994 resultados para grafting to


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this study was to evaluate the long-term influence of xenogenic grafts on bone crestal height and radiographic density following extraction of teeth. The right and left third lower molars of 22 patients were surgically extracted, and one randomly chosen socket was filled with a xenogenic graft (Gent-Tech). The contralateral molar was left to heal naturally, serving as a paired control. Digital intraoral radiographies were taken at surgery and 2, 6, and 24 months after, to evaluate bone density (BD) and alveolar bone crest to cementoenamel junction distance. The data obtained were subjected to two-way analysis of variance and Tukey`s test (alpha = 0.05). The significant decrease in cementoenamel junction distance observed for both groups was limited to the first 6 months. BD values increased significantly in the first 6 months, with no alterations observed up to 24 months for both groups. BD was higher for the experimental group at all time points (p < 0.05). Socket grafting with the xenogenic materials tested did not changed bone crestal height and bone radiographic density in the long term.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Differential scanning calorimetric (DSC) and thermogravimetric analysis (TGA) have been used to study the thermal decomposition, the melting behavior and low-temperature transitions of copolymers obtained by radiation-induced grafting of styrene onto poly (tetrafluoroethylene- perfluoropropylvinylether) (PFA) substrates. PFA with different contents of perfluoropropylvinylether (PPVE) as a comonomer have been investigated. A two step degradation pattern was observed from TGA thermograms of all the grafted copolymers, which was attributed to degradation of PSTY followed by the degradation of the PFA backbone at higher temperature. One broad melting peak can be identified for all copolymers, which has two components in the samples with higher PPVE content. The melting peak, crystal-crystal transition and the degree of crystallinity of the grafted copolymers increases with radiation grafting up to 50 kGy, followed by a decrease at higher doses. No such decrease was observed in the ungrafted PFA samples after irradiation. This indicated that the changes in the heats of transitions and crystallinity at low doses are due to the radiation effects on the microstructure of PFA (chain scission), whereas at higher doses the grafted PSTY is the driving force behind these changes. (C) 2001 Elsevier Science Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A study has been made to investigate the radiation grafting of styrene onto poly(tetrafluoroethylene-co-perfluoropropylvinyl ether) (PFA) substrates, using the simultaneous irradiation method. Two PFA polymers of different comonomer perfluoropropyl vinyl ether (PPVE) content and degree of crystallinity were used. Effects of grafting conditions such as monomer concentrations, type of solvent, dose rate, and irradiation dose on the grafting yield were investigated. Of the six different solvents used, the most efficient in terms of increasing grafting yield were dichloromethane, benzene, and methanol. The degree of grafting increased with increasing radiation dose up to 500 kGy, stabilizing above this dose. However, the grafting yield decreased with an increase in the dose rate. The grafting of styrene onto the PFA substrates was confirmed by FTIR-ATR and micro-Raman spectroscopy, The increase in the overall grafting yield was accompanied by a proportional increase in the penetration depth of the grafts into the substrate.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study concerns the radiation grafting of styrene onto poly(tetrafluoroethylene-co-perfluoropropylvinylether) (PFA) substrates and the penetration depth of the graft. Grafting was obtained by the simultaneous irradiation method, and the spectroscopic analysis was made with the micro-Raman technique. Effects of grafting conditions such as the type of solvent, dose rate, and irradiation dose on the grafting yield were investigated. Of the different solvents used, the most efficient in terms of increasing grafting yield were dichloromethane, benzene, and methanol, respectively. A mixture of methanol and dichloromethane used as a solvent for styrene achieved a higher degree of grafting and concentration of grafted polystyrene onto the surface of PFA substrates than solutions of the monomer in the separate solvents. The degree of grafting increased with increasing radiation dose up to 500 kGy, stabilizing above this dose. However, the grafting yield decreased with an increase in the dose rate. The increase in the overall grafting yield was accompanied by a proportional increase in the penetration depth of the grafts into the substrate. (C) 2002 Wiley Periodicals, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A comparative study has been made of the radiation grafting of styrene onto poly(tetrafluoroethylene-co-perfluoropropyl vinyl ether) (PFA) and polypropylene (PP) substrates, using the simultaneous irradiation method. Effects of grafting conditions such as monomer concentrations, type of solvent, dose rate and irradiation dose on the grafting yield were investigated. Under