56 resultados para patellofemoral
Resumo:
Objective. To assess the reliability of physical examination of the osteoarthritic (OA) knee by rheumatologists, and to evaluate the benefits of standardization. Methods. Forty-two physical signs and techniques were evaluated using a 6 X 6 Latin square design. Patients with mild to severe knee OA, based on physical and radiographic signs, were examined in random order prior to and following standardization of techniques. For those signs with dichotomous scales, agreement among the rheumatologists was calculated as the prevalence-adjusted bias-adjusted kappa (PABAK), while for the signs with continuous and ordinal scales, a reliability coefficient (R-c) was calculated using analysis of variance. A PABAK of >0.60 and an Re of >0.80 were considered to indicate adequate reliability. Results. Adequate poststandardization reliability was achieved for 30 of 42 physical signs/techniques (71%). The most highly reliable signs identified by physical examination of the OA knee included alignment by goniometer (R-c = 0.99), bony swelling (R-c = 0.97), general passive crepitus (R-c = 0.96), gait by inspection (PABAK = 0.78), effusion bulge sign (R-c = 0.97), quadriceps atrophy (R. = 0.97), medial tibiofemoral tenderness (R-c = 0.94), lateral tibiofemoral tenderness (R-c = 0.85), patellofemoral tenderness by grind test (R-c = 0.94), and flexion contracture (R-c = 0.95). The standardization process resulted in substantial improvements in reliability for evaluation of a number of physical signs, although for some signs, minimal or no effect of standardization was noted. After standardization, warmth (PABAK = 0.14), medial instability at 30degrees flexion (PABAK = 0.02), and lateral instability at 30degrees flexion (PABAK = 0.34) were the only 3 signs that were highly unreliable. Conclusion. With the exception of physical examinations for instability, a comprehensive knee examination can be performed with adequate reliability. Standardization further improves the reliability for some physical signs and techniques. The application of these findings to future OA studies will contribute to improved outcome assessments in OA.
Resumo:
Orthotic therapy is frequently advocated for the treatment Of musculoskeletal pain and injury of the lower limb. The clinical efficacy, mechanical effects, and Underlying mechanism of the action of foot orthotics has not been Conclusively determined making it difficult for practitioners to agree on a reliable and valid clinical approach to their application and indeed even their fabrication. This problem is compounded by evidence suggesting that the most commonly used approach for orthotic prescription, the (Biomechanical Evaluation of the Foot. Vol. 1. Clinical Biomechanics Corporation, Los Angeles, 1971) approach, has poor validity and many of the associated clinical measurements of that approach lack adequate levels of reliability. This paper proposes a new approach that is based on two key elements. One is the identification, verification and quantification of physical tasks that serve as client specific outcome measures. The second is the application of specific physical manipulations during the performance of these physical tasks. The physical manipulations are selected on the basis of motion dysfunction and their immediate effects on the client specific outcome measures serve as the basis to making an informed decision on the propriety of using orthotics in individual clients. The motion dysfunction also guides the type of orthotic that is applied. Practical case examples as well Lis generic and specific guidelines to the application of this clinical assessment process and orthotics are provided in this paper. (C) 2004 Published by Elsevier Ltd.
Resumo:
Anterior knee pain (AKP) is common and has been argued to be related to poor patellofemoral joint control due to impaired coordination of the vasti muscles. However, there are conflicting data. Changes in motor unit firing may provide more definitive evidence. Synchronization of motor unit action potentials (MUAPs) in vastus medialis obliquus (VMO) and vastus lateralis (VL) may contribute to coordination in patellofemoral joint control. We hypothesized that synchronization may be reduced in AKP. Recordings of single MUAPs were made from VMO and multiunit electromyograph (EMG) recordings were made from VL. Averages of VL EMG recordings were triggered from the single MUAPs in VMO. Motor units in VL firing in association with the VMO motor units would appear as a peak in the VL EMG average. Data were compared to previous normative data. The proportion of trials in which a peak was identified in the triggered averages of VL EMG was reduced in people with AKP (38%) compared to controls (90%). Notably, although 80% of subjects had values less than controls, 20% were within normal limits. These results provide new evidence that motor unit synchronization is modified in the presence of pain and provide evidence for motor control dysfunction in AKP. Perspective: This study shows that coordination of motor units between the medial and lateral vasti muscles in people with anterior knee pain is reduced compared to people without knee pain. It confirms that motor control dysfunction is a factor in this condition and has implications for selection of rehabilitation strategies. (c) 2005 by the American Pain Society.
