894 resultados para minor surgical procedures
Resumo:
Background: Previous studies have shown that membrane elevation results in predictable bone formation in the maxillary sinus provided that implants can be placed as tent poles. In situations with an extremely thin residual crest which impairs implant placement, it is possible that a space-making device can be used under the sinus membrane to promote bone formation prior to placement of implants. Purpose: The present study was conducted to test the hypothesis that the use of a space-making device for elevation of the sinus membrane will result in predictable bone formation at the maxillary sinus floor to allow placement of dental implants. Materials and Methods: Eight tufted capuchin primates underwent bilateral sinus membrane elevation surgery, and a bioresorbable space-making device, about 6 mm wide and 6 mm in height, was placed below the elevated membrane on the sinus floor. An oxidized implant (Nobel Biocare AB, Gothenburg, Sweden) was installed in the residual bone protruding into the created space at one side while the other side was left without an implant. Four animals were sacrificed after 6 months of healing. The remaining four animals received a second implant in the side with a space-making device only and followed for another 3 months before sacrifice. Implant stability was assessed through resonance frequency analysis (RFA) using the Osstell™ (Osstell AB, Gothenburg, Sweden) at installation, 6 months and 9 months after the first surgery. The bone-implant contact (BIC) and bone area inside the threads (BA) were histometrically evaluated in ground sections. Results: Histologically there were only minor or no signs of bone formation in the sites with a space-making device only. Sites with simultaneous implant placement showed bone formation along the implant surface. Sites with delayed implant placement showed minor or no bone formation and/or formation of a dense fibrous tissue along the apical part of the implant surface. In the latter group the apical part of the implant was not covered with the membrane but protruded into the sinus cavity. Conclusions: The use of a space-making device, with the design used in the present study, does not result in bone formation at the sinus floor. However, membrane elevation and simultaneous placement of the device and an implant does result in bone formation at the implant surface while sites with implants placed 6 months after membrane elevation show only small amounts of bone formation. It is suggested that lack of stabilization of the device and/or a too extensive elevation of the membrane may explain the results. © 2009, Wiley Periodicals, Inc.
Resumo:
The treatment of Class II adult individuals with mandibular deficiency has been the combination of orthodontic treatment and orthognathic surgery. Therefore, a study was conducted in which cephalometric analysis was used to evaluate the influence of dentoalveolar decompensation in Class II patients submitted to orthodontic and surgical treatment for mandibular advancement, by bilateral osteotomy of the mandibular ramus. A sample of 15 leukoderma adult female patients were selected and three cephalometric radiographs of each patient, taken before the orthodontic treatment, before surgery and after at least 6 months postoperatively, were analyzed in a total of 45 roentgenograms. The tracings were made by the manual method and the points were digitalized using software. The results showed that values of SNB increased from 75.6 to 78.6°. The measures BNP and PGNP were reduced from -12.7 to -7.7 mm and -12.7 to -6.6 mm, respectively. For ANB there was a reduction of 3.23° (from 8.1° to 4.9°). Likewise, the values of AOBO were diminished by 6.3 mm (from 7.6 to 1.3 mm), and in the values of OJ there was a reduction of 5.7 mm (from 9 to 3.3 mm). It was concluded that the pre-surgical orthodontic treatment promoted minimal and variable dental and skeletal changes in the final result. The surgical treatment caused significant skeletal changes, especially in the measurements related to the mandible (SNB, BNP, PGNP and SNPM) or indirectly to it (ANB, AOBO and OJ).
Resumo:
The purpose of this study was to evaluate skeletal and dental stability in patients who had temporomandibular joint (TMJ) reconstruction and mandibular counterclockwise advancement using TMJ Concepts total join, prostheses (TMJ Concepts Inc. Ventura, CA) with maxillary osteotomies being performed at the same operation. All patients were operated at Baylor University Medical Center, Dallas TX, USA, by one surgeon (Wolford). Forty-seven females were studied; the average post-surgical follow-up was 40.6 months. Lateral cephalograms were analyzed to estimate surgical and post-surgical changes. During surgery, the occlusal plane angle decreased 14.9 +/- 8.0 degrees. The maxilla moved forward and upward. The posterior nasal spine moved downward and forward. The mandible advanced 7.9 +/- 3.5 mm at the lower incisor tips, 12.4 +/- 5.4 mm at Point B, 17.3 +/- 7.0 mm at menton, 18.4 +/- 8.5 mm at pogonion, and 11.0 +/- 5.3 mm at gonion. Vertically, the lower incisors moved upward -2.9 +/- 4.0 mm. At the longest follow-up post surgery, the maxilla showed minor horizontal changes while all mandibular measurements remained stable. TMJ reconstruction and mandibular advancement with TMJ Concepts total joint prosthesis in conjunction with maxillary osteotomies for counter-clockwise rotation of the rnaxillo-mandibular complex was a stable procedure for these patients at the longest follow-up.
