999 resultados para joint angles


Relevância:

60.00% 60.00%

Publicador:

Resumo:

There has been a significant increase in the incidence of musculoskeletal disorders (MSD) and the costs associated with these are predicted to increase as the popularity of computer use increases at home, school and work. Risk factors have been identified in the adult population but little is known about the risk factors for children and youth. Research has demonstrated that they are not immune to this risk and that they are self reporting the same pain as adults. The purpose of the study was to examine children’s postures while working at computer workstations under two conditions. One was at an ergonomically adjusted children’s workstation while the second was at an average adult workstation. A Polhemus Fastrak™ system was used to record the children’s postures and joint and segment angles were quantified. Results of the study showed that children reported more discomfort and effort at the adult workstation. Segment and joint angles showed significant differences through the upper limb at the adult workstation. Of significance was the strategy of shoulder abduction and flexion that the children used in order to place their hand on the mouse. Ulnar deviation was also greater at the adult workstation as was neck extension. All of these factors have been identified in the literature as increasing the risk for injury. A comparison of the children’s posture while playing at the children’s workstation verses the adult workstation, showed that the postural angles assumed by the children at an adult workstation exceeded the Occupational Safety and Health Association (OSHA) recommendations. Further investigation is needed to increase our knowledge of MSD in children as their potential for long term damage has yet to be determined.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Although a lowered medial longitudinal arch has been cited as a causal factor in plantar fasciitis, there is little experimental evidence linking arch motion to the pathogenesis of the condition. This study investigated the sagittal movement of the arch in subjects with and without plantar fasciitis during gait. Methods: Digital fluoroscopy was used to acquire dynamic lateral radiographs from 10 subjects with unilateral plantar fasciitis and 10 matched control subjects. The arch angle and the first metatarsophalangeal joint angle were digitized and their respective maxima recorded. Sagittal movement of the arch was defined as the angular change between heel strike and the maximum arch angle observed during the stance phase of gait. The-thickness of the proximal plantar fascia was determined from sagittal sonograms of both feet. ANOVA models were used to identify differences between limbs with respect to each dependent variable. Relationships between arch movement and fascial thickness were investigated using correlations. Results: There was no significant difference in either the movement or maximum arch angle between limbs. However, subjects with plantar fasciitis were found to have a larger metatarsophalangeal joint angle than controls (P < 0.05). Whereas the symptomatic and asymptomatic plantar fascia were thicker than those of control feet (P < 0.05), significant correlations were noted between fascial thickness and peak arch and metatarsophalangeal joint angles (P < 0.05) in the symptomatic limb only. Conclusions: Neither abnormal shape nor movement of the arch are associated with chronic plantar fasciitis. However, arch mechanics may influence the severity of plantar fasciitis once the condition is present. Digital flexion, in contrast, has a protective role in what might be a bilateral disease process.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

There has been a significant increase in the incidence of musculoskeletal disorders (MSD) and the costs associated with these are predicted to increase as the popularity of computer use increases at home, school and work. Risk factors have been identified in the adult population but little is known about the risk factors for children and youth. Research has demonstrated that they are not immune to this risk and that they are self reporting the same pain as adults. The purpose of the study was to examine children’s postures while working at computer workstations under two conditions. One was at an ergonomically adjusted children’s workstation while the second was at an average adult workstation. A Polhemus Fastrak™ system was used to record the children’s postures and joint and segment angles were quantified. Results of the study showed that children reported more discomfort and effort at the adult workstation. Segment and joint angles showed significant differences through the upper limb at the adult workstation. Of significance was the strategy of shoulder abduction and flexion that the children used in order to place their hand on the mouse. Ulnar deviation was also greater at the adult workstation as was neck extension. All of these factors have been identified in the literature as increasing the risk for injury. A comparison of the children’s posture while playing at the children’s workstation verses the adult workstation, showed that the postural angles assumed by the children at an adult workstation exceeded the Occupational Safety and Health Association (OSHA) recommendations. Further investigation is needed to increase our knowledge of MSD in children as their potential for long term damage has yet to be determined.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

