996 resultados para installation performance


Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this study, the performance, yield and characteristics of a 16 year old photovoltaic (PV) system installation have been investigated. The technology, BP Saturn modules which were steel-blue polycrystalline silicon cells are no longer in production. A bespoke monitoring system has been designed to monitor the characteristics of 6 refurbished strings, of 18 modules connected in series. The total output of the system is configured to 6.5 kWp (series to parallel configuration). In addition to experimental results, the performance ratio (PR) of known values was simulated using PVSyst, a simulation software package. From calculations using experimental values, the PV system showed approximately 10% inferior power outputs to what would have been expected as standard test conditions. However, efficiency values in comparison to standard test conditions and the performance ratio (w75% from PVSyst simulations) over the past decade have remained practically the same. This output though very relevant to the possible performance and stability of aging cells, requires additional parametric studies to develop a more robust argument. The result presented in this paper is part of an on-going investigation into PV system aging effects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Located on the Annapurna trekking trail in Nepal, Siurung is a remote mountain village where outside influences are almost non-existent. The thermal comfort levels of a recently-constructed kindergarten are well below international standards because of the climate and poor building envelope. A TRNSYS model of the kindergarten has been used to predict the current occupant comfort levels and subsequently determine the most effective way to alter the traditional construction methods to improve comfort levels. Improvements investigated were: reduced air infiltration, roof and wall insulation (separately and together), installation of a smokeless stove and a combination of all strategies.The model predicted that in the current building the PMV ranges from -1.94 in October to - 0.99 in July. It also predicted that the current PPD (%) ranges from 100 in January to 26 in July. With the combination of strategies, the predicted PMV values were all improved to between -1.08 and +0.34, and the PPD values of all months except January were reduced to below 10%. When improving the comfort levels of an existing school, reducing air infiltration, adding roof insulation and installing a smokeless stove are the most effective strategies. When constructing a new school, however, reducing air infiltration and adding insulation to the walls and roof are the most effective and feasible strategies. If a smokeless stove can be afforded and transported to the site, it is recommended that one be installed as it provides a more significant improvement than any other single strategy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Os fatores de risco para instalação de lesões do esporte têm sido pesquisados no sentido de facilitar o entendimento sobre o assunto. Contudo, para altos níveis de performance, nos eventos de pista e campo do atletismo, são escassos os documentos que abordam o tema. Assim, a partir da possibilidade de reunir informações sobre a condição descrita, objetivou-se com o presente estudo a exploração de fatores de risco para lesões desportivas no atletismo, a partir de inquérito aplicado a atletas da elite mundial da modalidade. A população foi composta por 60 homens e 60 mulheres alocados em grupos conforme a especificidade de sua modalidade (velocidade, resistência, arremessos e saltos). Realizou-se entrevista utilizando-se de inquérito de morbidade referida, abordando questões sobre variáveis antropométricas e de treinamento, assim como lesões. Utilizou-se a técnica da análise de variância paramétrica para as variáveis antropométricas (idade, peso, estatura) e da técnica da análise de variância não paramétrica em relação às variáveis de treinamento (anos de treinamento e horas semanais). Para associação entre momento de lesão e especialidades, utilizou-se do teste de Goodman em nível de 5% de significância. Os resultados mostraram que houve elevada freqüência de lesões na modalidade em ambos os sexos. As taxas de lesão por atleta entrevistado foram de 0,92 (velocidade), 1,08 (resistência), 1,22 (saltos) e 1,20 (arremessos). Não houve diferença estatisticamente significante para as variáveis antropométricas e de treinamento em relação às provas, com exceção dos saltadores, que apresentaram diferenças para estatura e tempo de treinamento; nesse caso, os acometidos são mais altos ou praticam atletismo há menos tempo (P < 0,05). Concluiu-se que, para população estudada, o risco de lesão é acentuado, mas sem relação entre variáveis e presença de agravos, salvo para especialistas em provas de saltos, que apresentaram estatura e tempo de treinamento como fatores predisponentes à lesão.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The CMS Hadron Calorimeter in the barrel, endcap and forward regions is fully commissioned. Cosmic ray data were taken with and without magnetic field at the surface hall and after installation in the experimental hall, hundred meters underground. Various measurements were also performed during the few days of beam in the LHC in September 2008. Calibration parameters were extracted, and the energy response of the HCAL determined from test beam data has been checked. © 2010 IOP Publishing Ltd and SISSA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the early 1970 the community has started to realize that have as a main principle the industry one, with the oblivion of the people and health conditions and of the world in general, it could not be a guideline principle. The sea, as an energy source, has the characteristic of offering different types of exploitation, in this project the focus is on the wave energy. Over the last 15 years the Countries interested in the renewable energies grew. Therefore