the same grafting conditions it was found that a higher degree of grafting of styrene was obtained using a mixture of dichloromethane/methanol solvents for PFA and methanol for PP and the degree of grafting was higher in PP than in PFA at all doses. However, the micro-Raman spectroscopy analysis of the graft revealed that, for the same degree of grafting, the penetration depth of the grafted polystyrene into the substrate was higher in PFA than in PP substrates. In both polymers the crystallinity was hardly affected by the grafting process and the degree of crystallinity decreased slightly with grafting dose. The dependence of the initial rate of grafting on the dose rate and the monomer concentration was found to be 0.6 and 1.4 order for PFA and 0.15 and 2.2 for PP, respectively. The degree of grafting increased with increasing radiation dose in both polymers. However, the grafting yield decreased with an increase in the dose rate. The increase in the overall grafting yield for PFA and PP was accompanied by a proportional increase in the penetration depth of the graft into the substrates. (C) 2003 Society of Chemical Industry.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fluoropolymers are known as chemically inert materials with good high temperature resistance, so they are often the materials of choice for harsh chemical environments. These properties arise because the carbon-fluorine bond is the strongest of all bonds between other elements and carbon, and, because of their large size, fluorine atoms can protect the carbon backbone of polymers such as poly(tetrafluoroethylene), PTFE, from chemical attack. However, while the carbon-fluorine bond is much stronger than the carbon hydrogen bond, the G values for radical formation on high energy radiolysis of fluoropolymers are roughly comparable to those of their protonated counterparts. Thus, efficient high energy radiation grafting of fluoropolymers is practical, and this process can be used to modify either the surface or bulk properties of a fluoropolymer. Indeed, radiation grafted fluoropolymers are currently being used as separation membranes for fuel cells, hydrophilic filtration membranes and matrix substrate materials for use in combinatorial chemistry. Herein we present a review of recent studies of the high energy radiation grafting of fluoropolymers and of the analytical methods available to characterize the grafts. (C) 2003 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Poly(tetrafluoroethylene-co-perfluoropropyI vinyl ether), PFA, was grafted with styrene from the vapor phase using a simultaneous radiation grafting method. The graft yields were measured as a function of the dose and dose rate and were found to be initially linearly dependent on the dose and independent of the dose rate up to dose rates of similar to3 kGy/h. However, at a dose rate of 6.2 kGy/h, the slope of the yield-grafting time plot decreased. Raman depth profiles of the grafts showed that the polystyrene concentrations were greatest near the surface of the grafted samples and decreased with depth. The maximum penetration depth of the graft depended on the radiation dose for a fixed dose rate. Fmoc-Rink loading tests showed that the grafts displayed superior loading compared to grafts prepared from bulk styrene or from styrene solutions other than methanol.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Although several tendon sources are available for reconstructive surgical procedures, all have one or more shortcomings. The aim of this work was to evaluate if the extensor tendons of the hallux showed anatomical characteristics that could make them an additional source for tendon grafting procedures.The authors performed a detailed morphometric analysis of the extensor tendons of the hallux in 26 lower limbs in order to evaluate the putative association of anatomical variants with hallux valgus, and to attempt to assess the feasibility of using part of the extensor apparatus of the hallux as a source of tendon for grafting procedures.An accessory extensor hallucis longus ten-don was found in 92.3% of cases. The extensor hallucis brevis tendon length was 10.5 ± 0.6 cm; its width was 0.5 ± 0.1 cm, and its thickness varied between 1-2 mm, making it a potentially good candidate as a source of ten-don grafts. Several anatomical variations were observed, namely the fusion of the tendons of the extensor hallucis brevis and the accessory extensor hallucis longus muscles in the distal part of the foot.This new therapeutic option, if implemented, would possibly increase the supply of autogenous donor tissue for reconstructive procedures, thereby enhancing the reconstructive surgeon’s armamentarium.