877 resultados para new method
Resumo:
Under the multipath conditions of terrestrial television transmission, ghost carriers cause additive information to be generated by the VSB filter within the television receiver. By analysis of this a priori effect of the VSB filter under a ghosted condition the inphase and phase quadrature detected video signals are defined. Derived from these results, a new algorithm based upon correlation techniques is presented which finds the characteristics of the amplitude and delay of individual ghosts. These characteristics are then passed to a deterministic deghoster to minimise ghost effects.
Resumo:
It has been found that hydrogels may be formed by microwave irradiation of aqueous solutions containing appropriate combinations of polymers. This new method of hydrogel synthesis yields sterile hydrogels without the use of monomers, eliminating the need for the removal of unreacted species from the final product. Results for two particularly successful combinations, poly(vinyl alcohol) with either poly(acrylic acid) or poly(methylvinylether-alt-maleic anhydride), are presented. Irradiation using temperatures of 100–150 °C was found to yield hydrogels with large equilibrium swelling degrees of 500–1000 g g−1. Material leached from both types of hydrogel shows little cytotoxicity towards HT29 cells.
Resumo:
This paper describes a new method for the assessment of palaeohydrology through the Holocene. A palaeoclimate model was linked with a hydrological model, using a weather generator to correct bias in the rainfall estimates, to simulate the changes in the flood frequency and the groundwater response through the late Pleistocene and Holocene for the Wadi Faynan in southern Jordan, a site considered internationally important due to its rich archaeological heritage spanning the Pleistocene and Holocene. This is the first study to describe the hydrological functioning of the Wadi Faynan, a meso-scale (241 km2) semi-arid catchment, setting this description within the framework of contemporary archaeological investigations. Historic meteorological records were collated and supplemented with new hydrological and water quality data. The modelled outcomes indicate that environmental changes, such as deforestation, had a major impact on the local water cycle and this amplified the effect of the prevailing climate on the flow regime. The results also show that increased rainfall alone does not necessarily imply better conditions for farming and highlight the importance of groundwater. The discussion focuses on the utility of the method and the importance of the local hydrology to the sustained settlement of the Wadi Faynan through pre-history and history.
Resumo:
The use of kilometre-scale ensembles in operational forecasting provides new challenges for forecast interpretation and evaluation to account for uncertainty on the convective scale. A new neighbourhood based method is presented for evaluating and characterising the local predictability variations from convective scale ensembles. Spatial scales over which ensemble forecasts agree (agreement scales, S^A) are calculated at each grid point ij, providing a map of the spatial agreement between forecasts. By comparing the average agreement scale obtained from ensemble member pairs (S^A(mm)_ij), with that between members and radar observations (S^A(mo)_ij), this approach allows the location-dependent spatial spread-skill relationship of the ensemble to be assessed. The properties of the agreement scales are demonstrated using an idealised experiment. To demonstrate the methods in an operational context the S^A(mm)_ij and S^A(mo)_ij are calculated for six convective cases run with the Met Office UK Ensemble Prediction System. The S^A(mm)_ij highlight predictability differences between cases, which can be linked to physical processes. Maps of S^A(mm)_ij are found to summarise the spatial predictability in a compact and physically meaningful manner that is useful for forecasting and for model interpretation. Comparison of S^A(mm)_ij and S^A(mo)_ij demonstrates the case-by-case and temporal variability of the spatial spread-skill, which can again be linked to physical processes.
Resumo:
A new method is presented to prepare anatomical slides of plant materials including a combination of soft and hard tissues, such as stems with cambial variants, arboreal monocotyledons, and tree bark The method integrates previous techniques aimed at softening the samples and making them thereby more homogeneous, with the use of anti-tearing polystyrene foam solution In addition, we suggest two other alternatives to protect the sections from tearing adhesive tape and/or Mayer`s albumin adhesive, both combined with the polystyrene foam solution This solution is cheap and easy to make by dissolving any packaging polystyrene m butyl acetate It is applied before each section is cut on a sliding microtome and ensures that all the tissues in the section will hold together This novel microtechnical procedure will facilitate the study of heterogeneous plant portions, as shown in some illustrated examples
Resumo:
An ultra-fast and improved analytical methodology based on microextraction by packed sorbent (MEPS) combined with ultra-performance LC (UPLC) was developed and validated for determination of (E)-resveratrol in wines. Important factors affecting the performance of MEPS such as the type of sorbent material (C2, C8, C18, SIL, and M1), number of extraction cycles, and sample volume were studied. The optimal conditions of MEPS extraction were obtained using C8 sorbent and small sample volumes (50–250mL) in one extraction cycle (extract–discard) and in a short time period (about 3 min for the entire sample preparation step). (E)-Resveratrol was eluted by 1 250mL of the mixture containing 95% methanol and 5% water, and the separation was carried out on a highstrength silica HSS T3 analytical column (100 mm 2.1 mm, 1.8mm particle size) using a binary mobile phase composed of aqueous 0.1% formic acid (eluent A) and methanol (eluent B) in the gradient elution mode (10 min of total analysis). The method was fully validated in terms of linearity, detection (LOD) and quantification (LOQ) limits, extraction yield, accuracy, and inter/intra-day precision, using a Madeira wine sample (ET) spiked with (E)-resveratrol at concentration levels ranging from 5 to 60mg/mL. Validation experiments revealed very good recovery rate of 9575.8% RSD, good linearity with r2 values 40.999 within the established concentration range, excellent repeatability (0.52%), and reproducibility (1.67%) values (expressed as RSD), thus demonstrating the robustness and accuracy of the MEPSC8/UPLC-photodiode array (PDA) method. The LOD of the method was 0.21mg/mL, whereas the LOQ was 0.68mg/mL. The validated methodology was applied to 30 commercial wines (24 red wines and six white wines) from different grape varieties, vintages, and regions. On the basis of the analytical validation, the MEPSC8/UPLC-PDA methodology shows to be an improved, sensitive, and ultra-fast approach for determination of (E)-resveratrol in wines with high resolving power within 6 min.
