904 resultados para sinus rhythm
Resumo:
BACKGROUND Functional characterization of mutations involving the SCN5A-encoded cardiac sodium channel has established the pathogenic mechanisms for type 3 long QT syndrome and type 1 Brugada syndrome and has provided key insights into the physiological importance of essential structure-function domains. OBJECTIVE This study sought to present the clinical and biophysical phenotypes discerned from compound heterozygosity mutations in SCN5A on different alleles in a toddler diagnosed with QT prolongation and fever-induced ventricular arrhythmias. METHODS A 22-month-old boy presented emergently with fever and refractory ventricular tachycardia. Despite restoration of sinus rhythm, the infant sustained profound neurological injury and died. Using polymerase chain reaction, denaturing high-performance liquid chromatography, and direct DNA sequencing, comprehensive open-reading frame/splice mutational analysis of the 12 known long QT syndrome susceptibility genes was performed. RESULTS The infant had 2 SCN5A mutations: a maternally inherited N-terminal frame shift/deletion (R34fs/60) and a paternally inherited missense mutation, R1195H. The mutations were engineered by site-directed mutagenesis and heterologously expressed transiently in HEK293 cells. As expected, the frame-shifted and prematurely truncated peptide, SCN5A-R34fs/60, showed no current. SCN5A-R1195H had normal peak and late current but abnormal voltage-dependent gating parameters. Surprisingly, co-expression of SCN5A-R34fs/60 with SCN5A-R1195H elicited a significant increase in late sodium current, whereas co-expression of SCN5A-WT with SCN5A-R34fs/60 did not. CONCLUSIONS A severe clinical phenotype characterized by fever-induced monomorphic ventricular tachycardia and QT interval prolongation emerged in a toddler with compound heterozygosity involving SCN5A: R34fs/60, and R1195H. Unexpectedly, the 94-amino-acid fusion peptide derived from the R34fs/60 mutation accentuated the late sodium current of R1195H-containing Na(V)1.5 channels in vitro.
Resumo:
Data on short and long term efficacy and safety of d,l sotalol in patients with atrial fibrillation or atrial flutter is limited. The aims of this study were to (1) assess the antiarrhythmic efficacy of d,l sotalol maintaining normal sinus rhythm in patients with refractory atrial fibrillation or flutter, (2) evaluate the efficacy of d,l sotalol in preventing recurrences of paroxysmal atrial fibrillation or flutter, (3) evaluate the control of ventricular rate in patients with paroxysmal or refractory atrial fibrillation or flutter unsuccessfully treated with other antiarrhythmic agents, (4) determine predictors of efficacy (5) assess the safety of d,l sotalol in this setting. Two hundred patients with chronic or paroxysmal atrial fibrillation or atrial flutter or both, who had failed one to six previous antiarrhythmic drug trials were treated with d,l sotalol 80 to 440 mg/day orally. Fifty four percent was female, age 47 +/- 16 years (range 7-79), follow up period 7 +/- 7 months (range 1 to 14 months), 79% of patients had the arrhythmia for more than one year. The atrial fibrillation in 37.5% of patients was chronic and paroxysmal in 23.5. The atrial flutter was chronic in 31% of patients and paroxysmal in 8%. Eighty two percent of patients was in functional class I (NYHA) and 82% had cardiac heart disease: left atrial (LA) size 44 +/- 10 mm, right atrial (RA) size 37 +/- 7 mm and left ventricular ejection fraction (LVEF) 58 +/- 8%. Total success was achieved in 58% of patients (atrial fibrillation 40% and 18% in atrial flutter), partial success in 38% (atrial fibrillation in 18% and 20% in atrial flutter) and 4% of patients failure. It was p < 0.07 when compared total success vs partial success among atrial fibrillation and atrial flutter groups. Patients with cardiac heart disease responded worst (p = 0.10) to the drug than those without it, specially if the heart was dilated. We concluded that d,l sotalol has moderate efficacy to convert and maintain normal sinus rhythm, as well as it acts controlling paroxysmal relapses and ventricular heart rate.
