840 resultados para rotary tiller
Resumo:
The first Rotary Club was created in February 1905, by Chicago lawyer Paul P. Harris. Harris envisioned a club which would bring members of the business community closer together. As his vision grew more members were acquired. In order to accommodate everyone, meetings were held at each of the member’s place of business; hence the name Rotary Club was adopted. A wagon wheel was chosen as an appropriate symbol to denote the club; which today has become the cogwheel. By the close of its first year the club had thirty members. Slowly Rotary Clubs began emerging across the country and by 1910 they had become International by moving North to Canada. By 1921 Rotary representation was present in every Continent and in 1922 the name Rotary International had been approved. The Rotary Club of St. Catharines came into existence on May 19, 1921 under the Charter President Canon Bill Broughall. The Club’s beginnings were humble with only twenty-five members; however, by their seventy-fifth anniversary the club had grown to one hundred and forty-four. The Rotary Club of St. Catharines is a non-profit charity, prescribing to the motto Service above Self. This motto is demonstrated through the Clubs numerous contributions to society both locally and internationally. The Club raises funds, supports exchange programs, and participates in community service work. Some of the organizations which have benefited from the Clubs donations; include, Easter Seals, the Niagara Peninsula Children’s Centre, and the Youth Exchange Program.
Resumo:
The rotary valve is a widely used mechanical device in many solids-handling industrial processes. However, it may also be responsible for most of the attrition effects occurring in a typical process. In this study, the attrition effects occurring in a rotary valve operating as a stand-alone device and as part of a pneumatic conveying system were investigated. In the former case granular attrition was carried out at three different rotary valve speeds and the experimental results obtained were found to be in good agreement with the Gwyn correlation. In the latter case three typical air flow rates were used in the pneumatic conveying system. The size distribution of the attrition product obtained at the lowest air flow rate used was not adequately described by the Gwyn correlation. The attrition process and mechanisms involved were analysed and the minimum size of the attrition product obtained from both modes of operations was found to be similar.
Resumo:
This paper discusses the rationale, clinical applications, advantages and disadvantages of three common balance function tests: Electronystagmography (ENG), Rotational Chair Testing (RCT), and Computerized Dynamic Posturography (CDP).
Resumo:
This paper develops fuzzy methods for control of the rotary inverted pendulum, an underactuated mechanical system. Two control laws are presented, one for swing up and another for the stabilization. The pendulum is swung up from the vertical down stable position to the upward unstable position in a controlled trajectory. The rules for the swing up are heuristically written such that each swing results in greater energy build up. The stabilization is achieved by mapping a stabilizing LQR control law to two fuzzy inference engines, which reduces the computational load compared with using a single fuzzy inference engine. The robustness of the balancing control is tested by attaching a bottle of water at the tip of the pendulum.
Resumo:
Introduction: The aim of the present study was to determine the disinfection of preparations carried out by using the Protaper or MTwo system in canals infected with Enterococcus faecalis. Methods: Twenty-eight distobuccal canals of upper molars were used, in which the canals were sterilized after being enlarged to #20 file and then contaminated with an inoculation of a culture of E. faecalis. After the incubation period, bacterial samples were collected and were seeded on plates for analysis of colony-forming units (CFU)/mL. The teeth were divided into 2 groups according to the rotary system used for instrumentation; 2 noninstrumented teeth served as the control group. Then bacterial samples were collected and were seeded on plates for analysis of CFU/mL again. The data obtained were evaluated by the Wilcoxon and Mann-Whitney U tests. Results: Bacterial reduction was 81.94% and 84.29%, respectively, in Pro Taper and Mtwo systems, and there was no statistically significant difference (P > .05). Conclusions: Both systems, Pro Taper and Mtwo, reduced the amount of bacteria in the mechanical disinfection of the root canal system, demonstrating that they are suitable for this purpose. (J Endod 2010;36:1238-1240)
Resumo:
Hålningsprocessen är det inledande bearbetningssteget vid varmvalsning av sömlösa rör. Det är en tvärvalsningsprocess i vilken ett cylindriskt ämne valsas mellan två dubbelkoniska val¬sar över en plugg. Valsarna är snedställda med en viss mat¬ningsvinkel, vilken ger upphov till en axiell drivkraft genom ver¬ket. Hela denna pro¬cess är roterande. Detta i kombination med bl.a. de koniska valsarna leder till en förvrid¬ning av röret, dvs. en tänkt rak linje på det ingå¬ende äm¬net övergår till en spiral efter genomförd valsning. Med föreliggande uppgift är målet att studera förvridningen genom teoretisk och experimen¬tell analys. Syftet med detta är dels att få fördjupad kunskap inom området och dels att ut¬veckla en modell för pre¬diktering av förvridningen.Det experimentella arbetet är utfört på ett stål av typ Ovako 280 (SS2142). Denna mjuka stål¬sort valdes i syfte att undvika värmebehandling innan provberedning. För att visuali¬sera för¬vridningen fräs¬tes ett rakt spår längs det ingående äm¬net och hål borrades mot symmetrilinjen. De praktiska undersökningarna utfördes direkt i den löpande produktionen. Genomförda beräkningar uppvisar en längsgående förvridningsvinkel som stämmer väl över¬ens med uppmätt värde. Detta är dock under antagandet att den tangentiella hastighetskoeffi¬cienten varierar linjärt utmed deformationszonen. För en mer utvecklad modell krävs en nog¬grannare analys av kontakten mellan vals/ämne eller en grundligt genomförd uppmätning av ämnets vinkelhastighet.
