989 resultados para multi-pass amplifier


Relevância:

30.00% 30.00%

Publicador:

Resumo:

A multi-finger structure power SiGe HBT device (with an emitter area of about 166μm^2) is fabricated with very simple 2μm double-mesa technology. The DC current gain β is 144.25. The B-C junction breakdown voltage reaches 9V with a collector doping concentration of 1 × 10^17cm^-3 and a collector thickness of 400nm. Though our data are influenced by large additional RF probe pads, the device exhibits a maximum oscillation frequency fmax of 10.1GHz and a cut-off frequency fτ of 1.8GHz at a DC bias point of IC=10mA and VCE = 2.5V.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper we present an adaptation to the classical I/Q modulator topology which simultaneously allows it to operate both as a multi-modulation standard modulator, and as a high efficiency balanced amplifier. This is made possible by concurrently exploiting the ability of the Class E amplifiers to produce variable output power at maximum power added efficiency, PAE, by simple dc bias control while faithfully reproducing phase encoded signals. Experimental evidence for the behaviour of the modulator when operated in QPSK mode at 2.33 GHz with a 1 Msymbol/s rate shows that Error Vector Magnitude of less than 5% with amplifier PAE of 65% is possible. The multimode modulator presented here should lead to significantly reduced complexity, enhanced functionality transceivers for use in dc power sensitive handheld wireless applications. © 2007 EuMA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Power back-off performances of a new variant power-combining Class-E amplifier under different amplitude-modulation schemes such as continuous wave (CW), envelope elimination and restoration (EER), envelope tracking (ET) and outphasing are for the first time investigated in this study. Finite DC-feed inductances rather than massive RF chokes as used in the classic single-ended Class-E power amplifier (PA) resulted from the approximate yet effective frequency-domain circuit analysis provide the wherewithal to increase modulation bandwidth up to 80% higher than the classic single-ended Class-E PA. This increased modulation bandwidth is required for the linearity improvement in the EER/ET transmitters. The modified output load network of the power-combining Class-E amplifier adopting three-harmonic terminations technique relaxes the design specifications for the additional filtering block typically required at the output stage of the transmitter chain. Qualitative agreements between simulation and measurement results for all four schemes were achieved where the ET technique was proven superior to the other schemes. When the PA is used within the ET scheme, an increase of average drain efficiency of as high as 40% with respect to the CW excitation was obtained for a multi-carrier input signal with 12 dB peak-to-average power ratio. © 2011 The Institution of Engineering and Technology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, the envelope-tracking technique is exploited to boost average efficiency of the newly introduced broadband Inverse Class-E power amplifier. A 2.26 GHz - 20.5 dBm - 3 V power amplifier was designed, constructed, and measured. For a multi-carrier input signal with 10 dB peak-to-average ratio, the average PAE was increased from 5.7% to 54.5%. © 2008 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Power back-off performances of the modified power-combining Class-E amplifier under different amplitudemodulation schemes such as envelope elimination and restoration (EER) and envelope tracking (ET) are experimentally assessed in this paper. The modified output load network adopting three-harmonic terminations technique eliminates the need for additional lossy filtering section in the transmitter chain. Small dc-feed inductances rather than massive RF chokes as in the classic Class-E amplifier are used so as to increase the modulation bandwidth and therefore improve the linearity of the EER transmitter. High efficiency over a wide dynamic range using amplitude modulation through drain-voltage control (EER) was achieved and this agrees well with the Class-E theoretical prediction. When the PA was used within the ET scheme, an increase of average drain efficiency of as high as 40% with respect to the CW excitation was obtained for a multi-carrier input signal with 12dB peak-to-average power ratio. © 2011 Institut fur Mikrowellen.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

For the first time in this paper we present results showing the effect of speaker head pose angle on automatic lip-reading performance over a wide range of closely spaced angles. We analyse the effect head pose has upon the features themselves and show that by selecting coefficients with minimum variance w.r.t. pose angle, recognition performance can be improved when train-test pose angles differ. Experiments are conducted using the initial phase of a unique multi view Audio-Visual database designed specifically for research and development of pose-invariant lip-reading systems. We firstly show that it is the higher order horizontal spatial frequency components that become most detrimental as the pose deviates. Secondly we assess the performance of different feature selection masks across a range of pose angles including a new mask based on Minimum Cross-Pose Variance coefficients. We report a relative improvement of 50% in Word Error Rate when using our selection mask over a common energy based selection during profile view lip-reading.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To demonstrate the benefit of complexity metrics such as the modulation complexity score (MCS) and monitor units (MUs) in multi-institutional audits of volumetric-modulated arc therapy (VMAT) delivery.