many devices have came out, first in the world of research, then in the commercial one; these converters are able to achieve an energy transformation into electrical energy. The purpose of this work is to analyze the efficiency of a new wave energy converter, called WavePiston, with the aim of determine the feasibility of its actual application in different wave conditions: from the energy sea state of the North Sea, to the more quiet of the Mediterranean Sea. The evaluation of the WavePiston is based on the experimental investigation conducted at the University of Aalborg, in Denmark; and on a numerical modelling of the device in question, to ascertain its efficiency regardless the laboratory results. The numerical model is able to predict the laboratory condition, but it is not yet a model which can be used for any installation, in fact no mooring or economical aspect are included yet. È dai primi anni del 1970 che si è iniziato a capire che il solo principio dell’industria con l’incuranza delle condizioni salutari delle persone e del mondo in generale non poteva essere un principio guida. Il mare, come fonte energetica, ha la caratteristica di offrire diverse tipologie di sfruttamento, in questo progetto è stata analizzata l’energia da onda. Negli ultimi 15 anni sono stati sempre più in aumento i Paesi interessati in questo ambito e di conseguenza, si sono affacciati, prima nel mondo della ricerca, poi in quello commerciale, sempre più dispositivi atti a realizzare questa trasformazione energetica. Di tali convertitori di energia ondosa ne esistono diverse classificazioni. Scopo di tale lavoro è analizzare l’efficienza di un nuovo convertitore di energia ondosa, chiamato WavePiston, al fine si stabilire la fattibilità di una sua reale applicazione in diverse condizioni ondose: dalle più energetiche del Mare del Nord, alle più quiete del Mar Mediterraneo. La valutazione sul WavePiston è basata sullo studio sperimentale condotto nell’Università di Aalborg, in Danimarca; e su di una modellazione numerica del dispositivo stesso, al fine di conoscerne l’efficienza a prescindere dalla possibilità di avere risultati di laboratorio. Il modello numerico è in grado di predirre le condizioni di laboratorio, ma non considera ancora elementi come gli ancoraggi o valutazione dei costi.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Experience is lacking with mineral scaling and corrosion in enhanced geothermal systems (EGS) in which surface water is circulated through hydraulically stimulated crystalline rocks. As an aid in designing EGS projects we have conducted multicomponent reactive-transport simulations to predict the likely characteristics of scales and corrosion that may form when exploiting heat from granitoid reservoir rocks at ∼200 °C and 5 km depth. The specifications of an EGS project at Basel, Switzerland, are used to constrain the model. The main water–rock reactions in the reservoir during hydraulic stimulation and the subsequent doublet operation were identified in a separate paper (Alt-Epping et al., 2013b). Here we use the computed composition of the reservoir fluid to (1) predict mineral scaling in the injection and production wells, (2) evaluate methods of chemical geothermometry and (3) identify geochemical indicators of incipient corrosion. The envisaged heat extraction scheme ensures that even if the reservoir fluid is in equilibrium with quartz, cooling of the fluid will not induce saturation with respect to amorphous silica, thus eliminating the risk of silica scaling. However, the ascending fluid attains saturation with respect to crystalline aluminosilicates such as albite, microcline and chlorite, and possibly with respect to amorphous aluminosilicates. If no silica-bearing minerals precipitate upon ascent, reservoir temperatures can be predicted by classical formulations of silica geothermometry. In contrast, Na/K concentration ratios in the production fluid reflect steady-state conditions in the reservoir rather than albite–microcline equilibrium. Thus, even though igneous orthoclase is abundant in the reservoir and albite precipitates as a secondary phase, Na/K geothermometers fail to yield accurate temperatures. Anhydrite, which is present in fractures in the Basel reservoir, is predicted to dissolve during operation. This may lead to precipitation of pyrite and, at high exposure of anhydrite to the circulating fluid, of hematite scaling in the geothermal installation. In general, incipient corrosion of the casing can be detected at the production wellhead through an increase in H2(aq) and the enhanced precipitation of Fe-bearing aluminosilicates. The appearance of magnetite in scales indicates high corrosion rates.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Occupational exposures to organic solvents, specifically acetonitrile and methanol, have the potential to cause serious long-term health effects. In the laboratory, these solvents are used extensively in protocols involving the use of high performance liquid chromatography (HPLC). Operators of HPLC equipment may be potentially exposed to these organic solvents when local exhaust ventilation is not employed properly or is not available, which can be the case in many settings. The objective of this research was to characterize the various sites of vapor release in the HPLC process and then to determine the relative influence of a novel vapor recovery system on the overall exposure to laboratory personnel. The effectiveness of steps to reduce environmental solvent vapor concentrations was assessed by measuring exposure levels of acetonitrile and methanol before and after installation of the vapor recovery system. With respect to acetonitrile, the concentration was not statistically significant with p=0.938; moreover, exposure after the intervention was actually higher than prior to intervention. With respect to methanol, the concentration was not statistically significant with p=0.278. This indicates that the exposure to methanol after the intervention was not statistically significantly higher or lower than prior to intervention. Thus, installation of the vapor recovery device did not result in statistically significant reduction in exposures in the settings encountered, and acetonitrile actually increased significantly.