990 resultados para international insertion


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The lateral pterygoid muscle, more specifically its superior head, as we know, is closely related to the temporomandibular joint (TMJ). Particularly in children, in contrast with what was observed in adults, these joints have been rarely studied, by the anatomic functional aspect, little knowing about its functions in the embryonic and fetal periods. We used, in this work, 12 fetuses ranging in age from 16 to 39 weeks of intrauterine life, where we observed that the superior head of the lateral pterygoid muscle is inserted in the disc and in the articular capsule, in all age groups studied, and also, that the fibers and the thickness of the articular disc is, as well as the articular capsule suffer modifications in accordance with the period of development. © 2007 Sociedad Chilena de Anatom•br>.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To evaluate the marginal microleakage in enamel and dentin/cementum walls in preparations with a high C-factor, using 3 resin composite insertion techniques. The null hypothesis was that there is no difference among the 3 resin composite insertion techniques. Method and Materials: Standardized Class 5 cavities were prepared in the lingual and buccal aspects of 30 caries-free, extracted third molars. The prepared teeth were randomly assigned to 3 groups: (1) oblique incremental placement technique, (2) horizontal incremental placement technique, and (3) bulk insertion (single increment). The preparations were restored with a 1-bottle adhesive (Single Bond, 3M ESPE) and microhybrid resin composite (Z100, 3M ESPE). Specimens were isolated with nail varnish except for a 2-mm-wide rim around the restoration and thermocycled (1,000 thermal cycles, 5°C/55°C; 30-second dwell time). The specimens were immersed in an aqueous solution of 50 wt% silver nitrate for 24 hours, followed by 8 hours in a photo-developing solution and evaluated for microleakage using an ordinal scale of 0 to 4. The microleakage scores obtained from occlusal and gingival walls were analyzed with Wilcoxon and Kruskal-Wallis nonparametric tests. Results: The null hypothesis was accepted. The horizontal incremental placement technique, the oblique incremental technique, and bulk insertion resulted in statistically similar enamel and dentin microleakage scores. Conclusion: Neither the incremental techniques nor the bulk placement technique were capable of eliminating the marginal microleakage in preparations with a high C-factor.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of the study was to evaluate mechanical behavior of implants inserted in three substrates, by measuring the pullout strength and the relative stiffness. 32 implants (Master Porous-Conexao, cylindrical, external hexagon, and surface treatment) were divided into 4 groups (n = 8): pig rib bone, polyurethane Synbone, polyurethane Nacional 40 PCF, and pinus wood. Implants were installed with the exact distance of 5 mm of another implant. The insertion torque (N·cm) was quantified using the digital Kratos torque meter and the pullout test (N) was performed by an axial traction force toward the long axis of the implant (2 min/mm) through mount implant devices attached to a piece adapted to a load cell of 200 Kg of a universal testing machine (Emic DL10000). Data of insertion torque and maximum pullout force were submitted to one-way ANOVA and Bonferroni tests (α = 0.05). Polyurethane Nacional 40 PCF and pinus wood showed the highest values of insertion torque and pullout force, with significant statistical difference (P < 0.05) with other groups. The analysis showed stiffness materials with the highest values for primary stability. © 2013 Nathalia Ferraz Oliscovicz et al.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mini-implant insertion requires accurate surgical technique. This study shows an insertion technique using only tooth crown references; its scientific basis is evaluated radiographically. The sample consisted of 213 inter-radicular septa, evaluated in 53 bitewing radiographs. The proximal contour of adjacent tooth crowns was used to define septum width. The midpoint of the septum width was linked to the interdental contact point to determine septum midline. The distances from septum midline to "mesial and distal teeth were measured to evaluate the septum midline centralization degree in two different septum heights. The difference between mesial and distal distances represented the septum midline deviation degree. The mesial and distal distances were compared by t-tests, and the septum midline deviation was correlated with septum height using Pearson's correlation test. The mesial and distal distances were not statistically different in the midpoint of the septum height, but they were different at the apical septum height. There was a moderate correlation (r = 0.45) between septum midline deviation and septum height. The tooth crown references evaluated on interproximal radiographs determine a high centralization degree of the septum midline on which the insertion site could be defined. The greater centralization degree was observed at the coronal septum area.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Body packing is used for international drug transport, immediate drug concealment during a police searching or introducing drugs inside prisons. Despite the high level of specialization of dealers who have started to manufacture more complex packs, up to 5% of patients could develop intoxication due to pack rupture. Bowel obstruction is another acute complication. Case presentation: A 27-year-old black male patient was sent to the hospital by court order for clinical evaluation and toxicological examination. The patient was conscious, oriented, had good color, normal arterial pressure and heart rate, and no signs of acute intoxication. Abdominal examination revealed discrete pain upon deep palpation and a small mass in the left iliac fossa. A plain abdominal radiograph revealed several oval structures located in the rectum and sigmoid. Fasting and a 50 g dose of activated charcoal every six hours were prescribed. After three days, the patient spontaneously evacuated 28 cocaine packs. Conclusion: Adequate clinical management and prompt identification of potential complications are of fundamental importance in dealing with body packing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report a serious bleeding complication due to injury of the corona mortis following insertion of a transvaginal tape, TVT-Secur™ (Ethicon Women's Health, Sommerville, NJ, USA).