833 resultados para system efficiency
Ecological impacts from syngas burning in internal combustion engine: Technical and economic aspects
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
In soybean culture water deficit is one of the most limiting factors to the maximum yield obtained. Genotypes identification with drought tolerance capacity is fundamental to solve this problem. The objective in this paper was analyze the physiological quality and physiological and biochemical responses of soybeans cultivars (MG/BR 46 Conquista, UFUS Carajás, UFUS Impacta, UFUS Riqueza and UFUS Xavante) submitted to water stress with PEG 6000 solutions in different levels of osmotic potentials (0; -0,1; -0,2; -0,3 and -0,4 MPa). Physiological quality of cultivars were evaluated by seedling length test and fresh and dry biomass. The biochemical responses were evaluated by detection of indol-acetic acid (IAA), by saccharose content and seedling water transportation. UFUS Riqueza presented the best performance in physiological quality tests, saccharose content, absorption and water absorption velocity in seedling. UFUS Xavante showed the highest IAA's concentration and the greater weight of seedling in water transportation test.
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
In a recent paper, "A combined tool for environmental scientists and decision makers: ternary diagrams and emergy accounting." [Giannettti BF, Barrella FA, Almeida CMVB. A combined tool for environment scientists and decision makers: ternary diagrams and emergy accounting. J Clean Prod, in press http://dx.doi.org/10.1016/j.jclepro.2004.09.002] Ternary diagrams were proposed as a graphical tool to assist emergy analysis. The graphical representation of the emergy accounting data makes it possible to compare processes and systems with and without ecosystem services, to evaluate improvements and to follow the system performance over time. The graphic tool is versatile and adaptable to represent products, processes, systems, countries, and different periods of time.The use and the versatility of ternary diagrams for assisting in performing emergy analyses are illustrated by means of five examples taken from the literature, which are presented and discussed. It is shown that emergetic ternary diagram's properties assist the assessment of the system of the system efficiency, its dependance upon renewable and non-renewable inputs and the environmental support for dilution and abatement of process emissions. With the aid of ternary diagrams, details such as the interaction between systems and between systems and the environment are recognized and evaluated. Such a tool for graphical analysis allows a transparent presentation of the results and can serve as an interface between emergy scientists and decision makers, provided the meaning of each line in the diagram is carefully explained and understood. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
The aim of this work is to make a qualitatively and ecologically evaluation of a compact cogeneration system that operates with synthesis gas obtained from a gasifier. Using the Eucalyptus Biomass as fuel, that passes through a wood gasifier (Drowndraft type) and supply the internal combustion engine. The compact cogeneration system is composed of two heat exchangers, an energy generator connected to an internal combustion engine and an absorption refrigeration system. The complete system is installed in the laboratory from the Energy Department at the University of Guaratinguetá. By the analysis related to the First and Second Thermodynamic Laws applied in this system, was possible to identify the mass flows in each point, energetic efficiency, irreversibility and exergetic efficiency. The components that have the biggest irreversibilities are the gasifier, followed by the internal combustion engine, which should be focused in future improvements. The system efficiency in energetic basis is 51,84% and in exergetic basis is 22,78%. Using the ecologic efficiency methodology was possible to identify the emissions rates, the pollution indicator associated to the combustion of the synthesis gas in the internal combustion engine. The ecologic efficiency considering the energectic analysis is 91,73%, while considering the exergetic analysis, 83,65%. It is concluded that the use of the synthesis gas in a compact cogeneration system is viable from the technical and ecological point of view, making possible to generate energy for isolated communities and promoting the decentralized electricity generation
Resumo:
The materials designed to be used in electroluminescent (EL) devices construction are studied and improved since 1936. Great interests in the development of this kind of devices are mainly due to its low power consumption, flexibility, low cost and easy processing. One class of ELs devices with these characteristics are produced by employing a organic-polymeric/inorganic composite from a conductive polymer blend and an inorganic electroluminescent material (Zn2SiO4:Mn) dispersed in the polymeric matrix. This kind of device operates in d.c. or a.c. potentials, with EL of hundreds candela in the green region of the visible spectrum. However, few studies on the light emission were performed for these devices. In order to characterize devices made from composites, in this work is proposed a method of characterizing the electroluminescence associated with the impedance spectroscopy technique. To implement the technique of impedance spectroscopy was employ an experimental setup consisting of a source of a.c. voltage, an oscilloscope, and a reference resistor. Associated with this system, was use a photo diode and an analog electrometer to characterize the emitted light signal from the sample. The system was implemented allows characterization by impedance spectroscopy in the frequency range from 0.2 Hz up to 2 MHz and voltage amplitudes of 5 mV up to 20 kV. This system permits, at the same time, measurement of the RMS value of the luminance for devices in frequency range from 20 Hz up to 2 MHz. To test the system efficiency, an EL device was characterized showing analogous results to those reported in literature. By doing this, was demonstrated the efficiency of the system for electroluminescence characterization associated with the electrical characterization by impedance spectroscopy, for devices