New motor rehabilitation therapies include virtual reality (VR) and robotic technologies. In limb rehabilitation, limb posture is required to (1) provide a limb realistic representation in VR games and (2) assess the patient improvement. When exoskeleton devices are used in the therapy, the measurements of their joint angles cannot be directly used to represent the posture of the patient limb, since the human and exoskeleton kinematic models differ. In response to this shortcoming, we propose a method to estimate the posture of the human limb attached to the exoskeleton. We use the exoskeleton joint angles measurements and the constraints of the exoskeleton on the limb to estimate the human limb joints angles. This paper presents (a) the mathematical formulation and solution to the problem, (b) the implementation of the proposed solution on a commercial exoskeleton system for the upper limb rehabilitation, (c) its integration into a rehabilitation VR game platform, and (d) the quantitative assessment of the method during elbow and wrist analytic training. Results show that this method properly estimates the limb posture to (i) animate avatars that represent the patient in VR games and (ii) obtain kinematic data for the patient assessment during elbow and wrist analytic rehabilitation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Robot-Assisted Rehabilitation (RAR) is relevant for treating patients affected by nervous system injuries (e.g., stroke and spinal cord injury) -- The accurate estimation of the joint angles of the patient limbs in RAR is critical to assess the patient improvement -- The economical prevalent method to estimate the patient posture in Exoskeleton-based RAR is to approximate the limb joint angles with the ones of the Exoskeleton -- This approximation is rough since their kinematic structures differ -- Motion capture systems (MOCAPs) can improve the estimations, at the expenses of a considerable overload of the therapy setup -- Alternatively, the Extended Inverse Kinematics Posture Estimation (EIKPE) computational method models the limb and Exoskeleton as differing parallel kinematic chains -- EIKPE has been tested with single DOFmovements of the wrist and elbow joints -- This paper presents the assessment of EIKPEwith elbow-shoulder compoundmovements (i.e., object prehension) -- Ground-truth for estimation assessment is obtained from an optical MOCAP (not intended for the treatment stage) -- The assessment shows EIKPE rendering a good numerical approximation of the actual posture during the compoundmovement execution, especially for the shoulder joint angles -- This work opens the horizon for clinical studies with patient groups, Exoskeleton models, and movements types --

