966 resultados para pressure sensor
Resumo:
The Asian tsunami of 26 December 2004 killed over 220 000 people and devastated coastal structures, including many thousands of traditional brick-built homes. This paper presents the results of model tests that compare the impact of a tsunami wave on a typical coastal house with that on a new tsunami resistant design developed in the USA and now built in Sri Lanka Digital images recorded during the test reveal how the tsunami wave passed through the new house design without damaging it but severely damaged the typical coastal house. Pressure sensor results also provided further insight into tsunami wave loading, indicating that the established Japanese method significantly underestimates maximum impact load.
Resumo:
10 mu m-thick ultra-thin Si (111) membranes for GaN epi-layers growth were successfully fabricated on silicon-on-insulator (SOI) substrate by backside etching the handle Si and buried oxide (BOX) layer. Then 1 mu m-thick GaN layers were deposited on these Si membranes by metal-organic chemical vapor deposition (MOCVD). The crack-free areas of 250 mu m, x 250 mu m were obtained on the GaN layers due to the reduction of thermal stress by using these ultra-thin Si membranes, which was further confirmed by the photoluminescence (PL) spectra and the simulation results from the finite element method calculation by using the software of ANSYS. In this paper, a newly developed approach was demonstrated to utilize micromechanical structures for GaN growth, which would improve the material quality of the epi-layers and facilitate GaN-based micro electro-mechanical system (MEMS) fabrication, especially the pressure sensor, in the future applications. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
依据6000米自治水下机器人及其长基线声学定位系统现有的导航设备,将测距声信标和机器人载体携带的低成本导航传感器:涡轮式计程仪,压力传感器以及TCM2电子罗盘测量的导航数据相融合,分别提出两种基于EKF的导航数据融合算法,对机器人的位置以及水流参数进行估计,解决复杂环境下的深水机器人位置估计问题.蒙特卡洛仿真实验和湖上试验数据后处理表明,设计的位置估计算法收敛快,精度高,计算时间小,能够满足深水机器人的导航需要.
Resumo:
This paper describes a series of experiments undertaken to investigate the slamming of an Oscillating Wave Surge Converter in extreme sea states. These two-dimensional experiments were undertaken in the Wave Flume at Ecole Centrale Marseille. Images from a high speed camera are used to identify the physics of the slamming process. A single pressure sensor is used to record the characteristic of the pressure. Finally numerical results are compared to the output from the experiments.
Resumo:
Este trabalho combina esforços de simulação numérica e de análise de dados para investigar a dinâmica em diversos compartimentos (oceano aberto, plataforma continental e zona costeira-estuarina) e, em multiplas escalas, na Margem Continental Leste Brasileira (MCLB). A circulação de largo e mesoescala espacial e a propagação da maré barotrópica são investigadas através de uma configuração aninhada do modelo numérico ROMS. O estudo da dinâmica regional da Baía de Camamu (CMB) baseia-se na análise de dados locais. A MCLB, localizada a SW do Atlântico Sul entre 8±S e 20±S, possui plataforma estreita, batimetria complexa, e baixa produtividade primária. A sua dinâmica é influenciada pela divergência da Corrente Sul Equatorial (CSE). As simulações refletem as conexões sazonais e espaciais entre a Corrente do Brasil e a Contra Corrente Norte do Brasil , em conexão com a dinâmica da CSE. As simulações revelam atividades vorticais nas proximidades da costa e interações com a dinâmica costeira, cujos padrões são descritos. A validação do modelo em mesoescala é baseada em cálculos de energia cinética turbulenta e em dados históricos de transporte. A CMB, localizada a 13±400S, abriga uma comunidade piscatória tradicional e extenso de manguezal. Situa-se porém sobre uma bacia sedimentar com grande reservas de óleo e gás, estando em tensão permanente de impacto ambiental. Neste trabalho sumarizamos as condições físicas regionais e investigamos sua dinâmica interna, focando sua variabilidade em amostragens realizadas sob condições de seca (Setembro de 2004) e de chuva (Julho de 2005). Finalmente, o modelo numérico ROMS é forçado com o sinal de maré, empregando-se uma configuração simples (com coeficientes de atrito de fundo constantes e condições hidrográficas homogéneas), com o intuito de avaliar sua resposta e investigar a natureza da propagação da maré barotrópica na MCLB, convergindo na CMB. A análise da resposta do modelo à maré basea-se em séries históricas do nível do mar para a MCLB e dados recentes da CMB.
