980 resultados para needle injection methods
Resumo:
In this paper, a protection scheme for transmitters in wavelength-division-multiplexing passive optical network (WDM-PON) has been proposed and demonstrated. If any downstream transmitter encounters problems at the central office (CO), the interrupted communication can be restored immediately by injecting a Fabry-Perot laser diode (FP-LD) with the upstream lightwave corresponding to the failure transmitter. Compared with the conventional methods, this proposed architecture provides a cost-effective and reliable protection scheme employing a common FP-LD. In the experiment, a 1 36 protection capability was implemented with a 2.5 Gbit/s downstream transmission capability. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
After capping InAs islands with a thin enough GaAs layer, growth interruption has been introduced. Ejected energy of self-organized InAs/GaAs quantum dots has been successfully tuned in a controlled manner by changing the thickness of GaAs capping layer and the time of growth interruption and InAs layer thickness. The photoluminescence (PL) spectra showing the shift of the peak position reveals the tuning of the electronic states of the QD system. Enhanced uniformity of Quantum dots is observed judging from the decrease of full width at half maximum of FL. Injection InAs/GaAs quantum dot lasers have been fabricated and performed on various frequencies. (C) 2000 Published by Elsevier Science B.V. All rights reserved.
Resumo:
After capping InAs islands with a thin enough GaAs layer, growth interruption has been introduced. Ejected energy of self-organized InAs/GaAs quantum dots has been successfully tuned in a controlled manner by changing the thickness of GaAs capping layer and the time of growth interruption and InAs layer thickness. The photoluminescence (PL) spectra showing the shift of the peak position reveals the tuning of the electronic states of the QD system. Enhanced uniformity of Quantum dots is observed judging from the decrease of full width at half maximum of FL. Injection InAs/GaAs quantum dot lasers have been fabricated and performed on various frequencies. (C) 2000 Published by Elsevier Science B.V. All rights reserved.
Resumo:
IEECAS SKLLQG
Resumo:
The effect of adding internal fins to the injection tube of a storage cell target filled with a polarized atomic beam source has been studied. The tube conductance and the atomic beam intensity at the exit of the injection tube have been measured, observing an unexpectedly large beam loss. Simulations of the atomic beam reproduce the observed attenuation only when the non-zero azimuthal component of the atom's velocity is taken into account.
Resumo:
To meet the requirements of providing high-intensity heavy ion beams the direct plasma injection scheme (DPIS) was proposed by a RIKEN-CNS-TIT collaboration. In this scheme a radio frequency quadrupole (RFQ) was joined directly with the laser ion source (LIS) without a low-energy beam transport (LEBT) line. To find the best design of the RFQ that will have short length, high transmission efficiency and small emittance growth, beam dynamics designs with equipartitioning design strategy and with matched-only design strategy have been performed, and a comparison of their results has also been done. Impacts of the input beam parameters on transmission efficiency are presented, too. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
A synchrotron is designed for tumour therapy with C6+ ions or proton. Its injector is a cyclotron, which delivers C5+ or H-2(+) ions to the synchrotron. After comparing the methods of the single-turn injection, the multi-turn injection and the stripping injection, this paper chooses the stripping injection method. In addition, the concept design of the injection system is presented, in which the synchrotron lattice is optimized.
Resumo:
With the target to design and develop new functionalized green triplet light emitters that possess distinctive electronic properties for robust and highly efficient phosphorescent organic light-emitting diodes (PHOLEDs), a series of bluish-green to yellow-green phosphorescent tris-cyclometalated homoleptic iridium(III) complexes [Ir(ppy-X)(3)] (X=SiPh3, GePh3, NPh2, POPh2, OPh, SPh, SO2Ph, Hppy=2-phenylpyridine) have been synthesized and fully characterized by spectroscopic, redox, and photophysical methods
Resumo:
Quantum-chemistry methods were explored to investigate the electronic structures, injection and transport properties, absorption and phosphorescence mechanism of a series of blue-emitting Ir(III) complexes {[(F-2-ppy)(2)Ir(pta -X/pyN4)], where F-2-ppy = (2,4-difluoro)phenylpyridine; pta = pyridine-1,2,4-triazole; X = phenyl(1); p-tolyl (2); 2,6-difluororophenyl (3); -CF3 (4), and pyN4 = pyridine-1,2,4-tetrazolate (5)}, which are used as emitters in organic light-emitting diodes (OLEDs). The mobility of hole and electron were studied computationally based on the Marcus theory. Calculations of Ionization potentials (IPs) and electron affinities (EAs) were used to evaluate the injection abilities of holes and electrons into these complexes.
Resumo:
We described here a new method for the determination of total calcium in plasma. The method is based on the precipitation of calcium with excess oxalate and the measurement of residual oxalate by flow injection analysis with Ru(bpy)(3)(2+) electrochemiluminescent detection. It has the advantages of extremely stable reagent, user-friendly instrument, high selectivity, good analytical recovery, wide dynamic range, and nice correlation with atomic absorption spectroscopy. The calibration plot for calcium is linear over a concentration range from 0.5 mmol L-1 to 4.8 mmol L-1, which is wider than those obtained by most other methods. The analytical recoveries for plasma calcium are 98.4-101.2% with coefficients of variation (CVs) of 1.96-2.52%. The within-day CVs range from 0.76% to 0.95%, and between-day CVs were from 1.12% to 1.46%. The time for each injection is one minute. Because the proposed method can be readily carried out on increasingly popular instruments for Ru(bpy)(3)(2+) ECL immunoassays and DNA probe assays, Ru(bpy)32+ ECL method is suitable for routine clinical analysis of calcium.