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: The association between cytokines and troponin-I with cardiac function after cardiac surgery with cardiopulmonary bypass remains a topic of continued investigation. METHODS: Serial measurements, within 24h following surgery, of tumor necrosis factor-alpha, its soluble receptors, and troponin-I were performed in patients with normal ejection fraction undergoing coronary artery bypass grafting. Ejection fraction was measured by radioisotopic ventriculography preoperatively, at 24h and at day 7 postoperatively. RESULTS: Of 19 patients studied (59±8.5 years), 10 (group 1) showed no changes in ejection fraction, 53±8% to 55±7%, and 9 (group 2) had a decrease in ejection fraction, 60±11% to 47±11% (p=0.015) before and 24h after coronary artery bypass grafting, respectively. All immunological variables, except tumor necrosis factor-alpha soluble receptor I at 3h postoperation (5.5± 0.5 in group 1 versus 5.9±0.2 pg/ml in group 2; p=0.048), were similar between groups. Postoperative troponin-I had an inverse correlation with ejection fraction at 24h (r= -0.44). CONCLUSIONS: Inflammatory activity, assessed based on tumor necrosis factor-alpha and its receptors, appears to play a minor role in cardiac dysfunction after cardiac surgery. Troponin I levels are inversely associated with early postoperative ejection fraction.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A 50-year-old man developed recurrent angina 1 year after coronary artery bypass surgery. The patient was found to have a large fistula involving branches of the internal mammary artery graft and the left pulmonary artery. In the absence of another clear cause for the patient's symptoms, we speculated that our patient's angina and abnormal stress nuclear study were due to coronary steal. In patients with a history of coronary bypass grafting, fistula formation between graft and native vessels should be considered as a possible cause of early recurrent angina.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Atrial fibrillation (AF) is a frequent arrhythmia after conventional coronary artery bypass grafting. With the advent of minimally invasive technique for left internal mammary artery-left anterior descending coronary artery (LIMA-LAD) grafting, we analyzed the incidence and the risk factors of postoperative AF in this patient population. This prospective study involves all patients undergoing isolated LIMA-LAD grafting with minimally invasive technique between January 1994 and June 2000. Twenty-four possible risk factors for postoperative AF were entered into univariate and multivariate logistic regression analyses. Postoperative AF occurred in 21 of the 90 patients (23.3%) analyzed. Double- or triple-vessel disease was present in 12/90 patients (13.3%). On univariate analysis, right coronary artery disease (p <0.01), age (p = 0.01), and diabetes (p = 0.04) were found to be risk factors for AF. On multivariate analysis, right coronary artery disease was identified as the sole significant risk factor (p = 0.02). In this patient population, the incidence of AF after minimally invasive coronary artery bypass is in the range of that reported for conventional coronary artery bypass grafting. Right coronary artery disease was found to be an independent predictor, and this may be related to the fact that in this patient population the diseased right coronary artery was not revascularized at the time of the surgical procedure. For the same reason, this risk factor may find a broader application to noncardiac thoracic surgery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: An animal study was carried out to compare long-term patency rates of coronary anastomoses performed with the GraftConnector versus running suture technique. METHODS: 10 sheep, 45 to 55 kg, underwent off-pump coronary artery bypass grafting (right internal mammary artery to left anterior descending artery). In 5 animals, the anastomosis was performed with a GraftConnector and in 5 animals with 7-0 running suture. Intraoperative fluoroscopy and a fluoroscopic control at 6 months were performed. After 6 months, the animals were sacrificed and the anastomoses were examined histologically. RESULTS: All animals survived at 6 months with 100% anastomosis patency rates in both groups. In the GraftConnector group, the anastomosis diameter at 6 months fluoroscopy was 118% of native left anterior descending artery versus 97% of the control group. Luminal anastomotic width at histology was 1.7 +/- 0.2 mm in the device group versus 1.6 +/- 0.1 mm in the control group. Mean intimal hyperplasia thickness was 0.21 +/- 0.1 mm in the device group versus 0.01 mm in the control group. CONCLUSIONS: The GraftConnector provides a consistent and reproducible coronary artery anastomosis and reduces technical demand and manual dexterity in coronary operations. Long-term results demonstrate that off-pump coronary artery bypass grafting performed with the GraftConnector had the same patency rate and luminal width as those performed with running suture.