Resumo:
The frontal sinus fractures are derived from accidents of great intensity. Are usually associated with fractures of the midface, including the naso-orbital fractures and zygomatic ethmoid. Several treatment modalities have been proposed. In this case it was used to access bicoronal reconstruction of the anterior frontal sinus, and restore contour fronto-naso-orbital-ethmoid with satisfactory results.
Resumo:
Background and Purpose: Becoming proficient in laparoscopic surgery is dependent on the acquisition of specialized skills that can only be obtained from specific training. This training could be achieved in various ways using inanimate models, animal models, or live patient surgery-each with its own pros and cons. Currently, there are substantial data that support the benefits of animal model training in the initial learning of laparoscopy. Nevertheless, whether these benefits extent themselves to moderately experienced surgeons is uncertain. The purpose of this study was to determine if training using a porcine model results in a quantifiable gain in laparoscopic skills for moderately experienced laparoscopic surgeons. Materials and Methods: Six urologists with some laparoscopic experience were asked to perform a radical nephrectomy weekly for 10 weeks in a porcine model. The procedures were recorded, and surgical performance was assessed by two experienced laparoscopic surgeons using a previously published surgical performance assessment tool. The obtained data were then submitted to statistical analysis. Results: With training, blood loss was reduced approximately 45% when comparing the averages of the first and last surgical procedures (P = 0.006). Depth perception showed an improvement close to 35% (P = 0.041), and dexterity showed an improvement close to 25% (P = 0.011). Total operative time showed trends of improvement, although it was not significant (P = 0.158). Autonomy, efficiency, and tissue handling were the only aspects that did not show any noteworthy change (P = 0.202, P = 0.677, and P = 0.456, respectively). Conclusions: These findings suggest that there are quantifiable gains in laparoscopic skills obtained from training in an animal model. Our results suggest that these benefits also extend to more advanced stages of the learning curve, but it is unclear how far along the learning curve training with animal models provides a clear benefit for the performance of laparoscopic procedures. Future studies are necessary to confirm these findings and better understand the impact of this learning tool on surgical practice.
Resumo:
Surgical approaches to pancreatic endocrine tumors associated with multiple endocrine neoplasia type 1 may differ greatly from those applied to sporadic pancreatic endocrine tumors. Presurgical diagnosis of multiple endocrine neoplasia type 1 is therefore crucial to plan a proper intervention. Of note, hyperparathyroidism/multiple endocrine neoplasia type 1 should be surgically treated before pancreatic endocrine tumors/multiple endocrine neoplasia type 1 resection, apart from insulinoma. Non-functioning pancreatic endocrine tumors/multiple endocrine neoplasia type 1 >1 cm have a high risk of malignancy and should be treated by a pancreatic resection associated with lymphadenectomy. The vast majority of patients with gastrinoma/multiple endocrine neoplasia type 1 present with tumor lesions at the duodenum, so the surgery of choice is subtotal or total pancreatoduodenectomy followed by regional lymphadenectomy. The usual surgical treatment for insulinoma/multiple endocrine neoplasia type 1 is distal pancreatectomy up to the mesenteric vein with or without spleen preservation, associated with enucleation of tumor lesions in the pancreatic head. Surgical procedures for glucagonomas, somatostatinomas, and vipomas/ multiple endocrine neoplasia type 1 are similar to those applied to sporadic pancreatic endocrine tumors. Some of these surgical strategies for pancreatic endocrine tumors/multiple endocrine neoplasia type 1 still remain controversial as to their proper extension and timing. Furthermore, surgical resection of single hepatic metastasis secondary to pancreatic endocrine tumors/multiple endocrine neoplasia type 1 may be curative and even in multiple liver metastases surgical resection is possible. Hepatic trans-arterial chemo-embolization is usually associated with surgical resection. Liver transplantation may be needed for select cases. Finally, pre-surgical clinical and genetic diagnosis of multiple endocrine neoplasia type 1 syndrome and localization of multiple endocrine neoplasia type 1related tumors are crucial for determining the best surgical strategies in each individual case with pancreatic endocrine tumors.
