952 resultados para rotating pressure vessel oxidation test (RPVOT)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Doped lanthanum chromite ( LaCrO3 ) has been the most common material used as interconnect in solid oxide fuel cells for high temperature ( SOFC-HT ) that enabling the stack of SOFCs. The reduction of the operating temperature, to around 800 º C, of solid oxide fuel cells enabled the use of metallic interconnects as an alternative to ceramic LaCrO3, From the practical point of view, to be a strong candidate for interconnect the material must have good physical and mechanical properties such as resistance to oxidizing and reducing environments, easy manufacture and appropriate thermo-mechanical properties. Thus, a study on the physic-mechanical interconnects La0,8Sr0,2Cr0,92Co0,08O3 ceramics for SOFC -AT obtained by the method of combustion , as well as thermo-mechanical properties of metallic interconnects (AISI 444) covered with La0,8Ca0,2CrO3 by deposition technique by spray-pyrolysis fuel cells for intermediate temperature (IT-SOFCs). The La0,8Sr0,2Cr0,92Co0,08O3 was characterized by X -ray diffraction(XRD) , density and porosity , Vickers hardness (HV) , the flexural strength at room temperature and 900 °C and scanning electron microscopy (SEM). The X -ray diffraction confirmed the phase formation and LaCrO3 and CoCr2O4, in order 6 GPa hardness and mechanical strength at room temperature was 62 MPa ceramic Interconnector. The coated metal interconnects La0,8Ca0,2CrO3 passed the identification by XRD after deposition of the film after the oxidation test. The oxidative behavior showed increased resistance to oxidation of the metal substrate covered by La0,8Ca0,2CrO3 In flexural strength of the coated metal substrate, it was noticed only in the increased room temperature. The a SEM analysis proved the formation of Cr2O3 and (Cr,Mn)3O4 layers on metal substrate and confirmed the stability of the ceramic La0,8 Ca0,2CrO3 film after oxidative test

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO: avaliar a concordância dos diferentes parâmetros urodinâmicos comparados à cistometria simplificada, permitindo uma diminuição na relação custo-benefício no diagnóstico da incontinência urinária de esforço (IUE) na mulher. MÉTODOS: foram coletadas e avaliadas retrospectivamente as informações contidas dos prontuários de trinta pacientes acompanhadas, no período de janeiro de 2000 a março de 2001. Todas foram submetidas a exame físico geral e ginecológico. O estudo urodinâmico foi realizado pela técnica convencional, utilizando-se aparelho Dynograph Recorder R-611. A cistometria simplificada foi realizada com auxílio de um equipo em Y de PVC (pressão venosa central), conectado a um sonda de Foley 14 F, que permitia tanto a infusão de soro fisiológico como a captação da pressão intra-vesical. Foram analisados os parâmetros: volume residual, capacidade vesical, complacência, presença de contrações involuntárias do detrusor e perdas urinárias aos esforços. Para determinação da proporção de concordância entre os métodos foram utilizados o teste de concordância de Pearson e o teste de Wilcoxon, para amostras relacionadas. RESULTADOS: a média de idade foi de 50 anos, com extremos variando de 28 a 70 anos. O índice de concordância entre os estudos, na demonstração das perdas urinárias aos esforços, foi de 67%. Para a detecção das contrações involuntárias do detrusor, a proporção de concordância foi de 90%. A média do volume residual encontrado na cistometria simplificada foi de 16,8 ml contra 2 ml da urodinâmica convencional, com diferença significativa (p < 0,01). A média de capacidade vesical máxima no estudo urodinâmico foi de 440,5 ml, enquanto que, na cistometria simplificada, foi de 387 ml (p < 0,05). A complacência vesical foi, em média, significativamente maior na cistometria simplificada (43,0 ml/cmH2O) quando comparada ao estudo urodinâmico (31,5 ml/cmH2O), com p < 0,01. CONCLUSÃO: Avaliações preliminares sugerem que a propedêutica uroginecológica associada à cistometria simplificada é uma opção a ser considerada na avaliação clínica e pré-operatória de pacientes com IUE em substituição à urodinâmica convencional, particularmente onde esta última não se encontra disponível. A cistometria simplificada é um exame acessível que é capaz de detectar contrações involuntárias do detrusor, assim como identificar perdas urinárias com relativa sensibilidade, proporcionando ao examinador noções fidedignas do comportamento vesical.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Odontologia Restauradora - ICT