METHODS: 39 VMAT treatment plans were analysed using MCS and MU. A virtual phantom planning exercise was planned and independently measured using the PTW Octavius(®) phantom and seven29(®) 2D array (PTW-Freiburg GmbH, Freiburg, Germany). MCS and MU were compared with the median gamma index pass rates (2%/2 and 3%/3 mm) and plan quality. The treatment planning systems (TPS) were grouped by VMAT modelling being specifically designed for the linear accelerator manufacturer's own treatment delivery system (Type 1) or independent of vendor for VMAT delivery (Type 2). Differences in plan complexity (MCS and MU) between TPS types were compared.

RESULTS: For Varian(®) linear accelerators (Varian(®) Medical Systems, Inc., Palo Alto, CA), MCS and MU were significantly correlated with gamma pass rates. Type 2 TPS created poorer quality, more complex plans with significantly higher MUs and MCS than Type 1 TPS. Plan quality was significantly correlated with MU for Type 2 plans. A statistically significant correlation was observed between MU and MCS for all plans (R = -0.84, p < 0.01).

CONCLUSION: MU and MCS have a role in assessing plan complexity in audits along with plan quality metrics. Plan complexity metrics give some indication of plan deliverability but should be analysed with plan quality.

ADVANCES IN KNOWLEDGE: Complexity metrics were investigated for a national rotational audit involving 34 institutions and they showed value. The metrics found that more complex plans were created for planning systems which were independent of vendor for VMAT delivery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The continuous demand for highly efficient wireless transmitter systems has triggered an increased interest in switching mode techniques to handle the required power amplification. The RF carrier amplitude-burst transmitter, i.e. a wireless transmitter chain where a phase-modulated carrier is modulated in amplitude in an on-off mode, according to some prescribed envelope-to-time conversion, such as pulse-width or sigma-delta modulation, constitutes a promising architecture capable of efficiently transmitting signals of highly demanding complex modulation schemes. However, the tested practical implementations present results that are way behind the theoretically advanced promises (perfect linearity and efficiency). My original contribution to knowledge presented in this thesis is the first thorough study and model of the power efficiency and linearity characteristics that can be actually achieved with this architecture. The analysis starts with a brief revision of the theoretical idealized behavior of these switched-mode amplifier systems, followed by the study of the many sources of impairments that appear when the real system is implemented. In particular, a special attention is paid to the dynamic load modulation caused by the often ignored interaction between the narrowband signal reconstruction filter and the usual single-ended switched-mode power amplifier, which, among many other performance impairments, forces a two transistor implementation. The performance of this architecture is clearly explained based on the presented theory, which is supported by simulations and corresponding measured results of a fully working implementation. The drawn conclusions allow the development of a set of design rules for future improvements, one of which is proposed and verified in this thesis. It suggests a significant modification to this traditional architecture, where now the phase modulated carrier is always on – and thus allowing a single transistor implementation – and the amplitude is impressed into the carrier phase according to a bi-phase code.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tese de dout., Engenharia Electrónica e de Computadores, Faculdade de Ciência e Tecnologia, Universidade do Algarve, 2007

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article draws from an ongoing Australian research project with over 60 culturally and sexually diverse women in monogamous, open, and polyamorous relationships with bisexual-identifying and/or bisexualbehaving men. Positioned within a queer feminist deconstructive theoretical framework, this research provides insights into the border existences of these women and their partners, and their negotiations of “new rules” and boundaries in order to construct healthy relationships. What are the various ways that HIV/AIDS impacts women in relationships with bisexual men? How do they deal with issues such as social, community, workplace and familial ostracism? Probyn's term, “outside belonging” (1996: 9) is applicable to the border existences of thesewomen and their bisexual male partners. Their multi-sexual relationships are both “outside” gendernormative and heteronormative constructs of marital and defacto relationships and yet “belonging,” for the partnersmay “pass” as a “normal” couple. They are also “outside” the dominant constructs of Australian gay identity and community while simultaneously “belonging” due to their partners', and sometimes their own, same-sex attractions and relationships.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives
This paper reports the quantitative findings of the first phase of a larger program of ongoing research: Feedback Incorporating Review and Simulation Techniques to Act on Clinical Trends (FIRST2ACTTM). It specifically aims to identify the characteristics that may predict primary outcome measures of clinical performance, teamwork and situation awareness in the management of deteriorating patients.

Design
Mixed-method multi-centre study.

Setting
High fidelity simulated acute clinical environment in three Australian universities.

Participants
A convenience sample of 97 final year nursing students enrolled in an undergraduate Bachelor of Nursing or combined Bachelor of Nursing degree were included in the study.

