981 resultados para small animal imaging
Resumo:
The low-energy β− emitter 161Tb is very similar to 177Lu with respect to half-life, beta energy and chemical properties. However, 161Tb also emits a significant amount of conversion and Auger electrons. Greater therapeutic effect can therefore be expected in comparison to 177Lu. It also emits low-energy photons that are useful for gamma camera imaging. The 160Gd(n,γ)161Gd→161Tb production route was used to produce 161Tb by neutron irradiation of massive 160Gd targets (up to 40 mg) in nuclear reactors. A semiautomated procedure based on cation exchange chromatography was developed and applied to isolate no carrier added (n.c.a.) 161Tb from the bulk of the 160Gd target and from its stable decay product 161Dy. 161Tb was used for radiolabeling DOTA-Tyr3-octreotate; the radiolabeling profile was compared to the commercially available n.c.a. 177Lu. A 161Tb Derenzo phantom was imaged using a small-animal single-photon emission computed tomography camera. Up to 15 GBq of 161Tb was produced by long-term irradiation of Gd targets. Using a cation exchange resin, we obtained 80%–90% of the available 161Tb with high specific activity, radionuclide and chemical purity and in quantities sufficient for therapeutic applications. The 161Tb obtained was of the quality required to prepare 161Tb–DOTA-Tyr3-octreotate. We were able to produce 161Tb in n.c.a. form by irradiating highly enriched 160Gd targets; it can be obtained in the quantity and quality required for the preparation of 161Tb-labeled therapeutic agents.
Resumo:
A 20-month-old, female French bulldog was presented with a three-month history of generalised seizures and progressive ataxia with occasional falling over on either side. Neurological examination revealed signs, suggesting a multifocal intracranial lesion. Magnetic resonance imaging of the brain revealed two connected lesions on the left side of the caudal brainstem and a further lesion in the cerebrum. The dog was euthanased, and histopathological examination revealed lesions which closely resembled those of necrotising encephalitis in Yorkshire terriers. This is the first case describing this type of necrotising encephalitis in a French bulldog.
Resumo:
A five-year-old, entire, male dachshund was presented with a five day history of hypersalivation and regurgitation as well as polyuria and polydipsia for several months. Chest radiographs demonstrated megaoesophagus and aspiration pneumonia. Furthermore, hyperadrenocorticism was demonstrated by means of elevations in levels of serum alkaline phosphatase and cholesterol, decreased urinary specific gravity, increased response to adrenocorticotropic hormone stimulation, insufficient suppression of the post-dexamethasone plasma cortisol levels, an increased endogenous adrenocorticotropic hormone concentration and bilaterally enlarged adrenal glands on abdominal ultrasound. The dog became severely dyspnoeic and was euthanased after magnetic resonance imaging was performed. The magnetic resonance imaging and necropsy revealed the sellar region mainly filled with fluid, with only small tissue remnants, a condition defined as empty sella syndrome in human medicine. To the author's knowledge, this is the first dog described with empty sella syndrome and only the second dog described with hyperadrenocorticism secondary to ectopic adrenocorticotropic hormone production. However, the association between empty sella syndrome and hyperadrenocorticism may be no more than incidental.
Resumo:
Three Bavarian mountain dogs aged between 18 and 20 months, not related to each other, were presented with chronic signs of cerebellar dysfunction. On sagittal T2-weighted magnetic resonance imaging brain images, the tentative diagnosis of cerebellar hypoplasia was established based on an enlarged cerebrospinal fluid space around the cerebellum and an increased cerebrospinal fluid signal between the folia. Post-mortem examination was performed in one dog and did show an overall reduction of cerebellar size. On histopathologic examination, a selective loss of cerebellar granule cells with sparing of Purkinje cells was evident. Therefore, the Bavarian mountain dog is a breed where cerebellar cortical degeneration caused by the rather exceptional selective granule cell loss can be seen as cause of chronic, slowly progressive cerebellar dysfunction starting at an age of several months.
Resumo:
OBJECTIVES This case series describes 5 dogs with small intestinal intussusception and acute kidney injury due to infection with Leptospira interrogans serovar Australis. CASE SERIES SUMMARY Small intestinal intussusception was observed in 4 dogs diagnosed with acute kidney injury due to leptospirosis presented between 1997 and 2005. Intussusception was diagnosed at initial presentation or later during hospitalization. An additional dog fulfilling our inclusion criteria was presented to a small animal specialty clinic nearby and was included. Upon admission, all dogs were severely azotemic and thrombocytopenic. All 5 dogs showed the strongest microscopic agglutination test serology reaction to L. interrogans serovar Australis. Two dogs survived with no apparent residual renal damage, 1 survived with subsequent mild chronic kidney disease, and 2 dogs were euthanized at the owners' request due to a guarded prognosis. NEW OR UNIQUE INFORMATION PROVIDED Intussusception can occur or may be seen in dogs with leptospirosis due to L. interrogans serovar Australis and patients should be monitored closely for this potential complication. As all 5 dogs described in this case series showed the highest titer for L. interrogans serovar Australis, these precautions may be especially applied in geographic areas where this particular serovar is seen.
