916 resultados para spray nozzles
Resumo:
The objective of this study was to compare the efficiency of washing and trimming broiler carcasses to reduce bacterial contamination. At the poste-visceration site, 100 broiler carcasses were collected during 4 visits to a slaughterhouse in Santa Catarina State, Brazil. Birds were from the same flock, age, and approximately 2.4 kg of weight. Groups were as follows: group 1, with fecal contamination; group 2, without fecal contamination; group 3, with fecal contamination and trimmed; group 4, with fecal contamination and washed; group 5, with fecal contamination, and washed and trimmed. Carcass washings were performed with at least 1.5 L/bird of potable water (0.5 to 1 mg/kg of residual chlorine) at room temperature (20-25 degrees C) using spray cabinets with 44 spray nozzles distributed into 2 chambers (pressure of 2 kgf/cm(2) and 4 kgf/cm(2)). Washed carcasses (trimmed or not) showed significantly (P < 0.05) lower counts of aerobic mesophiles (plate count agar) on the third evaluation, and even lower (P < 0.01) counts for total coliforms (CT) and fecal coliforms (Escherichia coli). Trimmed carcasses showed significantly lower counts (P < 0.05) for plate count agar; however, we observed higher counts for E. coli (P < 0.05). The association of both treatments (washing and trimming) showed significantly higher (P < 0.05) counts for coliforms (CT and E. coli). We can conclude that the washing method is overall more efficient than the trimming method to decontaminate chicken carcasses at the postevisceration site. Hopefully, our findings can help poultry companies to minimize production costs by applying the washing method for carcass decontamination.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Agronomia (Ciência do Solo) - FCAV
Resumo:
The application technology shows many parameters related to the quality of the application, one is the droplet spectrum, which is influenced by the spray nozzles and the adjuvant used. Therefore, the objective of this work was estimate the behavior of the droplet spectrum generated with different nozzles and different adjuvants. The experiment was installed containing four solutions from different type adjuvant dilution, as vegetal oil, mineral oil, surfactant and drift reduction, which were applied with two nozzle, one pre-orifice flat fan (DG 8003 VS) and other of air induction flat fan (AI 8003 VS), totaling 8 treatments with 3 repetitions. The experiment was realized in ideal weather conditions for spraying. The treatments averages were compared using Confidence Interval at 95% probability and the correlations between variables were analyzed using Pearson at 5% of probability. The analysis of droplet spectrum showed different behavior for each adjuvant and nozzle. The surfactant treatment showed VMD superior for all treatments when sprayed with AI nozzles. For the %vol.<100 µm the lowest value found was for the AI nozzle in combination with the surfactant. The significant correlations found for the nozzles AI and DG were negative between VMD and %vol.<100 µm. It can be concluded that the values of DMV and %vol.<100 µm showed that the nozzle with pre-orifice have droplet spectrum more prone to drift. The surfactant showed to be the best drift reduction technique when combined with the AI nozzle.
Resumo:
The Asian rust currently is the main disease of soybean culture, having as characteristics the difficult control, by start at the bottom of plants where penetration of the droplets is harder. The fine droplets has been used with the intention of improve the penetration and increase efficiency of agrochemicals, but that are losses by drift easily. New products have been developed to increase deposition of the drops at targets. The aim of this work was evaluate the TA- 35 capacity to improving the deposition of fungicides spray solution with or without mineral oil by aerial and ground applications. Was used a factorial 3x2, three spray solutions composed by Priori Xtra (concentrated suspension of azoxystrobin 200 g L-1 + cyproconazole 80 g L-1 ) mixed with adjuvants, Nimbus (emulsifiable concentrate containing aliphatic hydrocarbons 428 g L-1 ) and TA-35 (soluble concentrate containing sodium lauryl ether sulfate, surfactants, sequestering agents and emulsifiers), in aerial and ground applications. In ground applications was used 50 L ha-1 , TXA 8002 VS spray nozzles and on aerials was used 15 L ha-1 , Turboaero atomizer, both applying fine droplets. Was utilized the Brilliant Blue (FD & C n. 1) tracer to determine the deposits. There were used glass slides as targets to collect spray droplets. After to extract the tracer of the targets using distilled water, the samples were analyzed by spectrophotometry, thereby was possible quantify the tracer deposited on each glass slide. A study to evaluate possible losses of the tracer by degradation or retention also was done. The comparative analysis of treatments was done by statistical method "Confidence Interval for Differences Between the Averages" with 95% of confidence degree (IC95%). There was degradation or retention of the tracer between the processes of application of the droplets and the processing of the samples. The deposition averages with the presence of TA-35 were greatest for both sprayers however, there were not significant differences among the treatments. The viability of TA-35 use may consider other parameters or complementary studies.
