964 resultados para prostheses and implants


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND It is unknown if lack of polymer can provoke a different edge response in drug-eluting stents. The aim of this study was to compare edge vascular response between polymer-free paclitaxel-eluting stent (PF-PES) and polymer-based paclitaxel-eluting stents (PB-PES). METHODS AND RESULTS: A total of 165 eligible patients undergoing percutaneous coronary intervention were prospectively randomized 1:1 to receive either PF-PES or PB-PES. Those patients with paired intravascular ultrasound (IVUS) after procedure and at 9-month follow-up were included in this analysis.Seventy-six patients with 84 lesions, divided into PB-PES (38 patients, 41 lesions) and PF-PES groups (38 patients, 43 lesions) had paired post-procedure and 9-month follow-up IVUS and were therefore included in this substudy. There was a significant lumen decrease at the proximal edge of PF-PES (from 9.02±3.06 mm(2)to 8.47±3.05 mm(2); P=0.040), and a significant plaque increase at the distal edges of PF-PES (from 4.39±2.73 mm(2)to 4.78±2.63 mm(2); P=0.004). At the distal edge there was a significant plaque increase in the PF-PES compared to PB-PES (+8.0% vs. -0.6%, respectively; P=0.015) with subsequent lumen reduction (-5.2% vs. +6.0%, respectively; P=0.024). CONCLUSIONS PF-PES had significant plaque increase and lumen reduction at the distal edge as compared to PB-PES, probably due to difference in polymer-based drug-release kinetics between the 2 platforms.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mouse interleukin 3 (IL-3) cDNA was cloned into a plasmid construction, allowing the synthesis of very high quantities of IL-3 in Escherichia coli. The recombinant (r) IL-3, purified to homogeneity, was active in vitro on the proliferation and differentiation of various hematopoietic progenitor cells at 1 pM. To maintain detectable blood levels of IL-3, osmotic pumps containing rIL-3 or control solutions were placed under the skin of normal and irradiated C3H/HeJ and (BALB X B10) F1 mice. The effect of IL-3 on hematopoietic progenitor cell numbers in spleen and bone marrow was evaluated 3 and 7 days later by using an in vitro clonal assay. The results demonstrated the following: (i) Doses of IL-3 infused at the rate of 2.5-5 ng per g of body weight per hr were sufficient to increase the numbers of hematopoietic progenitors in normal mice by at least 2-fold within 3 days. (ii) In mice with progenitor cell levels depressed by sublethal irradiation, 7-day treatment with IL-3 resulted in a 10-fold increase to near normal levels. (iii) The erythroid and myeloid lineages appeared to be enhanced to the same extent. (iv) Enhancement of hematopoiesis occurred primarily in spleen, but hematopoietic foci were also evident in the liver; in contrast, total cell and progenitor cell numbers were decreased in the bone marrow.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of cages of different material and shapes for cervical discectomy with fusion (ACDF) has increased during the last few years. The use of additional osteogenic material is controversial. We prospectively evaluated an empty, Plasmapore-covered titanium cage (PCTC) in 45 patients undergoing 58 ACDFs. Patients were evaluated using standard clinical and radiological criteria. Good to excellent outcome was achieved in 93%, 78% and 75% after 3, 12 and 48 months, respectively. Sixty-five percent of patients could resume their prior work after 48 months. Disc space height and lordosis could be preserved in all cases. Two percent of the treated levels showed subsidence and 2% increased segmental motion. There were no procedure-related complications. Implantation of an empty PCTC after microsurgical anterior cervical discectomy is a safe procedure with good results and low incidence of complications. Disc height and lordosis can be preserved with low incidence of subsidence and good fusion rates.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To evaluate the long-term success rate and complications of nonpenetrating deep sclerectomy with collagen implant in open-angle glaucoma. PATIENTS AND METHODS: Clinical, prospective, monocentric, nonrandomized, unmasked study on 105 patients with medically uncontrolled glaucoma. A standard procedure deep sclerectomy with collagen implant was performed. Complete examinations were performed before surgery and postoperatively at 1 and 7 days; 1, 2, 3, 6, 9, and 12 months and then every 6 months during the 10 following years. RESULTS: The mean follow-up was 101.5+/-43.1 (3 to 144) months [mean+/-SD, (range)]. The preoperative intraocular pressure (IOP) was 26.8+/-7.7 (14 to 52) mm Hg and the best-corrected visual acuity 0.71+/-0.33 (0.02 to 1.5). Ten years after surgery IOP was 12.2+/-4.7 (6 