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Being the corrosion one of the great problems facing the industry today, specifically the internal corrosion of pipes in chemical and petrochemical industries, hence this work proposes a new type of internal coating in order to avoid fouling and decrease the pressure loss in the flow. For this, we use a composition of vinyl ester resins and manometric loads, which after cleaning and preparation of the internal surface of the tube will be applied through a process of centrifugation, adjusted by a lathe. After curing the resin, a test of roughness will be realized in order to analyze the reduction of friction factor and thus be able to conclude whether there was a significant decrease in pressure drop. With test results in hand, we hope to obtain a coating that meets most of the properties required by the industry and to provide a reduction in operating costs and a visible improvement in the conditions of use of the pipe

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work is to analyze the behavior of context concentrated stresses generated around a nozzle connected to a pressure vessel. For this analysis we used the finite element method via a computer interface, the software ANSYS WORKBENCH. It was first necessary to study and intensive training of the software used, and also a study of the ASME Code, Section VIII, which is responsible for the standards used in pressure vessels. We analyzed three cases, which differ primarily in the variation of the diameter of the nozzle in order to analyze the variation of the stresses according to the variation of the diameters. The nozzle diameters were 35, 75 and 105 mm. After the model designed vessel, a pressure was applied on the innervessel of 0.5 MPa. For the smallest diameter, was found the lowest tensions concentrated. Varying between 1 and 223 MPa. Increasing the diameter of the nozzle resulted in increased tensions concentrated around the junction nozzle /vessel. The maximum stresses increased by 78% when the value was increased in diameter from 35 to 75 mm. Since the increase in diameter from 75 to 105 mm, the values of the tensions increased around 43%. These figures emphasize that stress concentrations increased with increasing the diameter of the nozzles, but not linearly

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work it was made analysis of a simple pressure vessel, using the analytical development studied in Mechanics of Materials disciplines, and then using the standard required by ASME. Following the simulation was realized using Autodesk Mechanical Simulation software to calculate the principal stresses in a pressure vessel. The simulation was done in a single vessel without nozzles, compared with the analytic calculation. After that, the simulation of another fictitious pressure vessel was done by adding three nozzles to verify the influence of the nozzles in the principal stresses and compared with the analytical results. After the simulation, it was found that the principal are bigger in the pressure vessel with nozzles, but they decrease at a small distance from the nozzle becoming equal to the stresses in the vessel without nozzles. The analytical results calculated according to the ASME agree with simulated results

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pressure vessels are equipments that require a great care because of their high cost and human life risk in case of fail, and its fabrication methods are different for each manufacturer. Normally, pressure vessels and its parts are fabricated by welding, which may change local properties of metals. The head of a pressure vessel is a very important structural component and it is fabricated by welding and mechanical conformation. Because its excellent mechanical properties, de steel A-516 Grade 70 is often used in manufacturing of large pressure vessels that are subjected to high pressure and temperature, but was verified that its mechanical resistance is decreased when submitted to a tension relief heat treatment. By experience it was defined that before mechanical conformation of the head of a large pressure vessel, the steel should be submitted to a stress relief heat treatment in order to facilitate the mechanical conformation, but there is no quantitative analysis to prove this method and study its possible risks. In the present work the steel A-516 Grade 70 demonstrated a decrease of its mechanical resistance when submitted to a stress relief heat treatment, but keeping above the minimum limit defined in the literature. By other side its ductility was substantially increased, being possible to deduce that the stress relief heat treatment before mechanical conformation is a viable e recommended technique, but with reservations. With the data acquired during the fabrication e preparation of the specimen and the result of the tests, it was possible to elaborate a welding procedure that provides the same results obtained in this present work