Resumo:
Objective: Accurate neuromuscular control of the patellofemoral joint is important in knee joint mechanics. Strategies to coordinate the vasti muscles, such as motor unit synchronization, may simplify control of patellar tracking. This study investigated motor unit synchronization between vastus medialis (VM) and lateralis (VL). Methods: Electromyographic (EMG) recordings of single motor unit action potentials (MUAPs) were made from VM and single- and multi-unit recordings were made from VL. Synchronization was quantified from peaks in the cross-correlogram generated from single MUAP pairs in VL and VM. The proportion of motor units in VM with synchronized firing in VL was also quantified from peaks in averages of multiunit VL EMG triggered from the VM MUAP. Results: A high degree of synchronization of motor unit firing between VM and VL was identified. Results were similar for cross-correlation (similar to 45% of cases) and triggered averages (similar to 41% of cases). Conclusions: The data suggest that synchronization between VM and VL is higher than expected. Agreement between traditional cross-correlation and triggered averaging methods suggest that this new technique may provide a more clinically viable method to quantify synchronization. Significance: High synchronization between VM and VL may provide a solution to simplify control of the mechanically unstable patellofemoral joint. (c) 2005 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
Resumo:
Objectives: To investigate motor unit synchronization between medial and lateral vasti and whether such synchronization differs in closed and open chain tasks. Design: Electromyographic recordings of single motor unit action potentials were made from the vastus medialis obliquus (VMO) and multiunit recordings from vastus lateralis during isometric contractions at 30 degrees of knee flexion in closed and open chain conditions. Setting: Laboratory. Participants: Five volunteers with no history of knee pain (age, 30 +/- 3.32y). Interventions: Not applicable. Main Outcome Measure: The degree of synchronization between motor unit firing was evaluated by identifying peaks in the electromyographic averages of the vastus lateralis, triggered from motor unit action potentials in the VMO, and the proportion of power in the power spectral density of the triggered average at the firing frequency of the reference motor unit. The proportion of cases in which there was significant power and peaks in the triggered averages was calculated. Results: The proportion of trials with peaks in the triggered averages of the vastus lateralis electromyographic activity was greater than 61.5% in all tasks, and there was a significantly greater proportion of cases where power in the spectrum was greater than 7.5% (P = .01) for the closed chain condition. Conclusions: There was a high proportion of synchronized motor units between the 2 muscles during isometric contractions, with evidence for greater common drive between the VMO and vastus lateralis in closed chain tasks. This has implications for rehabilitation because it suggests that closed chain tasks may generate better coordination between the vasti muscles.
