990 resultados para imaging method


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper presents the prototype of a low-cost terrestrial mobile mapping system (MMS) composed of a van, two digital video cameras, two GPS receivers, a notebook computer, and a sound frame synchronisation system. The imaging sensors are mounted as a stereo video camera on top of the vehicle together with the GPS antennae. The GPS receivers and the notebook computer are configured to record data referred to the vehicle position at a planned time interval. This position is subsequently transferred to the road images. This set of equipment and methods provide the opportunity to merge distinct techniques to make topographic maps and also to build georeferenced road image databases. Both vector maps and raster image databases, when integrated appropriately, can give spatial researchers and engineers a new technique whose application may realise better planning and analysis related to the road environment. The experimental results proved that the MMS developed at the São Paulo State University is an effective approach to inspecting road pavements, to map road marks and traffic signs, electric power poles, telephone booths, drain pipes, and many other applications important to people's safety and welfare. A small number of wad images have already been captured by the prototype as a consequence of its application in distinct projects. An efficient organisation of those images and the prompt access to them justify the need for building a georeferenced image database. By expanding it, both at the hardware and software levels, it is possible for engineers to analyse the entire road environment on their office computers.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O empilhamento sísmico é um método de imageamento utilizado para simulação de seções sísmicas com afastamento nulo (AN) a partir de dados de cobertura múltipla, produzindo um aumento da razão sinal/ruído na seção simulada. Este método é realizado usando o processamento convencional denominado ponto médio comum (PMC), através das chamadas correções sobretempo normal e sobretempo oblíquo (STN/STO). Alternativamente, um novo método de empilhamento sísmico, denominado superfície de reflexão comum (SRC) pode ser usado para simular seções sísmicas em afastamento nulo (AN). O método SRC tem como principais características: 1) a construção de uma aproximação do tempo de trânsito de reflexões primárias na vizinhança de um raio de reflexão normal; 2) esta aproximação de empilhamento tem como parâmetros os ângulos de emergência do raio normal e os raios de curvaturas de duas ondas hipotéticas denominadas onda ponto de incidência normal (onda PIN) e onda normal (onda N). O método pressupõe ainda que a velocidade da onda longitudinal na parte superior do modelo próxima à superfície da Terra seja conhecida. Para determinar adequadamente os parâmetros supracitados, fundamentais para o método de imageamento SRC, são necessárias estratégias de busca que utilizem casos particulares da aproximação de segunda ordem hiperbólica dos tempos de trânsito. As estratégias de busca apresentadas são: SRC pragmático-extendito e SRC global-local. Neste trabalho é apresentada uma revisão extensa dos fundamentos teóricos de método de empilhamento SRC, como também das estratégias de busca dos parâmetros SRC, dos algoritmos de implementação, e da delimitação de aberturas do operador de empilhamento SRC usando conceitos de zonas de Fresnel e o fator de estiramento da correção STN. Como um exemplo de aplicação dos atributos ou parâmetros SRC é apresentado o resultado da correção STN, sem estiramento do sinal sísmico, obtido utilizando as velocidades estimadas dos parâmetros SRC. Também, são apresentados os resultados da aplicação dos três métodos de empilhamento (PMC (STN/STO), SRC pragmático-extendido, SRC global-local) nos dados sintéticos Marmousi e real terrestre da bacia paleozóica Amazônica. Finalmente apresentam-se as discussões sobre os resultados, quanto à resolução da imagem sísmica e custo computacional.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A simulação de uma seção sísmica de afastamento-nulo (ZO) a partir de dados de cobertura múltipla para um meio 2-D, através do empilhamento, é um método de imageamento de reflexão sísmica muito utilizado, que permite reduzir a quantidade de dados e melhorar a relação sinal/ruído. Segundo Berkovitch et al. (1999) o método Multifoco está baseado na Teoria do Imageamento Homeomórfico e consiste em empilhar dados de cobertura múltipla com distribuição fonte-receptor arbitrária de acordo com uma nova correção de sobretempo, chamada Multifoco. Esta correção de sobretempo esta baseada numa aproximação esférica local da frente de onda focalizante na vizinhança da superfície da terra. Este método permite construir uma seção sísmica no domínio do tempo de afastamento nulo aumentando a relação sinal/ruído. A técnica Multifoco não necessita do conhecimento a priori de um macro-modelo de velocidades. Três parâmetros são