to 20) mm Hg and best-corrected visual acuity 0.63+/-0.34 (0.01 to 1.2) (number of remaining patients=52). The mean number of medications per patient went from 2.3+/-0.7 (1 to 4) down to 1.3+/-1.1 (0 to 3). An IOP <or=21 mm Hg without medication was achieved in 47.7% patients and in 89% with or without treatment. One major complication was reported. Goniopuncture was performed in 61 eyes (59.8%), 5-fluorouracil treatment given to 25 patients postoperatively and included needling (n=5). CONCLUSIONS: On the basis of a 10-year follow-up deep sclerectomy with collagen implant demonstrated its efficacy in controlling IOP with few postoperative complications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Chronic atrial fibrillation affects millions of people worldwide. Its surgical treatment often fails to restore the transport function of the atrium. This study first introduces the concept of an atrial assist device (AAD) to restore the pump function of the atrium. The AAD is developed to be totally implantable in the human body with a transcutaneous energy transfer system to recharge the implanted battery. The ADD consists of a motorless pump based on artificial muscle technology, positioned on the external surface of the atrium to compress it and restore its muscular activity. A bench model reproduces the function of a fibrillating atrium to assess the circulatory support that this pump can provide. Atripump (Nanopowers SA, Switzerland) is a dome-shaped silicone-coated nitinol actuator 5 mm high, sutured on the external surface of the atrium. A pacemaker-like control unit drives the actuator that compresses the atrium, providing the mechanical support to the blood circulation. Electrical characteristics: the system is composed of one actuator that needs a minimal tension of 15 V and has a maximum current of 1.5 A with a 50% duty cycle. The implantable rechargeable battery is made of a cell having the following specifications: nominal tension of a cell: 4.1 V, tension after 90% of discharge: 3.5 V, nominal capacity of a cell: 163 mA h. The bench model consists of an open circuit made of latex bladder 60 mm in diameter filled with water. The bladder is connected to a vertically positioned tube that is filled to different levels, reproducing changes in cardiac preload. The Atripump is placed on the outer surface of the bladder. Pressure, volume and temperature changes were recorded. The contraction rate was 1 Hz with a power supply of 12 V, 400 mA for 200 ms. Preload ranged from 15 to 21 cm H(2)O. Maximal silicone membrane temperature was 55 degrees C and maximal temperature of the liquid environment was 35 degrees C. The pump produced a maximal work of 16 x 10(-3) J. Maximal volume pumped was 492 ml min(-1). This artificial muscle pump is compact, follows the Starling law and reproduces the hemodynamic performances of a normal atrium. It could represent a new tool to restore the atrial kick in persistent atrial fibrillation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Numerous drug delivery systems (DDSs) can be used as intraocular tools to provide a sustained and calibrated release for a specific drug. Great progress has been made on the design, biocompatibility, bioavailability, and efficacy of DDSs. Although several of them are undergoing clinical trials, a few are already on the market and could be of a routine use in clinical practice. Moreover, miniaturization of the implants makes them less and less traumatic for the eye tissues and some DDSs are now able to target certain cells or tissues specifically. An overview of ocular implants with therapeutic application potentials is provided.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The implantable loop recorder developed by Medtronic (Reveal plus) is a small device inserted subcutaneously under local anesthesia in patients with syncope of unexplained origin. This device enables a single lead-ECG recording and has autonomy of two years. Memories are activated during episodes of bradycardia or tachycardia, either automatically or manually. Several studies have shown a high diagnostic rate reaching 50% and demonstrated its cost-effectiveness. There is also a significant reduction in syncopal episodes and a higher quality of life score in patients with syncope of unexplained origin.