989 resultados para glicose oxidase


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The immobilized glucose 2-oxidase (pyranose oxidase, pyranose:oxygen-2-oxidoreductase, EC 1.1.3.10) from Coriolus versicolor was used to convert D-glucose into D-glucosone at moderate pressures, up to 150 bar, with compressed air in a modified commercial batch reactor. Several parameters affecting biocatalysis at moderate pressures were investigated as follows: pressure, different forms of immobilized biocatalysts, glucose concentration, pH, temperature and the presence of catalase. Glucose 2-oxidase (GOX2) was purified by immobilized metal affinity chromatography on epoxy-activated Sepharose 6B-IDA-Cu(II) column at pH 6.0. Purified enzyme and catalase were immobilized into a polyethersulfone (PES) membrane in the presence of glutaraldehyde and gelatin. Enhancement of the bioconversion of D-glucose was done by the pressure since an increase in the pressure with compressed air increases the conversion rates. The optimum temperature and pH for bioconversion of D-glucose were found to be 62 degrees C and pH 6.0, respectively and the activation energy (E(a)) was 28.01 kJ mol(-1). The apparent kinetic constants (V(max)' K(m)', K(cat)' and K(cat)/K(m)') for this bioconversion were 2.27 U mg(-1) protein, 11.15 mM, 8.33 s(-1) and 747.38 s(-1) M(-1), respectively. The immobilized biomass of C. versicolor as well as crude extract containing GOX2 activity were also useful for bioconversion of D-glucose at 65 bar with a yield of 69.9 +/- 3.8% and 91.3 +/- 1.2%, respectively. The immobilized enzyme was apparently stable for several months without any significant loss of enzyme activity. On the other hand, this immobilized enzyme was also stable at moderate pressures, since such pressures did not affect significantly the enzyme activity. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A presente dissertação tem como finalidade apresentar uma investigação teórica e experimental sobre um sensor polarimétrico, portátil e de baixo custo, baseado num cristal líquido para a medição da concentração de glicose existente numa amostra. Devido ao crescente número de pessoas que sofrem de Diabetes, existe grande interesse em desenvolver sensores portáteis que permitam medir a concentração de glicose de forma rápida, precisa e indolor. Dos vários métodos não invasivos existentes para a medição de concentração de glicose, o método utilizado tem como base a medição da rotação da polarização da luz. Recentemente os sensores polarimétricos baseados em cristais líquidos, têm adquirido grande ênfase devido às suas características únicas que, em comparação com outros moduladores electroópticos, funcionam com tensões mais baixas, apresentam menor consumo energético e maior ângulo de rotação. No entanto também existem diversas desvantagens, nomeadamente a falta de documentação sobre a realização de testes e resultados obtidos em sensores polarimétricos. Têm como desvantagem adicional o facto do comportamento do polarímetro ser fortemente dependente do tipo de cristal líquido e da tensão a este aplicado. A presente dissertação descreve o desenvolvimento de um sensor polarimétrico que inclui a componente óptica, a componente electrónica de detecção e acondicionamento do sinal, a comunicação sem fios com um PC, e, por fim, a componente de análise e interface com o utilizador. Neste sensor polarimétrico poderão ser efectuadas leituras de temperatura das amostras para efeitos de correcção do cálculo da concentração da glicose. O dispositivo permite ainda a gravação dos dados obtidos e identificação dos mesmos. Os resultados obtidos demonstram que o dispositivo é capaz de medir concentrações com 10mg/ml de glicose, com uma percentagem de erro de 15%, para uma amostra com um percurso óptico de apenas 1 cm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