Method
In groups of three, participants proceeded through three phases: (i) pre-briefing and completion of a multi-choice question test, (ii) three video-recorded simulated clinical scenarios where actors substituted real patients with deteriorating conditions, and (iii) post-scenario debriefing. Clinical performance, teamwork and situation awareness were evaluated, using a validated standard checklist (OSCE), Team Emergency Assessment Measure (TEAM) score sheet and Situation Awareness Global Assessment Technique (SAGAT). A Modified Angoff technique was used to establish cut points for clinical performance.

Results
Student teams engaged in 97 simulation experiences across the three scenarios and achieved a level of clinical performance consistent with the experts' identified pass level point in only 9 (1%) of the simulation experiences. Knowledge was significantly associated with overall teamwork (p = .034), overall situation awareness (p = .05) and clinical performance in two of the three scenarios (p = .032 cardiac and p = .006 shock). Situation awareness scores of scenario team leaders were low overall, with an average total score of 41%.

Conclusions
Final year undergraduate nursing students may have difficulty recognising and responding appropriately to patient deterioration. Improving pre-requisite knowledge, rehearsal of first response and team management strategies need to be a key component of undergraduate nursing students' education and ought to specifically address clinical performance, teamwork and situation awareness.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The focus of this thesis is to discuss the development and modeling of an interface architecture to be employed for interfacing analog signals in mixed-signal SOC. We claim that the approach that is going to be presented is able to achieve wide frequency range, and covers a large range of applications with constant performance, allied to digital configuration compatibility. Our primary assumptions are to use a fixed analog block and to promote application configurability in the digital domain, which leads to a mixed-signal interface. The use of a fixed analog block avoids the performance loss common to configurable analog blocks. The usage of configurability on the digital domain makes possible the use of all existing tools for high level design, simulation and synthesis to implement the target application, with very good performance prediction. The proposed approach utilizes the concept of frequency translation (mixing) of the input signal followed by its conversion to the ΣΔ domain, which makes possible the use of a fairly constant analog block, and also, a uniform treatment of input signal from DC to high frequencies. The programmability is performed in the ΣΔ digital domain where performance can be closely achieved according to application specification. The interface performance theoretical and simulation model are developed for design space exploration and for physical design support. Two prototypes are built and characterized to validate the proposed model and to implement some application examples. The usage of this interface as a multi-band parametric ADC and as a two channels analog multiplier and adder are shown. The multi-channel analog interface architecture is also presented. The characterization measurements support the main advantages of the approach proposed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Optical networks based on passive star couplers and employing wavelength-division multiplexing (WDhf) have been proposed for deployment in local and metropolitan areas. Amplifiers are required in such networks to compensate for the power losses due to splitting and attenuation. However, an optical amplifier has constraints on the maximum gain and the maximum output power it can supply; thus optical amplifier placement becomes a challenging problem. The general problem of minimizing the total amplifier count, subject to the device constraints, is a mixed-integer non-linear problem. Previous studies have attacked the amplifier placement problem by adding the “artificial” constraint that all wavelengths, which are present at a particular point in a fiber, be at the same power level. In this paper, we present a method to solve the minimum amplifier- placement problem while avoiding the equally powered- wavelength constraint. We demonstrate that, by allowing signals to operate at different power levels, our method can reduce the number of amplifiers required in several small to medium-sized networks.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Human reactions to vibration have been extensively investigated in the past. Vibration, as well as whole-body vibration (WBV), has been commonly considered as an occupational hazard for its detrimental effects on human condition and comfort. Although long term exposure to vibrations may produce undesirable side-effects, a great part of the literature is dedicated to the positive effects of WBV when used as method for muscular stimulation and as an exercise intervention. Whole body vibration training (WBVT) aims to mechanically activate muscles by eliciting neuromuscular activity (muscle reflexes) via the use of vibrations delivered to the whole body. The most mentioned mechanism to explain the neuromuscular outcomes of vibration is the elicited neuromuscular activation. Local tendon vibrations induce activity of the muscle spindle Ia fibers, mediated by monosynaptic and polysynaptic pathways: a reflex muscle contraction known as the Tonic Vibration Reflex (TVR) arises in response to such vibratory stimulus. In WBVT mechanical vibrations, in a range from 10 to 80 Hz and peak to peak displacements from 1 to 10 mm, are usually transmitted to the patient body by the use of oscillating platforms. Vibrations are then transferred from the platform to a specific muscle group through the subject body. To customize WBV treatments, surface electromyography (SEMG) signals are often used to reveal the best stimulation frequency for each subject. Use of SEMG concise parameters, such as root mean square values of the recordings, is also a common practice; frequently a