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To compare the efficacy and safety of T-Flux implant versus Healon GV in deep sclerectomy. METHODS: Randomized prospective trial of 23 eyes of 20 patients with medically uncontrolled open angle glaucoma over a period of 24 months, who underwent deep sclerectomy with either Healon GV or T-Flux implant. RESULTS: Mean postoperative intraocular pressure was 13.2 +/- 3.0 mm Hg with T-Flux implant (group 1) and 12.2 +/- 3.5 mm Hg with Healon GV (group 2), with a pressure reduction of 53.0% in group 1 (13.2 mm Hg vs. 28.1 mm Hg) and of 48.1% in group 2 (12.2 mm Hg vs. 23.5 mm Hg). Qualified and complete successes were 100% and 95.4% respectively. Pressures equal to or less than 15 mm Hg were 81.8% in group 1 and 90.9% in group 2 with or without treatment, and 63.6% in group 1 and 81.8% in group 2 without treatment. The number of glaucoma treatments dropped from 2.5 +/- 0.9 to 0.4 +/- 0.7 in group 1 and from 2.2 +/- 1.0 to 0.2 +/- 0.4 in group 2. The goniopuncture rate was 63.6% in group 1 and 36.4% in group 2, with a mean pressure drop of 6.1 +/- 3.9 mm Hg and 3.25 +/- 1.2 mm Hg respectively. Overall, slit-lamp diagnosed surgery-related complications included positive Seidel (13.6%), hyphaema (22.7%), choroidal detachment, and iris incarceration (4.5% each). At 2 years, ultrasound biomicroscopy showed mainly low reflective (40.1%) and flattened (36.4%) blebs. Principally latter ones were associated with the need for adjunctive treatment. A hypoechoic area in the suprachoroidal space was seen in at least 59.1% of eyes at 2 years and was not associated with lower intraocular pressure. CONCLUSION: Deep sclerectomy is an effective and safe surgery. However, longer follow up and larger study groups are required to assess the additional benefit of nonabsorbable implants.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective is to alert the surgeon about the indiscriminate use of synthetic prosthesis in the correction of inguinal and incisional hernias. The authors provide a brief history of surgery on hernias and a review of the literature, showing the importance of classifying inguinal hernias to fit the type of surgical correction with the defect found, abstaining from treating all hernias, with the same type of surgical procedure. In our opinion, small indirect inguinal hernias (type 1 and 2 of Gilbert) and hernias in women must not, in general, be treated with prostheses. The synthetic material should be reserved for direct and large indirect hernias. Even so, this attitude, besides determining a higher cost for the procedure, can lead to important complications such as infection, rejection, fistula formation, chronic pain, alterations in spermatogenesis and the possibility of carcinogenesis, according to more recent reports. The physiology and anatomy of the abdominal wall should be considered when dealing with incisional hernia corrections, where the surgeon can choose among many techniques to correct those defects, and in selected cases, utilize synthetic material. We conclude that although the use of biomaterials has constituted a great advance in surgery for abdominal wall hernia corrections because they decrease recurrences, and permit treatment of large abdominal hernias, the indiscriminate prosthesis usage is an abuse, and it can determine many serious complications, certainly avoidable with a well indicated non mesh technique .

Relevância:

100.00% 100.00%

Publicador:

Resumo:

For oral rehabilitation with implant-supported prostheses, there are required procedures to create the bone volume needed for installation of the implants. Thus, bone grafts from intraoral or extraoral donor sites represent a very favorable opportunity. This study aimed to review the literature on the subject, seeking to discuss parameters for the indications, advantages and complications of techniques for autogenous bone grafts.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Significant morbidity and mortality are related to conventional aortic replacement surgery. Endovascular debranching techniques, fenestrated or branched endografts are time consuming and costly.Objective: We alternatively propose to use endovascular approach with parallel grafts for debranching of aortic arch.Methods: Under general anesthesia, 12 F sheaths were inserted in the femoral, axillary and common carotid arteries for vascular accesses. ViaBahn grafts 10 - 15 cm in length were placed into the aortic arch from right common carotid, left common carotid and left axillary arteries, until the tip of each graft reached into the ascending aorta. Through one femoral artery, the aortic stent-graft was positioned and delivered. Soon after, the parallel grafts were sequentially delivered. Self-spanding Wallstents(R) were used for parallel grafts reinforcement. Ballooning was routinely used for parallel grafts and rarely for aortic graft.Results: This technique was used in 2 cases. The first one was a lady with 72 years old, with an aortic retrograde dissection from left subclavian artery and involving remaining arch branches. Through right common carotid artery a stent-graft was placed in the ascending aorta and through the left common carotid artery a ViaBahn was inserted parallel to the former. A thoracic endograft then covered