Resumo:
Los procesos relacionados con el almacenamiento y manipulación de productos petrolíferos, conllevan siempre determinados riesgos de incendio que dependen básicamente de las propiedades físicas y químicas de los productos, y hacen indispensable la adopción de importantes medidas de seguridad contra incendios. Esto es debido a que las consecuencias previsibles en caso de la producción y expansión del incendio son tan graves que aconsejan la instalación de medios más potentes de lucha contra incendios, que los simples extintores manuales. En base a ello, el presente proyecto pretende definir y desarrollar una propuesta de diseño del sistema de protección contra incendios en la zona de almacenamiento de una planta de almacenamiento de líquidos petrolíferos. La planta almacena Gasóleo, Gasolina y Queroseno de Aviación en ocho tanques atmosféricos de techo fijo situados en un único cubeto de retención. Se desarrolla un extenso estudio de los requisitos normativos para este tipo de casos, y en consecuencia, se calcula y clasifica el nivel de riesgo intrínseco de incendio en la zona estudiada, a partir de su carga de fuego ponderada y corregida. Además, se muestra la distribución de los tanques en el cubeto, basada en el cálculo de las distancias de seguridad entre cada uno de ellos y con el exterior. A partir de ello, el proyecto se centra en el cálculo de los valores de descarga de agua de refrigeración, requeridos en las boquillas de agua pulverizada e hidrantes exteriores de alrededor de la zona de riesgo; de espuma física para hidrocarburos, en las cámaras de espuma de la parte superior de la envolvente de los tanques, y en los monitores auxiliares de descarga de espuma, de la zona del cubeto de retención. Los objetivos, métodos y bases de cálculo se recogen en la memoria del proyecto. Además se incluye, la planificación temporal con MS Project, de la implementación del proyecto; la elección de los equipos que componen los sistemas, el presupuesto asociado y los planos de distribución de la planta y del flujo de tuberías propuesto. ABSTRACT Fire protection units and equipment are necessary on processes and operations related to storage and handling of petroleum products, because of their flammable and combustible properties. In case a hazard of fire from petroleum products is materialized, huge consequences are to be expected. To reduce losses, facilities should be equipped with appropriate protection. Based on that, this project seeks to define and develop the fire protection system design for a petroleum liquids storage installation. The plant stores Gasoil, Gasoline, and aviation Kerosene in eight fixed roof atmospheric tanks. A complete study of the fire protection regulations is carried out and, as a result, the studied area’s risk level is determined from its fire load density. The calculation of the minimum shell-to-shell spacing of adjacent aboveground storage tanks and external equipment, is also determined for a correct distribution of tanks in the bunded area. Assuming that, the design includes calculations of required discharge of water for spray nozzles and hydrants, and required discharge of foam from foam chambers and foam monitors. Objectives, methodology and calculation basis are presented on the project technical report; which also includes project scheduling with MS. Project software, the selection of system components and equipment, related budget and lay out of installation and piping.
Resumo:
Atualmente, há poucas aplicações de uso de combustíveis renováveis em queimadores, apesar de representarem grande parte do consumo de energia primária. O etanol se apresenta como uma alternativa com grande potencial para substituição de combustíveis não-renováveis em queimadores no Brasil. Tendo em vista este potencial, foi realizado um estudo de possíveis aplicações de queimadores a etanol, com potência inferior a 50 kW, do ponto de vista ambiental, econômico e tecnológico. Foi selecionada uma churrasqueira como a aplicação mais viável. Tendo em vista a necessidade de troca de calor por radiação, foram selecionados queimadores porosos infravermelhos em conjunto com bicos pulverizadores. Durante os testes, a combustão incompleta com gotejamento de combustível se mostrou um problema freqüente. Foi construída uma série de protótipos até se chegar a uma solução final do problema. Este protótipo final, com itens de baixo custo, foi testado avaliando-se potência e emissões, apresentando performance adequada. Foram também estabelecidas diretrizes para desenvolvimento de um produto.