Resumo:
In case of severe osteoarthritis at the knee causing pain, deformity, and loss of stability and mobility, the clinicians consider that the substitution of these surfaces by means of joint prostheses. The objectives to be pursued by this surgery are: complete pain elimination, restoration of the normal physiological mobility and joint stability, correction of all deformities and, thus, of limping. The knee surgical navigation systems have bee developed in computer-aided surgery in order to improve the surgical final outcome in total knee arthroplasty. These systems provide the surgeon with quantitative and real-time information about each surgical action, like bone cut executions and prosthesis component alignment, by mean of tracking tools rigidly fixed onto the femur and the tibia. Nevertheless, there is still a margin of error due to the incorrect surgical procedures and to the still limited number of kinematic information provided by the current systems. Particularly, patello-femoral joint kinematics is not considered in knee surgical navigation. It is also unclear and, thus, a source of misunderstanding, what the most appropriate methodology is to study the patellar motion. In addition, also the knee ligamentous apparatus is superficially considered in navigated total knee arthroplasty, without taking into account how their physiological behavior is altered by this surgery. The aim of the present research work was to provide new functional and biomechanical assessments for the improvement of the surgical navigation systems for joint replacement in the human lower limb. This was mainly realized by means of the identification and development of new techniques that allow a thorough comprehension of the functioning of the knee joint, with particular attention to the patello-femoral joint and to the main knee soft tissues. A knee surgical navigation system with active markers was used in all research activities presented in this research work. Particularly, preliminary test were performed in order to assess the system accuracy and the robustness of a number of navigation procedures. Four studies were performed in-vivo on patients requiring total knee arthroplasty and randomly implanted by means of traditional and navigated procedures in order to check for the real efficacy of the latter with respect to the former. In order to cope with assessment of patello-femoral joint kinematics in the intact and replaced knees, twenty in-vitro tests were performed by using a prototypal tracking tool also for the patella. In addition to standard anatomical and articular recommendations, original proposals for defining the patellar anatomical-based reference frame and for studying the patello-femoral joint kinematics were reported and used in these tests. These definitions were applied to two further in-vitro tests in which, for the first time, also the implant of patellar component insert was fully navigated. In addition, an original technique to analyze the main knee soft tissues by means of anatomical-based fiber mappings was also reported and used in the same tests. The preliminary instrumental tests revealed a system accuracy within the millimeter and a good inter- and intra-observer repeatability in defining all anatomical reference frames. In in-vivo studies, the general alignments of femoral and tibial prosthesis components and of the lower limb mechanical axis, as measured on radiographs, was more satisfactory, i.e. within ±3°, in those patient in which total knee arthroplasty was performed by navigated procedures. As for in-vitro tests, consistent patello-femoral joint kinematic patterns were observed over specimens throughout the knee flexion arc. Generally, the physiological intact knee patellar motion was not restored after the implant. This restoration was successfully achieved in the two further tests where all component implants, included the patellar insert, were fully navigated, i.e. by means of intra-operative assessment of also patellar component positioning and general tibio-femoral and patello-femoral joint assessment. The tests for assessing the behavior of the main knee ligaments revealed the complexity of the latter and the different functional roles played by the several sub-bundles compounding each ligament. Also in this case, total knee arthroplasty altered the physiological behavior of these knee soft tissues. These results reveal in-vitro the relevance and the feasibility of the applications of new techniques for accurate knee soft tissues monitoring, patellar tracking assessment and navigated patellar resurfacing intra-operatively in the contest of the most modern operative techniques. This present research work gives a contribution to the much controversial knowledge on the normal and replaced of knee kinematics by testing the reported new methodologies. The consistence of these results provides fundamental information for the comprehension and improvements of knee orthopedic treatments. In the future, the reported new techniques can be safely applied in-vivo and also adopted in other joint replacements.
Resumo:
Craniosynostosis consists of a premature fusion of the sutures in an infant skull that restricts skull and brain growth. During the last decades, there has been a rapid increase of fundamentally diverse surgical treatment methods. At present, the surgical outcome has been assessed using global variables such as cephalic index, head circumference, and intracranial volume. However, these variables have failed in describing the local deformations and morphological changes that may have a role in the neurologic disorders observed in the patients. This report describes a rigid image registration-based method to evaluate outcomes of craniosynostosis surgical treatments, local quantification of head growth, and indirect intracranial volume change measurements. The developed semiautomatic analysis method was applied to computed tomography data sets of a 5-month-old boy with sagittal craniosynostosis who underwent expansion of the posterior skull with cranioplasty. Quantification of the local changes between pre- and postoperative images was quantified by mapping the minimum distance of individual points from the preoperative to the postoperative surface meshes, and indirect intracranial volume changes were estimated. The proposed methodology can provide the surgeon a tool for the quantitative evaluation of surgical procedures and detection of abnormalities of the infant skull and its development.