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To estimate the applicability of potential sites for insertion of orthodontic mini-implants (OMIs) by a systematic review of studies that used computed tomography (CT) or cone beam CT to evaluate anatomical bone quality and quantity parameters, such as bone thickness, available space, and bone density.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Patients with upper aerodigestive tract (UAT) cancers often suffer from malnutrition and compromised functional ability. We compared clinical outcome with percutaneous endoscopic gastrostomy (PEG) tube feeding begun at two different time points. The records of 151 patients with UAT carcinomas were reviewed retrospectively. We included patients undergoing radical radiochemotherapy and PEG tube feeding. Subjects were evaluated before PEG insertion and at the end of the treatment. Patients (n=15, 100%) were divided into two groups according to the presence (group A) or absence (group B) of mucositis. Group A (51.7% of patients) received early PEG: before or within 2 wk of radiotherapy. Group B (48.3%) received delayed PEG: between 2 wk and 3 mo after the start of radiotherapy. Mean weight loss was 1.03 kg in group A vs. 4.0 kg in group B, P=0.004. Treatment interruptions were significantly (P=0.01) more common in group B. Early PEG placement at the beginning of radiochemotherapy in patients with UAT tumors maintains the patient's nutritional state and reduces treatment interruptions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A major component of minimally invasive cochlear implantation is atraumatic scala tympani (ST) placement of the electrode array. This work reports on a semiautomatic planning paradigm that uses anatomical landmarks and cochlear surface models for cochleostomy target and insertion trajectory computation. The method was validated in a human whole head cadaver model (n = 10 ears). Cochleostomy targets were generated from an automated script and used for consecutive planning of a direct cochlear access (DCA) drill trajectory from the mastoid surface to the inner ear. An image-guided robotic system was used to perform both, DCA and cochleostomy drilling. Nine of 10 implanted specimens showed complete ST placement. One case of scala vestibuli insertion occurred due to a registration/drilling error of 0.79 mm. The presented approach indicates that a safe cochleostomy target and insertion trajectory can be planned using conventional clinical imaging modalities, which lack sufficient resolution to identify the basilar membrane.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Assessing video quality is a complex task. While most pixel-based metrics do not present enough correlation between objective and subjective results, algorithms need to correspond to human perception when analyzing quality in a video sequence. For analyzing the perceived quality derived from concrete video artifacts in determined region of interest we present a novel methodology for generating test sequences which allow the analysis of impact of each individual distortion. Through results obtained after subjective assessment it is possible to create psychovisual models based on weighting pixels belonging to different regions of interest distributed by color, position, motion or content. Interesting results are obtained in subjective assessment which demonstrates the necessity of new metrics adapted to human visual system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Microneedles (MNs) are emerging devices that can be used for the delivery of drugs at specific locations1. Their performance is primarily judged by different features and the penetration through tissue is one of the most important aspects to evaluate. For detailed studies of MN performance different kind of in-vitro, exvivo and in-vivo tests should be performed. The main limitation of some of these tests is that biological tissue is too heterogeneous, unstable and difficult to obtain. In addition the use of biological materials sometimes present legal issues. There are many studies dealing with artificial membranes for drug diffusion2, but studies of artificial membranes for Microneedle mechanical characterization are scarce3. In order to overcome these limitations we have developed tests using synthetic polymeric membranes instead of biological tissue. The selected artificial membrane is homogeneous, stable, and readily available. This material is mainly composed of a roughly equal blend of a hydrocarbon wax and a polyolefin and it is commercially available under the brand name Parafilm®. The insertion of different kind of MN arrays prepared from crosslinked polymers were performed using this membrane and correlated with the insertion of the MN arrays in ex-vivo neonatal porcine skin. The insertion depth of the MNs was evaluated using Optical coherence tomography (OCT). The implementation of MN transdermal patches in the market can be improved by make this product user-friendly and easy to use. Therefore, manual insertion is preferred to other kind of procedures. Consequently, the insertion studies were performed in neonatal porcine skin and the artificial membrane using a manual insertion force applied by human volunteers. The insertion studies using manual forces correlated very well with the same studies performed with a Texture Analyzer equipment. These synthetic membranes seem to mimic closely the mechanical properties of the skin for the insertion of MNs using different methods of insertion. In conclusion, this artificial membrane substrate offers a valid alternative to biological tissue for the testing of MN insertion and can be a good candidate for developing a reliable quality control MN insertion test.