Resumo:
UNLABELLED The abnormal development of the tricuspid valve in patients with Ebstein's anomaly results in several activation abnormalities including delayed intraatrial conduction, right bundle branch block (RBBB), and ventricular preexcitation. The aim of the present study was to define the ECG characteristics before and after ablation of an accessory A-V pathway (AP) in patients with Ebstein's anomaly. METHODS A series of 226 consecutive patients with Ebstein's anomaly was studied. Sixty-four patients (28%) had documented tachycardia. Thirty-three patients with recurrent tachycardia were found to have a single right-sided AP that was successfully ablated (study group). Thirty patients without tachycardia served as the control group. RESULTS Only 21 of 33 patients (62%) had a typical ECG pattern of preexcitation. In addition, none of the patients had an ECG pattern of RBBB during sinus rhythm. In contrast, 28 of 30 (93%) patients in the control group had RBBB (P < 0.001). Radiofrequency catheter ablation resulted in appearance of RBBB in 31 of 33 (94%) patients. The absence of RBBB in patients with Ebstein's anomaly and recurrent tachycardia had a 98% sensitivity and 92% specificity for the diagnosis of an AP. The positive predictive value was 91% (0.77, 0.97 CI 95%) and the negative predictive value was 98% (0.85, 0.99 CI 95%). CONCLUSION One-third of patients with Ebstein's anomaly and symptomatic tachyarrhythmias have minimal or absent ECG features of ventricular preexcitation. In these patients, the absence of RBBB pattern is a strong predictor of an AP.
Resumo:
Studies analyzing the diagnostic value of 12-lead electrocardiographic criteria differentiating slow-fast atrioventricular nodal reentrant tachycardia (AVNRT) from atrioventricular reentrant tachycardia (AVRT) due to concealed accessory pathway have shown inconsistent results. In 97 patients (50 with AVNRT, 47 with AVRT) 12-lead electrocardiograms (ECGs) were recorded during sinus rhythm and tachycardia (QRS <120 ms). The ECGs were blinded for diagnosis and patient and analyzed independently by 2 electrophysiologists. The studied criteria differentiating AVNRT from AVRT included pseudo-r'/S, the presence of a retrograde P wave, RP interval, ST-segment depression >/=2 mm with the number and location of the affected leads, QRS amplitude, and cycle length alternans.
Resumo:
The electroanatomic mapping system Carto((R)) with its combination of anatomic and electrophysiologic information has substantially improved our understanding of arrhythmia mechanisms and substrates in patients with ventricular tachycardia (VT) and structural heart disease. Identification of the individual arrhythmogenic substrate and successful ablation guided by the combination of sinus rhythm voltage mapping and conventional electrophysiologic techniques like pace and activation/entrainment mapping are best described for patients with recurrent VT in remote myocardial infarction. In about 75-90% of the patients, the target VT can be ablated with acute success and the patients remain free of any VT recurrence in up to 75%. First results of electroanatomically guided ablation in patients with arrhythmogenic right ventricular dysplasia are promising. Data on ablation of VT in other structural heart diseases are very limited, since the arrhythmogenic substrate is very diffuse, e. g., in dilated cardiomyopathy, or there are only small patient numbers, e. g., for cardiac sarcoidosis or monomorphic VT after repair of congenital heart disease. In this article, the current status of electroanatomically guided endocardial mapping and ablation of VT in patients with structural heart disease is described.
Resumo:
BACKGROUND The role of subsequent atrial tachycardias (AT) in the context of persistent atrial fibrillation (AF) remains undetermined. This study evaluated the prognostic role of subsequent ATs for arrhythmia recurrences after catheter ablation of persistent AF. METHODS AND RESULTS A total of 110 patients with persistent AF (63±9 years; 22 women; 61 long-lasting persistent AF) underwent pulmonary vein isolation followed by electrogram-guided ablation. After AF terminated to AT, patients were separated by the randomization protocol to receive either direct cardioversion (group A) or further ablation of subsequent ATs to sinus rhythm (group B). After a mean follow-up of 20.1±13.3 months after the first procedure, significantly more group B patients were in sinus rhythm as compared with patients in group A (30 [57%] versus 18 [34%]; P=0.02). Moreover, recurrences of AF were significantly less frequent of group B than in group A patients (10 [19%] versus 26 [49%]; P=0.001). After the last procedure (follow-up, 34.0±6.4 months), significantly more group B patients were free of AF as compared with patients of group A (49 [92%] versus 39 [74%]; P=0.01). The proportion of AT recurrences did not differ between the 2 groups after the first and final procedures. The strongest predictor for an arrhythmia-free survival after a single procedure was randomization to the procedural end point of termination to sinus rhythm by elimination of subsequent ATs (P=0.004). CONCLUSIONS Catheter ablation of subsequent ATs increases freedom from AF but not AT, suggesting a contributing role of subsequent ATs in the mechanisms of persistent AF. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT01896570.
