987 resultados para pull-up testing
Resumo:
Purpose: Transanal endorectal pull-through (TEPT) has drastically changed the treatment of Hirschsprung`s disease (HD). A short follow-up of children Submitted to TEPT reveals results that are similar to the classic transabdominal pull-through procedures. However, few reports compare the late results of TEPT with transabdominal pull-through procedures with respect to complication rates and the fecal continence. The aims of the present work are to describe some technical refinements that we introduced in the procedure and to compare the short and long-term outcome of TEPT with the outcomes of a group of patients with HD who previously underwent the Duhamel procedure. Methods: Thirty-five patients who underwent TEPT were prospectively studied and compared to a group of 29 patients who were treated with colostomy followed by a classical Duhamel pull-through. The main modifications introduced in the TEPT group were no preoperative colon preparation, operation conducted under general anesthesia in addition to regional sacral anesthesia, use of only one purse-string Suture in the rectal mucosa before transanal submucosal dissection, and no use of retractors and electrocautery during file submucosal dissection. Results: The most frequent early complications of TEPT group were perineal dermatitis (22.8%) and anastomotic strictures (8.6%). The comparison with patients who underwent Duhamel procedure revealed no difference in the incidence of preoperative enterocolitis, the patients of the TEPT group were younger at the time of diagnosis and of surgery, they had shorter operating times, and they began oral feeding more quickly after the operation. The incidence of wound infection was lower in the TEPT group. Moreover, the TEPT and Duhamel groups showed no difference in the incidences of mortality, postoperative partial continence, and total incontinence. Although the incidences of complete continence and postoperative enterocolitis were not different, a tendency to the increased incidence in the TEPT group was observed. Conclusions: This study further supports the technical advantages, the simplicity, and the decreased incidence of complications of a primary TEPT procedure when compared to a classical form of pull-through. Sonic technical refinements are described, and no preoperative colon preparation was necessary for the patients studied here. The results show that the long-term outcomes of the modified TEPT procedure are generally better than those obtained with classical approaches. Published by Elsevier Inc.
Resumo:
Abad, CCC, Prado, ML, Ugrinowitsch, C, Tricoli, V, and Barroso, R. Combination of general and specific warm-ups improves leg-press one repetition maximum compared with specific warm-up in trained individuals. J Strength Cond Res 25(8): 2242-2245, 2011-Accurate assessment of muscular strength is critical for exercise prescription and functional evaluation. The warm-up protocol may affect the precision of the 1 repetition maximum (1RM) test. Testing guidelines recommend performing both general and specific warm-ups before strength tests. The general warm-up intends to raise muscle temperature, whereas the specific warm-up aims to increase neuromuscular activation. Although there is scientific evidence for performing the specific warm-up, the effects of general warm-up on strength tests are still unclear. The purpose of this study was to investigate whether the combination of a general with a specific warm-up (G + SWU) protocol would improve leg press 1RM values compared with a specific warm-up (SWU) protocol. Thirteen participants were tested for leg-press 1RM under 2 warm-up conditions. In the first condition, participants performed the SWU only, which was composed of 1 set of 8 repetitions at approximately 50% of the estimated 1RM followed by another set of 3 repetitions at 70% of the estimated 1RM. In the second condition (G + SWU), participants performed the 1RM test after a 20-minute general warm-up on a stationary bicycle at 60% of HRmax and the same specific warm-up as in the SWU. Values of 1RM in SWU and in G + SWU were compared by a paired t-test, and significance level was set at p <= 0.05. Strength values were on average 8.4% (p = 0.002) higher in the G + SWU compared with the SWU. These results suggest that the G + SWU induced temperature-dependent neuromuscular adjustments that increased muscle force production capacity. Therefore, these results support the recommendations of the testing guidelines to perform a moderate intensity general warm-up in addition to the specific warm-up before maximum strength assessments.