Resumo:
Conselho Nacional de Desenvolvimento em Pesquisa (CNPq)
Resumo:
This research aimed to develop a Fuzzy inference based on expert system to help preventing lameness in dairy cattle. Hoof length, nutritional parameters and floor material properties (roughness) were used to build the Fuzzy inference system. The expert system architecture was defined using Unified Modelling Language (UML). Data were collected in a commercial dairy herd using two different subgroups (H-1 and H-2), in order to validate the Fuzzy inference functions. The numbers of True Positive (TP), False Positive (FP), True Negative (TN), and False Negative (FN) responses were used to build the classifier system up, after an established gold standard comparison. A Lesion Incidence Possibility (LIP) developed function indicates the chances of a cow becoming lame. The obtained lameness percentage in H-1 and H-2 was 8.40% and 1.77%, respectively. The system estimated a Lesion Incidence Possibility (LIP) of 5.00% and 2.00% in H-1 and H-2, respectively. The system simulation presented 3.40% difference from real cattle lameness data for H-1, while for H-2, it was 0.23%; indicating the system efficiency in decision-making.
Resumo:
This paper introduces a proposal for reservoir volume calculation in rainwater harvesting systems. The proposed method can be used for reservoir volume design in rainwater harvesting systems and is based on three important variables. These variables are water demand, system efficiency and repayment time. Several simulations were carried out in different scenarios considering typical values of both catchment area (for low-income and medium-income households) and water demand, with fixed water and tank costs. Results showed that the integrated analysis of demand, efficiency and repayment time may assist designers to determine a more adequate reservoir volume.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
This work approaches the analysis of industrial refrigeration systems applied to a chemical processing industry that, in this case, consists of refrigeration machines, cooling tower system, cold water system and brine system. In this study it is highlighted the function and characteristics of different systems, including the main components, the most important features, their functionality and best practices. The motivation for this work is the fact that refrigeration systems are essential in many industrial processes, presenting a high energy consumption that is related to a significant parcel of production costs. It has aimed to understand the case studied in order to evaluate the energy efficiency of systems and to compare with Carnot efficiency and best available technologies. The assessment aims to identify irregularities, find opportunities and propose solutions that increases the performance of equipment and the overall system efficiency. Therefore, the studies intend to reduce the operation costs and generate gains for the company
Resumo:
This work approaches the analysis of industrial refrigeration systems applied to a chemical processing industry that, in this case, consists of refrigeration machines, cooling tower system, cold water system and brine system. In this study it is highlighted the function and characteristics of different systems, including the main components, the most important features, their functionality and best practices. The motivation for this work is the fact that refrigeration systems are essential in many industrial processes, presenting a high energy consumption that is related to a significant parcel of production costs. It has aimed to understand the case studied in order to evaluate the energy efficiency of systems and to compare with Carnot efficiency and best available technologies. The assessment aims to identify irregularities, find opportunities and propose solutions that increases the performance of equipment and the overall system efficiency. Therefore, the studies intend to reduce the operation costs and generate gains for the company
Resumo:
Introduction: The lack of reference values of anthropometric, performance, biochemical, hematological, hormonal and psychological parameters is an important limitation in the investigations with soccer players. Objective: To elaborate percentile tables to be used as comparison reference for further studies. Methods: 82 professional soccer players were evaluated approximately 30 days after the beginning of the main competition played by their teams. On the first day of evaluation, fast blood samples were collected for measurement of hematological parameters (i.e. erythrocytes, hemoglobin, hematocrit, mean corpuscular volume - MCV, mean corpuscular hemoglobin - MCH, mean corpuscular hemoglobin concentration - MCHC, leukocytes, eosinophils, lymphocytes, monocytes and platelets) and of concentrations of adrenaline, cortisol, creatine kinase, creatinine, norepinephrine, testosterone and urea. Subsequently, the soccer players had their anthropometric characteristics and psychological parameters assessed. In addition, the evaluation of the lactic anaerobic system efficiency was performed on a 400-m track. On the second day, both the alactic anaerobic and aerobic system efficiency was measured. Results: The percentile distribution (P-0, P-15, P-30, P-50, P-70, P-85 e P-100) was used to present the results. Conclusion: The elaboration of the percentile tables can be used as comparison reference for further studies.