Resumo:
Mode of access: Internet.
Resumo:
The effect of application with different nozzle types and volume rates on spray deposition in the V3 stage of two soybean cultivars was evaluated. The experiments were conducted in the Facultad de Ciencias Agronomicas of the UNESP-Botucatu/SP. The nozzles evaluated were an air induced flat fan nozzle (Al 11015 at 150 L ha(-1), Al 11002 at 200 and 250 L ha(-1)), a twin flat fan nozzle (TJ 60 11002 at 150, 200 and 250 L ha(-1)), and a cone nozzle (TX 6 at 150 L ha(-1), TX 8 at 150 L ha(-1) and TX 10 at 250 L ha(-1)). To evaluate spray deposition on the plants, a tracer (Brilliant Blue FD&C-1) was added. The experimental design was random blocks with four replications. Deposition on plants was determined by absorbancy reading in 630 nm wavelength. The data were adjusted to a calibration curve and transformed into deposited spray volume in mL. The relationship deposition per unit of dry matter was adjusted to a regression curve (Gompertz model). In cultivar CD 208, the highest deposit was for the larger volumes and for the treatment TX 8 200 L ha(-1). The most uniform treatments were all the nozzles with the volume 150 L ha(-1) and the TJ60 nozzle for 200 1, ha(-1). In cultivar CD 216, the greatest spray depositions were achieved with the treatments Al at 200 and 250 L ha(-1) and TJ 60 at 250 L ha(-1), and the most uniform treatments were the TX 6 and TJ60 nozzles for the volume150 L ha(-1).
Resumo:
In the present investigation, two nozzle configurations are used for spray deposition, convergent nozzle (nozzle-A), and convergent nozzle with 2 mm parallel portion attached at its end (nozzle-C) without changing the exit area. First, the conditions for subambient aspiration pressure, i.e., pressure at the tip of the melt delivery tube, are established by varying the protrusion length of the melt delivery tube at different applied gas pressures for both of the nozzles. Using these conditions, spray deposits in a reproducible manner are successfully obtained for 7075 Al alloy. The effect of applied gas pressure, flight distance, and nozzle configuration on various characteristics of spray deposition, viz., yield, melt flow rate, and gas-to-metal ratio, is examined. The over-spray powder is also characterized with respect to powder size distribution, shape, and microstructure. Some of the results are explained with the help of numerical analysis presented in an earlier article.
Resumo:
This paper deals with an experimental study of the breakup characteristics of water emanating from hollow cone hydraulic injector nozzles induced by pressure-swirling. The experiments were conducted using two nozzles with different orifice diameters 0.3 mm and 0.5 mm and injection pressures (0.3-4 MPa) which correspond to Rep = 7000-26 000. Two types of laser diagnostic techniques were utilized: shadowgraph and phase Doppler particle anemometry for a complete study of the atomization process. Measurements that were made in the spray in both axial and radial directions indicate that both velocity and average droplet diameter profiles are highly dependent on the nozzle characteristics, Weber number and Reynolds number. The spatial variation of diameter and velocity arises principally due to primary breakup of liquid films and subsequent secondary breakup of large droplets due to aerodynamic shear. Downstream of the nozzle, coalescence of droplets due to collision was also found to be significant. Different types of liquid film breakup were considered and found to match well with the theory. Secondary breakup due to shear was also studied theoretically and compared to the experimental data. Coalescence probability at different axial and radial locations was computed to explain the experimental results. The spray is subdivided into three zones: near the nozzle, a zone consisting of film and ligament regime, where primary breakup and some secondary breakup take place; a second zone where the secondary breakup process continues, but weakens, and the centrifugal dispersion becomes dominant; and a third zone away from the spray where coalescence is dominant. Each regime has been analyzed in detail, characterized by timescale and Weber number and validated using experimental data. (C) 2012 American Institute of Physics. http://dx.doi.org/10.1063/1.4773065]
Resumo:
This paper deals with an experimental study of pressure-swirl hydraulic injector nozzles using non-intrusive optical techniques. Experiments were conducted to study atomization characteristics using two nozzles with different orifice diameters, 0.3 mm and 0.5 mm, and injection pressures, 0.3-3.5 Mpa, which correspond to Reynolds number (Re-p) = 7,000-45,000, depending on nozzle utilized. Three laser diagnostic techniques were utilized: Shadowgraph, PIV (Particle Image Velocimetry), and PDPA (Phase Doppler Particle Anemometry). Measurements made in the spray in both axial and radial directions indicate that velocity, average droplet diameter profiles, and spray dynamics are highly dependent on the nozzle characteristics and injection pressure. Limitations of these techniques in the different flow regimes, related to the primary and secondary breakups as well as coalescence, are provided. Results indicate that all three techniques provide similar results throughout the different regimes. Shadowgraph and PDPA were possible in the secondary atomization and coalescence regimes while PIV measurements could be made only at the end of secondary atomization and coalescence.