Resumo:
O presente trabalho teve por objectivo global o estudo e desenvolvimento de sensores baseados em fibra óptica polimérica. O crescimento da tecnologia polimérica nos últimos anos permitiu a introdução deste tipo de fibras ópticas na área das telecomunicações e no desenvolvimento de sensores. As vantagens associadas à metrologia óptica com fibra polimérica têm vindo a atrair as atenções da comunidade científica dado que permitem o desenvolvimento de sistemas de baixo-custo ou custo competitivo face às tecnologias convencionais. Dada a actualidade do tema proposto, descreve-se, numa primeira fase, a tecnologia em fibra óptica polimérica existente no mercado e o estado de arte de sensores em fibra óptica polimérica. Segue-se a descrição de dois tipos de sensores baseados em modulação de intensidade. Projectou-se um sensor extrínseco capaz de avaliar a quantidade de luz dispersa e absorvida por partículas suspensas num líquido. Foi efectuada a caracterização do sensor quanto à concentração de partículas suspensas, tamanho e reflectividade. O sensor foi testado no âmbito da monitorização ambiental, designadamente, na análise de turbidez em amostras de sedimentos recolhidos em áreas ardidas. O sistema desenvolvido foi comparado com um sistema comercial. Um sensor intrínseco, baseado no polimento lateral de fibra óptica polimérica, foi analisado analiticamente. O modelo teórico avalia o sensor em diferentes condições de macroencurvamento e de índice de refracção do meio envolvente. O modelo teórico foi validado positivamente através de resultados experimentais. Foi avaliada a sensibilidade à temperatura e os conhecimentos adquiridos foram aplicados no desenvolvimento de um sistema capaz de monitorizar a cura de diferentes materiais. É ainda apresentada uma técnica para melhorar a sensibilidade do sensor de curvatura através da aplicação de um revestimento na zona sensível. A dependência na curvatura da potência transmitida por uma fibra óptica polida lateralmente serviu de base ao desenvolvimento de uma joelheira e de uma cotoveleira instrumentada, capazes de avaliar quantitativamente o movimento articular. A necessidade de portabilidade levou ao desenvolvimento de um sistema sem fios para aquisição e transmissão de dados. Espera-se que os protótipos desenvolvidos venham a ter um impacto significativo em sistemas futuros aplicados à medicina física e reabilitação.
Resumo:
A study was conducted to estimate variation among laboratories and between manual and automated techniques of measuring pressure on the resulting gas production profiles (GPP). Eight feeds (molassed sugarbeet feed, grass silage, maize silage, soyabean hulls, maize gluten feed, whole crop wheat silage, wheat, glucose) were milled to pass a I mm screen and sent to three laboratories (ADAS Nutritional Sciences Research Unit, UK; Institute of Grassland and Environmental Research (IGER), UK; Wageningen University, The Netherlands). Each laboratory measured GPP over 144 h using standardised procedures with manual pressure transducers (MPT) and automated pressure systems (APS). The APS at ADAS used a pressure transducer and bottles in a shaking water bath, while the APS at Wageningen and IGER used a pressure sensor and bottles held in a stationary rack. Apparent dry matter degradability (ADDM) was estimated at the end of the incubation. GPP were fitted to a modified Michaelis-Menten model assuming a single phase of gas production, and GPP were described in terms of the asymptotic volume of gas produced (A), the time to half A (B), the time of maximum gas production rate (t(RM) (gas)) and maximum gas production rate (R-M (gas)). There were effects (P<0.001) of substrate on all parameters. However, MPT produced more (P<0.001) gas, but with longer (P<0.001) B and t(RM gas) (P<0.05) and lower (P<0.001) R-M gas compared to APS. There was no difference between apparatus in ADDM estimates. Interactions occurred between substrate and apparatus, substrate and laboratory, and laboratory and apparatus. However, when mean values for MPT were regressed from the individual laboratories, relationships were good (i.e., adjusted R-2 = 0.827 or higher). Good relationships were also observed with APS, although they were weaker than for MPT (i.e., adjusted R-2 = 0.723 or higher). The relationships between mean MPT and mean APS data were also good (i.e., adjusted R 2 = 0. 844 or higher). Data suggest that, although laboratory and method of measuring pressure are sources of variation in GPP estimation, it should be possible using appropriate mathematical models to standardise data among laboratories so that data from one laboratory could be extrapolated to others. This would allow development of a database of GPP data from many diverse feeds. (c) 2005 Published by Elsevier B.V.
