938 resultados para source analysis
Resumo:
A major issue in the application of waveform inversion methods to crosshole georadar data is the accurate estimation of the source wavelet. Here, we explore the viability and robustness of incorporating this step into a time-domain waveform inversion procedure through an iterative deconvolution approach. Our results indicate that, at least in non-dispersive electrical environments, such an approach provides remarkably accurate and robust estimates of the source wavelet even in the presence of strong heterogeneity in both the dielectric permittivity and electrical conductivity. Our results also indicate that the proposed source wavelet estimation approach is relatively insensitive to ambient noise and to the phase characteristics of the starting wavelet. Finally, there appears to be little-to-no trade-off between the wavelet estimation and the tomographic imaging procedures.
Resumo:
Pulsewidth-modulated (PWM) rectifier technology is increasingly used in industrial applications like variable-speed motor drives, since it offers several desired features such as sinusoidal input currents, controllable power factor, bidirectional power flow and high quality DC output voltage. To achieve these features,however, an effective control system with fast and accurate current and DC voltage responses is required. From various control strategies proposed to meet these control objectives, in most cases the commonly known principle of the synchronous-frame current vector control along with some space-vector PWM scheme have been applied. Recently, however, new control approaches analogous to the well-established direct torque control (DTC) method for electrical machines have also emerged to implement a high-performance PWM rectifier. In this thesis the concepts of classical synchronous-frame current control and DTC-based PWM rectifier control are combined and a new converter-flux-based current control (CFCC) scheme is introduced. To achieve sufficient dynamic performance and to ensure a stable operation, the proposed control system is thoroughly analysed and simple rules for the controller design are suggested. Special attention is paid to the estimationof the converter flux, which is the key element of converter-flux-based control. Discrete-time implementation is also discussed. Line-voltage-sensorless reactive reactive power control methods for the L- and LCL-type line filters are presented. For the L-filter an open-loop control law for the d-axis current referenceis proposed. In the case of the LCL-filter the combined open-loop control and feedback control is proposed. The influence of the erroneous filter parameter estimates on the accuracy of the developed control schemes is also discussed. A newzero vector selection rule for suppressing the zero-sequence current in parallel-connected PWM rectifiers is proposed. With this method a truly standalone and independent control of the converter units is allowed and traditional transformer isolation and synchronised-control-based solutions are avoided. The implementation requires only one additional current sensor. The proposed schemes are evaluated by the simulations and laboratory experiments. A satisfactory performance and good agreement between the theory and practice are demonstrated.
Resumo:
IIn electric drives, frequency converters are used to generatefor the electric motor the AC voltage with variable frequency and amplitude. When considering the annual sale of drives in values of money and units sold, the use of low-performance drives appears to be in predominant. These drives have tobe very cost effective to manufacture and use, while they are also expected to fulfill the harmonic distortion standards. One of the objectives has also been to extend the lifetime of the frequency converter. In a traditional frequency converter, a relatively large electrolytic DC-link capacitor is used. Electrolytic capacitors are large, heavy and rather expensive components. In many cases, the lifetime of the electrolytic capacitor is the main factor limiting the lifetime of the frequency converter. To overcome the problem, the electrolytic capacitor is replaced with a metallized polypropylene film capacitor (MPPF). The MPPF has improved properties when compared to the electrolytic capacitor. By replacing the electrolytic capacitor with a film capacitor the energy storage of the DC-linkwill be decreased. Thus, the instantaneous power supplied to the motor correlates with the instantaneous power taken from the network. This yields a continuousDC-link current fed by the diode rectifier bridge. As a consequence, the line current harmonics clearly decrease. Because of the decreased energy storage, the DC-link voltage fluctuates. This sets additional conditions to the controllers of the frequency converter to compensate the fluctuation from the supplied motor phase voltages. In this work three-phase and single-phase frequency converters with small DC-link capacitor are analyzed. The evaluation is obtained with simulations and laboratory measurements.
