942 resultados para polyester prosthesis


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Reversed shoulder arthroplasty is an accepted treatment for glenohumeral arthritis associated to rotator cuff deficiency. For most reversed shoulder prostheses, the baseplate of the glenoid component is uncemented and its primary stability is provided by a central peg and peripheral screws. Because of the importance of the primary stability for a good osteo-integration of the baseplate, the optimal fixation of the screws is crucial. In particular, the amplitude of the tightening force of the nonlocking screws is clearly associated to this stability. Since this force is unknown, it is currently not accounted for in experimental or numerical analyses. Thus, the primary goal of this work is to measure this tightening force experimentally. In addition, the tightening torque was also measured, to estimate an optimal surgical value. METHODS: An experimental setup with an instrumented baseplate was developed to measure simultaneously the tightening force, tightening torque and screwing angle, of the nonlocking screws of the Aquealis reversed prosthesis. In addition, the amount of bone volume around each screw was measured with a micro-CT. Measurements were performed on 6 human cadaveric scapulae. FINDINGS: A statistically correlated relationship (p<0.05, R=0.83) was obtained between the maximal tightening force and the bone volume. The relationship between the tightening torque and the bone volume was not statistically significant. INTERPRETATION: The experimental relationship presented in this paper can be used in numerical analyses to improve the baseplate fixation in the glenoid bone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The vascular access steal syndrome is a complication occurring in 1-6% after native arterio-venous (AV) fistulas, often due to huge diameter of the vein. This results in very high flow, which could also be responsible for cardiac overload. The aim of this study is to evaluate the efficiency of a new approach in the treatment of this pathology using open-pore external scaffolding prosthesis.Methods: This a retrospective review of all patients presenting symptomatic high flow after native AV fistula between January 2007 and December 2009 in 3 vascular centers. Pre-operative duplex exam confirmed the diagnosis of high flow. The operation consisted in preparation of the whole fistula, measurement of the flow and section on the venous side. The vein was wrapped with this 6 to 8 mm open-pore external scaffolding prosthesis (ProVena, BBraun, Germany) according to its diameter and to the flow and then sutured. Measurement of the flow was repeated. Patients were followed by duplex exam at 1 week and at 1, 3, 6 and 12 months. Procedural success was defined as complete implantation of the prosthesis and reduction of the flow. Primary outcomes were reduction of the flow and recovery of the symptoms and secondary endpoint was patency of the fistula.Results: During the study period, 14 patients, with a mean age of 65・8 years old, have been operated with this technique.There were 2 native forearmfistulas and 12 on the armwith a mean pre-operative flow of 2600 ml/min (1800-3800). The mode of presentation was pain in 6 patients, neurological disorders in 10 and necrosis in 4. Moreover, 3 patients had cardiac insufficiency due to high flow in the fistula. The procedure was technically successful in 100% of cases. Re-intervention was necessary in 2 patients due to hematoma. Recovery of the initial symptoms occurred in 13 patients (93%). The mean flow reduction was 1200 ml/min (600-2000). In 1 patient, a persistent steal syndrome despite flow reduction to 1400 ml/min resulted in fistula closure 2 months later. At a mean follow-up of 22 months (4-35), all remaining patients (13/14) presented a patent fistula without recurrence.Conclusion: This new approach seems to be safe and effective in the treatment of symptomatic high flow native AV fistulas by significantly reducing the flow and avoiding closure of the vascular access. Longer follow-up with more patients are necessary to evaluate the risk of recurrence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: This study evaluates sealing characteristics of two designs of endovascular grafts by angiographic demonstration of exclusion of porcine lumbar arteries. METHODS: 6 endovascular grafts (3 self-expandable with integrated polyurethane wall versus 3 nitinol structures covered with polyester fabric) were implanted in 6 porcine aortae. Perfusion of lumbar arteries was assessed by angiography after implantation and by angiography and dissection at graft explantation after 4 +/- 2 months. Tissue healing was evaluated by light and scanning electron microscopy. RESULTS: Immediate exclusion of the lumbar arteries was achieved in 14/31 vessels (12 by polyurethane grafts and 2 by polyester grafts, p < 0.001). Follow-up angiography and dissection at explantation revealed perfusion of 30/31 lumbar arteries with a collateral network in most cases. Another reason for reperfusion of initially excluded branches was distention of the polyurethane grafts with resulting shortening allowing