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Combining information on kinetics and kinematics of the trunk during gait is important for both clinical and research purposes, since it can help in better understanding the mechanisms behind changes in movement patterns in chronic low back pain patients. Although three-dimensional gait analysis has been used to evaluate chronic low back pain and healthy individuals, the reliability and measurement error of this procedure have not been fully established. The main purpose of this thesis is to gain a better understanding about the differences in the biomechanics of the trunk and lower limbs during gait, in patients and healthy individuals. To achieve these aims, three studies were developed. The first two, adopted a prospective design and focused on the reliability and measurement error of gait analysis. In these test-retest studies, chronic low back pain and healthy individuals were submitted to a gait assessment protocol, with two distinct evaluation moments, separated by one week. Gait data was collected using a 13-camera opto-electronic system and three force platforms. Data analysis included the computation of time-distance parameters, as well as the peak values for lower limb and trunk joint angles/moments. The third study followed a cross sectional design, where gait in chronic low back pain individuals was compared with matched controls. Step-to-step variability of the thoracic, lumbar and hips was calculated, and step-to-step deviations of these segments from their average pattern (residual rotations) were correlated to each other. The reliability studies in this thesis show that three-dimensional gait analysis is a reliable and consistent procedure for both chronic low back pain and healthy individuals. The results suggest varied reliability indices for multi-segment trunk joint angles, joint moments and time-distance parameters during gait, together with an acceptable level of error (particularly regarding sagittal plane). Our findings also show altered stride-to-stride variability of lumbar and thoracic segments and lower trunk joint moments in patients. These kinematic and kinetic results lend support to the notion that chronic low back pain individuals exhibit a protective movement strategy.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The reachable space of the hand has received significant interests in the past from relevant medical researchers and health professionals. The reachable space was often computed from the joint angles acquired from a motion capture system such as gloves or markers attached to each bone of the finger. However, the contact between the hand and device can cause difficulties particularly for hand with injuries, burns or experiencing certain dermatological conditions. This paper introduces an approach to find the reachable space of the hand in a non-contact measurement form utilizing the Leap Motion Controller. The approach is based on the analysis of each position in the motion path of the fingertip acquired by the Leap Motion Controller. For each position of the fingertip, the inverse kinematic problem was solved under the physiological multiple constraints of the human hand to find a set of all possible configurations of three finger joints. Subsequently, all the sets are unified to form a set of all possible configurations specific for that motion. Finally, a reachable space is computed from the configuration corresponding to the complete extension and the complete flexion of the finger joint angles in this set.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The standard treatment for a non-union of the hallux metatarsophalangeal joint fusion has been to revise the fusion. Revision fusion is technically more demanding, often involving bone grafting, more substantial fixation and prolonged period of immobilization postoperatively. We present data to suggest that removal of hardware and debridement alone is an alternative treatment option. ---------- MATERIALS AND METHODS: A case note review identified patients with a symptomatic non-union after hallux metatarsophalangeal joint (MTPJ) fusion. It is our practice to offer these patients revision fusion or removal of hardware and debridement. For the seven patients that chose hardware removal and were left with a pseudarthrosis, a matched control group was selected from patients who had had successful fusions. Three outcome scores were used. Hallux valgus and dorsiflexion angles were recorded.---------- RESULTS: One hundred thirty-nine hallux MTPJ arthrodeses were carried out. Fourteen non-unions were identified. The rate of non-union in males and following previous hallux MTPJ surgery was 19% and 24%, respectively. In females undergoing a primary MTPJ fusion, the rate was 2.4%. Twelve non-union patients were reviewed at 27 months (mean). Eleven patients had elected to undergo removal of hardware and debridement. Four patients with pseudarthrosis were unhappy with the results and proceeded to either revision fusion or MTPJ replacement. Seven non-union patients, who had removal of hardware alone, had outcome scores marginally worse compared to those with successful fusions.---------- CONCLUSION: Removal of hardware alone is a reasonable option to offer as a relatively minor procedure following a failed arthrodesis of the first MTPJ. This must be accepted on the proviso that in this study four out of 11 (36%) patients proceeded to a revision first MTPJ fusion or first MTPJ replacement. We also found that the rate of non-union in primary first MTPJ fusion was significantly higher in males and those patients who had undergone previous surgery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The relationship between coronal knee laxity and the restraining properties of the collateral ligaments remains unknown. This study investigated correlations between the structural properties of the collateral ligaments and stress angles used in computer-assisted total knee arthroplasty (TKA), measured with an optically based navigation system. Ten fresh-frozen cadaveric knees (mean age: 81 ± 11 years) were dissected to leave the menisci, cruciate ligaments, posterior joint capsule and collateral ligaments. The resected femur and tibia were rigidly secured within a test system which permitted kinematic registration of the knee using a commercially available image-free navigation system. Frontal plane knee alignment and varus-valgus stress angles were acquired. The force applied during varus-valgus testing was quantified. Medial and lateral bone-collateral ligament-bone specimens were then prepared, mounted within a uni-axial materials testing machine, and extended to failure. Force and displacement data were used to calculate the principal structural properties of the ligaments. The mean varus laxity was 4 ± 1° and the mean valgus laxity was 4 ± 2°. The corresponding mean manual force applied was 10 ± 3 N and 11 ± 4 N, respectively. While measures of knee laxity were independent of the ultimate tensile strength and stiffness of the collateral ligaments, there was a significant correlation between the force applied during stress testing and the instantaneous stiffness of the medial (r = 0.91, p = 0.001) and lateral (r = 0.68, p = 0.04) collateral ligaments. These findings suggest that clinicians may perceive a rate of change of ligament stiffness as the end-point during assessment of collateral knee laxity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Adolescent Idiopathic Scoliosis is the most common type of spinal deformity, and whilst the risk of progression appears to be biomechanically mediated (larger deformities are more likely to progress), the detailed biomechanical mechanisms driving progression are not well understood. Gravitational forces in the upright position are the primary sustained loads experienced by the spine. In scoliosis they are asymmetrical, generating moments about the spinal joints which may promote asymmetrical growth and deformity progression. Using 3D imaging modalities to estimate segmental torso masses allows the gravitational loading on the scoliotic spine to be determined. The resulting distribution of joint moments aids understanding of the mechanics of scoliosis progression. Methods Existing low-dose CT scans were used to estimate torso segment masses and joint moments for 20 female scoliosis patients. Intervertebral joint moments at each vertebral level were found by summing the moments of each of the torso segment masses above the required joint. Results The patients’ mean age was 15.3 years (SD 2.3; range 11.9 – 22.3 years); mean thoracic major Cobb angle 52° (SD 5.9°; range 42°-63°) and mean weight 57.5 kg (SD 11.5 kg; range 41 – 84.7 kg). Joint moments of up to 7 Nm were estimated at the apical level. No significant correlation was found between the patients’ major Cobb angles and apical joint moments. Conclusions Patients with larger Cobb angles do not necessarily have higher joint moments, and curve shape is an important determinant of joint moment distribution. These findings may help to explain the variations in progression between individual patients. This study suggests that substantial corrective forces are required of either internal instrumentation or orthoses to effectively counter the gravity-induced moments acting to deform the spinal joints of idiopathic scoliosis patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Regular zinc oxide (ZnO) tetrapods with a flat plane have been obtained on Si(1 0 0) substrate via the chemical vapour deposition approach. The x-ray diffraction result suggests that these tetrapods are all single crystals with a wurtzite structure that grow along the (0 0 0 1) direction and corresponding electron backscatter diffraction analysis reveals the crystal orientation of growth and exposed surface. Furthermore, we find some ZnO tetrapods with some legs off and the angles between every two legs are measured with the aid of scanning electron microscopy and image analysis, which benefit to reveal the structure of ZnO tetrapods joint. The structure model and growth mechanism of ZnO tetrapods are proposed. Besides, the stable model of the interface was obtained through the density-functional theory calculation and the energy needed to break the twin plane junction was calculated as 5.651 J m(-2).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A 1.55 mu m InGaAsP/InGaAsP multiple-quantum-well electro-absorption modulator (EAM) monolithically integrated with a distributed feedback laser (DFB) diode has been realized based on a novel butt-joint scheme by ultra-low metal-organic vapour phase epitaxy for the first time. The threshold current of 25 mA and an extinction ratio of more than 30 dB are obtained by using the novel structure. The beam divergence angles at the horizontal and vertical directions are as small as 19.3 degrees x 13 degrees, respectively, without a spot-size converter by undercutting the InGaAsP active region. The capacitance of the ridge waveguide device with a deep mesa buried by polyimide was reduced down to 0.30 pF.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