Resumo:
Catheter ablation for paroxysmal atrial fibrillation is a meanwhile established therapy option, which is most frequently performed using radiofrequency ablation. Mid-term success rate of 70 % are achievable with a single ablation procedure. However, the mechanistics of persistent atrial fibrillation are less well understood and catheter ablation is a far more challenging procedure. Different ablation approaches are being performed to treat persistent atrial fibrillation ranging from sole pulmonary vein isolation to additional ablation of fractionated electrograms aiming for termination of atrial fibrillation. Thus far, it has not been investigated which strategy is most successful in treating persistent atrial fibrillation. After extended ablation of atrial fibrillation, occurrence of organized atrial arrhythmias is not uncommon and can be successfully ablated. These consecutive arrhythmias can be considered as a next step towards stable sinus rhythm after repeat ablation. Improvement of mapping methods as well as a better understanding of mechanisms of atrial fibrillation may increase success rate of catheter ablation of persistent atrial fibrillation and may also help to improve success rate of these complex procedures.
Resumo:
Background Open-irrigated radiofrequency catheter ablation (oiRFA) of atrial fibrillation (AF) imposes a volume load and risk of pulmonary edema. We sought to assess the effect of volume administration during ablation on left atrial (LA) pressure and B-type natriuretic peptide (BNP). Methods LA pressure was measured via transseptal sheath at the beginning and end of 44 LA ablation procedures in 42 patients. BNP plasma levels were measured before and after 10 procedures. Results A median of 3,255 (interquartile range [IQR], 2,014)-mL saline was administered during the procedure. During LA ablation, the median fluid balance was +1,438 (IQR, 1,109) mL and LA pressure increased by median 3.7 (IQR, 5.9) mm Hg (P < 0.001). LA pressure did not change in the 19 procedures with furosemide administration (median ΔP = −0.3 [IQR, 7.1] mm Hg, P = 0.334). The correlation of LA pressure and fluid balance was weak (rs = 0.383, P = 0.021). BNP decreased in all four procedures starting in AF or atrial tachycardia and then converting to sinus rhythm (P = 0.068), and increased in all six procedures starting and finishing in sinus rhythm (P = 0.028). After ablation, symptomatic volume overload responding to diuresis occurred in three patients. Conclusions A substantial intravascular volume load during oiRFA can be absorbed with little change in LA pressure, such that LA pressure is not a reliable indicator of the fluid balance. Subsequent redistribution of the volume load imposes a risk after the procedure. Conversion to sinus rhythm may improve ability to acutely accommodate the volume load.
Resumo:
BACKGROUND -This study aimed to determine five-year efficacy of catheter ablation for persistent atrial fibrillation (PsAF) using AF termination as a procedural endpoint. METHODS AND RESULTS -150 patients (57±10 years) underwent PsAF ablation using a stepwise ablation approach (pulmonary vein isolation, electrogram-guided and linear ablation) with the desired procedural endpoint being AF termination. Repeat ablation was performed for recurrent AF or atrial tachycardia (AT). AF was terminated by ablation in 120 patients (80%). Arrhythmia-free survival rates after a single procedure were 35.3±3.9%, 28.0±3.7%, and 16.8±3.2% at 1, 2, and 5 years, respectively. Arrhythmia-free survival rates after the last procedure (mean 2.1±1.0 procedures) were 89.7±2.5%, 79.8±3.4%, and 62.9±4.5%, at 1, 2, and 5 years, respectively. During a median follow-up of 58 (IQR 43-73) months following the last ablation procedure, 97 of 150 (64.7%) patients remained in sinus rhythm without antiarrhythmic drugs (AADs). Another 14 (9.3%) patients maintained sinus rhythm after re-initiation of AADs, and an additional 15 (10.0%) patients regressed to paroxysmal recurrences only. Failure to terminate AF during the index procedure (HR 3.831; 95%CI: 2.070-7.143; p<0.001), left atrial diameter ≥50mm (HR 2.083; 95%CI: 1.078-4.016; p=0.03), continuous AF duration ≥18 months (HR 1.984; 95%CI: 1.024-3.846; p<0.04) and structural heart disease (HR 1.874; 95% CI: 1.037-3.388; p=0.04) predicted arrhythmia recurrence. CONCLUSIONS -In patients with PsAF, an ablation strategy aiming at AF termination is associated with freedom from arrhythmia recurrence in the majority of patients over a 5-year follow up period.Procedural AF non-termination and specific baseline factors predict long-term outcome after ablation.