Resumo:
O sistema microPET/CT é um importante equipamento utilizado nas pesquisas de imagem diagnóstica em pequenos animais. O radiofármaco mais usado nesta tecnologia é o fluordeoxiglicose marcado com flúor-18. Este estudo tem como objetivo efetuar o controle radiológico no laboratório de pesquisa microPET/CT do Centro de Radiofarmácia do IPEN-CNEN/SP, de forma a satisfazer tanto as normas nacionais como as recomendações internacionais. O laboratório está classificado pela equipe de radioproteção da instalação como área supervisionada, nas quais embora não seja obrigatória a adoção de medidas específicas de proteção e segurança, devem ser submetidas reavaliações regulares das condições do ambiente de trabalho. Visando assegurar a proteção radiológica dos trabalhadores diretamente envolvidos no manuseio do equipamento, realizou-se o monitoramento do local de trabalho e a avaliação do controle de dose individual. Inicialmente foi feito o monitoramento pré-operacional, isto é, o levantamento radiométrico no laboratório. Além disso, mediu-se nível de radiação externa nas instalações do laboratório e suas adjacências, por meio da colocação de nove dosímetros termoluminescentes (TL) de CaSO4:Dy, em locais previamente selecionados. Os indivíduos ocupacionalmente expostos foram avaliados mensalmente por meio do uso de dosímetros TL posicionados no tórax e por medidas de corpo inteiro, tomadas a cada seis meses. O período do estudo foi de dois anos, com início em abril de 2014. Para o controle do microPET/CT realizou-se testes de desempenho de acordo com o protocolo padrão do equipamento e em conformidade com a norma desenvolvida pela força tarefa para estudos com PET em animais Animal PET Standard Task Force. O presente estudo permitiu demonstrar que os níveis de radiação das áreas (estimativas de dose ambiente e dose efetiva), assim como a blindagem do equipamento estão adequados de acordo com os limites da exposição ocupacional. Ressalta-se a importância de se seguir rigorosamente os princípios de radioproteção, já que se trata de pesquisas com fontes radioativas não seladas.
Resumo:
Thesis (Ph.D.)--University of Washington, 2016-06
Resumo:
Abstract
The goal of modern radiotherapy is to precisely deliver a prescribed radiation dose to delineated target volumes that contain a significant amount of tumor cells while sparing the surrounding healthy tissues/organs. Precise delineation of treatment and avoidance volumes is the key for the precision radiation therapy. In recent years, considerable clinical and research efforts have been devoted to integrate MRI into radiotherapy workflow motivated by the superior soft tissue contrast and functional imaging possibility. Dynamic contrast-enhanced MRI (DCE-MRI) is a noninvasive technique that measures properties of tissue microvasculature. Its sensitivity to radiation-induced vascular pharmacokinetic (PK) changes has been preliminary demonstrated. In spite of its great potential, two major challenges have limited DCE-MRI’s clinical application in radiotherapy assessment: the technical limitations of accurate DCE-MRI imaging implementation and the need of novel DCE-MRI data analysis methods for richer functional heterogeneity information.
This study aims at improving current DCE-MRI techniques and developing new DCE-MRI analysis methods for particular radiotherapy assessment. Thus, the study is naturally divided into two parts. The first part focuses on DCE-MRI temporal resolution as one of the key DCE-MRI technical factors, and some improvements regarding DCE-MRI temporal resolution are proposed; the second part explores the potential value of image heterogeneity analysis and multiple PK model combination for therapeutic response assessment, and several novel DCE-MRI data analysis methods are developed.
I. Improvement of DCE-MRI temporal resolution. First, the feasibility of improving DCE-MRI temporal resolution via image undersampling was studied. Specifically, a novel MR image iterative reconstruction algorithm was studied for DCE-MRI reconstruction. This algorithm was built on the recently developed compress sensing (CS) theory. By utilizing a limited k-space acquisition with shorter imaging time, images can be reconstructed in an iterative fashion under the regularization of a newly proposed total generalized variation (TGV) penalty term. In the retrospective study of brain radiosurgery patient DCE-MRI scans under IRB-approval, the clinically obtained image data was selected as reference data, and the simulated accelerated k-space acquisition was generated via undersampling the reference image full k-space with designed sampling grids. Two undersampling strategies were proposed: 1) a radial multi-ray grid with a special angular distribution was adopted to sample each slice of the full k-space; 2) a Cartesian random sampling grid series with spatiotemporal constraints from adjacent frames was adopted to sample the dynamic k-space series at a slice location. Two sets of PK parameters’ maps were generated from the undersampled data and from the fully-sampled data, respectively. Multiple quantitative measurements and statistical studies were performed to evaluate the accuracy of PK maps generated from the undersampled data in reference to the PK maps generated from the fully-sampled data. Results showed that at a simulated acceleration factor of four, PK maps could be faithfully calculated from the DCE images that were reconstructed using undersampled data, and no statistically significant differences were found between the regional PK mean values from undersampled and fully-sampled data sets. DCE-MRI acceleration using the investigated image reconstruction method has been suggested as feasible and promising.