Resumo:
This study evaluated the stress levels at the core layer and the veneer layer of zirconia crowns (comprising an alternative core design vs. a standard core design) under mechanical/thermal simulation, and subjected simulated models to laboratory mouth-motion fatigue. The dimensions of a mandibular first molar were imported into computer-aided design (CAD) software and a tooth preparation was modeled. A crown was designed using the space between the original tooth and the prepared tooth. The alternative core presented an additional lingual shoulder that lowered the veneer bulk of the cusps. Finite element analyses evaluated the residual maximum principal stresses fields at the core and veneer of both designs under loading and when cooled from 900 degrees C to 25 degrees C. Crowns were fabricated and mouth-motion fatigued, generating master Weibull curves and reliability data. Thermal modeling showed low residual stress fields throughout the bulk of the cusps for both groups. Mechanical simulation depicted a shift in stress levels to the core of the alternative design compared with the standard design. Significantly higher reliability was found for the alternative core. Regardless of the alternative configuration, thermal and mechanical computer simulations showed stress in the alternative core design comparable and higher to that of the standard configuration, respectively. Such a mechanical scenario probably led to the higher reliability of the alternative design under fatigue.
Resumo:
Bond's method for ball mill scale-up only gives the mill power draw for a given duty. This method is incompatible with computer modelling and simulation techniques. It might not be applicable for the design of fine grinding ball mills and ball mills preceded by autogenous and semi-autogenous grinding mills. Model-based ball mill scale-up methods have not been validated using a wide range of full-scale circuit data. Their accuracy is therefore questionable. Some of these methods also need expensive pilot testing. A new ball mill scale-up procedure is developed which does not have these limitations. This procedure uses data from two laboratory tests to determine the parameters of a ball mill model. A set of scale-up criteria then scales-up these parameters. The procedure uses the scaled-up parameters to simulate the steady state performance of full-scale mill circuits. At the end of the simulation, the scale-up procedure gives the size distribution, the volumetric flowrate and the mass flowrate of all the streams in the circuit, and the mill power draw.
Resumo:
Background: Temporal lobe epilepsy (TLE) is a neurological disorder that directly affects cortical areas responsible for auditory processing. The resulting abnormalities can be assessed using event-related potentials (ERP), which have high temporal resolution. However, little is known about TLE in terms of dysfunction of early sensory memory encoding or possible correlations between EEGs, linguistic deficits, and seizures. Mismatch negativity (MMN) is an ERP component – elicited by introducing a deviant stimulus while the subject is attending to a repetitive behavioural task – which reflects pre-attentive sensory memory function and reflects neuronal auditory discrimination and perceptional accuracy. Hypothesis: We propose an MMN protocol for future clinical application and research based on the hypothesis that children with TLE may have abnormal MMN for speech and non-speech stimuli. The MMN can be elicited with a passive auditory oddball paradigm, and the abnormalities might be associated with the location and frequency of epileptic seizures. Significance: The suggested protocol might contribute to a better understanding of the neuropsychophysiological basis of MMN. We suggest that in TLE central sound representation may be decreased for speech and non-speech stimuli. Discussion: MMN arises from a difference to speech and non-speech stimuli across electrode sites. TLE in childhood might be a good model for studying topographic and functional auditory processing and its neurodevelopment, pointing to MMN as a possible clinical tool for prognosis, evaluation, follow-up, and rehabilitation for TLE.
Resumo:
The hidden-node problem has been shown to be a major source of Quality-of-Service (QoS) degradation in Wireless Sensor Networks (WSNs) due to factors such as the limited communication range of sensor nodes, link asymmetry and the characteristics of the physical environment. In wireless contention-based Medium Access Control protocols, if two nodes that are not visible to each other transmit to a third node that is visible to the formers, there will be a collision – usually called hidden-node or blind collision. This problem greatly affects network throughput, energy-efficiency and message transfer delays, which might be particularly dramatic in large-scale WSNs. This technical report tackles the hidden-node problem in WSNs and proposes HNAMe, a simple yet efficient distributed mechanism to overcome it. H-NAMe relies on a grouping strategy that splits each cluster of a WSN into disjoint groups of non-hidden nodes and then scales to multiple clusters via a cluster grouping strategy that guarantees no transmission interference between overlapping clusters. We also show that the H-NAMe mechanism can be easily applied to the IEEE 802.15.4/ZigBee protocols with only minor add-ons and ensuring backward compatibility with the standard specifications. We demonstrate the feasibility of H-NAMe via an experimental test-bed, showing that it increases network throughput and transmission success probability up to twice the values obtained without H-NAMe. We believe that the results in this technical report will be quite useful in efficiently enabling IEEE 802.15.4/ZigBee as a WSN protocol.