Resumo:
BACKGROUND AND PURPOSE: Information about outcomes in Embolic Stroke of Undetermined Source (ESUS) patients is unavailable. This study provides a detailed analysis of outcomes of a large ESUS population. METHODS: Data set was derived from the Athens Stroke Registry. ESUS was defined according to the Cryptogenic Stroke/ESUS International Working Group criteria. End points were mortality, stroke recurrence, functional outcome, and a composite cardiovascular end point comprising recurrent stroke, myocardial infarction, aortic aneurysm rupture, systemic embolism, or sudden cardiac death. We performed Kaplan-Meier analyses to estimate cumulative probabilities of outcomes by stroke type and Cox-regression to investigate whether stroke type was outcome predictor. RESULTS: 2731 patients were followed-up for a mean of 30.5±24.1months. There were 73 (26.5%) deaths, 60 (21.8%) recurrences, and 78 (28.4%) composite cardiovascular end points in the 275 ESUS patients. The cumulative probability of survival in ESUS was 65.6% (95% confidence intervals [CI], 58.9%-72.2%), significantly higher compared with cardioembolic stroke (38.8%, 95% CI, 34.9%-42.7%). The cumulative probability of stroke recurrence in ESUS was 29.0% (95% CI, 22.3%-35.7%), similar to cardioembolic strokes (26.8%, 95% CI, 22.1%-31.5%), but significantly higher compared with all types of noncardioembolic stroke. One hundred seventy-two (62.5%) ESUS patients had favorable functional outcome compared with 280 (32.2%) in cardioembolic and 303 (60.9%) in large-artery atherosclerotic. ESUS patients had similar risk of composite cardiovascular end point as all other stroke types, with the exception of lacunar strokes, which had significantly lower risk (adjusted hazard ratio, 0.70 [95% CI, 0.52-0.94]). CONCLUSIONS: Long-term mortality risk in ESUS is lower compared with cardioembolic strokes, despite similar rates of recurrence and composite cardiovascular end point. Recurrent stroke risk is higher in ESUS than in noncardioembolic strokes.
Resumo:
The maximum realizable power throughput of power electronic converters may be limited or constrained by technical or economical considerations. One solution to this problemis to connect several power converter units in parallel. The parallel connection can be used to increase the current carrying capacity of the overall system beyond the ratings of individual power converter units. Thus, it is possible to use several lower-power converter units, produced in large quantities, as building blocks to construct high-power converters in a modular manner. High-power converters realized by using parallel connection are needed for example in multimegawatt wind power generation systems. Parallel connection of power converter units is also required in emerging applications such as photovoltaic and fuel cell power conversion. The parallel operation of power converter units is not, however, problem free. This is because parallel-operating units are subject to overcurrent stresses, which are caused by unequal load current sharing or currents that flow between the units. Commonly, the term ’circulatingcurrent’ is used to describe both the unequal load current sharing and the currents flowing between the units. Circulating currents, again, are caused by component tolerances and asynchronous operation of the parallel units. Parallel-operating units are also subject to stresses caused by unequal thermal stress distribution. Both of these problemscan, nevertheless, be handled with a proper circulating current control. To design an effective circulating current control system, we need information about circulating current dynamics. The dynamics of the circulating currents can be investigated by developing appropriate mathematical models. In this dissertation, circulating current models aredeveloped for two different types of parallel two-level three-phase inverter configurations. Themodels, which are developed for an arbitrary number of parallel units, provide a framework for analyzing circulating current generation mechanisms and developing circulating current control systems. In addition to developing circulating current models, modulation of parallel inverters is considered. It is illustrated that depending on the parallel inverter configuration and the modulation method applied, common-mode circulating currents may be excited as a consequence of the differential-mode circulating current control. To prevent the common-mode circulating currents that are caused by the modulation, a dual modulator method is introduced. The dual modulator basically consists of two independently operating modulators, the outputs of which eventually constitute the switching commands of the inverter. The two independently operating modulators are referred to as primary and secondary modulators. In its intended usage, the same voltage vector is fed to the primary modulators of each parallel unit, and the inputs of the secondary modulators are obtained from the circulating current controllers. To ensure that voltage commands obtained from the circulating current controllers are realizable, it must be guaranteed that the inverter is not driven into saturation by the primary modulator. The inverter saturation can be prevented by limiting the inputs of the primary and secondary modulators. Because of this, also a limitation algorithm is proposed. The operation of both the proposed dual modulator and the limitation algorithm is verified experimentally.
Resumo:
Tässä pro gradu -tutkielmassa käsittelen lähde- ja kohdetekstikeskeisyyttä näytelmäkääntämisessä. Tutkimuskohteina olivat käännösten sanasto, syntaksi, näyttämötekniikka, kielikuvat, sanaleikit, runomitta ja tyyli. Tutkimuksen tarkoituksena oli selvittää, näkyykö teoreettinen painopisteen siirtyminen lähdetekstikeskeisyydestä kohdetekstikeskeisyyteen suomenkielisessä näytelmäkääntämisessä. Oletuksena oli, että siirtyminen näkyy käytetyissä käännösstrategioissa. Tutkimuksen teoriaosuudessa käsitellään ensin lähde- ja kohdetekstikeskeisiä käännösteorioita. Ensin esitellään kaksi lähdetekstikeskeistä teoriaa, jotka ovat Catfordin (1965) muodollinen vastaavuus ja Nidan (1964) dynaaminen ekvivalenssi. Kohdetekstikeskeisistä teorioista käsitellään Touryn (1980) ja Newmarkin (1981) teoreettisia näkemyksiä sekä Reiss ja Vermeerin (1986) esittelemää skopos-teoriaa. Vieraannuttamisen ja kotouttamisen periaatteet esitellään lyhyesti. Teoriaosuudessa käsitellään myös näytelmäkääntämistä, William Shakespearen kieltä ja siihen liittyviä käännösongelmia. Lisäksi esittelen lyhyesti Shakespearen kääntämistä Suomessa ja Julius Caesarin neljä kääntäjää. Tutkimuksen materiaalina oli neljä Shakespearen Julius Caesar –näytelmän suomennosta, joista Paavo Cajanderin käännös on julkaistu vuonna 1883, Eeva-Liisa Mannerin vuonna 1983, Lauri Siparin vuonna 2006 ja Jarkko Laineen vuonna 2007. Analyysissa käännöksiä verrattiin lähdetekstiin ja toisiinsa ja vertailtiin kääntäjien tekemiä käännösratkaisuja. Tulokset olivat oletuksen mukaisia. Lähdetekstikeskeisiä käännösstrategioita oli käytetty uusissa käännöksissä vähemmän kuin vanhemmissa. Kohdetekstikeskeiset strategiat erosivat huomattavasti toisistaan ja uusinta käännöstä voi sanoa adaptaatioksi. Jatkotutkimuksissa tulisi materiaali laajentaa koskemaan muitakin Shakespearen näytelmien suomennoksia. Eri aikakausien käännöksiä tulisi verrata keskenään ja toisiinsa, jotta voitaisiin luotettavasti kuvata muutosta lähde- ja kohdetekstikeskeisten käännösstrategioiden käytössä ja eri aikakausien tyypillisten strategioiden kartoittamiseksi.