usados para descrever a aproximação de tempo de trânsito, Multifoco, os quais são: 1) o ângulo de emergência do raio de afastamento nulo ou raio de reflexão normal (β0), 2) a curvatura da frente de onda no Ponto de Incidência Normal (RNIP) e 3) curvatura da frente de Onda Normal (RN). Sendo também necessário a velocidade próximo a superfície da terra. Neste trabalho de tese aplico esta técnica de empilhamento Multifoco para dados de cobertura múltipla referidos a modelos de velocidade constante e modelo heterogêneos, com o objetivo de simular seções sísmicas afastamento-nulo. Neste caso, como se trata da solução de um problema direto, o macro-modelo de velocidades é considerado conhecido a priori. No contexto do problema inverso tem-se que os parâmetros RNIP, RN e β0 podem ser determinados a partir da análise de coerência aplicada aos dados sísmicos de múltipla cobertura. Na solução deste problema a função objetivo, a ser otimizada, é definida pelo cálculo da máxima coerência existente entre os dados na superfície de empilhamento sísmico. Neste trabalho de tese nos discutimos a sensibilidade da aproximação do tempo de trânsito usado no empilhamento Multifoco, como uma função dos parâmetros RNIP, RN e β0. Esta análise de sensibilidade é feita de três diferentes modos: 1) a primeira derivada da função objetivo, 2) a medida de coerência, denominada semelhança, e 3) a sensibilidade no Empilhamento Multifoco.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Métodos iterativos para a análise de velocidade com migração dependem das funções objetivo medirem a horizontalização dos eventos de reflexão em famílias de ponto imagem comum (CIG). A migração em tempo é um método simples de imageamento para avaliar essas funções objetivo. Usando migração em tempo, estudamos a influência da função objetivo nos resultados da análise de velocidade com migração. Propomos duas novas funções objetivo para a análise velocidade com migração: Semblance Diferencial Estendido e o produto do Semblance Clássico com o Semblance Diferencial Estendido. Experimentos numéricos, utilizando os dados Marmousoft, mostram a eficácia das novas funções objetivo em estimar modelos velocidade produzindo eventos horizontalmente alinhados nas famílias de ponto imagem comum.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

To establish benchmarks and study some sonographic characteristics of the thyroid gland in a group of euthyroid children aged up to 5 years as compared with age-matched children with congenital hypothyroidism. Thirty-six children (17 female and 19 male) aged between 2 months and 5 years were divided into two groups - 23 euthyroid children and 13 children with congenital hypothyroidism - and were called to undergo ultrasonography. In the group of euthyroid children (n = 23), mean total volume of the thyroid gland was 1.12 mL (minimum, 0.39 mL; maximum, 2.72 mL); a homogeneous gland was found in 17 children (73.91%) and 6 children (26.08%) had a heterogeneous gland. In the group of children with congenital hypothyroidism (n = 13), mean total volume of the thyroid gland was 2.73 mL (minimum, 0.20 mL; maximum, 11.00 mL). As regards thyroid location, 3 patients (23.07%) had ectopic thyroid, and 10 (69.23%) had topic thyroid, and out of the latter, 5 had a homogeneous gland (50%) and 5, a heterogeneous gland (50%). In the group with congenital hypothyroidism, 6 (46.15%) children had etiological diagnosis of dyshormoniogenesis, 3 (23.07%), of ectopic thyroid, and 4 (30.76%), of thyroid hypoplasia. Thyroid ultrasonography is a noninvasive imaging method, widely available, easy to perform and for these reasons could, and should, be performed at any time, including at birth, with no preparation or treatment discontinuation, to aid in the early etiological definition of congenital hypothyroidism.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The strain image contrast of some in vivo breast lesions changes with increasing applied load. This change is attributed to differences in the nonlinear elastic properties of the constituent tissues suggesting some potential to help classify breast diseases by their nonlinear elastic properties. A phantom with inclusions and long-term stability is desired to serve as a test bed for nonlinear elasticity imaging method development, testing, etc. This study reports a phantom designed to investigate nonlinear elastic properties with ultrasound elastographic techniques. The phantom contains four spherical inclusions and was manufactured from a mixture of gelatin, agar and oil. The phantom background and each of the inclusions have distinct Young's modulus and nonlinear mechanical behavior. This phantom was subjected to large deformations (up to 20%) while scanning with ultrasound, and changes in strain image contrast and contrast-to-noise ratio between inclusion and background, as a function of applied deformation, were investigated. The changes in contrast over a large deformation range predicted by the finite element analysis (FEA) were consistent with those experimentally observed. Therefore, the paper reports a procedure for making phantoms with predictable nonlinear behavior, based on independent measurements of the constituent materials, and shows that the resulting strain images (e. g., strain contrast) agree with that predicted with nonlinear FEA.