Resumo:
Citrus black spot (CBS) is a fungal disease, caused by Guignardia citricarpa, that has a high economic impact on citrus. Although G. citricarpa has been associated with black spot of citrus, an adequate pathogenicity test is still not available. Thus, our objective was to develop and evaluate a simple, safe, and practical pathogenicity test. We used fruits from Pera-Rio and Valencia sweet orange trees from two different orchards, located in the State of São Paulo, Brazil. Inoculation was performed by placing six disks colonized by G. citricarpa, onto the peel of healthy fruits, previously bagged. In the Pera-Rio sweet orange grove, initial symptoms of the false melanose type resulting from the inoculations were observed 55 days after inoculation (dai). In the Valencia grove, initial symptoms also of the false melanose type resulting from the inoculations occurred 73 dai. A total of 92.8% and 86.6% of the Pera Rio and Valencia fruits inoculated, respectively, showed symptoms of CBS. Citrus black spot symptoms were not observed in any of the control fruits.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
A new method for real time computation of power quality indices based on instantaneous space phasors
Resumo:
One of the important issues about using renewable energy is the integration of dispersed generation in the distribution networks. Previous experience has shown that the integration of dispersed generation can improve voltage profile in the network, decrease loss, etc. but can create safety and technical problems as well. This work report the application of the instantaneous space phasors and the instantaneous complex power in observing performances of the distribution networks with dispersed generators in steady state. New IEEE apparent power definition, the so-called Buchholz-Goodhue effective apparent power, as well as new proposed power quality (oscillation) index in the three-phase distribution systems with unbalanced loads and dispersed generators, are applied. Results obtained from several case studies using IEEE 34 nodes test network are presented and discussed. (C) 2006 Elsevier B.V. All rights reserved.
Resumo:
A new method is described for the rapid, sensitive, virtually interference-free, and selective quantitation of cyanogenic glycosides in aqueous extracts using membrane introduction mass spectrometry (MIMS). Selective monitoring, by either conventional MIMS or cryotrap-MIMS, not of HCN but of the co-released ketones (acetone and butan-2-one), when performed for both the crude cassava extracts and the linamarase-NaOH-hydrolyzed extracts, is found to offer an advantageous alternative to classic spectrophotometric methods based on HCN analysis for the selective quantitation of the two cyanogenic glycosides linamarin and lotaustralin expressed as both the free HCN content and the total cyanogenic potential (total HCN).
Resumo:
This paper describes a technique for extending the force range of thin conductive polymer force sensors used for measuring contact force. These sensors are conventionally used for measuring force by changing electrical resistance when they are compressed. The new method involves measuring change in electrical resistance when the flexible sensor, which is sensitive to both compression and bending, is sandwiched between two layers of spring steel, and the structure is supported on a thin metal ring. When external force is applied, the stiffened sensor inside the spring steel is deformed within the annular center of the ring, causing the sensor to bend in proportion to the applied force. This method effectively increases the usable force range, while adding little in the way of thickness and weight. Average error for loads between 10 N and 100 N was 2.2 N (SD = 1.7) for a conventional conductive polymer sensor, and 0.9 N (SD = 0.4) using the new approach. Although this method permits measurement of greater loads with an error less than 1 N, it is limited since the modified sensor is insensitive to loads less than 5 N. These modified sensors are nevertheless useful for directly measuring normal force applied against handles and tools and other situations involving forceful manual work activities, such as grasp, push, pull, or press that could not otherwise be measured in actual work situations.