983 resultados para inertial sensor orientation calibration


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Upper limb function impairment is one of the most common sequelae of central nervous system injury, especially in stroke patients and when spinal cord injury produces tetraplegia. Conventional assessment methods cannot provide objective evaluation of patient performance and the tiveness of therapies. The most common assessment tools are based on rating scales, which are inefficient when measuring small changes and can yield subjective bias. In this study, we designed an inertial sensor-based monitoring system composed of five sensors to measure and analyze the complex movements of the upper limbs, which are common in activities of daily living. We developed a kinematic model with nine degrees of freedom to analyze upper limb and head movements in three dimensions. This system was then validated using a commercial optoelectronic system. These findings suggest that an inertial sensor-based motion tracking system can be used in patients who have upper limb impairment through data integration with a virtual reality-based neuroretation system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thesis (Ph.D.)--University of Washington, 2016-06

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This document does NOT address the issue of oxygen data quality control (either real-time or delayed mode). As a preliminary step towards that goal, this document seeks to ensure that all countries deploying floats equipped with oxygen sensors document the data and metadata related to these floats properly. We produced this document in response to action item 14 from the AST-10 meeting in Hangzhou (March 22-23, 2009). Action item 14: Denis Gilbert to work with Taiyo Kobayashi and Virginie Thierry to ensure DACs are processing oxygen data according to recommendations. If the recommendations contained herein are followed, we will end up with a more uniform set of oxygen data within the Argo data system, allowing users to begin analysing not only their own oxygen data, but also those of others, in the true spirit of Argo data sharing. Indications provided in this document are valid as of the date of writing this document. It is very likely that changes in sensors, calibrations and conversions equations will occur in the future. Please contact V. Thierry (vthierry@ifremer.fr) for any inconsistencies or missing information. A dedicated webpage on the Argo Data Management website (www) contains all information regarding Argo oxygen data management : current and previous version of this cookbook, oxygen sensor manuals, calibration sheet examples, examples of matlab code to process oxygen data, test data, etc..

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this thesis was to study two objective methods of osteoarthritis (OA) diagnosis in horses and use them on the assessment of new intra-articular treatments. The studied methods were a new inertial-sensor based system of lameness detection and cartilage biomarkers in serum. It was found that distal limb flexion is significantly correlated to the presence of metacarpo-phalangeal OA in hind limbs and that inertial-sensors are sensitive in detecting asymmetry in these cases. A positive and significant correlation was observed between Coll2-1 concentration in serum and the presence of joint disease in males and young horses. Fib3-2 measurement has good potential to be used since it is not influenced by sex or age. Using an experimental model of OA, adipose stem cells pre-activated with interferon-gamma decreased joint inflammation and radiographic lesions. In clinical cases, a single injection of high-concentrated and high-molecular weight hyaluronic-acid decreased joint inflammation and biomarkers’ concentration; OSTEOARTRITE DO MEMBRO DISTAL NO CAVALO Resumo: A finalidade desta tese foi estudar dois métodos de diagnóstico objetivo de osteoartrite (OA) em equinos e aplicá-los na avaliação de novas terapias intra-articulares. Utilizou-se um sistema de sensores de movimento e foi avaliada a concentração de biomarcadores de cartilagem no soro. Concluiu-se que a flexão distal positiva está correlacionada com OA na articulação metacarpofalângica nos membros posteriores e que os sensores são sensíveis na detecção de assimetria nestes casos. Existe uma correlação positiva e significativa entre as concentrações de Coll2-1 e a presença de doença articular, sobretudo em machos e jovens. A dosagem de Fib3-2 tem utilidade por não ser influenciada pelo sexo nem idade. Num modelo experimental da doença, a terapia à base de células estaminais reduziu a inflamação articular e as lesões radiográficas. Em casos clínicos, o tratamento com ácido-hialurónico de alta concentração e peso molecular provoca uma diminuição da inflamação articular e dos biomarcadores no soro.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Projeto de Graduação apresentado à Universidade Fernando Pessoa como parte dos requisitos para obtenção do grau de Licenciado em Fisioterapia

Relevância:

100.00% 100.00%

Publicador:

Resumo:

One of the most popular sports globally, soccer has seen a rise in the demands of the game over recent years. An increase in intensity and playing demands, coupled with growing social and economic pressures on soccer players means that optimal preparation is of paramount importance. Recent research has found the modern game, depending on positional role, to consist of approximately 60% more sprint distance in the English Premier League, which was also found to be the case for frequency and success of discrete technical actions (Bush et al., 2015). As a result, the focus on soccer training and player preparedness is becoming more prevalent in scientific research. By designing the appropriate training load, and thus periodization strategies, the aim is to achieve peak fitness in the most efficient way, whilst minimising the risk of injury and illness. Traditionally, training intensity has been based on heart rate responses, however, the emergence of tracking microtechnology such as global positioning system (GPS) and inertial sensors are now able to further quantify biomechanical load as well as physiological stress. Detailed pictures of internal and external loading indices such as these then combine to produce a more holistic view of training load experience by the player during typical drills and phases of training in soccer. The premise of this research is to gain greater understanding of the physical demands of common training methodologies in elite soccer to support optimal match performance. The coaching process may then benefit from being able to prescribe the most effective training to support these. The first experimental chapter in this thesis began by quantify gross training loads of the pre-season and in-season phases in soccer. A broader picture of the training loads inherent in these distinct phases brought more detail as to the type and extent of external loading experienced by soccer players at these times, and how the inclusion of match play influences weekly training rhythms. Training volume (total distance) was found to be high at the start compared to the end of pre-season (37 kilometres and 28 kilometres), where high cardiovascular loads were attained as part of the conditioning focus. This progressed transiently, however, to involve higher-speed, acceleration and change-of-direction stimuli at the end of pre-season compared to the start and to that in-season (1.18 kilometres, 0.70 kilometres and 0.42 kilometres high-intensity running; with 37, 25 and 23 accelerations >3m/s2 respectively) . The decrease in volume and increase in maximal anaerobic activity was evident in the training focus as friendly matches were introduced before the competitive season. The influence of match-play as being a large physical dose in the training week may then determine the change in weekly periodisation and how resulting training loads applied and tapered, if necessary. The focus of research was then directed more specifically to the most common mode of training in soccer, that also featured regularly in the pre-season period in the present study, small-sided games (SSG). The subsequent studies examined numerous manipulations of this specific form of soccer conditioning, such as player numbers as well as absolute and relative playing space available. In contrast to some previous literature, changing the number of players did not seem to influence training responses significantly, although playing format in the possession style brought about larger effects for heart rate (89.9%HRmax) and average velocity (7.6km/h-1). However, the following studies (Chapters 5, 6 and 7) revealed a greater influence of relative playing space available to players in SSG. The larger area at their disposal brought about greater aerobic responses (~90%HRmax), by allowing higher average and peak velocities (>25km/h-1), as well as greater distance acceleration behaviour at greater thresholds (>2.8m/s2). Furthermore, the data points towards space as being a large determinant in strategy of the player in small-sided games (SSG), subsequently shaping their movement behaviour and resulting physical responses. For example, higher average velocities in a possession format (8km/h-1) reflects higher work rate and heart rate load but makes achieving significant neuromuscular accelerations at a high level difficult given higher starting velocities prior to the most intense accelerations (4.2km/h-1). By altering space available and even through intentional numerical imbalances in team numbers, it may be easier for coaches to achieve the desired stimulus for the session or individual player, whether that is for aerobic and neuromuscular conditioning. Large effects were found for heart rate being higher in the underloaded team (85-90%HRmax) compared to the team with more players (80-85%HRmax) as well as for RPE (5AU versus 7AU). This was also apparent for meterage and therefore average velocity. It would also seem neuromuscular load through high acceleration and deceleration efforts were more pronounced with less numbers (given the need to press and close down opponents, and in a larger area relative to the number of players on the underloaded team. The peak accelerations and deceleration achieved was also higher when playing with less players (3-6.2m/s2 and 3-6.1m/s2) Having detailed ways in which to reach desired physical loading responses in common small training formats, Chapter 8 compared SSG to larger 9v9 formats with full-size 11v11 friendly matches. This enabled absolute and relative comparisons to be made and to understand the extent to which smaller training formats are able to replicate the required movements to be successful in competition. In relative terms, it was revealed that relative acceleration distance and Player Load were higher in smaller 4v4 games than match-play (1.1m.min-1 and 0.3m.min-1 >3m/s2; 16.9AU versus 12AU). Although the