contribuindo para o aumento da gordura abdominal, e consequentes complicações metabólicas. O exercício físico permite quebrar este ciclo através da estimulação da lipólise e da utilização de ácidos gordos. Objetivo: Verificar os efeitos de um programa de exercícios no domicílio, em indivíduos com doença arterial coronária, na composição corporal, gordura abdominal, perfil lipídico, glicose, e nível de atividade física. Métodos: Estudo experimental composto por 20 indivíduos, aleatorizados grupo experimental (GE) e grupo de controlo (GC), ambos com 10, tendo o GE sido sujeito ao programa durante 8 semanas. Realizou-se uma avaliação inicial e final, através da bioimpedância, Tomografia Computorizada (TC) abdominal, perimetria, adipometria, análises sanguíneas e acelerómetro. Resultados: Numa análise intergrupal, verificouse uma diminuição da percentagem (%) de gordura total (GT) calculado pela adipometria (p<0.01), na prega supra-ilíaca (p=0.005), na prega abdominal horizontal (p=0.001) e vertical (p=0.003) no GE, e da % de tempo em atividades moderadas no GC (p=0.035). Após 8 semanas o GE diminuiu a %GT (p=0.008); a massa gorda (MG) (p=0.002); perímetro abaixo da última costela (p=0.037) e acima das cristas-ilíacas (p=0.021); %GT calculado (p=0.002); pregas supra-ilíaca (p=0.008), abdominal horizontal (p=0.002) e vertical (p=0.033); TC abdominal subcutâneo (p=0.031) e %de tempo em atividades vigorosas (p=0.031). O GC diminuiu a %GT (p=0.002) e MG (p=0.008); aumentou o perímetro ao nível dos grandes trocânteres (p=0.008), diminuiu o rácio cintura/anca (p=0.002), e a %de tempo em atividades moderadas (p=0.031) e vigorosas (p=0.008). Parece existir uma tendência no GE para diminuição do rácio cintura/anca, c-LDL, triglicerídeos e aumento do nível de atividade moderado. Conclusão: O programa de exercícios no domicílio demonstrou uma diminuição da gordura abdominal, alteração da composição corporal, e parece promover uma melhoria no perfil lipídico e no aumento do nível de atividade física moderado.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os autores estudaram a prevalência da deficiência de glicose-6-fosfato desidrogenase (G6PD), pelo método de BREWER et alii, em 141 indivíduos da população do município de Humaitá, Estado do Amazonas. Destes, 128 eram amazônides, 67 dos quais nunca tiveram malária, enquanto que 61 tinham tido ou estavam tendo a doença; os 13 restantes que estavam com malária não eram arnazônides. Os resultados revelaram que 7 arnazônides (4,96%), eram deficientes. Destes, 5 eram do sexo feminino e 2 do masculino. Em todos os indivíduos do sexo feminino o teste foi positivo com comportamento do tipo heterozigoto. Dos indivíduos deficientes, 4 nunca tinham tido malária; dos outros 3, 2 apresentavam a reação de hemaglutinação positiva com título 1/16 e o terceiro estava tendo malária causada pelo Plasmodium falciparum pela primeira vez. Este doente apresentou forma benigna de malária evoluindo para cura clínica e parasitológica no 3.° dia de tratamento com a clindamicina. Nenhum dos 13 doentes não arnazônides apresentava deficiência de G6PD. Dessa forma, não houve diferença na prevalência da deficiência de G6PD em arnazônides que nunca tiveram malária e em arnazônides que tinham tido ou estavam tendo a doença. Portanto, os indivíduos com deficiência de G6PD estão sujeitos a infecções por Plasmodium falciparum na mesma proporção que os não deficientes. Por outro lado, o aumento da prevalência da deficiência de G6PD, na amostra estudada, poderia estar relacionado com a pressão seletiva exercida pela malária em população submetida à homozigose.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente trabalho teve como objetivo a produção de exoantígenos H e M das amostras 58, B-679, A-811 e O187 de Histoplasma capsulatum, utilizando o meio NGTA (neopeptona, glicose, tiamina e asparagina) em períodos de cultivo de 1, 2 e 3 meses, a 36ºC, sob agitação constante (50 v.p.m.). Os antígenos brutos foram avaliados contra anti-soro e antígeno de Histoplasma capsulatum de referência (Center for Disease Control), 4 soros de pacientes portadores de paracoccidioidomicose, 7 de histoplasmose e soro hiperimune anti-H. capsulatum produzido em coelhos, através da reação de imunodifusão dupla. Verificou-se que, com exceção de B-679 com 1 mês de crescimento, todos os demais exoantígenos apresentaram as frações H e M de precipitação. Os exoantígenos obtidos de A-811 apresentaram só a banda H. Excetuando-se os exoantígenos 58 e B-679 com 1 mês de crescimento, todos os demais exoantígenos reagiram contra soros de pacientes com histoplasmose. Em relação aos soros de pacientes com paracoccidioidomicose, somente os exoantígenos 58 e O187 não apresentaram reação cruzada. Todos os exoantígenos reagiram frente ao soro hiperimune de coelho anti-H. capsulatum. Para obtenção de exoantígenos de H. capsulatum, sugerimos que as amostras sejam cultivadas sob as condições anteriormente descritas, adotando-se o período de 3 meses de crescimento, utilizando-se exoantígenos de referência como controles da reação.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As the prostate cancer (PCa) progresses, sarcosine levels increase both in tumor cells and urine samples, suggesting that this metabolite measurements can help in the creation of non-invasive diagnostic methods for this disease. In this work, a biosensor device was developed for the quantification of sarcosine via electrochemical detection of H2O2 (at 0.6 V) generated from the catalyzed oxidation of sarcosine. The detection was carried out after the modification of carbon screen printed electrodes (SPEs) by immobilization of sarcosine oxidase (SOX) on the electrode surface. The strategies used herein included the activation of the carbon films by an electrochemical step and the formation of an NHS/EDAC layer to bond the enzyme to the electrode, the use of metallic or semiconductor nanoparticles layer previously or during the enzyme immobilization. In order to improve the sensor stability and selectivity a polymeric layer with extra enzyme content was further added. The proposed methodology for the detection of sarcosine allowed obtaining a limit of detection (LOD) of 16 nM, using a linear concentration range between 10 and 100 nM. The biosensor was successfully applied to the analysis of sarcosine in urine samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

