934 resultados para soft lens


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose To investigate if the accuracy of intraocular pressure (IOP) measurements using rebound tonometry over disposable hydrogel (etafilcon A) contact lenses (CL) is affected by the positive power of the CLs. Methods The experimental group comprised 26 subjects, (8 male, 18 female). IOP measurements were undertaken on the subjects’ right eyes in random order using a Rebound Tonometer (ICare). The CLs had powers of +2.00D and +6.00D. Measurements were taken over each contact lens and also before and after the CLs had been worn. Results The IOP measure obtained with both CLs was significantly lower compared to the value without CLs (t test; p<0.001) but no significant difference was found between the two powers of CLs. Conclusions Rebound tonometry over positive hydrogel CLs leads to a certain degree of IOP underestimation. This result didn’t change for the two positive lenses used in the experiment, despite their large difference in power and therefore in lens thickness. Optometrists should bear this in mind when measuring IOP with the rebound tonometer over plus power contact lenses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose Transient changes in corneal topography associated with soft and conventional or reverse geometry rigid contact lens wear have been well documented; however, only a few studies have examined the influence of scleral contact lens wear upon the cornea. Therefore, in this study, we examined the influence of modern miniscleral contact lenses, which land entirely on the sclera and overlying tissues, upon anterior corneal curvature and optics. Methods Anterior corneal topography and elevation data were acquired using Scheimpflug imaging (Pentacam HR, Oculus) immediately prior to and following 8 hours of miniscleral contact lens wear in 15 young healthy adults (mean age 22 ± 3 years, 8 East Asian, 7 Caucasian) with normal corneae. Corneal diurnal variations were accounted for using data collected on a dedicated measurement day without contact lens wear. Corneal clearance was quantified using an optical coherence tomographer (RS-3000, Nidek) following lens insertion and after 8 hours of lens wear. Results Although corneal clearance was maintained throughout the 8 hour lens wear period, significant corneal flattening (up to 0.08 ± 0.04 mm) was observed, primarily in the superior mid-peripheral cornea, which resulted in a slight increase in against-the-rule corneal astigmatism (mean +0.02/-0.15 x 94 for an 8 mm diameter). Higher order aberration terms of horizontal coma, vertical coma and spherical aberration all underwent significant changes for an 8 mm corneal diameter (p ≤ 0.01), which typically resulted in a decrease in RMS error values (mean change in total higher order RMS -0.035 ± 0.046 µm for an 8 mm diameter). There was no association between the magnitude of change in central or mid-peripheral corneal clearance during lens wear and the observed changes in corneal curvature (p > 0.05). However, Asian participants displayed a significantly greater reduction in corneal clearance (p = 0.04) and greater superior-nasal corneal flattening compared to Caucasians (p = 0.048). Conclusions Miniscleral contact lenses that vault the cornea induce significant changes in anterior corneal surface topography and higher order aberrations following 8 hours of lens wear. The region of greatest corneal flattening was observed in the superior-nasal mid-periphery, more so in Asian participants. Practitioners should be aware that corneal measurements obtained following miniscleral lens removal may mask underlying corneal steepening.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to evaluate the outcome of patients with healed moderate to severe contact lens-associated corneal infectious ulcers who were re-fit with contact lenses. Methods: We retrospectively studied patients who were fit with contact lenses on our service and who had had moderate to severe corneal infectious ulcers associated with previous contact lens use. Six patients were included in the study. Results: Gas permeable contact lenses were fit in five patients, and a soft contact lens was fit in one patient. Successful fit was achieved in all cases and visual acuities were equal to or better than 20/30 in all patients. No significant complications were observed after a mean follow-up of 23 months (range, 6-45 months). Conclusion: In this small series of patients with a history of moderate to severe contact-lens related infectious keratitis, no complications were observed after contact lenses were refit. Contact lens wear in patients with a history of infectious keratitis may be safe and useful in order to achieve visual rehabilitation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dual-beam transient thermal lens studies were carried out in aqueous solutions of rhodamine 6G using 532 nm pulses from a frequency-doubled Nd:YAG laser. The analysis of the observed data showed that the thermal lens method can effectively be utilized to study the nonlinear absorption and aggregation which are taking place in a dye medium.