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the impact of different disinfection solutions on flexural resistance of chemically-activated acrylic resin. Test pieces were made of clear acrylic resin using a rectangular mold and employing two techniques: wet polymerization under pressure (n = 20) and dry polymerization under pressure (n = 20). Test pieces were subdivided into four equal groups: distilled water (control), sodium bicarbonate, 1% sodium hypochlorite and effervescent ats. The 30-day cycling technique consisted of immersing the test pieces in 100 ml of solution for 10 min three times a day and placing them in closed containers containing artificial saliva at 37°C. Subsequently, the flexural resistance of samples was tested. Data were analyzed using two-way analysis of variance (ANOVA) with forces serving as the dependent variables and the polymerization technique and cleaning agents as independent variables. Post hoc multiple comparisons were performed using Tukey’s test. There was no statistically significant difference in the flexural strength between the two polymerization techniques. The greatest flexural strength was observed for the effervescent tablets group followed by the control and 1% sodium hypochlorite groups which were statistically similar. Thus, the sodium bicarbonate solution caused the lowest flexural resistance of the test pieces.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In a market environment increasingly competitive, the companies need to control of this process accurately, avoiding rework or rejection of materials during industrialization. This can be achieved by defining procedure that assure the maintenance of the materials characteristics, as specified initially in the projects. This graduation work has the objective of defining the best heat treatment parameter of normalizing for Heads, part of a pressure vessel, formed in P275NH material. The methodology applied is based on the execution of a sequence of Heat Treatments, using different parameters. The process variables were the cooling velocity, the hold time and the hold temperature variation. As a result of this study, it is noticed that the mechanical properties of the materials are strongly influenced by the hold temperature variation and by the cooling velocity, both determined for the heat treatment cycle

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The manufacturing process of components of Pressure Vessels has a great importance in the efficiency during the operation and life cycle of the equipment. Taking this into account, the objective of this dissertation was to analyze the methods to determine the strain rate in formed components by measuring the components themselves, and posterior results comparison with the values found in manufacturing standards of Pressure vessels. In this study the whole manufacturing process of a component from a pressure vessel, known as Head or End, was accompanied. Using the methodology obtained from literatures it was possible to execute the relative and logarithmic deformation measurements of these components and compare with the obtained results by means of equations presented in the Standards as AD-Merkblatt and ASME (for pressure vessels). The found results were also compared with the logarithmic methodology, taking into account the deformation of the empirical mesh and the thickness of the components studied. It is possible to conclude from this study that despite the existence of empirical methods of measurement of strain rate in components plastically formed, it is recommended the adoption in all situation of the component manufacturing standard. It can be noticed and explained during the development of this study and through the results found

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In a market environment increasingly competitive, the companies need to control of this process accurately, avoiding rework or rejection of materials during industrialization. This can be achieved by defining procedure that assure the maintenance of the materials characteristics, as specified initially in the projects. This graduation work has the objective of defining the best heat treatment parameter of normalizing for Heads, part of a pressure vessel, formed in P275NH material. The methodology applied is based on the execution of a sequence of Heat Treatments, using different parameters. The process variables were the cooling velocity, the hold time and the hold temperature variation. As a result of this study, it is noticed that the mechanical properties of the materials are strongly influenced by the hold temperature variation and by the cooling velocity, both determined for the heat treatment cycle

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The manufacturing process of components of Pressure Vessels has a great importance in the efficiency during the operation and life cycle of the equipment. Taking this into account, the objective of this dissertation was to analyze the methods to determine the strain rate in formed components by measuring the components themselves, and posterior results comparison with the values found in manufacturing standards of Pressure vessels. In this study the whole manufacturing process of a component from a pressure vessel, known as Head or End, was accompanied. Using the methodology obtained from literatures it was possible to execute the relative and logarithmic deformation measurements of these components and compare with the obtained results by means of equations presented in the Standards as AD-Merkblatt and ASME (for pressure vessels). The found results were also compared with the logarithmic methodology, taking into account the deformation of the empirical mesh and the thickness of the components studied. It is possible to conclude from this study that despite the existence of empirical methods of measurement of strain rate in components plastically formed, it is recommended the adoption in all situation of the component manufacturing standard. It can be noticed and explained during the development of this study and through the results found

