944 resultados para grating acuity


Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT The aim of the present study was to analyze the influence of enriched environment on the distribution of perineuronal nets (PNNs) using a stereogically based unbiased protocol and visual acuity in adult Swiss albino mice that underwent monocular deprivation during the critical period of postnatal development. Eight female Swiss albino mice were monocular deprived were removed and cut at 70 µm thickness in a vibratome and processed for lectin histochemical staining with Wisteria floribunda agglutinin (WFA). Architectonic limits of area 17 were conspicuously defined by WFA histochemical staining, and the optical fractionator stereological method was applied to estimate the total number of PNNs in the supragranular, granular, and infragranular layers. All groups were compared using Student's t-test at a 95% confidence level. Comparative analysis of the average PNN estimations revealed that the EE group had higher PNNs in the supragranular layer (2726.33 ± 405.416, mean ± standard deviation) compared with the SE group (1543.535 ± 260.686; Student's t-test, p = .0495). No differences were found in the other layers. Visual acuity was significantly lower in the SE group (0.55 cycles/degree) than in the EE group (1.06 cycles/degree). Our results suggest that the integrity of the specialized extracellular matrix PNNs of the supragranular layer may be essential for normal visual acuity development.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo do presente trabalho e analisar a influencia do enriquecimento ambiental sobre a acuidade visual e a distribuição das redes perineuronais (RPNs) no córtex visual primário de camundongos submetidos a privação monocular durante o período critico pos-natal. Camundongos suíços albinos fêmeas foram submetidos a sutura da pálpebra direita no 10o dia pos-natal (M, n=16), enquanto que os animais do grupo binocular não foram submetidos a nenhum procedimento cirúrgico (B, n=16). Ao completarem 21 dias, os animais foram subdivididos em: ambiente padrão e ambiente enriquecido, constituindo os grupos M.AP, M.AE, B.AP e B.AE. Após três meses, os animais foram submetidos ao teste de acuidade visual, perfundidos e secções coronais de seus cérebros processadas para histoquímica da lectina Wisteria floribunda e posterior quantificação através do método estereologico do fracionador óptico. Os animais do grupo B.AP apresentaram acuidade visual de 0.48 ciclos/grau, enquanto que aqueles alojados em ambiente enriquecido (B.AE) apresentaram um melhor desempenho do teste, atingindo 0.996 ciclos/grau. A acuidade visual foi significantemente menor nos animais submetidos a privação monocular (M.AP 0.18 ciclos/grau; M.AE 0.4 ciclos/grau). Os resultados estereologicos revelaram que o ambiente enriquecido aumenta o numero de RPNs tipo 1 e de RPNs total nas camadas supragranular e granular em ambos os hemisférios nos camundongos submetidos a privação monocular (ANOVA dois critérios, p<0.05), sendo que essa diferença na camada granular e decorrente principalmente do aumento das redes perineuronais da matriz extracelular no hemisfério direito. Na camada infragranular, os animais do grupo M.AE apresentaram um aumento apenas no numero de RPNs tipo 1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To review the clinical characteristics of patients with neuromyelitis optica (NMO) and to compare their visual outcome with those of patients with optic neuritis (ON) and multiple sclerosis (MS). Methods: Thirty-three patients with NMO underwent neuro-ophthalmic evaluation, including automated perimetry along with 30 patients with MS. Visual function in both groups was compared overall and specifically for eyes after a single episode of ON. Results: Visual function and average visual field (VF) mean deviation were significantly worse in eyes of patients with NMO. After a single episode of ON, the VF was normal in only 2 of 36 eyes of patients with NMO compared to 17 of 35 eyes with MS (P < 0.001). The statistical analysis indicated that after a single episode of ON, the odds ratio for having NMO was 6.0 (confidence interval [CI]: 1.6-21.9) when VF mean deviation was worse than -20.0 dB while the odds ratio for having MS was 16.0 (CI: 3.6-68.7) when better than -3.0 dB. Conclusion: Visual outcome was significantly worse in NMO than in MS. After a single episode of ON, suspicion of NMO should be raised in the presence of severe residual VF deficit with automated perimetry and lowered in the case of complete VF recovery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Over the last three decades, sensors based on the phenomenon of surface plasmon resonance have proven particularly suitable for real time thin film characterization, gas detection, biomolecular interaction examination and to supplement electrochemical methods. Systems based on prism coupling have been combined with fluorescence detection under the name of surface plasmon fluorescence spectroscopy to increase sensitivity even further. Alternatively, metal gratings can be employed to match photons for plasmon resonance. The real time monitoring of binding