814 resultados para newborn screening


Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: In May 2003, a newborn auditory screening program was initiated in the Upper Palatinate. METHODS: Sequential OAE- and BERA-screening was conducted in all hospitals with obstetric facilities. The Screening Center at the Public Health Authority was responsible for the coordination of the screening process, completeness of participation, the follow-up of all subjects with a positive screening test and the quality of instrumental screening. RESULTS: A total of 96% of 17,469 newborns were screened. The referral rate at discharge was 1.6% (0.4% for bilateral positive findings). For 97% of the positive screening results, a definite diagnosis to confirm or exclude hearing loss was achieved; for 43% only after intervention by the Screening Center. Fifteen children with profound bilateral hearing impairment were identified of whom eight were only detected by the intervention of the Screening Center. CONCLUSION: The effective structures established in the Upper Palatinate provide a standard for the quality of neonatal auditory screening achievable in Germany.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Shipping list no.: 99-0282-P.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

"This publication was supported in part by Grant/Cooperative Agreement Number U50/CCU523303-04 from the U.S. Centers for Disease Control and Prevention. ... "--p. ii.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

"This publication was supported in part by Grant/Cooperative Agreement US50/CCU523303-04 and Early Hearing Detection and Intervention Award UR#CC1520048 from the U.S. Centers for Disease Control and Prevention. ..."--Leaf ii.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: Introducing neonatal screening procedures may not be readily accepted by parents and may increase anxiety. The acceptability of pulse oximetry screening to parents has not been previously reported. Objective: To assess maternal acceptability of pulse oximetry screening for congenital heart defects and to identify factors predictive of participation in screening. Design and setting: A questionnaire was completed by a cross-sectional sample of mothers whose babies were recruited into the PulseOx Study which investigated the test accuracy of pulse oximetry screening. Participants: A total of 119 mothers of babies with false-positive (FP) results, 15 with true-positive and 679 with true-negative results following screening. Main outcome measures: Questionnaires included measures of satisfaction with screening, anxiety, depression and perceptions of test results. Results: Participants were predominantly satisfied with screening. The anxiety of mothers given FP results was not significantly higher than that of mothers given true-negative results (median score 32.7 vs 30.0, p=0.09). White British/Irish mothers were more likely to participate in screening, with a decline rate of 5%; other ethnic groups were more likely to decline with the largest increase in declining being for Black African mothers (21%, OR 4.6, 95% CI 3.8 to 5.5). White British mothers were also less anxious (p<0.001) and more satisfied (p<0.001) than those of other ethnicities Conclusions: Pulse oximetry screening was acceptable to mothers and FP results were not found to increase anxiety. Factors leading to differences in participation and satisfaction across ethnic groups need to be identified so that staff can support parents appropriately.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: Screening for congenital heart defects (CHDs) relies on antenatal ultrasound and postnatal clinical examination; however, life-threatening defects often go undetected. Objective: To determine the accuracy, acceptability and cost-effectiveness of pulse oximetry as a screening test for CHDs in newborn infants. Design: A test accuracy study determined the accuracy of pulse oximetry. Acceptability of testing to parents was evaluated through a questionnaire, and to staff through focus groups. A decision-analytic model was constructed to assess cost-effectiveness. Setting: Six UK maternity units. Participants: These were 20,055 asymptomatic newborns at = 35 weeks’ gestation, their mothers and health-care staff. Interventions: Pulse oximetry was performed prior to discharge from hospital and the results of this index test were compared with a composite reference standard (echocardiography, clinical follow-up and follow-up through interrogation of clinical databases). Main outcome measures: Detection of major CHDs – defined as causing death or requiring invasive intervention up to 12 months of age (subdivided into critical CHDs causing death or intervention before 28 days, and serious CHDs causing death or intervention between 1 and 12 months of age); acceptability of testing to parents and