preliminary session can take place in order to discover the more appropriate stimulation frequency. Soft tissues act as wobbling masses vibrating in a damped manner in response to mechanical excitation; Muscle Tuning hypothesis suggest that neuromuscular system works to damp the soft tissue oscillation that occurs in response to vibrations; muscles alters their activity to dampen the vibrations, preventing any resonance phenomenon. Muscle response to vibration is however a complex phenomenon as it depends on different parameters, like muscle-tension, muscle or segment-stiffness, amplitude and frequency of the mechanical vibration. Additionally, while in the TVR study the applied vibratory stimulus and the muscle conditions are completely characterised (a known vibration source is applied directly to a stretched/shortened muscle or tendon), in WBV study only the stimulus applied to a distal part of the body is known. Moreover, mechanical response changes in relation to the posture. The transmissibility of vibratory stimulus along the body segment strongly depends on the position held by the subject. The aim of this work was the investigation on the effects that the use of vibrations, in particular the effects of whole body vibrations, may have on muscular activity. A new approach to discover the more appropriate stimulus frequency, by the use of accelerometers, was also explored. Different subjects, not affected by any known neurological or musculoskeletal disorders, were voluntarily involved in the study and gave their informed, written consent to participate. The device used to deliver vibration to the subjects was a vibrating platform. Vibrations impressed by the platform were exclusively vertical; platform displacement was sinusoidal with an intensity (peak-to-peak displacement) set to 1.2 mm and with a frequency ranging from 10 to 80 Hz. All the subjects familiarized with the device and the proper positioning. Two different posture were explored in this study: position 1 - hack squat; position 2 - subject standing on toes with heels raised. SEMG signals from the Rectus Femoris (RF), Vastus Lateralis (VL) and Vastus medialis (VM) were recorded. SEMG signals were amplified using a multi-channel, isolated biomedical signal amplifier The gain was set to 1000 V/V and a band pass filter (-3dB frequency 10 - 500 Hz) was applied; no notch filters were used to suppress line interference. Tiny and lightweight (less than 10 g) three-axial MEMS accelerometers (Freescale semiconductors) were used to measure accelerations of onto patient’s skin, at EMG electrodes level. Accelerations signals provided information related to individuals’ RF, Biceps Femoris (BF) and Gastrocnemius Lateralis (GL) muscle belly oscillation; they were pre-processed in order to exclude influence of gravity. As demonstrated by our results, vibrations generate peculiar, not negligible motion artifact on skin electrodes. Artifact amplitude is generally unpredictable; it appeared in all the quadriceps muscles analysed, but in different amounts. Artifact harmonics extend throughout the EMG spectrum, making classic high-pass filters ineffective; however, their contribution was easy to filter out from the raw EMG signal with a series of sharp notch filters centred at the vibration frequency and its superior harmonics (1.5 Hz wide). However, use of these simple filters prevents the revelation of EMG power potential variation in the mentioned filtered bands. Moreover our experience suggests that the possibility of reducing motion artefact, by using particular electrodes and by accurately preparing the subject’s skin, is not easily viable; even though some small improvements were obtained, it was not possible to substantially decrease the artifact. Anyway, getting rid of those artifacts lead to some true EMG signal loss. Nevertheless, our preliminary results suggest that the use of notch filters at vibration frequency and its harmonics is suitable for motion artifacts filtering. In RF SEMG recordings during vibratory stimulation only a little EMG power increment should be contained in the mentioned filtered bands due to synchronous electromyographic activity of the muscle. Moreover, it is better to remove the artifact that, in our experience, was found to be more than 40% of the total signal power. In summary, many variables have to be taken into account: in addition to amplitude, frequency and duration of vibration treatment, other fundamental variables were found to be subject anatomy, individual physiological condition and subject’s positioning on the platform. Studies on WBV treatments that include surface EMG analysis to asses muscular activity during vibratory stimulation should take into account the presence of motion artifacts. Appropriate filtering of artifacts, to reveal the actual effect on muscle contraction elicited by vibration stimulus, is mandatory. However as a result of our preliminary study, a simple multi-band notch filtering may help to reduce randomness of the results. Muscle tuning hypothesis seemed to be confirmed. Our results suggested that the effects of WBV are linked to the actual muscle motion (displacement). The greater was the muscle belly displacement the higher was found the muscle activity. The maximum muscle activity has been found in correspondence with the local mechanical resonance, suggesting a more effective stimulation at the specific system resonance frequency. Holding the hypothesis that muscle activation is proportional to muscle displacement, treatment optimization could be obtained by simply monitoring local acceleration (resonance). However, our study revealed some short term effects of vibratory stimulus; prolonged studies should be assembled in order to consider the long term effectiveness of these results. Since local stimulus depends on the kinematic chain involved, WBV muscle stimulation has to take into account the transmissibility of the stimulus along the body segment in order to ensure that vibratory stimulation effectively reaches the target muscle. Combination of local resonance and muscle response should also be further investigated to prevent hazards to individuals undergoing WBV treatments.