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The aim of this study was to compare a developmental optical coherence tomography (OCT) based contact lens inspection instrument to a widely used geometric inspection instrument (Optimec JCF), to establish the capability of a market focused OCT system. Methods: Measurements of 27 soft spherical contact lenses were made using the Optimec JCF and a new OCT based instrument, the Optimec is830. Twelve of the lenses analysed were specially commissioned from a traditional hydrogel (Contamac GM Advance 49%) and 12 from a silicone hydrogel (Contamac Definitive 65), each set with a range of back optic zone radius (BOZR) and centre thickness (CT) values. Three commercial lenses were also measured; CooperVision MyDay (Stenfilcon A) in −10D, −3D and +6D powers. Two measurements of BOZR, CT and total diameter were made for each lens in temperature controlled saline on both instruments. Results: The results showed that the is830 and JCF measurements were comparable, but that the is830 had a better repeatability coefficient for BOZR (0.065 mm compared to 0.151 mm) and CT (0.008 mm compared to 0.027 mm). Both instruments had similar results for total diameter (0.041 mm compared to 0.044 mm). Conclusions: The OCT based instrument assessed in this study is able to match and improve on the JCF instrument for the measurement of total diameter, back optic zone radius and centre thickness for soft contact lenses in temperature controlled saline.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To examine the objective clinical performance of ‘comfort-enhanced’ daily disposable contact lenses over a 16-h day. Methods: Four contact lenses (Hilafilcon B, Etafilcon A Plus, Nelfilcon A and Nelfilcon A Plus) were evaluated in an investigator masked, open label trial at the end of a week’s bilateral wear. Pre-lens noninvasive tear break-up time (PL-NITBUT), tear prism height, bulbar hyperaemia and ocular surface temperature (OST) were measured with the lens in situ at 8, 12 and 16 h of wear. Results: There was no difference between how many hours the lenses types were worn each day (F = 0.90, p = 0.44). The PL-NITBUT decreased with the duration of daily lens wear (F = 32.0, p < 0.001) and was more stable with Nelfilcon A Plus (F = 6.00, p = 0.002) than with the other lenses evaluated. Bulbar blood vessels increased in coverage (F = 11.5, p < 0.001) but not overall redness (F = 0.0, p = 0.99) with the duration of daily lens wear, but there was no difference between the lenses (p > 0.05). The tear prism height decreased with the duration of daily wear (F = 27.0, p < 0.001) and differed between lenses (F = 2.9, p = 0.04). The OST decreased with the duration of lens wear (F = 119.7, p < 0.001) and was reduced by daily disposable lens wear (F = 7.88, p < 0.001), but did not differ between lenses (F = 0.88, p = 0.45). Conclusions: Objective measures of tear film indicated a difference between the lenses evaluated for PLNITBUT and tear prism height, but not for wearing time or bulbar conjunctival hyperaemia. Therefore clinical benefits of daily disposable ‘comfort enhancing’ contact lenses can be measured, but challenges remain in producing contact lenses that do not compromise anterior eye physiology over the whole day. 2010 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Most published surface wettability data are based on hydrated materials and are dominated by the air-water interface. Water soluble species with hydrophobic domains (such as surfactants) interact directly with the hydrophobic domains in the lens polymer. Characterisation of relative polar and non-polar fractions of the dehydrated material provides an additional approach to surface analysis. Method: Probe liquids (water and diiodomethane) were used to characterise polar and dispersive components of surface energies of dehydrated lenses using the method of Owens and Wendt. A range of conventional and silicone hydrogel soft lenses was studied. The polar fraction (i.e. polar/total) of surface energy was used as a basis for the study of the structural effects that influence surfactant persistence on the lens surface. Results: When plotted against water content of the hydrated lens, polar fraction of surface energy (PFSE) values of the dehydrated lenses fell into two rectilinear bands. One of these bands covered PFSE values ranging from 0.4 to 0.8 and contained only conventional hydrogels, with two notable additions: the plasma coated silicone hydrogels lotrafilcon A and B. The second band covered PFSE values ranging from 0.04 to 0.28 and contained only silicone hydrogels. Significantly, the silicone hydrogel lenses with lowest PFSE values (p<0.15) are found to be prone to lipid deposition duringwear. Additionally, more hydrophobic surfactants were found to be more persistent on lenses with lower PFSE values. Conclusions: Measurement of polar fraction of surface energy provides an importantmechanistic insight into surface interactions of silicone hydrogels.