smallest format did not replicate the high-velocity demands of matches, the results confirmed their efficacy in providing significant neuromuscular load during the training week, which may then be supplemented by high-intensity interval running in order to gain exposure to more maximal speed work. In summary, the data presented provide valuable information from GPS and inertial sensor microtechnology which may then be used to understand training better to manipulate types of load according to physical conditioning objectives. For example, a library of resources to direct planning of drills of varying cardiovascular, neuromuscular and perceptual load can be created to give more confidence in session outcomes. Combining external and internal load data of common soccer training drills, and their application across different phases and training objectives may give coaches a powerful tool to plan and periodize training.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cartilage degradation biomarkers are a potential tool for early diagnosis of degen- erative joint disease (DJD). In young horses, Coll2-1 and Coll2-1NO2 have been studied in serum and reported to be useful in the assessment of joint disease. Fib3-2 has been described to be higher in serum of humans with osteoarthritis but has not been assessed in horses. The aim of the current study was to evaluate biomarkers’ changes with age, sex, and exercise and correlate them with DJD. Blood collection and radiographic examination were performed in 51 Lusitanian horses. Moreover, inertial sensor-based detection of lameness was used to assess pain together with sub- jective examination. Females presented significantly higher concentrations of Coll2- 1 (P5.015) and Coll2-1NO2 (P5.014) compared to males. We found significant influence of high level of work in lower concentration of Coll2-1 (P5.001) and sig- nificant influence of sex in concentration of Coll2-1NO2 (P5.030). There was no influence of sex, age and work on Fib3-2. All biomarkers were increased in the DJD group (n535) compared to healthy controls (n516). This difference was significant for Coll2-1 (P5.015). When sorted by sex and age groups, significant difference in Coll2-1 between disease and healthy controls disappeared in old horses and females. Coll2-1 is a good marker of cartilage degradation in horses with DJD, being more specific in young horses and males. Fib3-2 may be further explored to help identify disease in particular cases.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Cartilage degradation biomarkers are a potential tool for early diagnosis of degenerative joint disease (DJD). In young horses, Coll2-1 and Coll2-1NO2 have been studied in serum and reported to be useful in the assessment of joint disease. Fib3-2 has been described to be higher in serum of humans with osteoarthritis but was never assessed in horses. The aim of the current study was to evaluate biomarkers’ changes with age, sex and exercise and correlate them with DJD. Material and Methods: Blood collection and radiographic examination were performed in 51 Lusitanian horses. Moreover, inertial sensor-based detection of lameness was used to assess pain together with subjective examination. Results: Females presented significantly higher concentrations of Coll2-1 (p = 0.015) and Coll2-1NO2 (p = 0.014) compared to males. We have found significant influence of high level of work in lower concentration of Coll2-1 (p = 0.001) and significant influence of sex in concentration of Coll2-1NO2 (p = 0.030). There was no influence of sex, age and work on Fib3-2. All biomarkers were increased in the DJD group (n= 35) compared to healthy controls (n = 16). This difference was significant for Coll2-1 (p = 0.015). When sorted by sex and age groups, significant difference in Coll2-1 between disease and healthy controls disappeared in old horses and females. Discussion/ Conclusion: Coll2-1 is a good marker of cartilage degradation in horses with DJD, being more specific in young horses and males. Fib3-2 may be further explored to help identify disease in particular cases.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Os espectrómetros instalados a bordo de satélites e à superfície da Terra têm desempenhado um papel fundamental na compreensão da química e dinâmica da atmosfera e na monitorização da poluição ambiental. O SPATRAM (SPectrometer for Atmosferic TRAcers Measurements) é um espectrómetro ultravioleta – Visível que compreende a região espectral entre 250-950nm e se encontra instalado no Instituto de Ciências da Terra (ICT) desde Abril de 2004. Enquanto isso, em 2012, um novo modelo do instrumento SPATRAM foi desenvolvido no ICT e foi chamado SPATRAM2. O objectivo do trabalho proposto é a calibração radiométrica do espectrómetro SPATRAM2, utilizando uma lâmpada de halogéneo e uma esfera de integração. A calibração radiométrica do sistema SPATRAM2 permitirá obter a radiação solar directa, com alta resolução espectral, o que actualmente não se encontra disponível. Este tipo de medição poderá ter um papel importante na investigação e desenvolvimento na área da energia solar e aplicações; Radiometric Calibration of Spectrophotometric Optical Instrumentation Abstract: Spectrometers installed aboard satellites and located on Earth’s surface have played a fundamental role to understand atmosphere’s chemistry and dynamic and to monitor environmental pollution. The SPATRAM (SPectrometer for Atmosferic TRAcers Measurements) instrument is an ultraviolet spectrometer – visible that covers spectral region between 250-950nm and it is installed in Instituto de Ciências da Terra (Institute of Earth Sciencies), ICT, since April 2004. Meanwhile, in 2012, a new model of SPATRAM instrument was developed in ICT and was called SPATRAM2. The goal of this project is the radiometric calibration of the SPATRAM2 spectrometer using a halogen lamp and an integrating sphere. Radiometric calibration of SPATRAM2 system will provide direct solar radiation, with high spectral resolution, that is not available nowadays. This type of measurement may play an important role in solar energy’s progress and investigation.