350 resultados para teracationic porphyrin


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Methyl-, ethyl-, propyl- and n-butyl cobalt porphyrins were electrochemically synthesized and studied byIn-situ cyclic voltammetry and UV-Visible spectro-el ectrochemistry. Rate constants for the alkylations were determined. It was found that the four alkyl saturated tetraphenylchlorin cobalt complexes were formed after electrochemical reduction of the alkyl cobalt porphyrins.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A rapid rotation-scan method was used for the electrocatalytic oxidation of H2O2 at a cobalt protoporphyrin modified pyrolytic graphite electrode (CoPP/PG). The rate constant of H2O2 oxidation at the CoPP/PG electrode at different potentials and in different pH solutions was measured. The variation of catalytic activity with reaction charges (Q) passed through the electrode was analyzed. This provided a convenient electrochemical method to study the passivation and poisoning of catalytic sites with time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, five types of chemically modified electrode (CMEs) prepared with the deposition of platinum particles on various surfaces of glassy carbon (GC) modified with cobalt porphyrin and Nafion(R) solution are characterized using the electron scanning microscope (SEM). Their activities in the four-electron reduction of dioxygen to water on the basis of their electrochemical data from cyclic voltammetric and rotating ring-disk electrode (RRDE) experiments are examined and compared. Platinum particles dispersed on the GC surface adsorbed with the cobalt porphyrin exhibit the highest activity for the electrocatalytic reduction of dioxygen. However it is interesting that the cobalt ion is lost from the center of the porphyrin ring during the preparation of the cobalt porphyrin + Nafion mixture solution, while the porphyrin ring still remains in the Nafion film, as shown by EDX analysis. The incorporation of the porphyrin may change the structure of the Nafion film into a looser form, since the platinum particles dispersed in the film are more readily exposed, resulting in more favourable mass transfer and higher activity for the electrocatalytic reduction of dioxygen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A microcarbon array electrode was modified by the placement of a Nafion film containing cobalt tetramethylpyridyl phorphyrin on its surface. This electrode was applied to the analysis of solution glucose when it was further modified by the immobilization of glucose oxidase on the outermost surface of the Nafion by the cross-linking of serum albumin with glutaraldehyde. The concomitant decrease in the concentration of oxygen, as it was consumed in the enzymatic reaction of glucose with glucose oxidase, was determined by either cyclic voltammetry or a double potential step method at the porphyrin-Nafion catalytic electrode. Glucose could be determined in the range of 0.01-4 mM rapidly, without interference from substances such as ascorbate or other saccharides.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Novel surface-modified hydrogel materials have been prepared by binding charged porphyrins TMPyP (tetrakis-(4-N-methylpyridyl)porphyrin) and TPPS (tetrakis(4-sulfonatophenyl)porphyrin) to copolymers of HEMA (2-hydroxyethyl methacrylate) with either MAA (methacrylic acid) or DEAEMA (2-(diethylamino)ethylmethacrylate). The charged hydrogels display strong electrostatic interactions with the appropriate cationic or anionic porphyrins to give materials which are intended to be used to generate cytotoxic singlet oxygen (1O2) on photoexcitation and can therefore be used to reduce postoperative infection of the intraocular hydrogel-based replacement lenses that are used in cataract surgery. The UV/vis spectra of TMPyP in MAA:HEMA copolymers showed a small shift in the Soret band and a change from single exponential (161 ���­s) triplet decay lifetime in solution to a decay that could be fitted to a biexponential fit with two approximately equal components with ���´ ) 350 and 1300 ���­s. O2 bubbling reduced the decay to a dominant (90%) component with a much reduced lifetime of 3 ���­s and a minor, longer lived (20 ���­s) component. With D2O solvent the 1O2 lifetime was measured by 1270 nm fluorescence as 35 ���­s in MAA:HEMA, compared to 67 ���­s in solution, although absorbance-matched samples showed similar yield of 1O2 in the polymers and in aqueous solution. In contrast to the minor perturbation in photophysical properties caused by binding TMPyP to MAA:HEMA, TPPS binding to DEAEMA:HEMA copolymers profoundly changed the 1O2 generating ability of the TPPS. In N2-bubbled samples, the polymer-bound TPPS behaved in a similar manner to TMPyP in its copolymer host; however, O2 bubbling had only a very small effect on the triplet lifetime and no 1O2 generation could be detected. The difference in behavior may be linked to differences in binding in the two systems. With TMPyP in