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In imaging diagnosis, redundant nerve roots of the cauda equina are characterized by the presence of elongated, enlarged and tortuous nerve roots in close relationship with a high-grade lumbar spinal canal stenosis. This is not an independent entity, but it is believed to be a consequence of the chronic compression at the level of the lumbar canal stenosis and thus may be part of the natural history of lumbar spinal stenosis. The present paper is aimed at reviewing the histopathological, electrophysiological and imaging findings, particularly at magnetic resonance imaging, as well as the clinical meaning of this entity. As the current assessment of canal stenosis and root compression is preferably performed by means of magnetic resonance imaging, this is the imaging method by which the condition is identified. The recognition of redundant nerve roots at magnetic resonance imaging is important, particularly to avoid misdiagnosing other conditions such as intradural arteriovenous malformations. The literature approaching the clinical relevance of the presence of redundant nerve roots is controversial. There are articles suggesting that the pathological changes of the nerve roots are irreversible at the moment of diagnosis and therefore neurological symptoms are less likely to improve with surgical decompression, but such concept is not a consensus.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This thesis presents a new imaging technique for ultracold quantum gases. Since the first observation of Bose-Einstein condensation, ultracold atoms have proven to be an interesting system to study fundamental quantum effects in many-body systems. Most of the experiments use optical imaging rnmethods to extract the information from the system and are therefore restricted to the fundamental limitation of this technique: the best achievable spatial resolution that can be achieved is comparable to the wavelength of the employed light field. Since the average atomic distance and the length scale of characteristic spatial structures in Bose-Einstein condensates such as vortices and solitons is between 100 nm and 500 nm, an imaging technique with an adequate spatial resolution is needed. This is achieved in this work by extending the method of scanning electron microscopy to ultracold quantum gases. A focused electron beam is scanned over the atom cloud and locally produces ions which are subsequently detected. The new imaging technique allows for the precise measurement of the density distribution of a trapped Bose-Einstein condensate. Furthermore, the spatial resolution is determined by imaging the atomic distribution in one-dimensional and two-dimensional optical lattices. Finally, the variety of the imaging method is demonstrated by the selective removal of single lattice site. rn

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In dieser Studie wurde anhand des Modells der Ratte das Gleichgewichtssystem auf cerebro-corticaler Ebene untersucht, und das Verhalten des Gehirns nach akuten sowie chronischen Ausfällen mit funktioneller Bildgebung untersucht. rnMit der Positronen-Emissions-Tomographie (PET) kann die Metabolismusrate bestimmter Gehirnareale gemessen werden. Narkotisierte Tiere wurden unter galvanischer vestibulärer Stimulation im PET gemessen und die Ergebnisse wurden mit Kontrollstimulations-Messungen verglichen. Es konnten verschiedene Areale, die eine erhöhte Stoffwechselaktivität aufwiesen, ermittelt werden. Dazu gehören der somatosensorische und der insuläre Cortex, Teile des auditorischen Cortexes, der anteriore cinguläre sowie der entorhinale Cortex. Subcorticale Strukturen wie der Hippocampus, die Amygdala sowie die latero-dorsalen thalamischen Kerne wiesen ebenfalls erhöhten Stoffwechsel unter vestibulärer Stimulation auf. rnBei dieser PET-Studie handelt es sich um die erste funktionell-bildgebende Studie, die Verarbeitung vestibulärer Informationen bei Ratten in vivo darstellt. Die anatomische Verbindung der gefundenen Areale wurde mit anterograden und retrograden neuronalen Tracings unterstützt. rnDarüber hinaus wurde markiertes Gewebe, welches die Verbindung zwischen thalamischen und cerebro-corticalen Kernen der vestibulären Verschaltung aufweist, immunhistochemisch auf dessen Neurotransmission hin untersucht. Das katecholaminergen und dem opioidergen System wurde untersucht. Eine Beteiligung katecholaminerger Transmitter konnte nicht nachgewiesen werden. Neurone im somatosensorischen Cortex, die positiv auf einen Opioid-Rezeptor-Antikörper getestet wurden erhalten anterograd markierte Terminale aus dem thalamischen Kern LDDM, der mittels der PET als vestibulär identifiziert werden konnte. rnBasierend auf den