Resumo:
The progressing cavity pump artificial lift system, PCP, is a main lift system used in oil production industry. As this artificial lift application grows the knowledge of it s dynamics behavior, the application of automatic control and the developing of equipment selection design specialist systems are more useful. This work presents tools for dynamic analysis, control technics and a specialist system for selecting lift equipments for this artificial lift technology. The PCP artificial lift system consists of a progressing cavity pump installed downhole in the production tubing edge. The pump consists of two parts, a stator and a rotor, and is set in motion by the rotation of the rotor transmitted through a rod string installed in the tubing. The surface equipment generates and transmits the rotation to the rod string. First, is presented the developing of a complete mathematical dynamic model of PCP system. This model is simplified for use in several conditions, including steady state for sizing PCP equipments, like pump, rod string and drive head. This model is used to implement a computer simulator able to help in system analysis and to operates as a well with a controller and allows testing and developing of control algorithms. The next developing applies control technics to PCP system to optimize pumping velocity to achieve productivity and durability of downhole components. The mathematical model is linearized to apply conventional control technics including observability and controllability of the system and develop design rules for PI controller. Stability conditions are stated for operation point of the system. A fuzzy rule-based control system are developed from a PI controller using a inference machine based on Mandami operators. The fuzzy logic is applied to develop a specialist system that selects PCP equipments too. The developed technics to simulate and the linearized model was used in an actual well where a control system is installed. This control system consists of a pump intake pressure sensor, an industrial controller and a variable speed drive. The PI control was applied and fuzzy controller was applied to optimize simulated and actual well operation and the results was compared. The simulated and actual open loop response was compared to validate simulation. A case study was accomplished to validate equipment selection specialist system
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
O objetivo deste trabalho foi testar o sistema de monitoramento computadorizado da produção de gás in vitro. Essa técnica facilita estudos da degradação das frações solúveis e insolúveis das forragens, quantificadas pela produção de gás (CO2 e CH4) oriunda do metabolismo microbiano e medida por sensor de pressão. Diversas quantidades de amostras (50 a 110 mg de feno de alfafa) e outros alimentos foram testadas. Também, a influência da quantidade de líquido ruminal (2,0 ou 3,0 mL), com ou sem barras magnéticas agitadoras nos frascos incubatórios, na digestibilidade de 100 mg de feno de alfafa, foi estudada. A quantidade de 100 mg de amostra, 2,0 mL de líquido ruminal e sem barra magnética agitadora, proporcionou os menores coeficientes de variação na produção de gás. em conclusão, 2,0 mL de líquido ruminal, sem barra e com 100 mg de amostra, apresentaram maior precisão na curva de digestão.