reperfusion of 8 of the 31 originally covered branches. Histological examination revealed a complete neointimal lining and a tight contact between endovascular grafts and aorta. CONCLUSIONS: The immediate angiographic demonstration of exclusion of lumbar arteries predicts sealing characteristics of endovascular grafts. Later angiographic reappearance is due to development of a collateral network and possible shortening of self-expandable devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Reconstructions of the fronto-orbital area remain a challenge to the reconstructive surgeon, due to the functional and esthetic impact. OBSERVATION: The authors present a case of a complex fronto-orbital reconstruction with a PEEK (PolyEtherEtherKetone) implant, associated with a skin expansion. DISCUSSION: With a follow-up of over three years, the cosmetic result is excellent. The authors believe that this technique is reliable, fast with long-term good results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Between September 1979 and December 1982, 56 St Jude Medical valvular prostheses were implanted in 54 patients over 65 years of age. Surgery consisted in simple aortic valve replacement (35 cases), simple mitral valve replacement (12 cases), double aortic and mitral valve replacement (2 cases), valve replacement and coronary artery bypass surgery (3 cases), aortic valve replacement and replacement of the ascending aorta (1 case) and mitral valve replacement and tricuspid annuloplasty (1 case). The operative mortality (within 30 days of surgery) was 3.5% (2 cases). Patients were assessed by clinical examination, ECG, chest X-ray, echocardiogram and laboratory investigations on average 19 months after surgery. There were 3 late deaths (1 endocarditis, 1 cardiac failure and 1 subdural haematoma). No cases of significant haemolysis were observed. There were no cases of thrombosis of the valve or any deaths directly related to the valve. Four patients had cerebral embolism (4.9% per patient/year). None were fatal and only 1 patient had sequellae. Clinical improvement was very significant; 96% of the patients are now in the NYHA Classes I and II whilst 80% were in Class III or IV before surgery. The cardiothoracic ratio decreased significantly from 0.56 to 0.51 (p less than 0.01). The authors conclude that elderly patients may derive great benefits from valvular cardiac surgery and that age in itself is not a contraindication to this type of surgery. The St Jude Medical prosthesis is an excellent prosthesis but thromboembolism remains a major problem as with other mechanical prostheses. Anticoagulation for life is essential.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: The importance of the micromovements in the mechanism of aseptic loosening is clinically difficult to evaluate. To complete the analysis of a series of total knee arthroplasties (TKA), we used a tridimensional numerical model to study the micromovements of the tibial implant. MATERIAL AND METHODS: Fifty one patients (with 57 cemented Porous Coated Anatomic TKAs) were reviewed (mean follow-up 4.5 year). Radiolucency at the tibial bone-cement interface was sought on the AP radiographs and divided in 7 areas. The distribution of the radiolucency was then correlated with the axis of the lower limb as measured on the orthoradiograms. The tridimensional numerical model is based on the finite element method. It allowed the measurement of the cemented prosthetic tibial implant's displacements and the micromovements generated at bone-ciment interface. A total load (2000 Newton) was applied at first vertically and asymetrically on the tibial plateau, thereby simulating an axial deviation of the lower limbs. The vector's posterior inclination then permitted the addition of a tangential component to the axial load. This type of effort is generated by complex biomechanical phenomena such as knee flexion. RESULTS: 81 per cent of the 57 knees had a radiolucent line of at least 1 mm, at one or more of the tibial cement-epiphysis jonctional areas. The distribution of these lucent lines showed that they came out more frequently at the periphery of the implant. The lucent lines appeared most often under the unloaded margin of the tibial plateau, when axial deviation of lower limbs was present. Numerical simulations showed that asymetrical loading on the tibial plateau induced a subsidence of the loaded margin (0-100 microns) and lifting off at the opposite border (0-70 microns). The postero-anterior tangential component induced an anterior displacement of the tibial implant (160-220 microns), and horizontal micromovements with non homogenous distribution at the bone-ciment interface (28-54 microns). DISCUSSION: Comparison of clinical and numerical results showed a relation between the development of radiolucent lines and the unloading of the tibial implant's margin. The deleterious effect of lower limbs' axial deviation is thereby proven. The irregular distribution of lucent lines under the tibial plateau was similar of the micromovements' repartition at the bone-cement interface when tangential forces were present. A causative relation between the two phenomenaes could not