MAA:HEMA, confocal fluorescence microscopy showed significant penetration of the porphyrin into the core of the polymer film samples (>150 ���­m). However, for TPPS in DEAEMA:HEMA copolymers, although the porphyrin bound much more readily to the polymer, it remained localized in the first 20 ���­m, even in heavily loaded samples. It is possible that the resulting high concentration of TPPS may have cross-linked the hydrogels to such an extent that it significantly reduced the solubility and/or diffusion rate of oxygen into the doped polymers. This effect is significant since it demonstrates that even simple electrostatic binding of charged porphyrins to hydrogels can have an unexpectedly large effect on the properties of the system as a whole. In this case it makes the apparently promising TPPS/DEAEMA:HEMA system a poor candidate for clinical application as a postoperative antibacterial treatment for intraocular lenses while the apparently equivalent cationic system TMPyP/MAA:HEMA displays all the required properties.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The free-base form of tetra-tert-butyl porphine (TtBP), which has extremely bulky meso substituents, is severely distorted from planarity, with a ruffling angle of 65.5degrees. The resonance Raman spectrum of TtBP (lambda(ex) = 457.9 nm) and its d(2), d(8), and d(10) isotopomers have been recorded, and while the spectra show high-frequency bands similar to those observed for planar meso-substituted porphyrins, there are several additional intense bands in the low-frequency region. Density functional calculations at the B3-LYP/6-31G(d) level were carried out for all four isotopomers, and calculated frequencies were scaled using a single factor of 0.98. The single factor scaling approach was validated on free base porphine where the RMS error was found to be 14.9 cm(-1). All the assigned bands in the high-frequency (> 1000 cm(-1)) region of TtBP were found to be due to vibrations similar in character to the in-plane skeletal modes of conventional planar porphyrins. In the low-frequency region, two of the bands, assigned as nu(8) (ca. 330 cm(-1)) and nu(16) (ca. 540 cm(-1)), are also found in planar porphyrins such as tetra-phenyl porphine (TPP) and tetra-iso-propyl porphine (IPP). Of the remaining three very strong bands, the lowest frequency band was assigned as gamma(12) (pyr swivel, obsd 415 cm(-1), calcd 407 cm(-1) in do). The next band, observed at 589 cm-1 in the do compound (calcd 583 cm(-1)), was assigned as a mode whose composition is a mixture of modes that were previously labeled gamma(13) (gamma(CmCaHmCa)) andy gamma(11) (pyr fold(asym)) in NiOEP. The final strong band, observed at 744 cm(-1) (calcd 746 cm(-1)), was assigned to a mode whose composition is again a mixture of gamma(11) and gamma(13), although here it is gamma(11) rather than gamma(13) which predominates. These bands have characters and positions similar to those of three of the four porphyrin ring-based, weak bands that have previously been observed for NiTPP. In addition there are several weaker bands in the TtBP spectra that are also

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The pH dependencies of the UV-vis and fluorescent spectra of new water-soluble dendritic porphyrins and tetrabenzoporphyrins were studied. Because of extended pi-conjugation and nonplanar distortion, the absorption and the emission bands of tetraaryltetrabenzoporphyrins (Ar4TBP) are red-shifted and do not overlap with those of regular tetraarylporphyrins (Ar4P). When encapsulated inside dendrimers with hydrophilic outer layers, Ar(4)Ps and Ar(4)TBPs become water soluble and can serve as pH indicators, with pKs adjustable by the peripheral charges on the dendrimers. Two new dendritic porphyrins, Gen 4 polyglutamic porphyrin dendrimer H2P-Glu(4)OH (1) with 64 peripheral carboxylates and Gen 1 poly(ester amide) Newkome-type tetrabenzoporphyrin dendrimer H2TBP-Nw(1)OH (2) with 36 peripheral carboxylates, were synthesized and characterized. The pKs of the encapsulated porphyrins (pK(H2P-Glu)(OH)(4) = 6.2 and pK(H2TBP)-Nw(1)OH = 6.3) were found to be strongly influenced by the dendrimers, revealing significant electrostatic shielding of the cores by the peripheral charges. The titration curves obtained by differential excitation using the mixtures of the dendrimers were shown to be identical to those determined for the dendrimers individually. Due to their peripheral carboxylates and nanometric molecular size, porphyrin dendrimers cannot penetrate through phospholipid membranes. Dendrimer 1 was captured inside phospholipid liposomes, which were suspended in a solution containing dendrimer 2. No response from 1 was detected upon pH changes in the bulk solution, while the response from 2 was predictably strong. When proton channels were created in the liposome walls, both compounds responded equally to the bulk pH changes. These results suggest that porphyrin dendrimers can be used as fluorescent pH indicators for proton gradient measurements.