979 resultados para sample mean


Relevância:

40.00% 40.00%

Publicador:

Resumo:

This thesis proposes some confidence intervals for the mean of a positively skewed distribution. The following confidence intervals are considered: Student-t, Johnson-t, median-t, mad-t, bootstrap-t, BCA, T1 , T3 and six new confidence intervals, the median bootstrap-t, mad bootstrap-t, median T1, mad T1 , median T3 and the mad T3. A simulation study has been conducted and average widths, coefficient of variation of widths, and coverage probabilities were recorded and compared across confidence intervals. To compare confidence intervals, the width and coverage probabilities were compared so that smaller widths indicated a better confidence interval when coverage probabilities were the same. Results showed that the median T1 and median T3 outperformed other confidence intervals in terms of coverage probability and the mad bootstrap-t, mad-t, and mad T3 outperformed others in terms of width. Some real life data are considered to illustrate the findings of the thesis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Current data indicate that the size of high-density lipoprotein (HDL) may be considered an important marker for cardiovascular disease risk. We established reference values of mean HDL size and volume in an asymptomatic representative Brazilian population sample (n=590) and their associations with metabolic parameters by gender. Size and volume were determined in HDL isolated from plasma by polyethyleneglycol precipitation of apoB-containing lipoproteins and measured using the dynamic light scattering (DLS) technique. Although the gender and age distributions agreed with other studies, the mean HDL size reference value was slightly lower than in some other populations. Both HDL size and volume were influenced by gender and varied according to age. HDL size was associated with age and HDL-C (total population); non- white ethnicity and CETP inversely (females); HDL-C and PLTP mass (males). On the other hand, HDL volume was determined only by HDL-C (total population and in both genders) and by PLTP mass (males). The reference values for mean HDL size and volume using the DLS technique were established in an asymptomatic and representative Brazilian population sample, as well as their related metabolic factors. HDL-C was a major determinant of HDL size and volume, which were differently modulated in females and in males.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives. To investigate the test-retest stability of a standardized version of Nelson's (1976) Modified Card Sorting Test (MCST) and its relationships with demographic variables in a sample of healthy older adults. Design. A standard card order and administration were devised for the MCST and administered to participants at an initial assessment, and again at a second session conducted a minimum of six months later in order to examine its test-retest stability. Participants were also administered the WAIS-R at initial assessment in order to provide a measure of psychometric intelligence. Methods. Thirty-six (24 female, 12 male) healthy older adults aged 52 to 77 years with mean education 12.42 years (SD = 3.53) completed the MCST on two occasions approximately 7.5 months (SD = 1.61) apart. Stability coefficients and test-retest differences were calculated for the range of scores. The effect of gender on MCST performance was examined. Correlations between MCST scores and age, education and WAIS-R IQs were also determined. Results. Stability coefficients ranged from .26 for the percent perseverative errors measure to .49 for the failure to maintain set measure. Several measures were significantly correlated with age, education and WAIS-R IQs, although no effect of gender on MCST performance was found. Conclusions. None of the stability coefficients reached the level required for clinical decision making. The results indicate that participants' age, education, and intelligence need to be considered when interpreting MCST performance. Normative studies of MCST performance as well as further studies with patients with executive dysfunction are needed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Multiple sampling is widely used in vadose zone percolation experiments to investigate the extent in which soil structure heterogeneities influence the spatial and temporal distributions of water and solutes. In this note, a simple, robust, mathematical model, based on the beta-statistical distribution, is proposed as a method of quantifying the magnitude of heterogeneity in such experiments. The model relies on fitting two parameters, alpha and zeta to the cumulative elution curves generated in multiple-sample percolation experiments. The model does not require knowledge of the soil structure. A homogeneous or uniform distribution of a solute and/or soil-water is indicated by alpha = zeta = 1, Using these parameters, a heterogeneity index (HI) is defined as root 3 times the ratio of the standard deviation and mean. Uniform or homogeneous flow of water or solutes is indicated by HI = 1 and heterogeneity is indicated by HI > 1. A large value for this index may indicate preferential flow. The heterogeneity index relies only on knowledge of the elution curves generated from multiple sample percolation experiments and is, therefore, easily calculated. The index may also be used to describe and compare the differences in solute and soil-water percolation from different experiments. The use of this index is discussed for several different leaching experiments. (C) 1999 Elsevier Science B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Fornax Spectroscopic Survey will use the Two degree Field spectrograph (2dF) of the Angle-Australian Telescope to obtain spectra for a complete sample of all 14000 objects with 16.5 less than or equal to b(j) less than or equal to 19.7 in a 12 square degree area centred on the Fornax Cluster. The aims of this project include the study of dwarf galaxies in the cluster (both known low surface brightness objects and putative normal surface brightness dwarfs) and a comparison sample of background field galaxies. We will also measure quasars and other active galaxies, any previously unrecognised compact galaxies and a large sample of Galactic stars. By selecting all objects-both stars and galaxies-independent of morphology, we cover a much larger range of surface brightness and scale size than previous surveys. In this paper we first describe the design of the survey. Our targets are selected from UK Schmidt Telescope sky survey plates digitised by the Automated Plate Measuring (APM) facility. We then describe the photometric and astrometric calibration of these data and show that the APM astrometry is accurate enough for use with the 2dF. We also describe a general approach to object identification using cross-correlations which allows us to identify and classify both stellar and galaxy spectra. We present results from the first 2dF field. Redshift distributions and velocity structures are shown for all observed objects in the direction of Fornax, including Galactic stars? galaxies in and around the Fornax Cluster, and for the background galaxy population. The velocity data for the stars show the contributions from the different Galactic components, plus a small tail to high velocities. We find no galaxies in the foreground to the cluster in our 2dF field. The Fornax Cluster is clearly defined kinematically. The mean velocity from the 26 cluster members having reliable redshifts is 1560 +/- 80 km s(-1). They show a velocity dispersion of 380 +/- 50 km s(-1). Large-scale structure can be traced behind the cluster to a redshift beyond z = 0.3. Background compact galaxies and low surface brightness galaxies are found to follow the general galaxy distribution.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aims: To estimate dementia prevalence and describe the etiology of dementia in a community sample from the city of Sao Paulo, Brazil. Methods: A sample of subjects older than 60 years was screened for dementia in the first phase. During the second phase, the diagnostic workup included a structured interview, physical and neurological examination, laboratory exams, a brain scan, and DSM-IV criteria diagnosis. Results: Mean age was 71.5 years (n = 1,563) and 58.3% had up to 4 years of schooling (68.7% female). Dementia was diagnosed in 107 subjects with an observed prevalence of 6.8%. The estimate of dementia prevalence was 12.9%, considering design effect, nonresponse during the community phase, and positive and negative predictive values. Alzheimer`s disease was the most frequent cause of dementia (59.8%), followed by vascular dementia (15.9%). Older age and illiteracy were significantly associated with dementia. Conclusions: The estimate of dementia prevalence was higher than previously reported in Brazil, with Alzheimer`s disease and vascular dementia being the most frequent causes of dementia. Dementia prevalence in Brazil and in other Latin American countries should be addressed by additional studies to confirm these higher dementia rates which might have a sizable impact on countries` health services. Copyright (C) 2008 S. Karger AG, Basel

