993 resultados para joint failure


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: Biological and mechanical implant-abutment connection complications and failures are still present in clinical practice, frequently compromising oral function. The purpose of this study was to evaluate the reliability and failure modes of anterior single-unit restorations in internal conical interface (ICI) implants using step-stress accelerated life testing (SSALT). Materials and methods: Forty-two ICI implants were distributed in two groups (n = 21 each): group AT-OsseoSpeed™ TX (Astra Tech, Waltham, MA, USA); group SV-Duocon System Line, Morse Taper (Signo Vinces Ltda., Campo Largo, PR, Brazil). The corresponding abutments were screwed to the implants and standardized maxillary central incisor metal crowns were cemented and subjected to SSALT in water. Use-level probability Weibull curves and reliability for a mission of 50,000 cycles at 200 N were calculated. Differences between groups were assessed by Kruskal-Wallis along with Bonferroni's post-hoc tests. Polarized-light and scanning electron microscopes were used for failure analyses. Results: The Beta (β) value derived from use level probability Weibull calculation was 1.62 (1.01-2.58) for group AT and 2.56 (1.76-3.74) for group SV, indicating that fatigue was an accelerating factor for failure of both groups. The reliability for group AT was 0.95 and for group SV was 0.88. Kruskal-Wallis along with Bonferroni's post-hoc tests showed no significant difference between the groups tested (P > 0.27). In all specimens of both groups, the chief failure mode was abutment fracture at the conical joint region and screw fracture at neck's region. Conclusions: Reliability was not different between investigated ICI connections supporting maxillary incisor crowns. Failure modes were similar. © 2012 John Wiley & Sons A/S.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: This study compared the maintenance of tightening torque in different retention screw types of implant-supported crowns. Materials and Methods: Twelve metallic crowns in UCLA abutments cast with cobalt-chromium alloy were attached to external hexagon osseointegrated implants with different retention screws: group A: titanium alloy retention screw; group B: gold alloy retention screw with gold coating; group C: titanium alloy retention screw with diamond-like carbon film coating; and group D: titanium alloy retention screw with aluminum titanium nitride coating. Three detorque measurements were obtained after torque insertion in each replica. Data were evaluated by analysis of variance (ANOVA), Tukey's test (P < 0.05), and t test (P < 0.05). Results: Detorque value reduced in all groups (P < 0.05). Group A retained the highest percentage of torque in comparison with the other groups (P < 0.05). Groups B and D retained the lowest percentage of torque without statistically significant difference between them (P < 0.05). Conclusions: All screw types exhibited reduction in the detorque value. The titanium screw maintained the highest percentage of torque whereas the gold-coated screw and the titanium screw with aluminum titanium nitride coating retained the lowest percentage. (Implant Dent 2012;21:46-50)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Studies about the influence of patient characteristics on mechanical failure of cups in total hip replacement have applied different methodologies and revealed inconclusive results. The fixation mode has rarely been investigated. Therefore, we conducted a detailed analysis of the influence of patient characteristics and fixation mode on cup failure risks.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: In a previous study, twenty consecutive patients with a rerupture of the rotator cuff, as documented with magnetic resonance imaging, were found to have significantly less pain and better function and strength, compared with the preoperative state, at 3.2 years postoperatively. It was the purpose of this study to determine the clinical and structural outcomes of these reruptures in the same twenty patients after a longer period of follow-up. METHODS: At a mean of 7.6 years postoperatively, the twenty patients were reexamined clinically and with standard radiographs and magnetic resonance imaging with use of the same clinical, radiographic, and magnetic resonance imaging criteria as were utilized in the review at 3.2 years. The mean age at the time of final follow-up was sixty-six years. RESULTS: Nineteen of the twenty patients continued to be either very satisfied or satisfied with the outcome. The relative Constant score averaged 88% and was not significantly different from the score at 3.2 years, which averaged 83%. The mean scores for pain, function, and strength also had not changed significantly. Overall, the twenty reruptures had not increased in size, and eight of them had healed structurally at the time of the 7.6-year follow-up. Seven of these eight reruptures had been of the supraspinatus tendon only, and seven had been smaller than 400 mm(2) at 3.2 years. Twelve reruptures persisted, and five were larger than the preoperative tear. Fatty infiltration of the infraspinatus muscle progressed significantly (p = 0.015) and the acromiohumeral distance decreased significantly (p = 0.006) between the two follow-up periods. Neither fatty infiltration of the supraspinatus and subscapularis muscles nor glenohumeral osteoarthritis progressed significantly. CONCLUSIONS: At an average of 7.6 years, the clinical outcomes after structural failure of rotator cuff repairs remained significantly improved over the preoperative state in terms of pain, function, strength, and patient satisfaction. Overall, the reruptures that had been present at 3.2 years did not increase in size. We also found that reruptures of the supraspinatus that had been smaller than 400 mm(2) had the potential to heal.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: To compare the outcome of arthroscopic lysis and lavage of TMJ with internal derangement of Wilkes stages II, III, IV, and V. STUDY DESIGN: Arthroscopic lysis and lavage was performed in 45 TMJ of 39 patients with internal derangement. The cases were divided into 4 groups corresponding to Wilkes stages II, III, IV, and V. Two parameters were compared pre- and postoperatively: pain and mouth opening. Statistical significance was determined using the chi(2) test. RESULTS: Overall success rate was 86.7% (Wilkes stage II 90.9%, Wilkes stage III 92.3%, Wilkes stage IV 84.6%, Wilkes stage V 75%). There were no statistically significant differences between the success rates for Wilkes stages II, III, IV, and V. CONCLUSION: Arthroscopic lysis and lavage should be performed as a standard operation for internal derangement of the TMJ after failure of conservative treatment in all Wilkes stages.