XIX Meeting of the Portuguese Electrochemical Society - XVI Iberic Meeting of Electrochemistry

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Sulfite oxidase deficiency (SOD) is an autosomal recessive inherited disease usually presenting in the neonatal period with severe neurological symptoms including seizures, often refractory to anticonvulsant therapy, and a rapidly progressive encephalopathy resembling neonatal hypoxic ischemia, with premature death. Most patients develop dislocated ocular lenses. Later or milder presentations of SOD are being reported with increasing frequency. These presentations include neurological regression with loss of previously acquired milestones or movement disorders. Case report: We report a four years old girl presenting with intermittent ataxia and uncoordinated limb movements. A similar episode of ataxia had occurred previously, one year before, with complete neurologic recovery and normal developmental milestones. Bilateral lens dislocation had been recently diagnosed. Cranial MRI demonstrated bilateral globus pallidus enhancement. Low homocysteine was found in plasma and SulfitestR was positive. Further investigations led to confirmation of isolated sulfite oxidase deficiency with no enzyme activity detected on skin fibroblasts culture. Discussion: This case illustrates the clinical variability of SOD and it is not only atypical but also seems to be the mildest form described so far. The association of ectopia lentis with a movement disorder, even without psychomotor regression, should prompt us to look for this diagnosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

J Biol Inorg Chem (2011) 16:443–460 DOI 10.1007/s00775-010-0741-z

Relevância:

20.00% 20.00%

Publicador:

Resumo:

J Biol Inorg Chem (2007) 12:777–787 DOI 10.1007/s00775-007-0229-7

Relevância:

20.00% 20.00%

Publicador:

Resumo:

