944 resultados para organic electronics semiconductors detectors sensors X-rays


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We describe experiments designed to produce a bright M-L band x-ray source in the 3-3.5 keV region. Palladium targets irradiated with a 10(15) W cm(-2) laser pulse have previously been shown to convert up to similar to 2% of the laser energy into M-L band x-rays with similar pulse duration to that of the incident laser. This x-ray emission is further characterized here, including pulse duration and source size measurements, and a higher conversion efficiency than previously achieved is demonstrated (similar to 4%) using more energetic and longer duration laser pulses (200 ps). The emission near the aluminium K-edge (1.465-1.550 keV) is also reported for similar conditions, along with the successful suppression of such lower band x-rays using a CH coating on the rear side of the target. The possibility of using the source to radiatively heat a thin aluminium foil sample to uniform warm dense matter conditions is discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nationwide surveys on radiation dose to the population from medical radiology are recommended in order to follow the trends in population exposure and ensure radiation protection. The last survey in Switzerland was conducted in 1998, and the annual effective dose from medical radiology was estimated to be 1 mSv y(-1) per capita. The purpose of this work was to follow the trends in diagnostic radiology between 1998 and 2008 in Switzerland and determine the contribution of different modalities and types of examinations to the collective effective dose from medical x-rays. For this reason, an online database (www.raddose.ch) was developed. All healthcare providers who hold a license to run an x-ray unit in the country were invited to participate in the survey. More than 225 examinations, covering eight radiological modalities, were included in the survey. The average effective dose for each examination was reassessed. Data from about 3,500 users were collected (42% response rate). The survey showed that the annual effective dose was 1.2 mSv/capita in 2008. The most frequent examinations are conventional and dental radiographies (88%). The contribution of computed tomography was only 6% in terms of examination frequency but 68% in terms of effective dose. The comparison with other countries showed that the effective dose per capita in Switzerland was in the same range as in other countries with similar healthcare systems, although the annual number of examinations performed in Switzerland was higher.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Using a relativistic selfconsistent correlation diagram a first interpretation of the shape and position of L MO X-rays is given within a quasi-adiabatic model.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The result of the first calculation of a self-consistent relativistic many electron correlation diagram ever done (for the system Au - I) leads to a good agreement of the spectral shape and position of the observed noncharacteristic X-rays within the quasi adiabatic model.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

For the angular dependence of quasimolecular X-ray emission in heavy ion colliding systems we present a semiclassical adiabatic model taking into account spontaneous dipole radiation. Using the most characteristic levels from a DFS-correlation diagram we are able to explain the behaviour of the observed anisotropy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Quasi-molecular X-rays observed in heavy ion collisions are interpreted within a relativistic calculation of correlation diagrams using the Dirac-Slater model. A semiquantitative description of noncharacteristic M X rays is given for the system Au-I.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Platinum is one of the most common coatings used to optimize mirror reflectivity in soft X-ray beamlines. Normal operation results in optics contamination by carbon-based molecules present in the residual vacuum of the beamlines. The reflectivity reduction induced by a carbon layer at the mirror surface is a major problem in synchrotron radiation sources. A time-dependent photoelectron spectroscopy study of the chemical reactions which take place at the Pt(111) surface under operating conditions is presented. It is shown that the carbon contamination layer growth can be stopped and reversed by low partial pressures of oxygen for optics operated in intense photon beams at liquidnitrogen temperature. For mirrors operated at room temperature the carbon contamination observed for equivalent partial pressures of CO is reduced and the effects of oxygen are observed on a long time scale.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: The aim of this study was to evaluate the genotoxic effects of X-rays on epithelial gingival cells during panoramic dental radiography using a differentiated protocol for the micronucleus test. Methods: 40 healthy individuals who underwent this procedure for diagnostic purposes on request from their dentists agreed to participate in this study. All of them answered a questionnaire before the examination. Epithelial gingival cells were obtained from the keratinized mucosa of the upper dental arcade by gentle scraping with a cervical brush immediately before exposure and 10 days later. Cytological preparations were stained according to the Feulgen-Rossenbeck reaction, counterstained with fast green 1% for 1 min and analysed under a light microscope. Micronuclei, nuclear projections (broken eggs) and degenerative nuclear alterations (pyknosis, karyolysis, karyorrhexis and condensed chromatin) were scored. Results: The frequency of micronuclei was significantly higher after exposure (P < 0.05), as were frequencies of nuclear alterations indicate of apoptosis (P < 0.001). Conclusions: These results indicate that X-ray radiation emitted during panoramic dental radiography induces a genotoxic effect on epithelial gingival cells that increases the frequency of chromosomal damage and nuclear alterations indicative of apoptosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