Resumo:
This study examined a new conservation tillage tool, the rotary paraplow. Emphasis was placed on evaluating the tool's conservation potential using dimensionless graph analysis. The dynamic conditions of the soil were investigated in terms of physical soil properties. Having determined the variables to be measured, dimensional analysis was used to plan the experiments. Two variations were considered for each dependent variable (linear speed, working depth, and rotation velocity), totaling eight treatments, allotting in each an experimental strip with five data collection points. This arrangement totaled 16 experimental strips, with 80 data collection points for all variables. The rotary paraplow generates a trapezoidal furrow for planting with a very wide bottom and narrower at the top. The volumetric subsoiling action generates cracks on the sides of the band. Because of their specific geometry the blades of rotary paraplow generate a soil failure according to its natural crack angle, optimizing the energy use, while preserving the natural soil properties. Results showed the conservation character of the rotary paraplow, capable of breaking up clods for planting without changing the original physical soil properties.
Resumo:
The aim of this study was to evaluate the efficacy of three rotary instrument systems (K3, ProTaper and Twisted File) in removing calcium hydroxide residues from root canal walls. Thirty-four human mandibular incisors were instrumented with the ProTaper System up to the F2 instrument, irrigated with 2.5% NaOCl followed by 17% EDTA, and filled with a calcium hydroxide intracanal dressing. After 7 days, the calcium hydroxide dressing was removed using the following rotary instruments: G1 - NiTi size 25, 0.06 taper, of the K3 System; G2 - NiTi F2, of the ProTaper System; or G3 - NiTi size 25, 0.06 taper, of the Twisted File System. The teeth were longitudinally grooved on the buccal and lingual root surfaces, split along their long axis, and their apical and cervical canal thirds were evaluated by SEM (×1000). The images were scored and the data were statistically analyzed using the Kruskall Wallis test. None of the instruments removed the calcium hydroxide dressing completely, either in the apical or cervical thirds, and no significant differences were observed among the rotary instruments tested (p > 0.05).
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The purpose of this study was to compare the incidence of dentinal defects (fractures and craze lines) after canal preparation with different nickel-titanium rotary files. Two hundred sixty mandibular premolars were selected. Forty teeth were left unprepared (n = 40). The other teeth were prepared either with manual Flexofiles (n = 20) or with different rotary files systems: ProTaper (Dentsply-Maillefer, Ballaigues, Switzerland), ProFile (Dentsply-Maillefer), SystemGT (Dentsply-Maillefer), or S-ApeX (FKG Dentaire, La Chaux-de-Fonds, Switzerland) (n = 50 each). Roots were then sectioned 3, 6, and 9 mm from the apex and observed under a microscope. The presence of dentinal defects was noted. There was a significant difference in the appearance of defects between the groups (p < 0.05). No defects were found in the unprepared roots and those prepared with hand files and S-ApeX. ProTaper, ProFile, and GT preparations resulted in dentinal defects in 16%, 8%, and 4% of teeth, respectively. Some endodontic preparation methods might damage the root and induce dentinal defects. (J Endod 2009;35:236-238)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective. To evaluate the healing of experimentally induced chronic periapical lesions in dogs at 30, 75, and 120 days after root canal instrumentation with rotary NiTi files or manual K-files, with or without a calcium hydroxide/1% chlorhexidine paste intracanal dressing.Study design. The second, third, and fourth mandibular premolars and the second and third maxillary premolars of 5 dogs (12 to 18 months of age, weighing 8 to 15 kg) were selected for treatment (a total of 82 root canals). After pulp removal, the root canals were left exposed to the oral cavity for 7 days to allow microbial contamination, after which the root canals were sealed with ZOE cement until periapical lesions were confirmed with radiography. Group I and II teeth were instrumented with manual K-files using the crown-down technique. In group III and IV teeth, NiTi rotary files were used. The apical delta was perforated by using #20 to #30 K-files at the length of the tooth, thus creating a standardized apical opening. The apical stop was enlarged to size 70, with 2.5% sodium hypochlorite irrigation at each file change. Teeth