however be established. Numerical simulation is a truly useful method of study; it permits to calculate micromovements which are relative, non homogenous and of very low amplitude. However, comparative clinical studies remain as essential to ensure the credibility of results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES Guidelines proposed bioprosthesis implantation for aortic valve disease if the patients were at least 65 years old at the time of surgery, with a trend towards even younger patients in recent years. Considering the adverse effects of lifetime anticoagulation, new biological valves (less prone to degeneration) and new technologies may lead patients and surgeons to different choices. Therefore, it is interesting to analyse the results of aortic bioprosthetic valve replacement in patients aged <65 years at the time of surgery. METHODS From January 2000 to December 2010, 84 patients aged <65 years at the time of surgery had undergone an aortic bio-prosthetic valve replacement. A mid-term follow-up [(FU) mean FU time: 54.4 ± 39.2 months] was done in August 2011 in all patients (FU completeness: 100%). Results were compared with patients who had a mechanical prosthetic aortic valve replacement during the same period. RESULTS The reoperation rate for structural valve degeneration (SVD) of bioprostheses was 6% and occurred exclusively among patients <56 years. Contraindications for anticoagulation determined the choice of a bioprosthesis among 83% of these patients. The personal preference to avoid anticoagulation was the leading cause in 68% of the older patients (56-65 years). Neurological complications occurred more frequently in the mechanical control group. CONCLUSIONS Reoperations for SVD after bioprosthesis implantation occurred exclusively among younger patients (<56 years), not suitable for systemic anticoagulation. Previous studies, together with our experience, are in favour of an age limit between 56 and 60 years, taking into consideration alternative transcatheter approaches to SVD treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tämän diplomityön tarkoituksena oli tutkia miten kuluttajien kierrättämästä polyeteenitereftalaatista ( PET ) voi valmistaa tyydyttymättömiä polyesterihartseja. Työssä valmistettiin yleiskäyttöön soveltuva laminointihartsi sekä 'gel coat' -hartsi jota käytetään esim. veneiden pintamaalina. Yleishartsin depolymerointiin käytettiin propyleeniglykolia ja 'gel coat' -hartsin valmistamiseen neopentyyliglykolia. Polykondensaatiovaiheessa reaktioon lisättiin maleiinihappoa ja lopuksi hartsit liuotettiin styreeniin. Kirjallisuusosassa esitetään eri menetelmiä PET:n depolymeroimiseksi. Lisäksi esitetään eri vaihtoehtoja glykolien, happojen, katalyyttien ja vinyylimonomeerien valitsemiseksi tyydyttymättömien polyesterihartsien valmistuksessa. Analyysimenetelmiä nestemäisten ja kovetettujen hartsien tutkimiseen ja vertailuun käydään läpi kuten myös erilaisia sovelluksia polyesterihartsien käyttämiseksi. Kokeellinen osa todisti että PET-pullojäte voidaan prosessoida hartsiksiilman uusia investointeja prosessilaitteistoon. PET:n glykolyysi kesti viidestäseitsemään tuntia ja polykondensaatiovaihe kahdesta ja puolesta viiteen tuntiin. Hartsien molekyylipainot ja mekaanisten testien tulokset olivat vertailukelpoisia kaupallisten hartsien antamien tulosten kanssa. Glykolyysivaiheen momomeeri- ja oligomeeripitoisuudet mitattiin geelipermeaatiokromatografialla, jotta nähtiin miten pitkälle depolymerisaatio oli edennyt. Tätä tietoa voidaan hyödyntää uusien hartsireseptin suunnittelussa. Polymeeriketjussa jäljellä olevien C=C kaksoissidosten määrä ja niiden isomeraatioaste maleaattimuodosta fumaraattimuotoon mitattiin 1H-NMR -menetelmällä. Tislevesien koostumus määritettiin kaasukromatografialla, ja tulokset kertoivat katalyytin sisältämän kloorin reagoineen glykolien kanssa, johtaen suureen glykolikulutukseen ja muihin ei-toivottuihin sivureaktioihin. Hartsien sietokykyä auringon valolle mitattiin niiden UV-absorption avulla. Kummastakin hartsista valmistettiin 'gel coat' -maalit jotkalaitettiin sääkoneeseen, joka simuloi auringonpaistetta ja vesisadetta vuorotellen. Näistä 'gel coateista' mitattiin niiden kellastumista. Kummastakin hartsista tehdyt valut asetettiin myös sääkoneeseen ja IR-spektreistä ennen jajälkeen koetta nähtiin että C=O ja C-O esterisidoksia oli hajonnut.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vesistöissä laivojen pintaan tarttuvat eliöt ovat sekä taloudellinen että kosmeettinen ongelma. Kontrolloimattoman eliöiden kiinnittymisen seurauksena aiheutuu kitkaa, joka puolestaan hidastaa laivan nopeutta ja aiheuttaa polttoaineen kulutuksen kasvua. Tavallisesti eliöiden kiinnittymistä ehkäistään kiinnittymisenestomaalien avulla. Niiden toiminta perustuu biosidien liukenemiseen, jolloin veden ja pinnoitteen väliselle rajapinnalle muodostuu korkea biosidipitoisuus, joka estää eliöiden kiinnittymistä pinnalle. Maailmanlaajuinen orgaanisten tinayhdisteiden käyttökielto kiinnittymisen-estomaaleissa tulee voimaan vuoden 2003 alusta. Tällä hetkellä 70 % maailman laivastoista on suojattu orgaanista tinayhdistettä sisältävällä kiinnittymisenestomaalilla. Nyt onkin