X-ray irradiation is shown to affect electronic properties of polyaniline (PANi) in composite Langmuir-Blodgett (LB) films of PANi and cadmium stearate, in a similar way to acid doping. The time it takes for the shift in the UV-vis spectra, characteristic of PANi doping, increases linearly with the film thickness, thus indicating a surface-controlled process. The humidity of the environment under which the films are irradiated is also of extreme importance. No shin is observed under vacuum or under dry atmospheres of N-2, O-2 and Ar. For humid environments the time for the shift decreases with increasing relative humidity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As a contribution towards detecting the genetic effects of low doses of genotoxic physical agents, this paper deals with the consequences of low-dose X-rays in the Aspergillus nidulans genome. The irradiation doses studied were those commonly used in dental clinics (1-5 cGy). Even very low doses promoted increased mitotic crossing-over frequencies in diploid strains heterozygous for several genetic markers including the ones involved in DNA repair and recombination mechanisms. Genetic markers of several heterozygous strains were individually analyzed disclosing that some markers were especially sensitive to the treatments. These markers should be chosen as bio-indicators in the homozygotization index assay to better detect the recombinogenic/ carcinogenic genomic effects of low-dose X-rays. ©FUNPEC-RP.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A microcontrolled instrument for measuring the energy fluence rate (or intensity) of X-ray pulses in the orthovoltage range of 120 to 300 kV is described. The prototype instrument consists of a pyroelectric sensor, a low-noise highsensitivity current-to-voltage converter, a microcontroller and a digital display. The response of the instrument is nonlinear with the intensity of the radiation. The precision is better than 3%. The equipment is inexpensive, rugged, simple to construct and has good long-term stability. © 2009 Springer-Verlag.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Duchenne muscular dystrophy is a lethal genetic disease characterized by progressive muscle degeneration that usually had been used the Golden Retriever as a model for studying the disease (GRMD - Golden Retriever Muscular Dystrophy). A total of 16 male dystrophic Golden Retrievers dogs between 5 to 51 months of age were examined in the present study. The animals were classified as dystrophic according to two simultaneous complementary criteria: genotypic analysis and serum creatine kinase levels. The macroscopic abnormalities of the different organs and tissues and histopathological features were described using hematoxylin-eosin. The lesions in the skeletal muscles associated with the digestive problems resulted in cachexia with different intensities in all the dystrophic dogs. Cardiac muscle involvement was found in 87,5% of the GRMD dogs resulting, however, in cardiac failure in only 18,8% of the animals. The musculature of the diaphragm was hypertrophic in all affected animals resulting in progressive respiratory muscle weakness and at later stages in respiratory failure (81,25%). The liver abnormalities found in dystrophic dogs were originated mainly from heart disease and developed progressively. Hyperemia of mucosa and granular material indicated changes in the functioning and emptying of bladder. The germinative lineage cells presented moderate to severe degeneration probably due to degeneration of the scrotum and cremaster muscle which prevented the proper thermo-regulation of the testicle. Our results highlight the fact that there is significant impairment of the cardiac, respiratory and skeletal muscle systems in GRMD dogs since the age of five months. In addition, significant alterations of the gastrointestinal tract, urinary and reproductive systems are indicating the presence of degenerative lesions in the smooth musculature.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The extrapolation chamber is a parallel-plate ionization chamber that allows variation of its air-cavity volume. In this work, an experimental study and MCNP-4C Monte Carlo code simulations of an ionization chamber designed and constructed at the Calibration Laboratory at IFEN to be used as a secondary dosimetry standard for low-energy X-rays are reported. The results obtained were within the international recommendations, and the simulations showed that the components of the extrapolation chamber may influence its response up to 11.0%. (C) 2011 Elsevier Ltd. All rights reserved.