 The measurement of the range of hand joint movement is an essential part of clinical practice and rehabilitation. Current methods use three finger joint declination angles of the metacarpophalangeal, proximal interphalangeal and distal interphalangeal joints. In this paper we propose an alternate form of measurement for the finger movement. Using the notion of reachable space instead of declination angles has significant advantages. Firstly, it provides a visual and quantifiable method that therapists, insurance companies and patients can easily use to understand the functional capabilities of the hand. Secondly, it eliminates the redundant declination angle constraints. Finally, reachable space, defined by a set of reachable fingertip positions, can be measured and constructed by using a modern camera such as Creative Senz3D or built-in hand gesture sensors such as the Leap Motion Controller. Use of cameras or optical-type sensors for this purpose have considerable benefits such as eliminating and minimal involvement of therapist errors, non-contact measurement in addition to valuable time saving for the clinician. A comparison between using declination angles and reachable space were made based on Hume's experiment on functional range of movement to prove the efficiency of this new approach.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The evaluation of the knee joint behavior is fundamental in many applications, such as joint modeling, prosthesis and orthosis design. In-vitro tests are important in order to analyse knee behavior when simulating various loading conditions and studying physiology of the joint. A new test rig for in-vitro evaluation of the knee joint behavior is presented in this paper. It represents the evolution of a previously proposed rig, designed to overcome its principal limitations and to improve its performances. The design procedure and the adopted solution in order to satisfy the specifications are presented here. Thanks to its 6-6 Gough-Stewart parallel manipulator loading system, the rig replicates general loading conditions, like daily actions or clinical tests, on the specimen in a wide range of flexion angles. The restraining actions of knee muscles can be simulated when active actions are simulated. The joint motion in response to the applied loads, guided by passive articular structures and muscles, is permitted by the characteristics of the loading system which is force controlled. The new test rig guarantees visibility so that motion can be measured by an optoelectronic system. Furthermore, the control system of the new test rig allows the estimation of the contribution of the principal leg muscles in guaranteeing the equilibrium of the joint by the system for muscle simulation. Accuracy in positioning is guaranteed by the designed tibia and femur fixation systems,which allow unmounting and remounting the specimen in the same pose. The test rig presented in this paper permits the analysis of the behavior of the knee joint and comparative analysis on the same specimen before and after surgery, in a way to assess the goodness of prostheses or surgical treatments.