Resumo:
Comment
Resumo:
This paper describes the development of a two-dimensional transient catalyst model. Although designed primarily for two-stroke direct injection engines, the model is also applicable to four-stroke lean burn and diesel applications. The first section describes the geometries, properties and chemical processes simulated by the model and discusses the limitations and assumptions applied. A review of the modeling techniques adopted by other researchers is also included. The mathematical relationships which are used to represent the system are then described, together with the finite volume method used in the computer program. The need for a two-dimensional approach is explained and the methods used to model effects such as flow and temperature distribution are presented. The problems associated with developing surface reaction rates are discussed in detail and compared with published research. Validation and calibration of the model is achieved by comparing predictions with measurements from a flow reactor. While an extensive validation process, involving detailed measurements of gas composition and thermal gradients, has been completed, the analysis is too detailed for publication here and is the subject of a separate technical paper.
Resumo:
BACKGROUND: Male fertility potential cannot be measured by conventional parameters for assisted reproduction by intracytoplasmic sperm injection. This study determines the relationship between testicular and ejaculated sperm mitochondrial (mt) DNA deletions, nuclear (n) DNA fragmentation and fertilisation and pregnancy rates in ICSI. METHODS: Ejaculated sperm were obtained from 77 men and testicular sperm from 28 men with obstructive azoospermia undergoing ICSI. Testicular sperm were retrieved using a Trucut needle. MtDNA analysed using a long polymerase chain reaction. The alkaline Comet assay determined nDNA fragmentation. RESULTS: Of subjects who achieved a pregnancy (50%) using testicular sperm, only 26% had partners�??�?�¢?? sperm with wild type (WT) mtDNA. Of pregnant subjects (38%) using ejaculated sperm, only 8% had partner sperm with WT mtDNA.. In each, the successful group had less mtDNA deletions and less nDNA fragmentation. There were inverse relationships between pregnancy and mtDNA deletion numbers, size and nDNA fragmentation for both testicular and ejaculated sperm. No relationships were observed with fertilisation rates. An algorithm for the prediction of pregnancy is presented based on the quality of sperm nDNA and mtDNA. CONCLUSION: In both testicular and ejaculated sperm, mtDNA deletions and nDNA fragmentation are closely associated with pregnancy in ICSI.
Resumo:
Abstract BACKGROUND: Each year 40,000 men have a vasectomy in the UK whilst another 2400 request a reversal to begin a second family. Sperm can now be obtained by testicular biopsy and subsequently used in assisted conception with intracytoplasmic sperm injection (ICSI). The study aims were to compare sperm yields of men post-vasectomy or with obstructive azoospermia (OA) of unknown aetiology with fertile men and to assess any alteration in the clinical pregnancy rates after ICSI. METHODS: Testicular tissue was obtained by Trucut needle from men who had undergone a vasectomy >5yrs previously, had OA from other causes and from fertile men during vasectomy. Seminiferous tubules were milked to measure sperm yields. Numbers of Sertoli cells, spermatids and thickness of the seminiferous tubule walls were assessed using quantitative computerized analysis. RESULTS and CONCLUSIONS: Sperm yields/g testis were significantly decreased in men post-vasectomy and in men with OA, relative to fertile men. Significant reductions were also observed in early (40%) and mature (29%) spermatid numbers and an increase of 31% was seen in the seminiferous tubule wall (basal membrane and collagen thickness) of vasectomised men compared to fertile men. Clinical pregnancy rates in couples who had had a vasectomy were also significantly reduced.
Resumo:
BACKGROUND:
Plantar fasciitis is a common cause of heel pain. The aim of this study was twofold: to compare steroid injection with placebo injection and to compare ultrasound guided with unguided steroid injection in the management of this condition.
METHODS:
65 patients with inferior heel pain were recruited between November 2008 and June 2011. Heel pain was measured using a visual analogue scale (VAS) at baseline and follow-up 6 and 12 weeks after injection.
RESULTS:
22 patients were randomised to ultrasound guided steroid injection, 21 patients to palpation guided steroid injection and 22 to ultrasound guided placebo injection. There was a significant difference in VAS scores between the groups at 6 and 12 weeks (p=0.018 and p=0.004, respectively). There was a 19.7 (95% CI 2.5 to 37.0) difference in mean VAS scores at 6 weeks between the ultrasound guided steroid group and the placebo group and a 24.0 (95% CI 6.6 to 41.3) difference between the unguided steroid group and the placebo group at 6 weeks. At 12 weeks, the mean difference was 25.1 (95% CI 6.5 to 43.6) and 28.4 (95% CI 11.1 to 45.7) respectively between both steroid injection groups and the placebo group. There was no difference in VAS scores following steroid injection between the ultrasound guided and the unguided groups at either time point. Plantar fascia thickness was significantly reduced after injection in both active treatment groups (p=0.00).
CONCLUSIONS:
In this study, steroid injection showed a clear benefit over placebo at 6 weeks and this difference was maintained at 12 weeks.Trial Registration No ISRCTN79628180 (www.controlled-trials.com).