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background The CAMCOG is a brief neuropsychological battery designed to assess global cognitive function and ascertain the impairments that are required for the diagnosis of dementia. To date, the cut-off scores for mild cognitive impairment (MCI) have not been determined. Given the need for an earlier diagnosis of mild dementia, new cut-off values are also necessary, taking into account cultural and educational effects. Methods One hundred and fifty-seven older adults (mean age: 69.6 +/- 7.4 years) with 8 or more years of formal education (mean years of schooling 14.2 +/- 3.8) attending a memory clinic at the Institute of Psychiatry University of Sao Paulo were included. Subjects were divided into three groups according to their cognitive status, established through clinical and neuropsychological assessment: normal controls, n = 62; MCI, n = 65; and mild or moderate dementia, n = 30. ROC curve analyses were performed for dementia vs controls, MCI vs controls and MCI vs dementia. Results The cut-off values were: 92/93 for dementia is controls (AUC = 0.99: sensitivity: 100%, specificity: 95%); 95/96 for MCI vs controls (AUC = 0.83, sensitivity: 64%, specificity: 88%), and 85/86 for MCI vs dementia (AUC = 0.91, sensitivity: 81%, specificity: 88%). The total CAMCOG score was more accurate than its subtests Mini-mental State Examination, Verbal Fluency Test and Clock Drawing Test when used separately. Conclusions The CAMCOG discriminated controls and MCI from demented patients, but was less accurate to discriminate MCI from controls. The best cut-off value to differentiate controls and demented was higher than suggested in the original publication, probably because only cases of mild to moderate dementia were included. This is important given the need for a diagnostic at earlier stages of Alzheimer`s disease. Copyright (C) 2008 John Wiley & Sons, Ltd.