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Traditional motion capture techniques, for instance, those employing optical technology, have long been used in the area of rehabilitation, sports medicine and performance analysis, where accurately capturing bio-mechanical data is of crucial importance. However their size, cost, complexity and lack of portability mean that their use is often impractical. Low cost MEMS inertial sensors when combined and assembled into a Wireless Inertial Measurement Unit (WIMU) present a possible solution for low cost and highly portable motion capture. However due to the large variability inherent to MEMS sensors, such a system would need extensive characterization to calibrate each sensor and ensure good quality data capture. A completely calibrated WIMU system would allow for motion capture in a wider range of real-world, non-laboratory based applications. Calibration can be a complex task, particularly for newer, multi-sensing range capable inertial sensors. As such we present an automated system for quickly and easily calibrating inertial sensors in a packaged WIMU, demonstrating some of the improvements in accuracy attainable.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Calibration of movement tracking systems is a difficult problem faced by both animals and robots. The ability to continuously calibrate changing systems is essential for animals as they grow or are injured, and highly desirable for robot control or mapping systems due to the possibility of component wear, modification, damage and their deployment on varied robotic platforms. In this paper we use inspiration from the animal head direction tracking system to implement a self-calibrating, neurally-based robot orientation tracking system. Using real robot data we demonstrate how the system can remove tracking drift and learn to consistently track rotation over a large range of velocities. The neural tracking system provides the first steps towards a fully neural SLAM system with improved practical applicability through selftuning and adaptation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Wireless Multi-media Sensor Networks (WMSNs) have become increasingly popular in recent years, driven in part by the increasing commoditization of small, low-cost CMOS sensors. As such, the challenge of automatically calibrating these types of cameras nodes has become an important research problem, especially for the case when a large quantity of these type of devices are deployed. This paper presents a method for automatically calibrating a wireless camera node with the ability to rotate around one axis. The method involves capturing images as the camera is rotated and computing the homographies between the images. The camera parameters, including focal length, principal point and the angle and axis of rotation can then recovered from two or more homographies. The homography computation algorithm is designed to deal with the limited resources of the wireless sensor and to minimize energy con- sumption. In this paper, a modified RANdom SAmple Consensus (RANSAC) algorithm is proposed to effectively increase the efficiency and reliability of the calibration procedure.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A system is described for calculating volume from a sequence of multiplanar 2D ultrasound images. Ultrasound images are captured using a video digitising card (Hauppauge Win/TV card) installed in a personal computer, and regions of interest transformed into 3D space using position and orientation data obtained from an electromagnetic device (Polbemus, Fastrak). The accuracy of the system was assessed by scanning 10 water filled balloons (13-141 ml), 10 kidneys (147  200 ml) and 16 fetal livers (8  37 ml) in water using an Acuson 128XP/10 (5 MHz curvilinear probe). Volume was calculated using the ellipsoid, planimetry, tetrahedral and ray tracing methods and compared with the actual volume measured by weighing (balloons) and water displacement (kidneys and livers). The mean percentage error for the ray tracing method was 0.9 ± 2.4%, 2.7 ± 2.3%, 6.6 ± 5.4% for balloons, kidneys and livers, respectively. So far the system has been used clinically to scan fetal livers and lungs, neonate brain ventricles and adult prostate glands.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this paper we present a method for autonomously tuning the threshold between learning and recognizing a place in the world, based on both how the rodent brain is thought to process and calibrate multisensory data and the pivoting movement behaviour that rodents perform in doing so. The approach makes no assumptions about the number and type of sensors, the robot platform, or the environment, relying only on the ability of a robot to perform two revolutions on the spot. In addition, it self-assesses the quality of the tuning process in order to identify situations in which tuning may have failed. We demonstrate the autonomous movement-driven threshold tuning on a Pioneer 3DX robot in eight locations spread over an office environment and a building car park, and then evaluate the mapping capability of the system on journeys through these environments. The system is able to pick a place recognition threshold that enables successful environment mapping in six of the eight locations while also autonomously flagging the tuning failure in the remaining two locations. We discuss how the method, in combination with parallel work on autonomous weighting of individual sensors, moves the parameter dependent RatSLAM system significantly closer to sensor, platform and environment agnostic operation.