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Cardiopulmonary bypass (CPB) with aortic cross-clamping and cardioplegic arrest remains the method of choice for patients requiring standard myocardial revascularization. Therefore, very high-risk patients presenting with acute coronary syndrome, unstable angina, onset of cardiac decompensation and requiring emergency multiple myocardial revascularization, can have a poor outcome. The on-pump beating heart technique can reduce the mortality and the morbidity in such a selected group of patients and this report describes our clinical experience. METHODS: Out of 290 patients operated for CABG from January 2005 to January 2006, 25 (8.6%) selected high-risk patients suffering from life threatening coronary syndrome (mean age 69 +/- 7 years) and requiring emergency multiple myocardial revascularization, underwent on-pump beating heart surgery. The mean pre-operative left ventricle ejection fraction (LVEF) was 27 +/- 8%. The majority of them (88%) suffered of tri-vessel coronary disease and 6 (24%) had a left main stump disease. Nine patients (35%) were on severe cardiac failure and seven among them (28%) received a pre-operative intra-aortic balloon pump. The pre-operative EuroScore rate was equal or above 8 in 18 patients (73%). RESULTS: All patients underwent on-pump-beating heart coronary revascularization. The mean number of graft/patient was 2.9 +/- 0.6 and the internal mammary artery was used in 23 patients (92%). The mean CPB time was 84 +/- 19 minutes. Two patients died during the recovery stay in the intensive care unit, and there were no postoperative myocardial infarctions between the survivors. Eight patients suffered of transitorily renal failure and 1 patient developed a sternal wound infection. The mean hospital stay was 12 +/- 7 days. The follow-up was complete for all 23 patients survived at surgery and the mean follow-up time was 14 +/- 5 months. One patient died during the follow-up for cardiac arrest and 2 patients required an implantable cardiac defibrillator. One year after surgery they all had a standard trans-thoracic echocardiogram showing a mean LVEF rate of 36 +/- 11.8%. CONCLUSION: Standard on-pump arrested heart coronary surgery has higher mortality and morbidity in emergencies. The on-pump beating heart myocardial revascularization seems to be a valid alternative for the restricted and selected cohort of patients suffering from life threatening coronary syndrome and requiring multiple emergency CABG.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The concept of antibody-mediated targeting of antigenic MHC/peptide complexes on tumor cells in order to sensitize them to T-lymphocyte cytotoxicity represents an attractive new immunotherapy strategy. In vitro experiments have shown that an antibody chemically conjugated or fused to monomeric MHC/peptide can be oligomerized on the surface of tumor cells, rendering them susceptible to efficient lysis by MHC-peptide restricted specific T-cell clones. However, this strategy has not yet been tested entirely in vivo in immunocompetent animals. To this aim, we took advantage of OT-1 mice which have a transgenic T-cell receptor specific for the ovalbumin (ova) immunodominant peptide (257-264) expressed in the context of the MHC class I H-2K(b). We prepared and characterized conjugates between the Fab' fragment from a high-affinity monoclonal antibody to carcinoembryonic antigen (CEA) and the H-2K(b) /ova peptide complex. First, we showed in OT-1 mice that the grafting and growth of a syngeneic colon carcinoma line transfected with CEA could be specifically inhibited by systemic injections of the conjugate. Next, using CEA transgenic C57BL/6 mice adoptively transferred with OT-1 spleen cells and immunized with ovalbumin, we demonstrated that systemic injections of the anti-CEA-H-2K(b) /ova conjugate could induce specific growth inhibition and regression of well-established, palpable subcutaneous grafts from the syngeneic CEA-transfected colon carcinoma line. These results, obtained in a well-characterized syngeneic carcinoma model, demonstrate that the antibody-MHC/peptide strategy can function in vivo. Further preclinical experimental studies, using an anti-viral T-cell response, will be performed before this new form of immunotherapy can be considered for clinical use.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: This study was designed to compare the long-term clinical outcome of coronary artery bypass grafting (CABG) with intracoronary stenting of patients with isolated proximal left anterior descending coronary artery. BACKGROUND: Although numerous trials have compared coronary angioplasty with bypass surgery, none assessed the clinical evaluation in the long term. METHODS: We evaluated the 10-year clinical outcome in the SIMA (Stent versus Internal Mammary Artery grafting) trial. Patients were randomly assigned to stent implantation versus CABG. RESULTS: Of 123 randomized patients, 59 underwent CABG and 62 received a stent (2 patients were excluded). Follow-up after 10 years was obtained for 98% of the randomized patients. Twenty-six patients (42%) in the percutaneous coronary intervention group and 10 patients (17%) in the CABG group reached an end point (p < 0.001). This difference was due to a higher need for additional revascularization. The incidences of death and myocardial infarction were identical at 10%. Progression of the disease requiring additional revascularization was rare (5%) and was similar for the 2 groups. Stent thrombosis occurred in 2 patients (3%). Angina functional class showed no significant differences between the 2 groups. CONCLUSIONS: Both stent implantation and CABG are safe and highly effective in relieving symptoms in patients with isolated, proximal left anterior descending coronary artery stenosis. Stenting with bare-metal stents is associated with a higher need for repeat interventions. The long-term prognosis for these patients is excellent with either mode of revascularization.