Second, for high temporal resolution DCE-MRI, a new PK model fitting method was developed to solve PK parameters for better calculation accuracy and efficiency. This method is based on a derivative-based deformation of the commonly used Tofts PK model, which is presented as an integrative expression. This method also includes an advanced Kolmogorov-Zurbenko (KZ) filter to remove the potential noise effect in data and solve the PK parameter as a linear problem in matrix format. In the computer simulation study, PK parameters representing typical intracranial values were selected as references to simulated DCE-MRI data for different temporal resolution and different data noise level. Results showed that at both high temporal resolutions (<1s) and clinically feasible temporal resolution (~5s), this new method was able to calculate PK parameters more accurate than the current calculation methods at clinically relevant noise levels; at high temporal resolutions, the calculation efficiency of this new method was superior to current methods in an order of 102. In a retrospective of clinical brain DCE-MRI scans, the PK maps derived from the proposed method were comparable with the results from current methods. Based on these results, it can be concluded that this new method can be used for accurate and efficient PK model fitting for high temporal resolution DCE-MRI.
II. Development of DCE-MRI analysis methods for therapeutic response assessment. This part aims at methodology developments in two approaches. The first one is to develop model-free analysis method for DCE-MRI functional heterogeneity evaluation. This approach is inspired by the rationale that radiotherapy-induced functional change could be heterogeneous across the treatment area. The first effort was spent on a translational investigation of classic fractal dimension theory for DCE-MRI therapeutic response assessment. In a small-animal anti-angiogenesis drug therapy experiment, the randomly assigned treatment/control groups received multiple fraction treatments with one pre-treatment and multiple post-treatment high spatiotemporal DCE-MRI scans. In the post-treatment scan two weeks after the start, the investigated Rényi dimensions of the classic PK rate constant map demonstrated significant differences between the treatment and the control groups; when Rényi dimensions were adopted for treatment/control group classification, the achieved accuracy was higher than the accuracy from using conventional PK parameter statistics. Following this pilot work, two novel texture analysis methods were proposed. First, a new technique called Gray Level Local Power Matrix (GLLPM) was developed. It intends to solve the lack of temporal information and poor calculation efficiency of the commonly used Gray Level Co-Occurrence Matrix (GLCOM) techniques. In the same small animal experiment, the dynamic curves of Haralick texture features derived from the GLLPM had an overall better performance than the corresponding curves derived from current GLCOM techniques in treatment/control separation and classification. The second developed method is dynamic Fractal Signature Dissimilarity (FSD) analysis. Inspired by the classic fractal dimension theory, this method measures the dynamics of tumor heterogeneity during the contrast agent uptake in a quantitative fashion on DCE images. In the small animal experiment mentioned before, the selected parameters from dynamic FSD analysis showed significant differences between treatment/control groups as early as after 1 treatment fraction; in contrast, metrics from conventional PK analysis showed significant differences only after 3 treatment fractions. When using dynamic FSD parameters, the treatment/control group classification after 1st treatment fraction was improved than using conventional PK statistics. These results suggest the promising application of this novel method for capturing early therapeutic response.
The second approach of developing novel DCE-MRI methods is to combine PK information from multiple PK models. Currently, the classic Tofts model or its alternative version has been widely adopted for DCE-MRI analysis as a gold-standard approach for therapeutic response assessment. Previously, a shutter-speed (SS) model was proposed to incorporate transcytolemmal water exchange effect into contrast agent concentration quantification. In spite of richer biological assumption, its application in therapeutic response assessment is limited. It might be intriguing to combine the information from the SS model and from the classic Tofts model to explore potential new biological information for treatment assessment. The feasibility of this idea was investigated in the same small animal experiment. The SS model was compared against the Tofts model for therapeutic response assessment using PK parameter regional mean value comparison. Based on the modeled transcytolemmal water exchange rate, a biological subvolume was proposed and was automatically identified using histogram analysis. Within the biological subvolume, the PK rate constant derived from the SS model were proved to be superior to the one from Tofts model in treatment/control separation and classification. Furthermore, novel biomarkers were designed to integrate PK rate constants from these two models. When being evaluated in the biological subvolume, this biomarker was able to reflect significant treatment/control difference in both post-treatment evaluation. These results confirm the potential value of SS model as well as its combination with Tofts model for therapeutic response assessment.