staff; and the cost-effectiveness in terms of cost per timely diagnosis. Results: Fifty-three of the 20,055 babies screened had a major CHD (24 critical and 29 serious), a prevalence of 2.6 per 1000 live births. Pulse oximetry had a sensitivity of 75.0% [95% confidence interval (CI) 53.3% to 90.2%] for critical cases and 49.1% (95% CI 35.1% to 63.2%) for all major CHDs. When 23 cases were excluded, in which a CHD was already suspected following antenatal ultrasound, pulse oximetry had a sensitivity of 58.3% (95% CI 27.7% to 84.8%) for critical cases (12 babies) and 28.6% (95% CI 14.6% to 46.3%) for all major CHDs (35 babies). False-positive (FP) results occurred in 1 in 119 babies (0.84%) without major CHDs (specificity 99.2%, 95% CI 99.0% to 99.3%). However, of the 169 FPs, there were six cases of significant but not major CHDs and 40 cases of respiratory or infective illness requiring medical intervention. The prevalence of major CHDs in babies with normal pulse oximetry was 1.4 (95% CI 0.9 to 2.0) per 1000 live births, as 27 babies with major CHDs (6 critical and 21 serious) were missed. Parent and staff participants were predominantly satisfied with screening, perceiving it as an important test to detect ill babies. There was no evidence that mothers given FP results were more anxious after participating than those given true-negative results, although they were less satisfied with the test. White British/Irish mothers were more likely to participate in the study, and were less anxious and more satisfied than those of other ethnicities. The incremental cost-effectiveness ratio of pulse oximetry plus clinical examination compared with examination alone is approximately £24,900 per timely diagnosis in a population in which antenatal screening for CHDs already exists. Conclusions: Pulse oximetry is a simple, safe, feasible test that is acceptable to parents and staff and adds value to existing screening. It is likely to identify cases of critical CHDs that would otherwise go undetected. It is also likely to be cost-effective given current acceptable thresholds. The detection of other pathologies, such as significant CHDs and respiratory and infective illnesses, is an additional advantage. Other pulse oximetry techniques, such as perfusion index, may enhance detection of aortic obstructive lesions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Two groups of patients with cystic fibrosis were compared. The screened group, detected with an improved neonatal screening assay for immunoreactive trypsin, developed fewer chest infections requiring treatment and gained more weight than the unscreened group. Early diagnosis by screening seems to affect early morbidity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Glucose-6-phosphate dehydrogenase (G6PD) deficiency is seen at a higher frequency in many national and ethnic groups in areas of current or former malaria endemicity. A screening programme undertaken to evaluate the gene frequencies for this deficiency in the highly inbred South Indian population of Karnataka revealed that of the 5140 neonates screened, 7.8% were G6PD deficient with no correlation between the reported level of inbreeding and enzyme deficiency. An interesting finding was the equal number of male (198) and female (207) individuals, with G6PD activity of less than 3 IU. The possible implications of this finding with regard to the expression of G6PD gene is discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Early diagnosis of hearing loss minimizes its impact on child development. We studied factors that influence the effectiveness of screening programs. To investigate the relationship between gender, weight at birth, gestational age, risk factors for hearing loss, venue for newborn hearing screening and pass and fail results in the retest. Prospective cohort study was carried out in a tertiary referral hospital. The screening was performed in 565 newborns through transient evoked otoacoustic emissions in three admission units before hospital discharge and retest in the outpatient clinic. Gender, weight at birth, gestational age, presence of risk indicators for hearing loss and venue for newborn hearing screening were considered. Full-term infants comprised 86% of the cases, preterm 14%, and risk factors for hearing loss were identified in 11%. Considering the 165 newborns retested, only the venue for screening, Intermediate Care Unit, was related to fail result in the retest. Gender, weight at birth, gestational age and presence of risk factors for hearing loss were not related to pass and/or fail results in the retest. The screening performed in intermediate care units increases the chance of continued fail result in the Transient Otoacoustic Evoked Emissions test.