Resumo:
Pressure-swirl nozzles (simplex nozzles) are used in various field applications such as aero-engines, power generation, spray painting and agricultural irrigation. For this particular nozzle, research in the past decade has dealt with the development of numerical models for predicting droplet distribution profiles. Although these results have been valuable, the experimental results have been contradictory, therefore fundamental understanding of the influence of properties in nozzle is important. This paper experimentally investigates the effect of surfactants on breakup and coalescence. Since most of the fuels and biofuels have low surface tension compared to water, a comparative analysis between a surfactant solution and a liquid fuel is imperative. For this experimental study, a simplex nozzle characterized as flow number 0.4 will be utilized. The injection pressures will range from 0.3 - 4Mpa while altering the surface tension from 72 to 28mN/m. By applying Phase Doppler Particle Anemometry (PDPA) which is a non-intrusive laser diagnostic technique, the differences in spray characteristics due to spray surface tension can be highlighted. The average droplet diameter decreases for a low surface tension fluid in the axial direction in comparison to pure water. The average velocity of droplets is surprisingly lower in the same spray zone. Measurements made in the radial direction show no significant changes, but at the locations close to the nozzle, water droplets have larger diameter and velocity. The results indicate the breakup and coalescence regimes have been altered when surface tension is lowered. A decrease in surface tension alters the breakup length while increasing the spray angle. Moreover, higher injection pressure shortens the breakup length and decrease in overall diameter of the droplets. By performing this experimental study the fundamentals of spray dynamics, such as spray formation, liquid breakup length, and droplet breakup regimes can be observed as a function of surface tension and how a surrogate fuel compares with a real fuel for experimental purposes. This knowledge potentially will lead to designing a better atomizer or new biofuels.
Resumo:
The cooling process in conventional rotomolding is relatively long due to poor thermal conductivity of plastics. The lack of internal cooling is a major limitation although rapid external cooling is possible. Various internal cooling methodologies have been studied to reduce the cycle time. These include the use of compressed air, cryogenic liquid nitrogen, chilled water coils, and cryogenic liquid carbon dioxide, all of which have limitations. However, this article demonstrates the use of water spray cooling of polymers as a viable and effective method for internal cooling in rotomolding. To this end, hydraulic, pneumatic, and ultrasonic nozzles were applied and evaluated using a specially constructed test rig to assess their efficiency. The effects of nozzle type and different parametric settings on water droplet size, velocity, and mass flow rate were analyzed and their influence on cooling rate, surface quality, and morphology of polymer exposed to spray cooling were characterized. The pneumatic nozzle provided highest average cooling rate while the hydraulic nozzle gave lowest average cooling rate. The ultrasonic nozzle with medium droplet size traveling at low velocity produced satisfactory surface finish. Water spray cooling produced smaller spherulites compared to ambient cooling whilst increasing the cooling rate decreases the percentage crystallinity. © 2011 Society of Plastics Engineers Copyright © 2011 Society of Plastics Engineers.