Resumo:
Evaluating the ability to rectify and maintain lumbar adjustment can contribute toward the understanding of the behavior of abdominal muscles and their participation in the stability of pelvic muscles in dancers during the posterior pelvic tilt and double straight leg lowering tests. Nine healthy volunteers (male and female ballet dancers; age mean: 25.9 ±7.37 years) underwent maximal isometric voluntary contraction (MIVC), isometric voluntary contraction at 50% of MIVC, posterior pelvic tilt (PPT) and double straight leg lowering (DSLL) tests. The tests were carried out in a single day, with 3 repetitions each. During the tests, electromygraphic signals of the rectus abdominis, obliquus internus and obliquus externus were recorded. The signal acquisition system was made up of bipolar surface electrodes, electrogoniometer and an electromechanic device (pressure sensor), which were connected to a signal conditioner module. Root mean square values of each muscle during the DSLL and PPT were converted into percentage of activation of 50% MIVC. Lower back pressure was submitted to the same process. ANOVA with repeated measures was performed, with the level of significance set at p < 0.05. The results revealed that all dancers were able to maintain posterior pelvic tilt and there was trend toward greater activation of the bilateral obliquus internus muscle. In an attempt to keep the pelvic region stabilized during DSLL, there was a greater contribution from the obliquus externus muscle in relation to other abdominal muscles.
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Piezoresistive sensors are commonly made of a piezoresistive membrane attached to a flexible substrate, a plate. They have been widely studied and used in several applications. It has been found that the size, position and geometry of the piezoresistive membrane may affect the performance of the sensors. Based on this remark, in this work, a topology optimization methodology for the design of piezoresistive plate-based sensors, for which both the piezoresistive membrane and the flexible substrate disposition can be optimized, is evaluated. Perfect coupling conditions between the substrate and the membrane based on the `layerwise' theory for laminated plates, and a material model for the piezoresistive membrane based on the solid isotropic material with penalization model, are employed. The design goal is to obtain the configuration of material that maximizes the sensor sensitivity to external loading, as well as the stiffness of the sensor to particular loads, which depend on the case (application) studied. The proposed approach is evaluated by studying two distinct examples: the optimization of an atomic force microscope probe and a pressure sensor. The results suggest that the performance of the sensors can be improved by using the proposed approach.
Resumo:
BACKGROUND: In humans, it is not known whether physical endurance exercise training promotes coronary collateral growth. The following hypotheses were tested: the expected collateral flow reduction after percutaneous coronary intervention of a stenotic lesion is prevented by endurance exercise training; collateral flow supplied to an angiographically normal coronary artery improves in response to exercise training; there is a direct relationship between the change of fitness after training and the coronary collateral flow change. METHODS AND RESULTS: Forty patients (age 61+/-8 years) underwent a 3-month endurance exercise training program with baseline and follow-up assessments of coronary collateral flow. Patients were divided into an exercise training group (n=24) and a sedentary group (n=16) according to the fact whether they adhered or not to the prescribed exercise program, and whether or not they showed increased endurance (VO2max in ml/min per kg) and performance (W/kg) during follow-up versus baseline bicycle spiroergometry. Collateral flow index (no unit) was obtained using pressure sensor guidewires positioned in the coronary artery undergoing percutaneous coronary intervention and in a normal vessel. In the vessel initially undergoing percutaneous coronary intervention, there was an increase in collateral flow index among exercising but not sedentary patients from 0.155+/-0.081 to 0.204+/-0.056 (P=0.03) and from 0.189+/-0.084 to 0.212+/-0.077 (NS), respectively. In the normal vessel, collateral flow index changes were from 0.176+/-0.075 to 0.227+/-0.070 in the exercise group (P=0.0002), and from 0.219+/-0.103 to 0.238+/-0.086 in the sedentary group (NS). A direct correlation existed between the change in collateral flow index from baseline to follow-up and the respective alteration of VO2max (P=0.007) and Watt (P=0.03). CONCLUSION: A 3-month endurance exercise training program augments coronary collateral supply to normal vessels, and even to previously stenotic arteries having undergone percutaneous coronary intervention before initiating the program. There appears to be a dose-response relation between coronary collateral flow augmentation and exercise capacity gained.