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a 3 day old girl born at term presenting with an interlabial, cystic mass. Pregnancy, delivery and routine antenatal screening were unremarkable. The smooth lesion was located in the anterior half of the vulva, covered with thin vessels. The medially displaced urethra and the medio-posteriorly displaced hymen were identified. Voiding was not impaired. We discuss the differential diagnosis of vulvar masses in the newborn girl. A thorough clinical examination must be the standard of care of pediatric examinations in infants.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective. Although complete blood count (CBC) changes occur with the development of clinical sepsis in newborns, the CBC has not been reported to be a sensitive predictor of sepsis in asymptomatic full-term newborn infants, nor has it been reported to be related to risk factors for sepsis or clinical decisions. The objective of this study was to evaluate the relationship between the WBC/I:T (immature:total neutrophil) ratio and maternal group B streptococcal (GBS) risk factors (rupture of membranes ≥18 hours, maternal temperature ≥100.4°F, maternal age ≤20 years, previous infant with invasive GBS disease, maternal GBS bacteriuria, and black ethnicity); and to evaluate the relationship between the WBC/I:T ratios and providers' clinical decisions (observe versus repeat the CBC or complete sepsis evaluation) in the asymptomatic full-term newborn at risk for early-onset GBS sepsis. ^ Methods. Medical records of infants admitted to the well baby nursery at a tertiary care teaching hospital in Houston, TX between 1/1/99 and 12/31/00 whose gestational ages were ≥35 weeks; who had mothers with GBS positive or unknown culture status and inadequate intrapartum antibiotic prophylaxis; and who had screening CBCs performed in the first 30 hours of life because of GBS risk were reviewed (n = 412). Demographic information, maternal GBS risk factors, CBC results, clinical decisions, and rationales for clinical decisions were collected. ^ Results. With the exception of black ethnicity (p = .0000, odds ratio = 0.213), no statistically significant differences in risk factors between infants with normal and abnormal WBC counts or normal and abnormal I:T ratios were found. Infants with abnormal WBCs had a significantly higher likelihood of having a CBC repeated (p = 0.002 for WBC). Providers documented the CBC result in the rationale for clinical decisions in 62% of the cases. ^ Conclusion. The CBC results were not related to maternal risk factors for GBS except for ethnicity. Black infants had significantly lower WBC levels than infants of other ethnicities, although this difference was clinically insignificant. Infants with abnormal WBCs had a significantly higher likelihood of undergoing repeat CBCs but not sepsis evaluations. Provider rationale was difficult to evaluate due to insufficient documentation. The screening CBC result did not impact the clinicians' decisions to initiate sepsis evaluations in this population. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Incidence of jaundice is high in newborn infants. Since well appearing newborns are rapidly and routinely discharged from hospital, performing an inexpensive noninvasive pre-discharge screening test for evaluation of jaundice seems to be necessary. Objectives: This study was conducted to compare the accuracy of cutaneous v/s serum bilirubin measurements in this regard. Patients and Methods: This was a prospective cross sectional study conducted in Mahdieh hospital, Tehran. 613 neonates weighing ≥ 1,800 g with gestational age of ≥ 35 weeks were enrolled. A pre discharge transcutaneous bilirubin test (TcB) was performed in all. Serum samples were taken from neonates with TcB ≥ 5 mg/dL in first and > 8 mg/dL in second 24 hours. Decision for treatment or recheck of bilirubin level after discharge was made based on serum bilirubin results. Results: Based on the study protocol, among 613 studied neonates, 491 (80%) revealed high TcB, of them 240 (49%) cases showed TBC ≥ 5 mg/dL in first and 251 (51 %) in second pre-discharge 24 hours. TcB ranged 3.3 - 17.1, mean TcB in first 24 hours was 6.9 ± 1 .7 (mode 6) and in second 24 hours 9.1 ± 2.1 (mode 10). Of 491 neonates with high TcB, capillary serum sample was taken as the second step and 398 neonates revealed high total serum bilirubin (TsB) with the same protocol for TcB. 108 (27.1%) neonates showed TsB ≥ 5 mg/dL in first and 290 (72.9%) in second 24 hours. According to the study results TcB has a 81% positive predictive value (PPV) in diagnosis of hyperbilirubinemia. Correlation coefficient of TcB and TsB in highest rate is equal to 72% (P value < 0.001). Conclusions: TcB is an inexpensive, noninvasive and precise pre-discharge screening test for evaluation of hyperbilirubinemia, with a high PPV. It is highly recommended to be performed routinely due to high incidence of hyperbilirubinemia in neonates.