^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Concentrating Solar Power (CSP) plants typically incorporate one or various auxiliary boilers operating in parallel to the solar field to facilitate start up operations, provide system stability, avoid freezing of heat transfer fluid (HTF) and increase generation capacity. The environmental performance of these plants is highly influenced by the energy input and the type of auxiliary fuel, which in most cases is natural gas (NG). Replacing the NG with biogas or biomethane (BM) in commercial CSP installations is being considered as a means to produce electricity that is fully renewable and free from fossil inputs. Despite their renewable nature, the use of these biofuels also generates environmental impacts that need to be adequately identified and quantified. This paper investigates the environmental performance of a commercial wet-cooled parabolic trough 50 MWe CSP plant in Spain operating according to two strategies: solar-only, with minimum technically viable energy non-solar contribution; and hybrid operation, where 12 % of the electricity derives from auxiliary fuels (as permitted by Spanish legislation). The analysis was based on standard Life Cycle Assessment (LCA) methodology (ISO 14040-14040). The technical viability and the environmental profile of operating the CSP plant with different auxiliary fuels was evaluated, including: NG; biogas from an adjacent plant; and BM withdrawn from the gas network. The effect of using different substrates (biowaste, sewage sludge, grass and a mix of biowaste with animal manure) for the production of the biofuels was also investigated. The results showed that NG is responsible for most of the environmental damage associated with the operation of the plant in hybrid mode. Replacing NG with biogas resulted in a significant improvement of the environmental performance of the installation, primarily due to reduced impact in the following categories: natural land transformation, depletion of fossil resources, and climate change. However, despite the renewable nature of the biofuels, other environmental categories like human toxicity, eutrophication, acidification and marine ecotoxicity scored higher when using biogas and BM.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the development of wave energy converters, the mooring system is a key component for a safe station-keeping and an important factor in the cost of the wave energy production. Generally, when designing a mooring system for a wave energy converter, two important conditions must be considered: (i) that the mooring system must be strong enough to limit the drifting motions, even in extreme waves, tidal and wind conditions and (ii) it must be compliant enough so that the impact on wave energy production can be minimised. It is frequently found that these two conditions are contradictory. The existing solutions mainly include the use of heavy chains, which create a catenary shaped mooring configuration, allowing limited flexibility within the mooring system, and hence very large forces may still be present on mooring lines and thus on anchors. This solution is normally quite expensive if the costs of the materials and installation are included. This paper presents a new solution to the mooring system for wave energy converters within the FP7 project, ‘GeoWAVE’, which is a project aiming to develop a new generation of the moorings system for minimising the loads on mooring lines and anchors, the impact on the device motions for power conversion, and the footprint if it is applicable, and meanwhile the new types of anchors are also addressed within the project. However this paper will focus on the new mooring system by presenting the wave tank test results of the Pelamis wave energy converter model and the new developed mooring system. It can be seen that the new generation of mooring system can significantly reduce the loads on mooring lines and anchors, and reduce the device excursions as a result of the new mooring system when compare to the conventional catenary mooring.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ground-source heat pump (GSHP) systems represent one of the most promising techniques for heating and cooling in buildings. These systems use the ground as a heat source/sink, allowing a better efficiency thanks to the low variations of the ground temperature along the seasons. The ground-source heat exchanger (GSHE) then becomes a key component for optimizing the overall performance of the system. Moreover, the short-term response related to the dynamic behaviour of the GSHE is a crucial aspect, especially from a regulation criteria perspective in on/off controlled GSHP systems. In this context, a novel numerical GSHE model has been developed at the Instituto de Ingeniería Energética, Universitat Politècnica de València. Based on the decoupling of the short-term and the long-term response of the GSHE, the novel model allows the use of faster and more precise models on both sides. In particular, the short-term model considered is the B2G model, developed and validated in previous research works conducted at the Instituto de Ingeniería Energética. For the long-term, the g-function model was selected, since it is a previously validated and widely used model, and presents some interesting features that are useful for its combination with the B2G model. The aim of the present paper is to describe the procedure of combining these two models in order to obtain a unique complete GSHE model for both short- and long-term simulation. The resulting model is then validated against experimental data from a real GSHP installation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Panoramic Sea Happening (After Kantor) is a 7 minute durational film that reimagines part of Tadeusz