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The recording of visual acuity using the Snellen letter chart is only a limited measure of the visual performance of an eye wearing a refractive aid. Qualitative in addition to quantitative information is required to establish such a parameter: spatial, temporal and photometric aspects must all be incorporated into the test procedure. The literature relating to the correction of ametropia by refractive aids was reviewed. Selected aspects of a comparison between the correction provided by spectacles and contact lenses were considered. Special attention was directed to soft hydrophilic contact lenses. Despite technological advances which have produced physiologically acceptable soft lenses, there still remain associated with this recent form of refractive aid unpredictable visual factors. Several techniques for vision assessment were described, and previous studies of visual performance were discussed. To facilitate the investigation of visual performance in a clinical environment, a new semi-automated system was described: this utilized the presentation of broken ring test stimuli on a television screen. The research project comprised two stages. Initial work was concerned with the validation of the television system, including the optimization of its several operational variables. The second phase involved the utilization of the system in an investigation of visual performance aspects of the first month of regular daily soft contact lens wear by experimentally-naive subjects. On the basis of the results of this work an ‘homoeostatic’ model has been proposed to represent the strategy which an observer adopts in order to optimize his visual performance with soft contact lenses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Soft contact lenses for continuous wear require the use of cleaning regimes which utilise hydrogen peroxide systems or multipurpose cleaning solutions (MPS). The compositions of MPS are becoming increasingly complex and often include disinfectants, cleaning agents, preservatives, wetting agents, demulcents, chelating and buffering agents. Recent research on solution–lens interactions has focused on specific ocular parameters such as corneal staining. However the effect of a solution on the lens, particularly silicone hydrogel lenses, itself has received less attention. The purpose of this work was to establish and understand the effects that care solutions have on selected bulk and surface material properties. Methods: Selected bulk and surface properties of each material (etafilcon A, vifilcon A, balafilcon A, senofilcon A, lotrafilcon A and lotrafilcon B, galyfilcon A) were measured after a 24 h soak in a variety of care solutions. Additionally the lenses were soaked for 24 h in hyperosmolar (680 mOsm L-1) and hyposmolar (170 mOsm L-1) PBS. A bulk property parameter the total diameter (TD) was measured using an Optimec contact lens analyser. The surface property related CoF of soaked lenses was measured on a nano-tribometer with conditions of load 30 mN, at a distance of 20 mm and speed 30 mm/min. Results: In terms of bulk properties, change is related to the EWC of the lens, the higher the EWC of the lens the greater the TD changes. Silicone hydrogel lenses have EWCs of <47% and little or no TD changes were observed; lotrafilcon A exhibited no change irrespective of the cleaning solution. Conventional contact lenses have higher EWCs (58% for etafilcon A and 55% for vifilcon A) and the TD was seen to change to a greater extent, for example the etafilcon A material in ReNu MPS had an increase to 14.45± 0.07 mm from the cited 14.2 mm. Other lenses increased or decreased in TD depending on the solution used. The osmolarity of the solution although important is not the only factor governing change in the TD, for example soaking senofilcon A in hyperosmolar PBS (680 mOsm L-1) for 24 h increased the TD of the lens (+0.25 ± 0.07 mm), however when the same lens type was soaked for 24 h in a MPS with a lower osmolarity there was a similar effect. Biotribology measurements demonstrated that some solution–lens combinations can reduce the CoF by 55%, when compared with biotribology with the native packing solution. An increase in the CoF was observed for other solution–lens combinations. Conclusions: There is a dramatic difference in bulk and surface performance of specific lens materials with particular care solutions. Individual components of the care solutions have effects on the bulk and surface properties of contact lenses. The affects are not as great with the silicone hydrogel as compared with conventional hydrogels.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

What is meant by the term ‘specialist contact lens fitting’? Or put another way, what would be considered non-specialist contact lens fitting? Is there such a thing as routine contact lens fitting? Soft or silicone hydrogel fitting for daily wear would probably be considered as routine contact lens fitting, but would extended or flexible wear remain in the same category or would they be considered a specialist fit? Different eras will classify different products as being ‘specialist’. Certainly twenty years ago soft toric contact lenses were considered as being speciality lenses but today would be thought of as routine lenses. Conversely, gas permeable lenses were thought of as mainstream twenty years ago but now are considered as speciality lenses. Although this would not be the same globally, as in some countries (such as Netherlands, France and Japan) gas permeable lens fitting remains popular and is not on the decline as in other countries (Canada, Australia and Sweden) [1]. Bandage soft lenses applied after surface laser refractive procedures would be considered as therapeutic lenses but in reality they are just plano thin hydrogel lenses worn constantly for 3–4 days to allow the underlying epithelium to convalesce and are then removed [2]. Some patients find that wearing hydrogel lenses during periods when they suffer from seasonal allergies actually improves their ocular comfort as the contact lens acts as a barrier to the allergen [3] and [4]. Scleral lenses have long been considered speciality lenses, apart from a time when they