Resumo:
The main goals of the present work are the evaluation of the influence of several variables and test parameters on the melt flow index (MFI) of thermoplastics, and the determination of the uncertainty associated with the measurements. To evaluate the influence of test parameters on the measurement of MFI the design of experiments (DOE) approach has been used. The uncertainty has been calculated using a "bottom-up" approach given in the "Guide to the Expression of the Uncertainty of Measurement" (GUM). Since an analytical expression relating the output response (MFI) with input parameters does not exist, it has been necessary to build mathematical models by adjusting the experimental observations of the response variable in accordance with each input parameter. Subsequently, the determination of the uncertainty associated with the measurement of MFI has been performed by applying the law of propagation of uncertainty to the values of uncertainty of the input parameters. Finally, the activation energy (Ea) of the melt flow at around 200 degrees C and the respective uncertainty have also been determined.
Resumo:
The clinical and public health importance of indeterminate results in HIV-1/2 testing is still difficult to evaluate in volunteer blood donors. At Fundação Hemominas, HIV-1/2 ELISA is used as the screening test and, if reactive, is followed by Western blot (WB). We have evaluated 84 blood donors who had repeatedly reactive ELISA tests for HIV-1/2, but indeterminate WB results. Sixteen of the 84 donors (19.0%) had history of sexually transmitted diseases; 18/84 (21.4%) informed receiving or paying for sex; 3/84 (3.6%) had homosexual contact; 2/26 women (7.6%) had past history of multiple illegal abortions and 3/84 (3.6%) had been previously transfused. Four out of 62 donors (6.5%) had positive anti-nuclear factor (Hep2), with titles up to 1:640. Parasitological examination of the stool revealed eggs of S. mansoni in 4/62 (6.4%) donors and other parasites in 8/62 (12.9%). Five (5.9%) of the subjects presented overt seroconversion for HIV-1/2, 43/84 (51.2%) had negative results on the last visit, while 36/84 (42.9%) remained WB indeterminate. Although some conditions could be found associated with the HIV-1/2 indeterminate WB results and many donors had past of risky behavior, the significance of the majority of the results remains to be determined.
Resumo:
INTRODUCTION: A growing body of evidence shows the prognostic value of oxygen uptake efficiency slope (OUES), a cardiopulmonary exercise test (CPET) parameter derived from the logarithmic relationship between O(2) consumption (VO(2)) and minute ventilation (VE) in patients with chronic heart failure (CHF). OBJECTIVE: To evaluate the prognostic value of a new CPET parameter - peak oxygen uptake efficiency (POUE) - and to compare it with OUES in patients with CHF. METHODS: We prospectively studied 206 consecutive patients with stable CHF due to dilated cardiomyopathy - 153 male, aged 53.3±13.0 years, 35.4% of ischemic etiology, left ventricular ejection fraction 27.7±8.0%, 81.1% in sinus rhythm, 97.1% receiving ACE-Is or ARBs, 78.2% beta-blockers and 60.2% spironolactone - who performed a first maximal symptom-limited treadmill CPET, using the modified Bruce protocol. In 33% of patients an cardioverter-defibrillator (ICD) or cardiac resynchronization therapy device (CRT-D) was implanted during follow-up. Peak VO(2), percentage of predicted peak VO(2), VE/VCO(2) slope, OUES and POUE were analyzed. OUES was calculated using the formula VO(2) (l/min) = OUES (log(10)VE) + b. POUE was calculated as pVO(2) (l/min) / log(10)peakVE (l/min). Correlation coefficients between the studied parameters were obtained. The prognosis of each variable adjusted for age was evaluated through Cox proportional hazard models and R2 percent (R2%) and V index (V6) were used as measures of the predictive accuracy of events of each of these variables. Receiver operating characteristic (ROC) curves from logistic regression models were used to determine the cut-offs for OUES and POUE. RESULTS: pVO(2): 20.5±5.9; percentage of predicted peak VO(2): 68.6±18.2; VE/VCO(2) slope: 30.6±8.3; OUES: 1.85±0.61; POUE: 0.88±0.27. During a mean follow-up of 33.1±14.8 months, 45 (21.8%) patients died, 10 (4.9%) underwent urgent heart transplantation and in three patients (1.5%) a left ventricular assist device was implanted. All variables proved to be independent predictors of this combined event; however, VE/VCO2 slope was most strongly associated with events (HR 11.14). In this population, POUE was associated with a higher risk of events than OUES (HR 9.61 vs. 7.01), and was also a better predictor of events (R2: 28.91 vs. 22.37). CONCLUSION: POUE was more strongly associated with death, urgent heart transplantation and implantation of a left ventricular assist device and proved to be a better predictor of events than OUES. These results suggest that this new parameter can increase the prognostic value of CPET in patients with CHF.