Resumo:
Activity of the vasti has been argued to vary through knee range of movement due to changes in passive support of the patellofemoral joint and the relative contribution of these muscles to knee extension. Efficient function of the knee is dependent on optimal control of the patellofemoral joint, largely through coordinated activity of the medial and lateral quadriceps. Motor unit synchronization may provide a mechanism to coordinate the activity of vastus medialis (VMO) and vastus lateralis (VL), and may be more critical in positions of reduced passive support for the patellofemoral joint (i.e., full extension). Therefore, the aim of this study was to determine whether the degree of motor unit synchronization between the vasti muscles is dependent on joint angle. Electromyographic (EMG) recordings of single motor unit action potentials (MUAPs) were made from VMO and multiunit recordings from VL during isometric contractions of the quadriceps at 0 degrees, 30 degrees, and 60 degrees of knee flexion. The degree of synchronization between motor unit firing was evaluated by identification of peaks in the rectified EMG averages of VL, triggered from MUA-Ps in VMO. The proportion of cases in which there was a significant peak in the triggered averages was calculated. There was no significant difference in the degree of synchronization between the vasti at different knee angles (p = 0.57). These data suggest that this basic coordinative mechanism between the vasti muscles is controlled consistently throughout knee range of motion, and is not augmented at specific angles where the requirement for dynamic control of stability is increased. (D 2006 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Resumo:
Total knee arthroplasty (TKA) has revolutionized the life of millions of patients and it is the most efficient treatment in cases of osteoarthritis. The increase in life expectancy has lowered the average age of the patient, which requires a more enduring and performing prosthesis. To improve the design of implants and satisfying the patient's needs, a deep understanding of the knee Biomechanics is needed. To overcome the uncertainties of numerical models, recently instrumented knee prostheses are spreading. The aim of the thesis was to design and manifacture a new prototype of instrumented implant, able to measure kinetics and kinematics (in terms of medial and lateral forces and patellofemoral forces) of different interchangeable designs of prosthesis during experiments tests within a research laboratory, on robotic knee simulator. Unlike previous prototypes it was not aimed for industrial applications, but purely focusing on research. After a careful study of the literature, and a preliminary analytic study, the device was created modifying the structure of a commercial prosthesis and transforming it in a load cell. For monitoring the kinematics of the femoral component a three-layers, piezoelettric position sensor was manifactured using a Velostat foil. This sensor has responded well to pilot test. Once completed, such device can be used to validate existing numerical models of the knee and of TKA and create new ones, more accurate.It can lead to refinement of surgical techniques, to enhancement of prosthetic designs and, once validated, and if properly modified, it can be used also intraoperatively.
Resumo:
FEHR, Guilherme Lotierso et al. Efetividade dos exercícios em cadeia cinética aberta e cadeia cinética fechada no tratamento da síndrome da dor femoropatelar. Revista Brasileira de Medicina do Esporte, [s.l], v. 12, n. 2, p.66-70, mar./abr. 2006. Bimestral. Disponível em:
Resumo:
FEHR, Guilherme Lotierso et al. Efetividade dos exercícios em cadeia cinética aberta e cadeia cinética fechada no tratamento da síndrome da dor femoropatelar. Revista Brasileira de Medicina do Esporte, [s.l], v. 12, n. 2, p.66-70, mar./abr. 2006. Bimestral. Disponível em:
Resumo:
Dynamic knee valgus is a multi-planar motion that has been associated with anterior cruciate ligament injuries and patellofemoral pain syndrome. Clinical assessment of dynamic knee valgus can be made by looking for the visual appearance of excessive medial knee displacement (MKD) in the double-leg squat (DLS). The purpose of this dissertation was to identify the movement patterns and neuromuscular strategies associated with MKD during the DLS. Twenty-four control subjects and eight individuals showing MKD during the DLS participated in the study. Significant differences were verified between subjects that demonstrated MKD and a control (CON) group for the eletromyographic amplitude of adductor magnus, biceps femoris, vastus lateralis and vastus medialis muscles (p < 0.05), during the descending phase of the DLS. During the ascending phase were found group differences for adductor magnus and rectus femoris muscles (p < 0.05). Results from kinematic analysis revealed higher minimum and maximum values of ankle abduction and knee internal rotation angles (p < 0.05) for the MKD group. Also, individuals showing excessive MKD had higher hip adduction/abduction excursion. Our results suggested that higher tibial internal rotation and knee internal rotation angles in the initial position of the DLS are associated with MKD. The neuromuscular strategies that contributed to MKD were higher adductor magnus activation, whereas biceps femoris, vastus lateralis and vastus medialis activated more to stabilize the knee in response to the internal rotation moment.