were the only lenses available but at that time all contact lens work would have been considered speciality practice! Nowadays we see the advent of mini-scleral designs and we see large diameter gas permeable lenses too. It is possible that these lenses increase the popularity of gas permeable lenses again and they become more main stream. So it would seem that the lines between routine and speciality contact lens fitting are not clear. Whether a lens is classed a specialist fit or not would depend on the lens type, why it was fitted, where in the world the fitting was being done and even the era in which it was fitted. This begs the question as to what would be considered entry level knowledge in contact lens fitting. This may not be an issue for most BCLA members or CLAE readers but certainly would be for bodies such as the College of Optometrists (UK) or the Association of British Dispensing Opticians when they are planning the final registration examinations for budding practitioners or when planning the level of higher level qualifications such as College Certificates or Diplomas. Similarly for training institutions when they are planning their course content. This becomes even trickier when trying to devise a qualification that spans across many countries, like the European Diploma in Optometry and Optics. How do we know if the training and examination level is correct? One way would be to analyse things when they go wrong and if patterns of malpractice are seen then maybe that could be used as an indicator to more training being needed. There were 162 Fitness to Practice Hearing at the General Optical Council between 2001 and 2010. Forty-seven of these were clinically related case, 39 fraud related, and 76 others. Of the clinical ones only 3 were contact lens related. So it would appear that as whole, in the profession, contact lens clinical skills are not being questioned too often (although it seems a few of us can’t keep our hands out the cookie jar!).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Polyvinyl alcohol (PVA) is a successful tear film stabiliser and is widely used in comfort drops and some soft contact lens materials. A PVA-containing lens, nelfilcon A has been modified to include additional (non-functional) PVA in order to provide improved comfort. This study aims to examine the clinical performance of this nelfilcon A lens with AquaRelease™ (AquaRelease). Methods: Two contralateral, investigator masked, open label, subjective and objective evaluations were conducted. The first examined the effect of adding increased molecular weight PVA to nelfilcon A (n = 5), and the second compared this AquaRelease lens to ocufilcon B (n = 34). The principal measures were non-invasive break-up time (NIBUT) and subjective comfort, which were assessed at the beginning and end of a week of daily wear, and three times throughout 1 day at 8, 12 and 16 h. Results: All subjects successfully completed the daily wearing schedule of 16 h. On initial insertion, subjective comfort and NIBUT improved for AquaRelease than original nelfilcon A lenses (p < 0.05). Initial comfort was better for AquaRelease compared to ocufilcon B lenses (p = 0.01); however, NIBUT was not statistically different (11.7 ± 15.6 s versus 8.4 ± 6.8 s; p = 0.26). Subjective comfort decreased with time (p < 0.001), but there was no significant difference between AquaRelease and ocufilcon B lenses (p = 0.16). NIBUT was not significantly affected by time (p = 0.56) or between lenses (p = 0.33). At the end of a weeks' wear, subjective initial, end-of-day, overall comfort and vision were rated significantly better with AquaRelease than ocufilcon B (p < 0.01). Conclusions: Release of additional non-functionalised PVA from the nelfilcon A lenses appears to enhance comfortable contact lens wear. © 2006 British Contact Lens Association.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim: To determine the dynamic emitted temperature changes of the anterior eye during and immediately after wearing different materials and modalities of soft contact lenses. Method: A dynamic, non-contact infrared camera (Thermo-Tracer TH7102MX, NEC San-ei) was used to record the ocular surface temperature (OST) in 48 subjects (mean age 21.7 ± 1.9 years) wearing: lotrafilcon-A contact lenses on a daily wear (LDW; n = 8) or continuous wear (LCW; n = 8) basis; balafilcon-A contact lenses on a daily wear (BDW; n = 8) or continuous wear (BCW; n = 8) basis; etafilcon-A contact lenses on a daily disposable regimen (EDW; n = 8); and no lenses (controls; n = 8). OST was measured continuously five times, for 8 s after a blink, following a minimum of 2 h wear and immediately following lens removal. Absolute temperature, changes in temperature post-blink and the dynamics of temperature changes were calculated. Results: OST immediately following contact lens wear was significantly greater compared to non-lens wearers (37.1 ± 1.7 °C versus 35.0 ± 1.1 °C; p < 0.005), predominantly in the LCW group (38.6 ± 1.0 °C; p < 0.0001). Lens surface temperature was highly correlated (r = 0.97) to, but lower than OST (by -0.62 ± 0.3 °C). There was no difference with modality of wear (DW 37.5 ± 1.6 °C versus CW 37.8 ± 1.9 °C; p = 0.63), but significant differences were found between etafilcon A and silicone hydrogel lens materials (35.3 ± 1.1 °C versus 37.5 ± 1.5 °C; p < 0.0005). Ocular surface cooling following a blink was not significantly affected by contact lens wear with (p = 0.07) or without (p = 0.47) lenses in situ. Conclusions: Ocular surface temperature is greater with hydrogel and greater still with silicone hydrogel contact lenses in situ, regardless of modality of wear. The effect is likely to be due to the thermal transmission properties of a contact lens. © 2004 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To compare lens orientation and rotational recovery of five currently available soft toric lenses. Methods: Twenty subjects were recruited and trialed with each of the study lenses in a random order. Study lenses were PureVision® Toric (B&L), Air Optix® for Astigmatism (Alcon), Biofinity® Toric (CooperVision), Acuvue® Advance for Astigmatism (Vistakon), and Proclear® Toric (CooperVision). Lens orientation in primary position to determine the lens rotation form the vertical position and rotational recovery to primary gaze orientation following a 45° manual misorientation for the different lenses was compared. Results: The Biofinity Toric showed the lowest rotation from the vertical position and the Proclear Toric the highest. Also, the highest and the lowest reorientation speed were related to the Biofinity Toric and the Acuvue Advance for Astigmatism, respectively. The Repeated Measures ANOVA showed a significant difference in the lens rotation (P=. 0.004) and rotational recovery (P<. 0.001) among different contact lenses and the performed multiple comparisons indicated differences in rotation and also in reorientation speed were only seen between the Biofinity Toric when compared to four other lenses (P<. 0.05). Conclusion: Although there was appropriate fitting, based upon lens orientation and reorientation speed, with each of the study lenses it would appear that the optimized ballast technique used in the design of the Biofinity Toric helps reduce lens rotation and improve rotational recovery compared to others.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: This study investigated how aberration-controlling, customised soft contact lenses corrected higher-order ocular aberrations and visual performance in keratoconic patients compared to other forms of refractive correction (spectacles and rigid gas-permeable lenses). Methods: Twenty-two patients (16 rigid gas-permeable contact lens wearers and six spectacle wearers) were fitted with standard toric soft lenses and customised lenses (designed to correct 3rd-order coma aberrations). In the rigid gas-permeable lens-wearing patients, ocular aberrations were measured without lenses, with the patient's habitual lenses and with the study lenses (Hartmann-Shack aberrometry). In the spectacle-wearing patients, ocular aberrations were measured both with and without the study lenses. LogMAR visual acuity (high-contrast and low-contrast) was evaluated with the patient wearing their habitual correction (of either spectacles or rigid gas-permeable contact lenses) and with the study lenses. Results: In the contact lens wearers, the habitual rigid gas-permeable lenses and customised lenses provided significant reductions in 3rd-order coma root-mean-square (RMS) error, 3rd-order RMS and higher-order RMS error (p ≤ 0.004). In the spectacle wearers, the standard toric lenses and customised lenses significantly reduced 3rd-order RMS and higher-order RMS errors (p ≤ 0.005). The spectacle wearers showed no significant differences in visual performance measured between their habitual spectacles and the study lenses. However, in the contact lens wearers, the habitual rigid gas-permeable lenses and standard toric lenses provided significantly better high-contrast acuities compared to the customised lenses (p ≤ 0.006). Conclusions: The customised lenses provided substantial reductions in ocular aberrations in these keratoconic patients; however, the poor visual performances achieved with these lenses are most likely to be due to small, on-eye lens decentrations. © 2014 The College of Optometrists.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To compare monochromatic aberrations of keratoconic eyes when uncorrected, corrected with spherically-powered RGP (rigid gas-permeable) contact lenses and corrected using simulations of customised soft contact lenses for different magnitudes of rotation (up to 15°) and translation (up to 1mm) from their ideal position. Methods: The ocular aberrations of examples of mild, moderate and severe keratoconic eyes were measured when uncorrected and when wearing their habitual RGP lenses. Residual aberrations and point-spread functions of each eye were simulated using an ideal, customised soft contact lens (designed to neutralise higher-order aberrations, HOA) were calculated as a function of the angle of rotation of the lens from its ideal orientation, and its horizontal and vertical translation. Results: In agreement with the results of other authors, the RGP lenses markedly reduced both lower-order aberrations and HOA for all three patients. When compared with the RGP lens corrections, the customised lens simulations only provided optical improvements if their movements were constrained within limits which appear to be difficult to achieve with current technologies. Conclusions: At the present time, customised contact lens corrections appear likely to offer, at best, only minor optical improvements over RGP lenses for patients with keratoconus. If made in soft materials, however, these lenses may be preferred by patients in term of comfort. © 2012 The College of Optometrists.