In summary, this study addressed two problems of DCE-MRI application in radiotherapy assessment. In the first part, a method of accelerating DCE-MRI acquisition for better temporal resolution was investigated, and a novel PK model fitting algorithm was proposed for high temporal resolution DCE-MRI. In the second part, two model-free texture analysis methods and a multiple-model analysis method were developed for DCE-MRI therapeutic response assessment. The presented works could benefit the future DCE-MRI routine clinical application in radiotherapy assessment.
Resumo:
Intermittent low-dose heparinised saline flushes were found to be efficacious for maintaining patency of indwelling peripheral and central intravenous catheters in diabetic dogs. The catheters were flushed with 1 mL of 1 U/mL heparinised saline every two hours immediately following blood sample collection, or every 12 hours when not being used for sampling. Central catheters were flushed with saline solution first to clear the line before instillation of the heparinised saline. Patency of 54/57 (95%) of the peripheral catheters and 30/32 (94%) of the central catheters was achieved for up to 36 hours and five days, respectively. No phlebitis, or local or systemic infections were observed and, in each case, catheter failure was attributable to obstruction or extravasation. It is unlikely that there will be any contraindications to this flushing technique and its introduction may improve intravenous catheter survival and reduce catheter-associated complications in hospitalised dogs.
Resumo:
Methods: Six adult mixed breed dogs (two males and four females) weighing 7 to 14 kg (10 center dot 5 +/- 1 center dot 5 kg) and aged two to five years were used. Each dog received both treatments in random order: levobupivacaine alone (LBA; n=6) or levobupivacaine plus hyaluronidase (LBH; n=6) administered in the lumbosacral epidural space. Systemic effects, spread and duration of anaesthesia and motor block were determined before treatment and at predetermined intervals. Results: The duration of local anaesthesia was 90 +/- 10 minutes (P=0 center dot 001) for LBH treatment and 150 +/- 15 minutes for LBA treatment. In the LBH treatment, anaesthesia reached the T12 to T13 dermatome and in the LBA treatment it reached the T11 to T12 dermatome in all animals in 5 and 15 minutes, respectively. Complete motor blockade was 75 +/- 12 minutes (P=0 center dot 01) and 120 +/- 15 minutes for LBH and LBA treatments, respectively. Clinical Significance: Hyaluronidase added to levobupivacaine significantly shortens the duration of epidural anaesthesia with the same dermatome spread into the epidural space in dogs.
Resumo:
Introduction. Lung transplantation has become the mainstay therapy for patients with end-stage lung disease refractory to medical management. However, the number of patients listed for lung transplantation largely exceeds available donors. The study of lung preservation requires accurate, cost-effective small animal models. We have described a model of ex vivo rat lung perfusion using a commercially available system. Methods. Male Wistar rats weighing 250 g-300 g were anesthetized with intraperitoneal sodium thiopental (50 mg/kg body weight). The surgical technique included heart-lung block extraction, assembly, and preparation for perfusion and data collection. We used an IL-2 Isolated Perfused Rat or Guinea Pig Lung System (Harvard Apparatus, Holliston, Mass, United States; Hugo Sachs Elektronik, Alemanha). Results. Preliminary results included hemodynamic and pulmonary mechanics data gathered in the experiments. Conclusion. The isolated rat lung perfusion system is a reliable method to assess lung preservation.
Resumo:
This article serves as a quick reference for hyperkalemia. Guidelines for analysis and causes, signs, and a stepwise approach are presented.
Resumo:
This article serves as a quick reference for hypokalemia. Guidelines for analysis and causes, signs, and a stepwise approach are presented.
Resumo:
Diagnosis involves a complex and overlapping series of steps, each of which may be a source of error and of variability between clinicians. This variation may involve the ability to elicit relevant information from the client or animal, in the accuracy, objectivity and completeness of relevant memory stores, and in psychological attributes including tolerance for uncertainty and willingness to engage in constructive self-criticism. The diagnostic acumen of an individual clinician may not be constant, varying with external and personal factors, with different clients and cases, and with the use made of tests. In relation to clients, variations may occur in the ability to gain their confidence, to ask appropriate questions and to evaluate accurately both verbal and nonverbal responses. Tests may introduce problems of accuracy, validity, sensitivity, specificity, interpretation and general appropriateness for the case. Continuing effectiveness as a diagnostician therefore requires constant attention to the maintenance of adequate and up-to-date skills and knowledge relating to the animals and their diseases and to tests, and of sensitive interpersonal skills.