967 resultados para mesh: Neuroscience


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to assess the applicability of posterior wall repair with a synthetic absorbable mesh. Between January and September 1996, five posterior repairs using absorbable synthetic meshes were performed. Five posterior wall repairs in patients matched for age, parity, and rectocele degree were performed according to usual procedures during the same period, and were used as controls. No febrile morbidity, cuff or posterior vaginal wall infections, thrombophlebitis, rectal injury, or hemorrhagic complications were observed in the 10 women who entered the study. In summary, posterior wall repair can be easily performed with an absorbable soft tissue patch, theoretically preserving sexual activity, and probably offers better functional results with longer experience, thus providing a safe and useful procedure in sexually active women.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Humans experience the self as localized within their body. This aspect of bodily self-consciousness can be experimentally manipulated by exposing individuals to conflicting multisensory input, or can be abnormal following focal brain injury. Recent technological developments helped to unravel some of the mechanisms underlying multisensory integration and self-location, but the neural underpinnings are still under investigation, and the manual application of stimuli resulted in large variability difficult to control. This paper presents the development and evaluation of an MR-compatible stroking device capable of presenting moving tactile stimuli to both legs and the back of participants lying on a scanner bed while acquiring functional neuroimaging data. The platform consists of four independent stroking devices with a travel of 16-20 cm and a maximum stroking velocity of 15 cm/s, actuated over non-magnetic ultrasonic motors. Complemented with virtual reality, this setup provides a unique research platform allowing to investigate multisensory integration and its effects on self-location under well-controlled experimental conditions. The MR-compatibility of the system was evaluated in both a 3 and a 7 Tesla scanner and showed negligible interference with brain imaging. In a preliminary study using a prototype device with only one tactile stimulator, fMRI data acquired on 12 healthy participants showed visuo-tactile synchrony-related and body-specific modulations of the brain activity in bilateral temporoparietal cortex.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to prospectively evaluate the accuracy and predictability of new three-dimensionally preformed AO titanium mesh plates for posttraumatic orbital wall reconstruction.We analyzed the preoperative and postoperative clinical and radiologic data of 10 patients with isolated blow-out orbital fractures. Fracture locations were as follows: floor (N = 7; 70%), medial wall (N = 1; 1%), and floor/medial wall (N = 2; 2%). The floor fractures were exposed by a standard transconjunctival approach, whereas a combined transcaruncular transconjunctival approach was used in patients with medial wall fractures. A three-dimensional preformed AO titanium mesh plate (0.4 mm in thickness) was selected according to the size of the defect previously measured on the preoperative computed tomographic (CT) scan examination and fixed at the inferior orbital rim with 1 or 2 screws. The accuracy of plate positioning of the reconstructed orbit was assessed on the postoperative CT scan. Coronal CT scan slices were used to measure bony orbital volume using OsiriX Medical Image software. Reconstructed versus uninjured orbital volume were statistically correlated.Nine patients (90%) had a successful treatment outcome without complications. One patient (10%) developed a mechanical limitation of upward gaze with a resulting handicapping diplopia requiring hardware removal. Postoperative orbital CT scan showed an anatomic three-dimensional placement of the orbital mesh plates in all of the patients. Volume data of the reconstructed orbit fitted that of the contralateral uninjured orbit with accuracy to within 2.5 cm(3). There was no significant difference in volume between the reconstructed and uninjured orbits.This preliminary study has demonstrated that three-dimensionally preformed AO titanium mesh plates for posttraumatic orbital wall reconstruction results in (1) a high rate of success with an acceptable rate of major clinical complications (10%) and (2) an anatomic restoration of the bony orbital contour and volume that closely approximates that of the contralateral uninjured orbit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Memory formation is known to occur at the level of synaptic contacts between neurons. It therefore comes as a surprise that another type of brain cell, the astrocyte, is also involved in establishing memory.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To prospectively evaluate the accuracy and reliability of "freehand" posttraumatic orbital wall reconstruction with AO (Arbeitsgemeinschaft Osteosynthese) titanium mesh plates by using computer-aided volumetric measurement of the bony orbits. METHODS: Bony orbital volume was measured in 12 patients from coronal CT scan slices using OsiriX Medical Image software. After defining the volumetric limits of the orbit, the segmentation of the bony orbital region of interest of each single slice was performed. At the end of the segmentation process, all regions of interest were grouped and the volume was computed. The same procedure was performed on both orbits, and thereafter the volume of the contralateral uninjured orbit was used as a control for comparison. RESULTS: In all patients, the volume data of the reconstructed orbit fitted that of the contralateral uninjured orbit with accuracy to within 1.85 cm3 (7%). CONCLUSIONS: This preliminary study has demonstrated that posttraumatic orbital wall reconstruction using "freehand" bending and placement of AO titanium mesh plates results in a high success rate in re-establishing preoperative bony volume, which closely approximates that of the contralateral uninjured orbit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Editors welcome topical correspondence from readers relating to articles published in the Journal. Responses should be sent electronically via the BJS website (www.bjs.co.uk). All letters will be reviewed and, if approved, appear on the website. A selection of these will be edited and published in the Journal. Letters must be no more than 250 words in length.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The saphenous vein is the conduit of choice in bypass graft procedures. Haemodynamic factors play a major role in the development of intimal hyperplasia (IH), and subsequent bypass failure. To evaluate the potential protective effect of external reinforcement on such a failure, we developed an ex vivo model for the perfusion of segments of human saphenous veins under arterial shear stress. In veins submitted to pulsatile high pressure (mean pressure at 100 mmHg) for 3 or 7 days, the use of an external macroporous polyester mesh 1) prevented the dilatation of the vessel, 2) decreased the development of IH, 3) reduced the apoptosis of smooth muscle cells, and the subsequent fibrosis of the media layer, 4) prevented the remodelling of extracellular matrix through the up-regulation of matrix metalloproteinases (MMP-2, MMP-9) and plasminogen activator type I. The data show that, in an experimental ex vivo setting, an external scaffold decreases IH and maintains the integrity of veins exposed to arterial pressure, via increase in shear stress and decrease wall tension, that likely contribute to trigger selective molecular and cellular changes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Implantación de un modelo de red abierta tipo mesh para propagar el acceso libre al servicio de biblioteca y contenidos abiertos.