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The 24th Biochemical Engineering Symposium was held 9-10 September 1994 at the YMCA of the Rockies conference center in Estes Park, Colorado, under the sponsorship of the Department of Chemical Engineering at the University of Colorado. Previous symposia in this series have been hosted by Kansas State University (1st, 3rd, 5th, 9th, 12th, 16th, 20th), University of Nebraska-Lincoln (2nd, 4th), Iowa State University (6th, 7th, 10th, 13th, 17th, 22nd), University of Missouri-Columbia (8th, 14th, 19th), Colorado State University (11th, 15th, 21st), University of Colorado (18th), and the University of Oklahoma (23rd). The next symposium is scheduled to be held at the University of Missouri-Columbia. The symposia are devoted to talks by students about their ongoing research. Because final publication usually takes place elsewhere, the papers included in the proceedings are brief, and often cover work in progress. ContentsIn-Well Aeration: An Innovative Subsurface Remediation TechnologyPrashant Gandhi, X. Yang, L.E. Erickson, and L. T. Fan; Kansas State University Expression of an Antimicrobial Peptide Analog in Eacherlchill coliChris Haught and Roger G. Harrison; University of Oklahoma Using High-frequency Backpulaing to Maximize Croasflow Filtration PerformanceSanjeev G. Redkar and Robert H. Davis; University of Colorado Low Molecular Weight Organic Compositions of Acid Waters from Vegetable Oil SoapstocksSteven L. Johansen, Arunthathi Sivasothy, Peter J. Reilly, and Earl G. Hammond; Iowa State University; Michael K. Dowd; U.S. Department of Agriculture Gas Phase Composition Effects on Suspension Cultures of Taxus cuspidata Noushin Mirjalili and James C. Linden; Colorado State University Cybernetic Modeling of Spontaneous Oscillations in Continuous Cultures of Ssccharomyces cerevisiaeKenneth D. Jones and Dhinakar S. Kompala; University of Colorado The Effect of Turbulent Shear on Calcium Mobilization in Mammalian CellsChristopher M. Cannizzaro, Pradyumna K. Namdev, and Eric H. Dunlop; Colorado State University Experimental Studies of Droplet Ejection at the Free Surface In Sparged ReactorsT. Y. Yiin, L A. Glasgow, and L. E. Erickson; Kansas State University The Role of Domain E (Starch-Binding Region) on the Activity of a Bacillus macersns Cyclodextrln GlucanotransferaseHai-yin Chang, Trang Le, and Zivko L. Nikolov; Iowa State University Use of the Rotating Wall Vessel for Study of Plant Cell Suspension CulturesXinzhi Sun and James C. Linden; Colorado State University A Novel Counter-Current Distribution Apparatus for the Study of Multi-Stage Aqueous Two-Phase Extraction of Biomolecules and Cell ParticlesMartin R. Guinn and Paul Todd; University of Colorado The Dynamics of Unhooking and Contraction of a Polyelectrolyte Chain Around an Isolated PostLin Zhang and Edith M. Sevick; University of Colorado A Laboratory Study of the Fate of Trichloroathylene and 1,1,1-Trlchloroathane In the Presence of Alfalfa PlantsMuralidharan Narayanan, Ryan M. Green, Lawrence C. Davis, and Larry E. Erickson; Kansas State University Modeling the Fate of Pyrene In the RhIzosphereS.K. Santharam, LE. Erickson, and L. T. Fan; Kansas State University Derivatization of MaltooligosaccharidesDaniela Prinz, Peter J. Reilly, and Zivko L. Nikolov; Iowa State University Probing Surfactant-Protein Binding by EPA SpectroscopyNarendra B. Bam, Yale University; Theodore W. Randolph; University of Colorado Optimization of a Stir-Cell Bioreactor for In Vitro Production of RNANeal T. Williams, Kim A. Wicklund, and Robert H. Davis; University of Colorado

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We performed hydrous partial melting experiments at shallow pressures (0.2 GPa) under slightly oxidizing conditions (NNO oxygen buffer) on oceanic cumulate gabbros drilled by ODP (Ocean Drilling Program) cruises to evaluate whether the partial melting of oceanic gabbro can generate SiO2-rich melts with compositions typical of oceanic plagiogranites. The experimental melts of the low-temperature runs broadly overlap those of natural plagiogranites. At 940 °C, the normalized SiO2 contents of the experimental melts of all systems range between 60 and 61 wt%, and at 900 °C between 63 and 68 wt%. These liquids are characterized by low TiO2 and FeOtot contents, similar to those of natural plagiogranites from the plutonic section of the oceanic crust, but in contrast to Fe and Ti-rich low-temperature experimental melts obtained in MORB systems at ~950 °C. The ~1,500-m-long drilled gabbroic section of ODP Hole 735B (Legs 118 and 176) at the Southwest Indian Ridge contains numerous small plagiogranitic veins often associated with zones which are characterized by high-temperature shearing. The compositions of the experimental melts obtained at low temperatures match those of the natural plagiogranitic veins, while the compositions of the crystals of low-temperature runs correspond to those of minerals from high-temperature microscopic veins occurring in the gabbroic section of the Hole 735B. This suggests that the observed plagiogranitic veins are products of a partial melting process triggered by a water-rich fluid phase. If the temperature estimations for hightemperature shear zones are correct (up to 1,000 °C), and a water-rich fluid phase is present, the formation of plagiogranites by partial melting of gabbros is probably a widespread phenomenon in the genesis of the ocean crust.