Kantor's original sea happenings from 1967 in a landscape in which the sea has retreated. The conductor of Kantor’s original performance is replaced with a sound object cast adrift on a beach in Dungeness (UK). The object plays back the sound of the sea into the landscape, which was performed live and then filmed from three distinct angles. The first angle mimics the position of the conductor in Kantor’s original happening, facing outwards into the horizon of the beach and recalls the image in Kantor’s work of a human figure undertaking the absurd task of orchestrating the sound of a gigantic expanse of water. The second angle exposes the machine itself and the large cone that amplifies the sound, reinforcing the isolation of the object. The third angle reveals a decommissioned nuclear power station and sound objects used as a warning system for the power plant. Dungeness is a location where the sea has been retreating from the land, leaving traces of human activity through the disused boat winches, abandoned cabins and the decommissioned nuclear buildings. It is a place in which the footprint of the anthropocene is keenly felt. The sound object is intended to act as an anthropomorphic figure, ghosting the original conductor and offering the sound of the sea back into the landscape through a wide mouthpiece, echoing Kantor’s own load hailer in the original sequence of sea happenings. It speculates on Kantor's theory of the bio-object, which proposed a symbiotic relationship between the human and the nonhuman object in performance, as a possible instrument to access a form of geologic imagination. In this configuration, the human itself is absent, but is evoked through the objects left behind. The sound object, helpless in a red dingy, might be thought of as a co-conspirator with the viewer, enabling a looking back to the past in a landscape of an inevitable future. The work was originally commissioned by the University of Kent in collaboration with the Polish Cultural Institute for the Symposium Kantorbury Kantorbury in Canterbury (UK) to mark the 100 years since Tadeusz Kantor’s birth (15 - 19 September 2015). It should be projected and requires stereo speakers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Au Québec, les drains installés dans les sols sableux-limoneux sont sensibles au colmatage par ensablement et/ou par ocre de fer. Dans le passé, les drains avec des pertuis inférieurs à 2 mm étaient utilisés au Québec avec un filtre tissé de 110 microns ou un filtre tricoté de 450 microns. Récemment, des drains avec des pertuis supérieurs à 2 mm ainsi qu’un filtre de 250 microns ont été introduits sur le marché mais n’ont jamais été testés. Le projet avait pour objectif de déterminer les vitesses auxquelles se feront l’ensablement et le colmatage ferrique pour différentes combinaisons de drains (pertuis de 1,8 mm et de 3 mm) et de filtres (110 μm, 250 μm et 450 μm) dans un sol sableux à Bécancour. Un dispositif expérimental en blocs complets (3) aléatoires a été utilisé. Les débits ont été mesurés à la sortie des drains de chaque parcelle et les hauteurs des nappes ont été mesurées avec un bulleur dans des puits d’observation. Le suivi du pH, du potentiel d’oxydoréduction et du contenu en Fe2+ a été réalisé dans l’eau de la nappe et celle des drains. Les drains excavés 13 mois après leur installation ne montrent que des traces de sédiments et de colmatage ferrique. Les niveaux de Fe2+ sont significativement plus faibles dans l’eau à la sortie des drains que dans l’eau de la nappe. Le processus de colmatage ferrique ne semble que commencer et son impact n’est pas mesurable au niveau des débits unitaires à la sortie des drains.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this thesis, tool support is addressed for the combined disciplines of Model-based testing and performance testing. Model-based testing (MBT) utilizes abstract behavioral models to automate test generation, thus decreasing time and cost of test creation. MBT is a functional testing technique, thereby focusing on output, behavior, and functionality. Performance testing, however, is non-functional and is concerned with responsiveness and stability under various load conditions. MBPeT (Model-Based Performance evaluation Tool) is one such tool which utilizes probabilistic models, representing dynamic real-world user behavior patterns, to generate synthetic workload against a System Under Test and in turn carry out performance analysis based on key performance indicators (KPI). Developed at Åbo Akademi University, the MBPeT tool is currently comprised of a downloadable command-line based tool as well as a graphical user interface. The goal of this thesis project is two-fold: 1) to extend the existing MBPeT tool by deploying it as a web-based application, thereby removing the requirement of local installation, and 2) to design a user interface for this web application which will add new user interaction paradigms to the existing feature set of the tool. All phases of the MBPeT process will be realized via this single web deployment location including probabilistic model creation, test configurations, test session execution against a SUT with real-time monitoring of user configurable metric, and final test report generation and display. This web application (MBPeT Dashboard) is implemented with the Java programming language on top of the Vaadin framework for rich internet application development. The Vaadin framework handles the complicated web communications processes and front-end technologies, freeing developers to implement the business logic as well as the user interface in pure Java. A number of experiments are run in a case study environment to validate the functionality of the newly developed Dashboard application as well as the scalability of the solution implemented in handling multiple concurrent users. The results support a successful solution with regards to the functional and performance criteria defined, while improvements and optimizations are suggested to increase both of these factors.