Resumo:
OBJECTIVES: To compare the clinical outcomes of standard, cylindrical, screw-shaped to novel tapered, transmucosal (Straumann Dental implants immediately placed into extraction sockets. Material and methods: In this randomized-controlled clinical trial, outcomes were evaluated over a 3-year observation period. This report deals with the need for bone augmentation, healing events, implant stability and patient-centred outcomes up to 3 months only. Nine centres contributed a total of 208 immediate implant placements. All surgical and post-surgical procedures and the evaluation parameters were discussed with representatives of all centres during a calibration meeting. Following careful luxation of the designated tooth, allocation of the devices was randomly performed by a central study registrar. The allocated SLA titanium implant was installed at the bottom or in the palatal wall of the extraction socket until primary stability was reached. If the extraction socket was >or=1 mm larger than the implant, guided bone regeneration was performed simultaneously (Bio Oss and BioGide. The flaps were then sutured. During non-submerged transmucosal healing, everything was done to prevent infection. At surgery, the need for augmentation and the degree of wound closure was verified. Implant stability was assessed clinically and by means of resonance frequency analysis (RFA) at surgery and after 3 months. Wound healing was evaluated after 1, 2, 6 and 12 weeks post-operatively. RESULTS: The demographic data did not show any differences between the patients receiving either standard cylindrical or tapered implants. All implants yielded uneventful healing with 15% wound dehiscences after 1 week. After 2 weeks, 93%, after 6 weeks 96%, and after 12 weeks 100% of the flaps were closed. Ninety percent of both implant designs required bone augmentation. Immediately after implantation, RFA values were 55.8 and 56.7 and at 3 months 59.4 and 61.1 for cylindrical and tapered implants, respectively. Patient-centred outcomes did not differ between the two implant designs. However, a clear preference of the surgeon's perception for the appropriateness of the novel-tapered implant was evident. CONCLUSIONS: This RCT has demonstrated that tapered or standard cylindrical implants yielded clinically equivalent short-term outcomes after immediate implant placement into the extraction socket.
Resumo:
A patient-specific surface model of the proximal femur plays an important role in planning and supporting various computer-assisted surgical procedures including total hip replacement, hip resurfacing, and osteotomy of the proximal femur. The common approach to derive 3D models of the proximal femur is to use imaging techniques such as computed tomography (CT) or magnetic resonance imaging (MRI). However, the high logistic effort, the extra radiation (CT-imaging), and the large quantity of data to be acquired and processed make them less functional. In this paper, we present an integrated approach using a multi-level point distribution model (ML-PDM) to reconstruct a patient-specific model of the proximal femur from intra-operatively available sparse data. Results of experiments performed on dry cadaveric bones using dozens of 3D points are presented, as well as experiments using a limited number of 2D X-ray images, which demonstrate promising accuracy of the present approach.
Resumo:
OBJECTIVE: To quantify the economic burden of in-hospital surgical site infections (SSIs) at a European university hospital. DESIGN: Matched case-control study nested in a prospective observational cohort study. SETTING: Basel University Hospital in Switzerland, where an average of 28,000 surgical procedures are performed per year. METHODS: All in-hospital occurrences of SSI associated with surgeries performed between January 1, 2000, and December 31, 2001, by the visceral, vascular, and traumatology divisions at Basel University Hospital were prospectively recorded. Each case patient was matched to a control patient by age, procedure code, and National Nosocomial Infection Surveillance System risk index. The case-control pairs were analyzed for differences in cost of hospital care and in provision of specialized care. RESULTS: A total of 6,283 procedures were performed: 187 SSIs were detected in inpatients, 168 of whom were successfully matched with a control patient. For case patients, the mean additional hospital cost was SwF-19,638 (95% confidence interval [CI], SwF-8,492-SwF-30,784); the mean additional postoperative length of hospital stay was 16.8 days (95% CI, 13-20.6 days); and the mean additional in-hospital duration of antibiotic therapy was 7.4 days (95% CI, 5.1-9.6 days). Differences were primarily attributable to organ space SSIs (n = 76). CONCLUSIONS: In a European university hospital setting, SSIs are costly and constitute a heavy and potentially preventable burden on both patients and healthcare providers.
