960 resultados para measurement of time interval


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Autocrine ligands are important regulators of many normal tissues and have been implicated in a number of disease states, including cancer. However, because by definition autocrine ligands are synthesized, secreted, and bound to cell receptors within an intrinsically self-contained “loop,” standard pharmacological approaches cannot be used to investigate relationships between ligand/receptor binding and consequent cellular responses. We demonstrate here a new approach for measurement of autocrine ligand binding to cells, using a microphysiometer assay originally developed for investigating cell responses to exogenous ligands. This technique permits quantitative measurements of autocrine responses on the time scale of receptor binding and internalization, thus allowing investigation of the role of receptor trafficking and dynamics in cellular responses. We used this technique to investigate autocrine signaling through the epidermal growth factor receptor by transforming growth factor alpha (TGFα) and found that anti-receptor antibodies are far more effective than anti-ligand antibodies in inhibiting autocrine signaling. This result indicates that autocrine-based signals can operate in a spatially restricted, local manner and thus provide cells with information on their local microenvironment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The problem of similarity measurement of biological signals is considered on this article. The dynamic time warping algorithm is used as a possible solution. A short overview of this algorithm and its modifications are given. Testing procedure for different modifications of DTW, which are based on artificial test signals, are presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Shipboard analysis of the 1183-m sedimentary section recovered at Site 918 in the Irminger Basin during Ocean Drilling Program Leg 152 revealed material of glacial origin (diamictons, ice-rafted debris (IRD) and dropstones) as deep as 543 m below sea floor (bsf). The sediment containing the deepest dropstone was biostratigraphically dated shipboard as approximately 7 Ma, pushing back the date for the onset of glaciation on southern Greenland by 5 Ma. Thin layers of fine sand were found as much as 60 m deeper in the core, raising the possibility of an even earlier date for glaciation. To determine the sedimentary history of these deeper sand layers, the surface textures on quartz grains from eleven cores bracketing the interval of interest were analyzed by scanning electron microscope. The results suggest that the grains in the 60-m interval below the deepest dropstone have a glacial history. At that level, an 11 -Ma Sr-isotope date was obtained from planktonic foraminifers. This late Miocene timing is supported biostratigraphically by both nannofossil and foraminifer assemblages, indicating a new minimum age for the onset of glaciation on southern Greenland and in the North Atlantic.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

"Feed Materials Production Center, National Lead Company of Ohio"--Cover.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Strain and strain rate (SR) are measures of deformation that are basic descriptors of both the nature and the function of cardiac tissue. These properties may now be measured using either Doppler or two-dimensional ultrasound techniques. Although these measurements are feasible in routine clinical echocardiography, their acquisition and analysis nonetheless presents a number of technical challenges and complexities. Echocardiographic strain and SR imaging has been applied to the assessment of resting ventricular function, the assessment of myocardial viability using low-dose dobutamine infusion, and stress testing for ischemia. Resting function assessment has been applied in both the left and the fight ventricles, and may prove particularly valuable for identifying myocardial diseases and following up the treatment response. Although the evidence base is limited, SR imaging seems to be feasible and effective for the assessment of myocardial viability. The use of the technique for the detection of ischemia during stress echocardiography is technically challenging and likely to evolve further. The clinical availability of strain and SR measurement may offer a solution to the ongoing need for quantification of regional and global cardiac function. Nonetheless, these techniques are susceptible to artifact, and further technical development is necessary.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Accurate knowledge of the time since death, or postmortem interval (PMI), has enormous legal, criminological, and psychological impact. In this study, an investigation was made to determine whether the relationship between the degradation of the human cardiac structure protein Cardiac Troponin T and PMI could be used as an indicator of time since death, thus providing a rapid, high resolution, sensitive, and automated methodology for the determination of PMI. ^ The use of Cardiac Troponin T (cTnT), a protein found in heart tissue, as a selective marker for cardiac muscle damage has shown great promise in the determination of PMI. An optimized conventional immunoassay method was developed to quantify intact and fragmented cTnT. A small sample of cardiac tissue, which is less affected than other tissues by external factors, was taken, homogenized, extracted with magnetic microparticles, separated by SDS-PAGE, and visualized with Western blot by probing with monoclonal antibody against cTnT. This step was followed by labeling and available scanners. This conventional immunoassay provides a proper detection and quantitation of cTnT protein in cardiac tissue as a complex matrix; however, this method does not provide the analyst with immediate results. Therefore, a competitive separation method using capillary electrophoresis with laser-induced fluorescence (CE-LIF) was developed to study the interaction between human cTnT protein and monoclonal anti-TroponinT antibody. ^ Analysis of the results revealed a linear relationship between the percent of degraded cTnT and the log of the PMI, indicating that intact cTnT could be detected in human heart tissue up to 10 days postmortem at room temperature and beyond two weeks at 4C. The data presented demonstrates that this technique can provide an extended time range during which PMI can be more accurately estimated as compared to currently used methods. The data demonstrates that this technique represents a major advance in time of death determination through a fast and reliable, semi-quantitative measurement of a biochemical marker from an organ protected from outside factors. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: Patients with mild cognitive impairment (MCI) may have difficulties in time perception, which in turn might contribute to some of their symptoms, especially memory deficits. The aim of this study was to evaluate perception of interval length and subjective passage of time in MCI patients as compared to healthy controls. Methods: Fifty-five MCI patients and 57 healthy controls underwent an experimental protocol for time perception on interval length, a questionnaire for the subjective passage of time and a neuropsychological evaluation. Results: MCI patients presented no changes in the perception of interval length. However, for MCI patients, time seemed to pass more slowly than it did for controls. This experience was significantly correlated with memory deficits but not with performance in executive tests, nor with complaints of depression or anxiety. Conclusions: Memory deficits do not affect the perception of interval length, but are associated with alterations in the subjective passage of time.