user defined manual gold-standard. The improved fluoroscopic analysis was finally applied to a first in-vivo methodological study on the foot kinematics. Preliminary evaluations showed that the presented methodology represents a feasible gold-standard for the validation of skin marker based foot kinematics protocols.
Resumo:
Real-time PCR (qPCR) is the method of choice for quantification of mitochondrial DNA (mtDNA) by relative comparison of a nuclear to a mitochondrial locus. Quantitative abnormal mtDNA content is indicative of mitochondrial disorders and mostly confines in a tissue-specific manner. Thus handling of degradation-prone bioptic material is inevitable. We established a serial qPCR assay based on increasing amplicon size to measure degradation status of any DNA sample. Using this approach we can exclude erroneous mtDNA quantification due to degraded samples (e.g. long post-exicision time, autolytic processus, freeze-thaw cycles) and ensure abnormal DNA content measurements (e.g. depletion) in non-degraded patient material. By preparation of degraded DNA under controlled conditions using sonification and DNaseI digestion we show that erroneous quantification is due to the different preservation qualities of the nuclear and the mitochondrial genome. This disparate degradation of the two genomes results in over- or underestimation of mtDNA copy number in degraded samples. Moreover, as analysis of defined archival tissue would allow to precise the molecular pathomechanism of mitochondrial disorders presenting with abnormal mtDNA content, we compared fresh frozen (FF) with formalin-fixed paraffin-embedded (FFPE) skeletal muscle tissue of the same sample. By extrapolation of measured decay constants for nuclear DNA (λnDNA) and mtDNA (λmtDNA) we present an approach to possibly correct measurements in degraded samples in the future. To our knowledge this is the first time different degradation impact of the two genomes is demonstrated and which evaluates systematically the impact of DNA degradation on quantification of mtDNA copy number.
Resumo:
BACKGROUND: Cyclic recruitment during mechanical ventilation contributes to ventilator associated lung injury. Two different pathomechanisms in acute respiratory distress syndrome (ARDS) are currently discussed: alveolar collapse vs persistent flooding of small airways and alveoli. We compare two different ARDS animal models by computed tomography (CT) to describe different recruitment and derecruitment mechanisms at different airway pressures: (i) lavage-ARDS, favouring alveolar collapse by surfactant depletion; and (ii) oleic acid ARDS, favouring alveolar flooding by capillary leakage. METHODS: In 12 pigs [25 (1) kg], ARDS was randomly induced, either by saline lung lavage or oleic acid (OA) injection, and 3 animals served as controls. A respiratory breathhold manoeuvre without spontaneous breathing at different continuous positive airway pressure (CPAP) was applied in random order (CPAP levels of 5, 10, 15, 30, 35 and 50 cm H(2)O) and spiral-CT scans of the total lung were acquired at each CPAP level (slice thickness=1 mm). In each spiral-CT the volume of total lung parenchyma, tissue, gas, non-aerated, well-aerated, poorly aerated, and over-aerated lung was calculated. RESULTS: In both ARDS models non-aerated lung volume decreased significantly from CPAP 5 to CPAP 50 [oleic acid lung injury (OAI): 346.9 (80.1) to 96.4 (48.8) ml, P<0.001; lavage-ARDS: 245 17.6) to 42.7 (4.8) ml, P<0.001]. In lavage-ARDS poorly aerated lung volume decreased at higher CPAP levels [232 (45.2) at CPAP 10 to 84 (19.4) ml at CPAP 50, P<0.001] whereas in OAI poorly aerated lung volume did not vary at different airway pressures. CONCLUSIONS: In both ARDS models well-aerated and non-aerated lung volume respond to different CPAP levels in a comparable fashion: Thus, a cyclical alveolar collapse seems to be part of the derecruitment process also in the OA-ARDS. In OA-ARDS, the increase in poorly aerated lung volume reflects the specific initial lesion, that is capillary leakage with interstitial and alveolar oedema.
Resumo:
Francisella tularensis, a small Gram-negative facultative intracellular bacterium, is the causative agent of tularaemia, a severe zoonotic disease transmitted to humans mostly by vectors such as ticks, flies and mosquitoes. The disease is endemic in many parts of the northern hemisphere. Among animals, the most affected species belong to rodents and lagomorphs, in particular hares. However, in the recent years, many cases of tularaemia among small monkeys in zoos were reported. We have developed a real-time PCR that allows to quantify F. tularensis in tissue samples. Using this method, we identified the spleen and the kidney as the most heavily infected organ containing up to 400 F. tularensis bacteria per simian host cell in two common squirrel monkeys (Saimiri sciureus) from a zoo that died of tularaemia. In other organs such as the brain, F. tularensis was detected at much lower titres. The strain that caused the infection was identified as F. tularensis subsp. holarctica biovar I, which is susceptible to erythromycin. The high number of F. tularensis present in soft organs such as spleen, liver and kidney represents a high risk for persons handling such carcasses and explains the transmission of the disease to a pathologist during post-mortem analysis. Herein, we show that real-time PCR allows a reliable and rapid diagnosis of F. tularensis directly from tissue samples of infected animals, which is crucial in order to attempt accurate prophylactic measures, especially in cases where humans or other animals have been exposed to this highly contagious pathogen.