Resumo:
Dissertação para obtenção do Grau de Doutor em Bioengenharia
Resumo:
Companies and researchers involved in developing miniaturized electronic devices face the basic problem of the needed batteries size, finite life of time and environmental pollution caused by their final deposition. The current trends to overcome this situation point towards Energy Harvesting technology. These harvesters (or scavengers) store the energy from sources present in the ambient (as wind, solar, electromagnetic, etc) and are costless for us. Piezoelectric devices are the ones that show a higher power density, and materials as ceramic PZT or polymeric PVDF have already demonstrated their ability to act as such energy harvester elements. Combinations between piezoelectric and electromagnetic mechanism have been also extensively investigated. Nevertheless, the power generated by these combinations is limited under the application of small magnetic fields, reducing the performance of the energy harvester [1]. In the last years the appearance of magnetoelectric (ME) devices, in which the piezoelectric deformation is driven by the magnetostrictive element, enables to extract the energy of very small electromagnetic signals through the generated magnetoelectric voltage at the piezoelectric element. However, very little work has been done testing PVDF polymer as piezoelectric constituent of the ME energy harvester device, and only to be proposed as a possibility of application [2]. Among the advantages of using piezopolymers for vibrational energy harvesting we can remember that they are ductile, resilient to shock, deformable and lightweight. In this work we demonstrate the feasibility of using magnetostrictive Fe-rich magnetic amorphous alloys/piezoelectric PVDF sandwich-type laminated ME devices as energy harvesters. A very simple experimental set-up will show how these laminates can extract energy, in amounts of μW, from an external AC field.
Resumo:
Regular stair climbing has well-documented health dividends, such as increased fitness and strength, weight loss and reduced body fat, improved lipid profiles and reduced risk of osteoporosis. The general absence of barriers to participation makes stair climbing an ideal physical activity (PA) for health promotion. Studies in the US and the UK have consistently shown that interventions to increase the accumulation of lifestyle PA by climbing stairs rather than using the escalators are effective. However, there are no previous in Catalonia. This project tested one message for their ability to prompt travelers on the Montjuïc site to choose the stairs rather than the escalator when climbing up the Monjuïc hill. One standard message, " Take the stairs! 7 minutes of stair climbing a day protects your heart" provided a comparison with previous research done in the UK. Translated into Catalan and Spanish, it was presented on a poster positioned at the point of choice between the stairs and the escalator. The study used a quasi-experimental, interrupted time series design. Travelers, during several and specific hours on two days of the week, were coded for stair or escalator use, gender, age, ethnic status, presence of accompanying children or bags by one observer. Overall, the intervention resulted in a 81% increase in stair climbing. In the follow-up period without messages, stair climbing dropped out to baseline levels. This preliminary study showed a significant effect on stair use. However, caution is needed since results are based on a small sample and, only a low percentage of the sample took the stairs at baseline or the intervention phase . Future research on stair use in Catalonia should focus on using bigger samples, different sites (metro stations, airports, shopping centers, etc) , different messages and techniques to promote stair climbing.