in groups II and IV were dressed with calcium hydroxide (Ca(OH)(2))/1% chlorhexidine (CHX) paste for 15 days before root filling. Group I and III teeth did not receive an intracanal dressing. The access openings of the teeth were permanently restored with silver amalgam condensed on a glass ionomer cement base. Pairs of standardized periapical radiographs were taken at the beginning of the treatment (0 days) and at 30, 75, and 120 days after filling.Results. There was no significant difference in the rate of radiographic healing of the periapical lesions between manual and rotary instrumentation. Radiographs taken at 120 days showed that the treatment with Ca(OH)(2)/1% CHX paste resulted in a significant reduction in mean size of the periapical lesions in comparison to single-session treatment. These findings were also true for histologic observations.Conclusion. The findings support the hypothesis that, regardless of the instrumentation technique (manual or rotary), the use of an intracanal dressing is important in the endodontic treatment of dog's teeth with experimentally induced chronic periapical lesions.
Resumo:
Objective: the aim of this study was to evaluate the biomechanical preparation of flattened root canals using the following systems: Endo-Eze AET stainless steel oscillatory instruments (Ultradent) and RaCe rotary NiTi instruments (FKG Dentaire). Materials and Methods: Twenty extracted human mandibular incisors were randomly assigned to two groups: Group I Instrumentation with oscillatory Endo-Eze AET files (oscillatory technique); Group 2 - Instrumentation with rotary NiTi RaCe files (rotary technique). The teeth were decoronated, had their apices and coronal openings sealed with sticky wax and were embedded in crystal-clear orthophtalic polyester resin. The roots were sectioned transversally with diamond discs at 10 mm (middle third) and 5 mm (apical third) from the apex and the segments were reassembled for instrumentation. The sections were photographed before and after root canal instrumentation and evaluated with respect to whether the original root canal shape was modified by instrumentation. To evaluate the differences in the root canal shape before and after biomechanical preparation, scores were given regarding the instruments touch on the intracanal walls. Results: In middle third of the root canals instrumented with the rotary system, there was a change in the original canal anatomy (p < 0.05), with formation of a protuberance in the mesiodistal direction. This protuberance did not occur when the oscillatory instrumentation was used. The oscillatory system had better results in the middle and apical thirds as evaluated by Dunn's multiple-comparison test (p > 0.05). Conclusion: Under the tested conditions, Endo-Eze oscillatory system yielded the instrumentation of all flattened oot canal walls, maintaining the canal original shape throughout the biomechanical preparation, and was more effective than RaCe rotary system.
Resumo:
This study aimed at evaluating the antisepsis of the root canal system (RCS) and periapical region (PR) provided by rotary instrumentation associated with chlorhexidine + calcium hydroxide as intracanal medicament. Chronic periapical lesions were induced in 26 pre-molar roots in two dogs. After microbiological sampling, automatic instrumentation using the Profile system and irrigation with 5.25% sodium hypochlorite solution, with a final rinse of 14.3% EDTA followed by profuse irrigation with physiological saline were carried out in 18 root canals. After drying the canals, a paste based on calcium hydroxide associated with a 2% chlorhexidine digluconate solution was placed inside them. After 21 days, the medication was removed, leaving the root canals empty and coronally sealed. After 96 hours, a final microbiological sample was obtained, followed by histomicrobiological processing by the Brown & Brenn method. Eight untreated root canals represented the control group (C-G). Based on the Mann-Whitney test at a confidence level of 5% (p < 0.05), the procedures of antisepsis used offered significant efficacy (p < 0.05) resulting in 100.0% of the canals free of microorganisms. In the C-G, an elevated incidence of various microbial morphotypes was confirmed in all sites of the RCS, with the presence of microbial colonies in the periapical region. In contrast, the experimental group showed a similar pattern of infection in the RCS, although less intense and a reduced level of periapical infection (p < 0.05). It was concluded that adequate instrumentation followed by the application of calcium hydroxide + chlorhexidine offered significant elimination of microorganisms.