J. Am. Chem. Soc., 2004, 126 (28), pp 8614–8615 DOI: 10.1021/ja0490222

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introdução: Em 2012, um comité internacional de peritos em diabetes aconselhou a hemoglobina glicada como teste de rastreio de intolerância à glicose e diabetes mellitus tipo 2 no adulto e em idade pediátrica. O objetivo deste estudo foi avaliar a utilidade deste exame numa população de crianças e adolescentes obesos, maioritariamente de etnia caucasiana. Material e Métodos: Foram recrutados 226 doentes [índice de massa corporal z-score 3,35 ± 0,59, 90% caucasianos, 55% do sexo feminino, idade mediana de 12,3 (âmbito: 8,9 – 17,6) anos] referenciados à consulta de obesidade pediátrica de um hospital terciário, com critérios para rastreio de diabetes mellitus tipo 2. Situações de hemoglobinopatia ou de alteração da sobrevida eritrocitária foram excluídas. Todos os indivíduos foram submetidos a uma prova de tolerância à glicose oral e à medição da hemoglobina glicada. Resultados: Segundo a prova de tolerância à glicose oral, 13 (4,9%) eram pré-diabéticos e nenhum diabético. De acordo com a hemoglobina glicada, 32 seriam pré-diabéticos (29 falsos-positivos) e um diabético (falso positivo, sendo este, na realidade, apenas intolerante à glicose). Por outro lado, 10 pré-diabéticos não seriam identificados (falsos-negativos). A área sob a curva receiver operator characteristic analysis da hemoglobina glicada foi 0,59 (IC 95% 0,40 - 0,78), confirmando a sua reduzida capacidade de discriminação para pré-diabetes. Mais promissoras foram as áreas sob as curvas receiver operator characteristic analysis da glicemia em jejum (0,76; IC 95% 0,66 - 0,87), homeostasis model assessment for insulin resistance (0,77; IC 95% 0,64 - 0,90) e razão triglicerídeos: colesterol HDL (0,81; IC 95% 0,66 - 0,96). Discussão: Em Pediatria, particularmente em populações maioritariamente caucasianas, a hemoglobina glicada parece ser uma má ferramenta para diagnóstico de pré-diabetes. Conclusão: Pelo exposto, parece-nos prematura a utilização da hemoglobina glicada com fins diagnósticos até um maior número de estudos estar disponível. O homeostasis model assessment for insulin resistance e a razão triglicerídeos :colesterol HDL demonstraram uma maior exatidão diagnóstica, podendo ser calculados com base numa amostra única em jejum.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O efeito adverso da primaquina na dose de 0,50mg/kg/dia foi investigado em onze pacientes com malária vivax (três com deficiência de glicose-6-fosfato desidrogenase). Alterações clínicas e laboratoriais indicaram hemólise aguda apenas nos enzimopênicos, o que fez com que o tratamento fosse interrompido. Nossos resultados sugerem a necessidade do emprego de um teste de triagem para a deficiência de G6PD em áreas endêmicas de malária vivax a fim de se evitar complicações causadas pelo uso da primaquina.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este estudo teve como objetivo verificar a ocorrência de metemoglobinemia em indivíduos deficientes da glicose-6-fosfato desidrogenase durante o tratamento da infecção malárica com primaquina. Foram selecionados pacientes com diagnóstico para malária por Plasmodium vivax ou mista V+F (Plasmodium vivax + Plasmodium falciparum), Grupo 1: com 74 indivíduos com diagnóstico clínico de metemoglobinemia e Grupo 2: 161 indivíduos sem diagnóstico clínico de metemoglobinemia. Quanto à deficiência da G6PD, nos Grupos 1 e 2, houveram 51,3% (38) e 8,7% (14) de indivíduos enzimopênicos, respectivamente, demonstrando através de tais dados, significância estatística na associação com a metemoglobinemia somente nos indivíduos do Grupo 1 (p<0,05). A comparação da relação da metemoglobinemia à deficiência da G6PD mostrou haver uma possível associação de indivíduos enzimopênicos desenvolverem metemoglobinemia com maior freqüência.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A solução de glicose a 0,1% perfundida num seguimento intestinal de ratos anestesiados apresenta uma velocidade constante de absorção. A associação do chá da Romã na solução de glicose inibe a sua absorção sem apresentar atividade inibidora residual. O extrato da Romã injetado IP previamente também inibe a absorção da glicose perfundida.Não foi detetada (s) substância (s) inibidora (s) da absorção da glicose.