Resumo:
BACKGROUND The Sorin Freedom SOLO (FS) bovine pericardial stentless valve prosthesis is designed for supraannular, subcoronary implantation. We report our experience and results with 277 consecutively implanted FS bioprostheses. METHODS 277 patients (mean age, 74.2 ± 7.3 years; 139 (50.2%) female) underwent aortic valve replacement (AVR) with the FS stentless bioprosthesis. The hemodynamic performance was investigated with transthoracic echocardiography at discharge, 6 months later, and yearly thereafter. Follow-up was 100% complete, with an average observation time of 2.6 ± 1.7 years and a total of 697.3 patient-years. RESULTS The overall 30-day mortality was 4.3%. The mortalities for isolated AVR and combined procedures were 1.9% and 7.3%, respectively. No causes of death were valve-related. Preoperative peak (74.2 ± 23.0 mm Hg) and mean (48.6 ± 16.3 mm Hg) gradients decreased to 15.6 ± 5.4 mm Hg and 8.8 ± 3.0 mm Hg postoperatively and remained unchanged for as long as 5 years. The postoperative mean effective orifice area (EOA) for valve sizes 19, 21, 23, 25, and 27 were 1.49 ± 0.32 cm(2), 1.67 ± 0.40 cm(2), 1.92 ± 0.38 cm(2), 2.01 ± 0.42 cm(2), and 2.13 ± 0.36 cm(2), respectively. Severe prosthesis-patient mismach (PPM) was completely absent, and moderate PPM occurred in 17 patients (6.1%). In isolated AVR, 0.8% of patients with preoperative sinus rhythm required a permanent pacemaker before hospital discharge. There was 100% freedom from structural valve deterioration, 99.6 % freedom from endocarditis and reoperation, and 97.3% freedom from thromboembolism at 5 years. CONCLUSIONS The FS stentless aortic valve is safe to implant, and it shows excellent hemodynamic performance and early and midterm results. Owing to the favorable EOA, the valve appears particularly attractive for patients at risk for PPM.
Resumo:
PURPOSE Assessment of experience gained by local referring physicians with the procedure of coronary computed tomographic angiography (CCTA) in the everyday clinical routine. MATERIALS AND METHODS A 25-item questionnaire was sent to 179 physicians, who together had referred a total of 1986 patients for CCTA. They were asked about their experience to date with CCTA, the indications for coronary imaging, and their practice in referring patients for noninvasive CCTA or invasive catheter angiography. RESULTS 53 questionnaires (30 %) were assessable, corresponding to more than 72 % of the patients referred. Of the referring physicians who responded, 94 % saw a concrete advantage of CCTA in the treatment of patients, whereby 87 % were 'satisfied' or 'very satisfied' with the reporting. For excluding coronary heart disease (CHD) where there was a low pre-test probability of disease, the physicians considered CCTA to be superior to conventional coronary diagnosis (4.2 on a scale of 1 - 5) and vice versa for acute coronary syndrome (1.6 of 5). The main reasons for unsuitability of CCTA for CT diagnosis were claustrophobia and the absence of a sinus rhythm. The level of exposure to radiation in CCTA was estimated correctly by only 42 % of the referring physicians. 90 % of the physicians reported that their patients evaluated their coronary CT overall as 'positive' or 'neutral', while 87 % of the physicians whose patients had undergone both procedures reported that the patients had experienced CCTA as the less disagreeable of the two. CONCLUSION CCTA is accepted by the referring physicians as an alternative imaging procedure for the exclusion of CHD and received a predominantly positive assessment from both the referring physicians and the patients.
Resumo:
BACKGROUND Data on pharmacological management during pregnancy are scarce. The aim of this study was to describe the type and frequency of cardiac medication used in pregnancy in patients with cardiovascular disease and to assess the relationship between medication use and fetal outcome. METHODS AND RESULTS Between 2007 and 2011 sixty hospitals in 28 countries enrolled 1321 pregnant women. All patients had structural heart disease (congenital 66%, valvular 25% or cardiomyopathy 7% or ischemic 2%). Medication was used by 424 patients (32%) at some time during pregnancy: 22% used beta-blockers, 8% antiplatelet agents, 7% diuretics, 2.8% ACE inhibitors and 0.5% statins. Compared to those who did not take medication, patients taking medication were older, more likely to be parous, have valvular heart disease and were less often in sinus rhythm. The odds ratio of fetal adverse events in users versus non-users of medication was 2.6 (95% CI 2.0-3.4) and after adjustment for cardiac and obstetric parameter was 2.0 (95% CI 1.4-2.7). Babies of patients treated with beta-blockers had a significantly lower adjusted birth weight (3140 versus 3240 g, p = 0.002). The highest rate of fetal malformation was found in patients taking ACE inhibitors (8%). CONCLUSION One third of pregnant women with heart disease used cardiac medication during their pregnancy, which was associated with an increased rate of adverse fetal events. Birth weight was significantly lower in children of patients taking beta-blockers. A randomized trial is needed to distinguish the effects of the medication from the effects of the underlying maternal cardiac condition.