reactions not yet been reported in the combination of fluorescence detection and grating coupling. Grating-based systems promise more competitive products, because of reduced operating costs, and offer benefits for device engineering. This thesis is comprised of a comprehensive study of the suitability of grating coupling for fluorescence based analyte detection. Fundamental properties of grating coupled surface plasmon fluorescence spectroscopy are described, as well as issues related to the commercial realization of the method. Several new experimental techniques are introduced and demonstrated in order to optimize performance in certain areas and improve upon capabilities in respect to prism-based systems. Holographically fabricated gratings are characterized by atomic force microscopy and optical methods, aided by simulations and profile parameters responsible for efficient coupling are analyzed. The directional emission of fluorophores immobilized on a grating surface is studied in detail, including the magnitude and geometry of the fluorescence emission pattern for different grating constants and polarizations. Additionally, the separation between the minimum of the reflected intensity and the maximum fluorescence excitation position is examined. One of the key requirements for the commercial feasibility of grating coupling is the cheap and faithful mass production of disposable samples from a given master grating. The replication of gratings is demonstrated by a simple hot embossing method with good reproducibility to address this matter. The in-situ fluorescence detection of analyte immobilization and affinity measurements using grating coupling are described for the first time. The physical factors related to the sensitivity of the technique are assessed and the lower limit of detection of the technique is determined for an exemplary assay. Particular attention is paid to the contribution of bulk fluorophores to the total signal in terms of magnitude and polarization of incident and emitted light. Emission from the bulk can be a limiting factor for experiments with certain assay formats. For that reason, a novel optical method, based on the modulation of both polarization and intensity of the incident beam, is introduced and demonstrated to be capable of eliminating this contribution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Differences in treatment responses to ranibizumab injections observed within trials involving monthly (MARINA and ANCHOR studies) and quarterly (PIER study) treatment suggest that an individualized treatment regimen may be effective in neovascular age-related macular degeneration. In the present study, a drug and disease model was used to evaluate the impact of an individualized, flexible treatment regimen on disease progression.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We evaluated the near visual acuity of 40 dentists and its improvement by using different magnification devices. The acuity was tested with miniaturized E-optotype tests on a negatoscope under the following conditions: 1. natural visual acuity, 300 mm; 2. single lens loupe, 2×, 250 mm; 3. Galilean loupe, 2.5×, 380 mm; and 4. Keplerian loupe, 4.3×, 400 mm. In part 1, the influence of the magnification devices was investigated for all dentists. The Keplerian loupe obtained the highest visual acuity (4.64), followed by the Galilean loupe (2.43), the single lens loupe (1.42), and natural visual acuity (1.19). For part 2, the dentists were classified according to their age (acuity with all magnification devices (p<0.001). For part 3, the dentists were grouped according to their natural visual acuity. The group with the higher natural visual acuity achieved significantly higher visual acuity with all magnification devices than did the group of dentists with the lower natural visual acuity (p<0.01). It can be concluded that near visual acuity varies highly between individuals and decreases during the lifetime. Independent of age or natural vision, visual acuity can be significantly improved by using magnification devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the visual acuity of adult zebrafish by assessing the optokinetic reflex. Using a modified commercially available optomotor device (OptoMotry®), virtual three-dimensional gratings of variable spatial frequency or contrast were presented to adult zebrafish. In a first experiment, visual acuity was evaluated by changing the spatial frequency at different angular velocities. Thereafter, contrast sensitivity was evaluated by changing the contrast level at different spatial frequencies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present experimental results on the intracavity generation of radially polarized light by incorporation of a polarization-selective mirror in a CO2 -laser resonator. The selectivity is achieved with a simple binary dielectric diffraction grating etched in the backsurface of the mirror substrate. Very high polarization selectivity was achieved, and good agreement of simulation and experimental results is shown. The overall radial polarization purity of the generated laser beam was found to be higher than 90% .