Ergebnissen der ersten bildgebenden Studie wurde in einer zweiten funktionell-bildgebenden Studie die zentral-vestibuläre Verschaltung unterbrochen, indem relevante thalamische Kerngebiete (LDDM, LDVL) elektrolytisch zerstört wurden. Die Stoffwechselaktivität wurde anschließend bei diesen Tieren an verschiedenen Zeitpunkten nach der Läsion im PET unter vestibulärer Stimulation gemessen. Die Stoffwechselaktivität dieser Tiere wurde mit der Stoffwechselaktivität von Kontroll-Tieren verglichen. rnBei dieser Studie wurde zum ersten Mal, mittels funktioneller Bildgebung gezeigt, welche Bereiche des Gehirns nach akuter und chronischer Läsion des vestibulären Systems an Kompensationsmechanismen beteiligt sind. Alle Gehirnareale, die in verschiedenen Zeitfenstern (1, 3, 7 und 20 Tage nach Läsion) erhöhten Metabolismus aufweisen, sind Teil der vestibulären Verschaltung. Es handelt sich dabei um Areale der Okulomotorik und des räumlichen Gedächtnisses: das Postsubiculum, den Colliculus superior, das mediale Corpus geniculatum, den entorhinalen Cortex sowie die Zona incerta.rn

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A laser scanning microscope collects information from a thin, focal plane and ignores out of focus information. During the past few years it has become the standard imaging method to characterise cellular morphology and structures in static as well as in living samples. Laser scanning microscopy combined with digital image restoration is an excellent tool for analysing the cellular cytoarchitecture, expression of specific proteins and interactions of various cell types, thus defining valid criteria for the optimisation of cell culture models. We have used this tool to establish and evaluate a three dimensional model of the human epithelial airway wall.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

High levels of glucagon-like peptide-1 (GLP-1) receptor expression in human insulinomas and gastrinomas provide an attractive target for imaging, therapy, and intraoperative tumor localization, using receptor-avid radioligands. The goal of this study was to establish a tumor model for GLP-1 receptor targeting and to use a newly designed exendin-4-DTPA (DTPA is diethylenetriaminepentaacetic acid) conjugate for GLP-1 receptor targeting. METHODS: Exendin-4 was modified C-terminally with Lys(40)-NH(2), whereby the lysine side chain was conjugated with Ahx-DTPA (Ahx is aminohexanoic acid). The GLP-1 receptor affinity (50% inhibitory concentration [IC(50)] value) of [Lys(40)(Ahx-DTPA)NH(2)]exendin-4 as well as the GLP-1 receptor density in tumors and different organs of Rip1Tag2 mice were determined. Rip1Tag2 mice are transgenic mice that develop insulinomas in a well-defined multistage tumorigenesis pathway. This animal model was used for biodistribution studies, pinhole SPECT/MRI, and SPECT/CT. Peptide stability, internalization, and efflux studies were performed in cultured beta-tumor cells established from tumors of Rip1Tag2 mice. RESULTS: The GLP-1 receptor affinity of [Lys(40)(Ahx-DTPA)NH(2)]exendin-4 was found to be 2.1 +/- 1.1 nmol/L (mean +/- SEM). Because the GLP-1 receptor density in tumors of Rip1Tag2 mice was very high, a remarkably high tumor uptake of 287 +/- 62 %IA/g (% injected activity per gram tissue) was found 4 h after injection. This resulted in excellent tumor visualization by pinhole SPECT/MRI and SPECT/CT. In accordance with in vitro data, [Lys(40)(Ahx-DTPA-(111)In)NH(2)]exendin-4 uptake in Rip1Tag2 mice was also found in nonneoplastic tissues such as pancreas and lung. However, lung and pancreas uptake was distinctly lower compared with that of tumors, resulting in a tumor-to-pancreas ratio of 13.6 and in a tumor-to-lung ratio of 4.4 at 4 h after injection. Furthermore, in vitro studies in cultured beta-tumor cells demonstrated a specific internalization of [Lys(40)(Ahx-DTPA-(111)In)NH(2)]exendin-4, whereas peptide stability studies indicated a high metabolic stability of the radiopeptide in beta-tumor cells and human blood serum. CONCLUSION: The high density of GLP-1 receptors in insulinomas as well as the high specific uptake of [Lys(40)(Ahx-DTPA-(111)In)NH(2)]exendin-4 in the tumor of Rip1Tag2 mice indicate that targeting of GLP-1 receptors in insulinomas may become a useful imaging method to localize insulinomas in patients, either preoperatively or intraoperatively. In addition, Rip1Tag2 transgenic mice represent a suitable animal tumor model for GLP-1 receptor targeting.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Endobronchial ultrasound (EBUS) has become a major advance in bronchoscopy. Substantial scientific evidence has confirmed its usefulness in lung cancer diagnosis and staging, as well as in other clinical settings. It is of growing importance that endoscopists perform and interpret this imaging method accurately, in order to optimize diagnosis and treatment of their patients. The present article provides a practical and comprehensible review of the two EBUS systems currently available and its main clinical indications.