Resumo:
Clinical and serological follow up examinations were performed on 203 persons, from three to twenty years of age, from the otolaryngology department of a hospital in the city of Rio de Janeiro, with no symptomatology suggesting toxoplasmosis, but suffering from chronic tonsillitis. According to results obtained during the first indirect immunofluorescence tests, the patients were divided into following groups: Group I (non-reactive IgG and IgM), 98 persons (48.3%); Group II (1:16 ≤ IgG ≤ 1:256 and non-reactive IgM), 74 persons (36.5%); Group III (IgM ≥ 1:1024 and non-reactive IgM), 18 persons (8.8%), and Group IV (IgG and IgM reactive), 13 persons (6.4%). One to two years later, 131 (64.5%) of the 203 persons were reexamined by a second indirect immunofluorescence test. In the case of 66 persons (Group I) whose serum was non-reactive in the IgG and IgM classes during the first indirect immunofluorescence test, serum conversion was observed in aproximately 21.2%. in 65 individuals (49.6%), (Groups II, III and IV),with reactive serum in the IgG classes during the first indirect immunofluorescence test, the second reaction showed an increase in titres in 20% of the cases, a decrease in 67.7% of the cases, or no alterations in 12.3 of the cases. In the IgM class, all 131 sera were non-reactive at 116 dilution the second immunofluorescence test, including the 13 cases that had previously been reactive in the immunoglobulin class, Symptomatology suggesting toxoplasmosis was only observed in one case during the second testing, this patient's principal physical sign being hypertrophied lymph nodes. during this period, the Toxoplasma antibodies showed titres of IgG 1:32000 and non-reactive IgM, whilst one year previously, during the first test, these titres were IgG 1:1024 and IgM 1:64. Differences in the age, sex and skin coloring of patients were not statistically significant as regards alterations in the indirect immunofluorescence test titres.
Resumo:
We develop tests of the proportional hazards assumption, with respect to a continuous covariate, in the presence of unobserved heterogeneity with unknown distribution at the individual observation level. The proposed tests are specially powerful against ordered alternatives useful for modeling non-proportional hazards situations. By contrast to the case when the heterogeneity distribution is known up to …nite dimensional parameters, the null hypothesis for the current problem is similar to a test for absence of covariate dependence. However, the two testing problems di¤er in the nature of relevant alternative hypotheses. We develop tests for both the problems against ordered alternatives. Small sample performance and an application to real data highlight the usefulness of the framework and methodology.
Resumo:
ABSTRACT: BACKGROUND: Cardiovascular magnetic resonance (CMR) has favorable characteristics for diagnostic evaluation and risk stratification of patients with known or suspected CAD. CMR utilization in CAD detection is growing fast. However, data on its cost-effectiveness are scarce. The goal of this study is to compare the costs of two strategies for detection of significant coronary artery stenoses in patients with suspected coronary artery disease (CAD): 1) Performing CMR first to assess myocardial ischemia and/or infarct scar before referring positive patients (defined as presence of ischemia and/or infarct scar to coronary angiography (CXA) versus 2) a hypothetical CXA performed in all patients as a single test to detect CAD. METHODS: A subgroup of the European CMR pilot registry was used including 2,717 consecutive patients who underwent stress-CMR. From these patients, 21% were positive for CAD (ischemia and/or infarct scar), 73% negative, and 6% uncertain and underwent additional testing. The diagnostic costs were evaluated using invoicing costs of each test performed. Costs analysis was performed from a health care payer perspective in German, United Kingdom, Swiss, and United States health care settings. RESULTS: In the public sectors of the German, United Kingdom, and Swiss health care systems, cost savings from the CMR-driven strategy were 50%, 25% and 23%, respectively, versus outpatient CXA. If CXA was carried out as an inpatient procedure, cost savings were 46%, 50% and 48%, respectively. In the United States context, cost savings were 51% when compared with inpatient CXA, but higher for CMR by 8% versus outpatient CXA. CONCLUSION: This analysis suggests that from an economic perspective, the use of CMR should be encouraged as a management option for patients with suspected CAD.