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Visual acuity serves as only a rough gauge of macular function. The aim therefore was to ascertain whether central an assessment of the central visual field afforded a closer insight into visual function after removal of epiretinal membranes and Infracyanine-Green- or Trypan-Blue-assisted peeling of the inner limiting membrane. Patients and methods: Fourty-three patients undergoing pars-plana vitrectomy for the removal of epimacular membranes and dye-assisted peeling of the inner limiting membrane using either Infracyanine Green (n = 29; group 1) or Trypan Blue (n = 14; group 2) were monitored prospectively for 12 months. Preoperatively, and 1, 6 and 12 months postoperatively, distance and reading visual acuities were evaluated; the central visual field was assessed by automated static perimetry. RESULTS: Twelve months after surgery, distance and reading visual acuities had improved in both groups, but to a significant degree only in Trypan-Blue-treated eyes. The difference between the two groups was not significant. Likewise at this juncture, the mean size of the visual-field defect remained unchanged in Trypan-Blue-treated eyes (preoperative: 4.3 (SD 2.1) dB; 12 months: 4.0 (2.1) dB (p = 0.15)), but had increased in Infracyanine-Green-treated ones (from 5.3 (3.7) dB to 8.0 (5.2) dB (p = 0.027)). CONCLUSION: Unlike visual acuity, the central visual field had deteriorated in Infracyanine-Green-treated eyes but not in Trypan-Blue-treated eyes 12 months after surgery. Hence, as a predictor of functional outcome, testing of the central visual field may be a more sensitive gauge than visual acuity. Furthermore, Infracyanine Green may have a chronic and potentially clinically relevant effect on the macula which is not reflected in the visual acuity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: To determine the value of the distance doubling visual acuity test in the diagnosis of nonorganic visual loss in a comparative observational case series. METHODS: Twenty-one consecutive patients with nonorganic visual acuity loss and 21 subjects with organic visual loss as controls were included. Best corrected visual acuity was tested at the normal distance of 5 meters using Landolt Cs. The patient was then repositioned and best corrected visual acuity was tested with the previous optotypes at double the distance via a mirror. RESULTS: Nonorganic visual acuity loss was identified in 21 of 21 patients. Sensitivity and specificity of distance-doubling visual acuity test in functional visual loss were found to be 100% (CI; 83%-100%) and 100% (CI; 82%-100%), respectively. CONCLUSION: Distance doubling visual acuity test is widely used to detect nonorganic visual loss. Our results show that this test has a high specificity and sensitivity to detect nonorganic visual impairment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article illustrates the detection of 6 degrees of freedom (DOF) for Virtual Environment interactions using a modified simple laser pointer device and a camera. The laser pointer is combined with a diffraction rating to project a unique laser grid onto the projection planes used in projection-based immersive VR setups. The distortion of the projected grid is used to calculate the translational and rotational degrees of freedom required for human-computer interaction purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES This study examined the near visual acuity of dentists in relation to age and magnification under simulated clinical conditions. MATERIALS AND METHODS Miniaturized visual tests were performed in posterior teeth of a dental phantom head in a simulated clinical setting (dental chair, operating lamp, dental mirror). The visual acuity of 40 dentists was measured under the following conditions: (1) natural visual acuity, distance of 300 mm; (2) natural visual acuity, free choice of distance; (3) Galilean loupes, magnification of ×2.5; (4) Keplerian loupes, ×4.3; (5) operating microscope, ×4, integrated light; (6) operating microscope, ×6.4, integrated light. RESULTS The visual acuity varied widely between individuals and was significantly lower in the group ≥40 years of age (p < 0.001). Significant differences were found between all tested conditions (p < 0.01). Furthermore, a correlation between visual acuity and age was found for all conditions. The performance with the microscope was better than with loupes even with comparable magnification factors. Some dentists had a better visual acuity without optical aids than others with Galilean loupes. CONCLUSIONS Near visual acuity under simulated clinical conditions varies widely between individuals and decreases throughout life. Visual deficiencies can be compensated for with optical aids. CLINICAL RELEVANCE Newly developed miniaturized vision tests have allowed, in a clinically relevant way, to evaluate the influence of magnification and age on the near visual acuity of dentists.