Resumo:
We transplanted 47 patients with Fanconi anemia using an alternative source of hematopoietic cells. The patients were assigned to the following groups: group 1, unrelated bone marrow (N = 15); group 2, unrelated cord blood (N = 17), and group 3, related non-sibling bone marrow (N = 15). Twenty-four patients (51%) had complete engraftment, which was not influenced by gender (P = 0.87), age (P = 0.45), dose of cyclophosphamide (P = 0.80), nucleated cell dose infused (P = 0.60), or use of anti-T serotherapy (P = 0.20). Favorable factors for superior engraftment were full HLA compatibility (independent of the source of cells; P = 0.007) and use of a fludarabine-based conditioning regimen (P = 0.046). Unfavorable factors were > or = 25 transfusions pre-transplant (P = 0.011) and degree of HLA disparity (P = 0.007). Intensity of mucositis (P = 0.50) and use of androgen prior to transplant had no influence on survival (P = 0.80). Acute graft-versus-host disease (GVHD) grade II-IV and chronic GVHD were diagnosed in 47 and 23% of available patients, respectively, and infections prevailed as the main cause of death, associated or not with GVHD. Eighteen patients are alive, the Kaplan-Meyer overall survival is 38% at ~8 years, and the best results were obtained with related non-sibling bone marrow patients. Three recommendations emerged from the present study: fludarabine as part of conditioning, transplant in patients with <25 transfusions and avoidance of HLA disparity. In addition, an extended family search (even when consanguinity is not present) seeking for a related non-sibling donor is highly recommended.
Resumo:
Simultaneous measurements of EEG-functional magnetic resonance imaging (fMRI) combine the high temporal resolution of EEG with the distinctive spatial resolution of fMRI. The purpose of this EEG-fMRI study was to search for hemodynamic responses (blood oxygen level-dependent - BOLD responses) associated with interictal activity in a case of right mesial temporal lobe epilepsy before and after a successful selective amygdalohippocampectomy. Therefore, the study found the epileptogenic source by this noninvasive imaging technique and compared the results after removing the atrophied hippocampus. Additionally, the present study investigated the effectiveness of two different ways of localizing epileptiform spike sources, i.e., BOLD contrast and independent component analysis dipole model, by comparing their respective outcomes to the resected epileptogenic region. Our findings suggested a right hippocampus induction of the large interictal activity in the left hemisphere. Although almost a quarter of the dipoles were found near the right hippocampus region, dipole modeling resulted in a widespread distribution, making EEG analysis too weak to precisely determine by itself the source localization even by a sophisticated method of analysis such as independent component analysis. On the other hand, the combined EEG-fMRI technique made it possible to highlight the epileptogenic foci quite efficiently.
Resumo:
Multiple regression analysis is a statistical technique which allows to predict a dependent variable from m ore than one independent variable and also to determine influential independent variables. Using experimental data, in this study the multiple regression analysis is applied to predict the room mean velocity and determine the most influencing parameters on the velocity. More than 120 experiments for four different heat source locations were carried out in a test chamber with a high level wall mounted air supply terminal at air change rates 3-6 ach. The influence of the environmental parameters such as supply air momentum, room heat load, Archimedes number and local temperature ratio, were examined by two methods: a simple regression analysis incorporated into scatter matrix plots and multiple stepwise regression analysis. It is concluded that, when a heat source is located along the jet centre line, the supply momentum mainly influences the room mean velocity regardless of the plume strength. However, when the heat source is located outside the jet region, the local temperature ratio (the inverse of the local heat removal effectiveness) is a major influencing parameter.