kasvava tarve kehittää uusia ympäristöystävällisempiä kiinnittymisenesto-pinnoitteita. Todennäköisesti tinayhdisteet tullaan korvaamaan synteettisillä orgaanisilla yhdisteillä käytettyinä yhdessä kuparin kanssa. Työn tarkoituksena oli valmistaa ympäristöystävällisempi tyydyttämätön polyesteripinnoite, joka itsessään ehkäisisi eliöiden kiinnittymistä. Kirjallisuusosassa tutustuttiin markkinoilla oleviin biosideihin, niiden myrkyllisyyteen ja vaikutuksiin ympäristölle sekä muuttuvaan lainsäädäntöön. Työssä tarkasteltiin myös tällä hetkellä markkinoilla olevia pinnoitteita ja niiden toimintamekanismeja sekä myrkyttömiä vaihtoehtopinnoitteita kiinnittymisenestoon. Kokeellinen osa koostui kahdesta osasta. Ensimmäisessä osassa tutkittiin biosidien sopivuutta käytettäväksi yhdessä tyydyttymättömän polyesterin kanssa. Yhteensopivuutta määritettiin applikaatiotesteillä ja pinnoitteen käyttäytymisen perusteella. Toinen vaihe oli selvittää pinnoitteen tehokkuus leväntarttumista vastaan. Tyydyttymätön polyesteri gel coat kiinnittymisenesto-ominaisuuksilla valmistettiin dispergoimalla biosideja tyydyttymättömään polyesterigeeliin. Yhteensopivuustestien tulosten perusteella huomattiin, ettei biosidien lisääminen geeliin vaikuta mainittavasti applikaatio-ominaisuuksien huononemiseen. Brookfield viskositeetin stabiilisuus jopa paranee ja yksi työssä käytetyistä biosideista parantaa pinnoitteen säänkestoominaisuuksia. Tässä työssä ei pystytty määrittämään eri biosidien välisiä eroja tehokkuudessa levää vastaan.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new protocol is described for immunization of outbred Swiss mice. The procedure is based on subcutaneous implantation of antigen-coupled polyester-polyurethane sponges cut into disks of 10 mm in diameter vs 2 mm in thickness. Antigen coupling was performed by overnight incubation of the sponge with a solution of ovalbumin (Ova) (2 mg/ml) diluted in sodium carbonate buffer, pH 9.6. The amount of ovalbumin that was taken up by the sponge was between 71.4 to 82.5 µg. This was estimated by comparing the Ova absorbance at 280 nm in coating buffer solutions before and after incubation. To compare the efficiency of the proposed method, experimental groups immunized with the antigen in the presence of adjuvants (10 µg in Al(OH)3 or 100 µg in complete Freund's adjuvant (CFA)) were run in parallel. The data obtained after the 3rd week of immunization indicate that both cellular and humoral immune responses were achieved. These were assayed by antigen-induced footpad swelling and ELISA (specific antibodies), respectively. The levels of both immune responses elicited were similar to the responses observed in mice immunized with ovalbumin in the presence of Al(OH)3. The method might represent an advantage when immunizing with pathogenic antigens. Preliminary experiments have suggested that the antigen remains immobilized or bound to the sponge for a long period of time, since there is an increment on the cell population inside the sponges after boosting the animals. If so, the undesirable effects of immunization would be reduced.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Microscopic visualization, especially in transparent micromodels, can provide valuable information to understand the transport phenomena at pore scale in different process occurring in porous materials (food, timber, soils, etc.). Micromodels studies focus mainly on the observation of multi-phase flow, which presents a greater proximity to reality. The aim of this study was to study the process of flexography and its application in the manufacture of polyester resin transparent micromodels and its application to carrots. Materials used to implement a flexo station for micromodels construction were thermoregulated water bath, exposure chamber to UV light, photosensitive substance (photopolymer), RTV silicone polyester resin, and glass plates. In this paper, data on size distribution of a particular kind of carrot we used, and a transparent micromodel with square cross-section as well as a Log-normal pore size distribution with pore radii ranging from 10 to 110 µm (average of 22 µm and micromodel size of 10 × 10 cm) were built. Finally, it stresses that it has successfully implemented the protocol processing 2D polyester resin transparent micromodels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cure characteristics of short polyester fiber-polyurethane composites with respect to different bonding agents (MD resins) based on 4, 4' diphenylmethanediisocyanate (MDI) and various diols like propyleneglycol (PG), polypropyleneglycol (PPG) and glycerol (GL) were studied. Tmax. - Tmin. of composites having MD resin were found to be higher than the composite without MD resin. Minimum torque and Tmax. - Tmin., scorch time and optimum cure time were increased with the increase of MDI equivalence. Optimum ratio of MDI / -of in the resin was found to be within the range of 1-1.5. It was observed from the cure characteristics that for getting better adhesion between short polyester fiber and the polyurethane matrix the best choice of MD resin was one based on MDI and 1:1 equivalent mixture of polypropyleneglycol and glycerol.