Resumo:
OBJECTIVE: To obtain precise information on the optimal time window for surgical antimicrobial prophylaxis. SUMMARY BACKGROUND DATA: Although perioperative antimicrobial prophylaxis is a well-established strategy for reducing the risk of surgical site infections (SSI), the optimal timing for this procedure has yet to be precisely determined. Under today's recommendations, antibiotics may be administered within the final 2 hours before skin incision, ideally as close to incision time as possible. METHODS: In this prospective observational cohort study at Basel University Hospital we analyzed the incidence of SSI by the timing of antimicrobial prophylaxis in a consecutive series of 3836 surgical procedures. Surgical wounds and resulting infections were assessed to Centers for Disease Control and Prevention standards. Antimicrobial prophylaxis consisted in single-shot administration of 1.5 g of cefuroxime (plus 500 mg of metronidazole in colorectal surgery). RESULTS: The overall SSI rate was 4.7% (180 of 3836). In 49% of all procedures antimicrobial prophylaxis was administered within the final half hour. Multivariable logistic regression analyses showed a significant increase in the odds of SSI when antimicrobial prophylaxis was administered less than 30 minutes (crude odds ratio = 2.01; adjusted odds ratio = 1.95; 95% confidence interval, 1.4-2.8; P < 0.001) and 120 to 60 minutes (crude odds ratio = 1.75; adjusted odds ratio = 1.74; 95% confidence interval, 1.0-2.9; P = 0.035) as compared with the reference interval of 59 to 30 minutes before incision. CONCLUSIONS: When cefuroxime is used as a prophylactic antibiotic, administration 59 to 30 minutes before incision is more effective than administration during the last half hour.
Resumo:
Research on surgical interventions is associated with several methodological and practical challenges of which few, if any, apply only to surgery. However, surgical evaluation is especially demanding because many of these challenges coincide. In this report, the second of three on surgical innovation and evaluation, we discuss obstacles related to the study design of randomised controlled trials and non-randomised studies assessing surgical interventions. We also describe the issues related to the nature of surgical procedures-for example, their complexity, surgeon-related factors, and the range of outcomes. Although difficult, surgical evaluation is achievable and necessary. Solutions tailored to surgical research and a framework for generating evidence on which to base surgical practice are essential.
Resumo:
Surgical innovation is an important part of surgical practice. Its assessment is complex because of idiosyncrasies related to surgical practice, but necessary so that introduction and adoption of surgical innovations can derive from evidence-based principles rather than trial and error. A regulatory framework is also desirable to protect patients against the potential harms of any novel procedure. In this first of three Series papers on surgical innovation and evaluation, we propose a five-stage paradigm to describe the development of innovative surgical procedures.
Resumo:
HYPOTHESIS: Clinically apparent surgical glove perforation increases the risk of surgical site infection (SSI). DESIGN: Prospective observational cohort study. SETTING: University Hospital Basel, with an average of 28,000 surgical interventions per year. PARTICIPANTS: Consecutive series of 4147 surgical procedures performed in the Visceral Surgery, Vascular Surgery, and Traumatology divisions of the Department of General Surgery. MAIN OUTCOME MEASURES: The outcome of interest was SSI occurrence as assessed pursuant to the Centers of Disease Control and Prevention standards. The primary predictor variable was compromised asepsis due to glove perforation. RESULTS: The overall SSI rate was 4.5% (188 of 4147 procedures). Univariate logistic regression analysis showed a higher likelihood of SSI in procedures in which gloves were perforated compared with interventions with maintained asepsis (odds ratio [OR], 2.0; 95% confidence interval [CI], 1.4-2.8; P < .001). However, multivariate logistic regression analyses showed that the increase in SSI risk with perforated gloves was different for procedures with vs those without surgical antimicrobial prophylaxis (test for effect modification, P = .005). Without antimicrobial prophylaxis, glove perforation entailed significantly higher odds of SSI compared with the reference group with no breach of asepsis (adjusted OR, 4.2; 95% CI, 1.7-10.8; P = .003). On the contrary, when surgical antimicrobial prophylaxis was applied, the likelihood of SSI was not significantly higher for operations in which gloves were punctured (adjusted OR, 1.3; 95% CI, 0.9-1.9; P = .26). CONCLUSION: Without surgical antimicrobial prophylaxis, glove perforation increases the risk of SSI.