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vibrations, Posture, and the Stabilization of Gaze: An Experimental Study on Impedance Control R. KREDEL, A. GRIMM & E.-J. HOSSNER University of Bern, Switzerland Introduction Franklin and Wolpert (2011) identify impedance control, i.e., the competence to resist changes in position, velocity or acceleration caused by environmental disturbances, as one of five computational mechanisms which allow for skilled and fluent sen-sorimotor behavior. Accordingly, impedance control is of particular interest in situa-tions in which the motor task exhibits unpredictable components as it is the case in downhill biking or downhill skiing. In an experimental study, the question is asked whether impedance control, beyond its benefits for motor control, also helps to stabi-lize gaze what, in turn, may be essential for maintaining other control mechanisms (e.g., the internal modeling of future states) in an optimal range. Method In a 3x2x4 within-subject ANOVA design, 72 participants conducted three tests on visual acuity and contrast (Landolt / Grating and Vernier) in two different postures (standing vs. squat) on a platform vibrating at four different frequencies (ZEPTOR; 0 Hz, 4 Hz, 8 Hz, 12 Hz; no random noise; constant amplitude) in a counterbalanced or-der with 1-minute breaks in-between. In addition, perceived exertion (Borg) was rated by participants after each condition. Results For Landolt and Grating, significant main effects for posture and frequency are re-vealed, representing lower acuity/contrast thresholds for standing and for higher fre-quencies in general, as well as a significant interaction (p < .05), standing for in-creasing posture differences with increasing frequencies. Overall, performance could be maintained at the 0 Hz/standing level up to a frequency of 8 Hz, if bending of the knees was allowed. The fact that this result is not only due to exertion is proved by the Borg ratings showing significant main effects only, i.e., higher exertion scores for standing and for higher frequencies, but no significant interaction (p > .40). The same pattern, although not significant, is revealed for the Vernier test. Discussion Apparently, postures improving impedance control not only turn out to help to resist disturbances but also assist in stabilizing gaze in spite of these perturbations. Con-sequently, studying the interaction of these control mechanisms in complex unpre-dictable environments seems to be a fruitful field of research for the future. References Franklin, D. W., & Wolpert, D. M. (2011). Computational mechanisms of sensorimotor control. Neuron, 72, 425-442.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The interaction between sensory rhodopsin II (SRII) and its transducer HtrII was studied by the time-resolved laser-induced transient grating method using the D75N mutant of SRII, which exhibits minimal visible light absorption changes during its photocycle, but mediates normal phototaxis responses. Flash-induced transient absorption spectra of transducer-free D75N and D75N joined to 120 amino-acid residues of the N-terminal part of the SRII transducer protein HtrII (DeltaHtrII) showed only one spectrally distinct K-like intermediate in their photocycles, but the transient grating method resolved four intermediates (K(1)-K(4)) distinct in their volumes. D75N bound to HtrII exhibited one additional slower kinetic species, which persists after complete recovery of the initial state as assessed by absorption changes in the UV-visible region. The kinetics indicate a conformationally changed form of the transducer portion (designated Tr*), which persists after the photoreceptor returns to the unphotolyzed state. The largest conformational change in the DeltaHtrII portion was found to cause a DeltaHtrII-dependent increase in volume rising in 8 micros in the K(4) state and a drastic decrease in the diffusion coefficient (D) of K(4) relatively to those of the unphotolyzed state and Tr*. The magnitude of the decrease in D indicates a large structural change, presumably in the solvent-exposed HAMP domain of DeltaHtrII, where rearrangement of interacting molecules in the solvent would substantially change friction between the protein and the solvent.