Resumo:
AIMS Pulmonary vein isolation (PVI) is an effective treatment option for paroxysmal atrial fibrillation (PAF). Reconnection of pulmonary veins (PVs) is the predominant cause for recurrence of PAF. However, treatment of patients with recurrence of PAF despite isolated PV in the absence of extra-PV foci remains challenging. METHODS AND RESULTS Of 265 patients undergoing repeat catheter ablation (CA) for recurrence of PAF 21 (8%) patients (14 men, age 58 ± 14 years) showed no reconnection of PV. Therefore, inducibility of sustained atrial arrhythmias was tested. If sustained atrial fibrillation (AF) or sustained atrial tachycardia (AT) was induced, patients underwent CA. During follow-up (FU), Holter- and Tele-electrocardiogram were performed. In 19 (91%) of 21 patients, sustained atrial arrhythmias [16 (84%) AF; 3 (15%) patients AT] were induced. One patient showed PAF. Eighteen patients underwent CA aiming for termination of induced arrhythmia. In 14 (77%) patients, termination into sinus rhythm was achieved. Despite extensive CA, three (16%) patients were externally cardioverted. No periprocedural complications occurred. During 21.2 ± 6.8-month FU, 10 (53%) patients were free of any arrhythmia. Paroxysmal atrial fibrillation recurred in 4 (21%) and AT in 5 (26%) patients. One patient showed persistent AF. Repeat CA was scheduled and successfully performed for these patients. CONCLUSION In patients with recurrence of PAF despite isolated PV, termination of induced atrial arrhythmias can be achieved in most patients by defragmentation and AT ablation. Moreover, this ablation strategy results in favourable mid-term outcome results.
Resumo:
INTRODUCTION Mitral isthmus (MI) ablation is an effective option in patients undergoing ablation for persistent atrial fibrillation (AF). Achieving bidirectional conduction block across the MI is challenging, and predictors of MI ablation success remain incompletely understood. We sought to determine the impact of anatomical location of the ablation line on the efficacy of MI ablation. METHODS AND RESULTS A total of 40 consecutive patients (87% male; 54 ± 10 years) undergoing stepwise AF ablation were included. MI ablation was performed in sinus rhythm. MI ablation was performed from the left inferior PV to either the posterior (group 1) or the anterolateral (group 2) mitral annulus depending on randomization. The length of the MI line (measured with the 3D mapping system) and the amplitude of the EGMs at 3 positions on the MI were measured in each patient. MI block was achieved in 14/19 (74%) patients in group 1 and 15/21 (71%) patients in group 2 (P = NS). Total MI radiofrequency time (18 ± 7 min vs. 17 ± 8 min; P = NS) was similar between groups. Patients with incomplete MI block had a longer MI length (34 ± 6 mm vs. 24 ± 5 mm; P < 0.001), a higher bipolar voltage along the MI (1.75 ± 0.74 mV vs. 1.05 ± 0.69 mV; P < 0.01), and a longer history of continuous AF (19 ± 17 months vs. 10 ± 10 months; P < 0.05). In multivariate analysis, decreased length of the MI was an independent predictor of successful MI block (OR 1.5; 95% CI 1.1-2.1; P < 0.05). CONCLUSIONS Increased length but not anatomical location of the MI predicts failure to achieve bidirectional MI block during ablation of persistent AF.
Resumo:
In this paper, a new method is presented to ensure automatic synchronization of intracardiac ECG data, yielding a three-stage algorithm. We first compute a robust estimate of the derivative of the data to remove low-frequency perturbations. Then we provide a grouped-sparse representation of the data, by means of the Group LASSO, to ensure that all the electrical spikes are simultaneously detected. Finally, a post-processing step, based on a variance analysis, is performed to discard false alarms. Preliminary results on real data for sinus rhythm and atrial fibrillation show the potential of this approach.