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Recently recommended treatment modalities for prosthetic joint infection (PJI) were evaluated. METHODS: A retrospective cohort analysis of 68 patients with PJI of hip or knee who were treated from 1995 through 2004 was conducted at the University Hospital Bern (Bern, Switzerland). RESULTS: A 2-stage exchange was the most frequent (75.0%) surgical strategy, followed by retention and debridement (17.6%), 1-stage exchange (5.9%), and resection arthroplasty or suppressive antimicrobial treatment (1.5%). The chosen strategy was in 88% agreement with the recommendations. Adherence was only 17% for retention and debridement and was 0% for 1-stage exchange. Most PJIs (84%) were treated with an adequate or partially adequate antimicrobial regimen. Recurrence-free survival was observed in 51.5% of PJI episodes after 24 months of follow-up. The risk of treatment failure was significantly higher for PJI treated with a surgical strategy other than that recommended (hazard ratio, 2.34; 95% confidence interval, 1.10-4.70; P = .01) and for PJIs treated with antibiotics not corresponding to recommendations (hazard ratio, 3.45; confidence interval, 1.50-7.60; P = .002). Other risk factors associated with lack of healing were a high infection score at the time of diagnosis (hazard ratio, 1.29; 95% confidence interval, 1.10-1.40; P < .001) and presence of a sinus tract (hazard ratio, 2.35; 95% confidence interval, 1.10-5.0; P = .02). CONCLUSIONS: Our study demonstrates the value of current treatment recommendations. Inappropriate choice of conservative surgical strategies (such as debridement and retention) and inadequate antibiotic treatment are associated with failure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Vertebral compression fracture is a common medical problem in osteoporotic individuals. The quantitative computed tomography (QCT)-based finite element (FE) method may be used to predict vertebral strength in vivo, but needs to be validated with experimental tests. The aim of this study was to validate a nonlinear anatomy specific QCT-based FE model by using a novel testing setup. Thirty-seven human thoracolumbar vertebral bone slices were prepared by removing cortical endplates and posterior elements. The slices were scanned with QCT and the volumetric bone mineral density (vBMD) was computed with the standard clinical approach. A novel experimental setup was designed to induce a realistic failure in the vertebral slices in vitro. Rotation of the loading plate was allowed by means of a ball joint. To minimize device compliance, the specimen deformation was measured directly on the loading plate with three sensors. A nonlinear FE model was generated from the calibrated QCT images and computed vertebral stiffness and strength were compared to those measured during the experiments. In agreement with clinical observations, most of the vertebrae underwent an anterior wedge-shape fracture. As expected, the FE method predicted both stiffness and strength better than vBMD (R2 improved from 0.27 to 0.49 and from 0.34 to 0.79, respectively). Despite the lack of fitting parameters, the linear regression of the FE prediction for strength was close to the 1:1 relation (slope and intercept close to one (0.86 kN) and to zero (0.72 kN), respectively). In conclusion, a nonlinear FE model was successfully validated through a novel experimental technique for generating wedge-shape fractures in human thoracolumbar vertebrae.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mixture modeling is commonly used to model categorical latent variables that represent subpopulations in which population membership is unknown but can be inferred from the data. In relatively recent years, the potential of finite mixture models has been applied in time-to-event data. However, the commonly used survival mixture model assumes that the effects of the covariates involved in failure times differ across latent classes, but the covariate distribution is homogeneous. The aim of this dissertation is to develop a method to examine time-to-event data in the presence of unobserved heterogeneity under a framework of mixture modeling. A joint model is developed to incorporate the latent survival trajectory along with the observed information for the joint analysis of a time-to-event variable, its discrete and continuous covariates, and a latent class variable. It is assumed that the effects of covariates on survival times and the distribution of covariates vary across different latent classes. The unobservable survival trajectories are identified through estimating the probability that a subject belongs to a particular class based on observed information. We applied this method to a Hodgkin lymphoma study with long-term follow-up and observed four distinct latent classes in terms of long-term survival and distributions of prognostic factors. Our results from simulation studies and from the Hodgkin lymphoma study demonstrated the superiority of our joint model compared with the conventional survival model. This flexible inference method provides more accurate estimation and accommodates unobservable heterogeneity among individuals while taking involved interactions between covariates into consideration.^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Medial penetration of the helical blade into the hip joint after fixation of trochanteric fractures using the proximal femur nail antirotation (PFN-A) is a potential failure mode. In low demand patients a blade exchange with cement augmentation may be an option if conversion to total hip arthroplasty is unfeasible to salvage the cut-through. This article describes a technique to avoid intraarticular cement leakage using a cement plug to close the defect in the femoral head caused by the cut-through.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Bibliography: leaves 21-23.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, fault-tolerant control of redundant planar serial manipulators has been investigated experimentally via an offline method called psuedo-inverse reconfiguration method. Minimizing the end-effector's velocity jump via an optimal mapping of joint failures into healthy joints velocity space can be regarded as the main contribution of this reconfiguration approach. This algorithm has been simulated and implemented on a four-link serial manipulator named as TaArm. It should be mentioned that for simulation and practical tests, C++ programming language in QtCreator environment has been used which provided high computational speed. Two scenarios has been selected for simulation and implementation studies and results shows that the algorithm considerably removes the velocity jump of the end-effector in both simulation and experimetal studies.