all the aortic arch dissection extending into the ascending aorta close to the sinu-tubular junction. The second case was a 82 year old male patient with a 7 cm aortic arch aneurysm. Through both common carotid arteries ViaBahn grafts were introduced and positioned into the ascending aorta. Soon after, the deployment of the thoracic stent graft covered all parallel grafts of the aortic arch, excluding the aneurysm. Both cases did not have neurologic or cardiac complications and were discharged 10 days after the procedure.Conclusions: This technique may be a good minimal invasive off-the-shelf technical option for aortic arch "debranching". More data and further improvements are required before this promising technique can be widely advocated. (C) 2011 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVOS: Avaliar o posicionamento palpebral em portadores de cavidade anoftálmica com e sem prótese ocular externa, utilizando o processamento de imagem digital. MÉTODOS: Dezoito pacientes foram avaliados qualitativa e quantitativamente na Faculdade de Medicina de Botucatu - Universidade Estadual Paulista - UNESP, com e sem a prótese externa. Usando imagens obtidas por filmadora e processadas usando o programa Scion Image, mediu-se a altura do sulco palpebral superior, a altura da fenda palpebral e os ângulos palpebrais dos cantos interno e externo. RESULTADOS: Pseudo-estrabismo e sulco palpebral superior profundo foram as alterações mais freqüentes ao exame externo. Houve diferença significativa em todas as variáveis estudadas, com diminuição da altura do sulco palpebral superior, aumento da área da fenda palpebral e aumento dos ângulos palpebrais interno e externo quando o paciente estava usando a prótese externa. CONCLUSÃO: Todos os pacientes avaliados apresentaram algum tipo de anormalidade órbito-palpebral, o que reflete a dificuldade em se proporcionar ao portador de cavidade anoftálmica um aspecto idêntico ao que existe na órbita normal. O processamento de imagens digitais permitiu avaliação objetiva das dimensões óculo-palpebrais, o que poderá contribuir nas avaliações seqüenciais dos portadores de cavidade anoftálmica.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The misfit between prostheses and implants is a clinical reality, but the level that can be accepted without causing mechanical or biologic problem is not well defined. This study investigates the effect of different levels of unilateral angular misfit prostheses in the prosthesis/implant/retaining screw system and in the surrounding bone using finite element analysis. Four models of a two-dimensional finite element were constructed: group I (control), prosthesis that fit the implant; groups 2 to 4, prostheses with unilateral angular misfit of 50, 100, and 200 mu m, respectively. A load of 133 N was applied with a 30-degree angulation and off-axis at 2 mm from the long axis of the implant at the opposite direction of misfit on the models. Taking into account the increase of the angular misfit, the stress maps showed a gradual increase of prosthesis stress and uniform stress in the implant and trabecular bone. Concerning the displacement, an inclination of the system due to loading and misfit was observed. The decrease of the unilateral contact between prosthesis and implant leads to the displacement of the entire system, and distribution and magnitude alterations of the stress also occurred.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of the present study was to conduct a critical literature review about the technique of computer-guided surgery in implantology to highlight the indications, purposes, immediate loading of implants and complications, protocol of fabrication, and functioning of virtual planning software. This literature review was based on OLDMEDLINE and MEDLINE databases from 2002 to 2010 using the key words "computer-guided surgery" and "implant-supported prosthesis." Thirty-four studies regarding this topic were found. According to the literature review, it was concluded that the computer-assisted surgery is an excellent treatment alternative for patients with appropriate bone quantity for implant insertion in complete and partially edentulous arches. The Procera Nobel Guide software (Nobel Biocare) was the most common software used by the authors. In addition, the flapless surgery is advantageous for positioning of implants but with accurate indication. Although the computer-guided surgery may be helpful for virtual planning of cases with severe bone resorption, the conventional surgical technique is more appropriate. The surgical guide is important for insertion of the implants regardless of the surgical technique, and the success of immediate loading after computer-guided surgery depends on the accuracy of clinical and/or laboratorial steps.