934 resultados para gait kinematic parameters


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The penalty corner is one of the most important goal plays in field hockey. The drag-flick is used less by women than men in a penalty corner. The aim of this study was to describe training-induced changes in the drag-flick technique in female field hockey players. Four female players participated in the study. The VICON optoelectronic system (Oxford Metrics, Oxford, UK) measured the kinematic parameters of the drag-flick with six cameras sampling at 250 Hz, prior to and after training. Fifteen shots were captured for each subject. A Wilcoxon test assessed the differences between pre-training and post-training parameters. Two players received specific training twice a week for 8 weeks; the other two players did not train. The proposed drills improved the position of the stick at the beginning of the shot (p<0.05), the total distance of the shot (p<0.05)and the rotation radius at ball release (p<0.01). It was noted that all players had lost speed of the previous run. Further studies should include a larger sample, in order to provide more information on field hockey performance.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The objective of this paper is to design a path following control system for a car-like mobile robot using classical linear control techniques, so that it adapts on-line to varying conditions during the trajectory following task. The main advantages of the proposed control structure is that well known linear control theory can be applied in calculating the PID controllers to full control requirements, while at the same time it is exible to be applied in non-linear changing conditions of the path following task. For this purpose the Frenet frame kinematic model of the robot is linearised at a varying working point that is calculated as a function of the actual velocity, the path curvature and kinematic parameters of the robot, yielding a transfer function that varies during the trajectory. The proposed controller is formed by a combination of an adaptive PID and a feed-forward controller, which varies accordingly with the working conditions and compensates the non-linearity of the system. The good features and exibility of the proposed control structure have been demonstrated through realistic simulations that include both kinematics and dynamics of the car-like robot.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We measured the distribution in absolute magnitude - circular velocity space for a well-defined sample of 199 rotating galaxies of the Calar Alto Legacy Integral Field Area Survey (CALIFA) using their stellar kinematics. Our aim in this analysis is to avoid subjective selection criteria and to take volume and large-scale structure factors into account. Using stellar velocity fields instead of gas emission line kinematics allows including rapidly rotating early-type galaxies. Our initial sample contains 277 galaxies with available stellar velocity fields and growth curve r-band photometry. After rejecting 51 velocity fields that could not be modelled because of the low number of bins, foreground contamination, or significant interaction, we performed Markov chain Monte Carlo modelling of the velocity fields, from which we obtained the rotation curve and kinematic parameters and their realistic uncertainties. We performed an extinction correction and calculated the circular velocity v_circ accounting for the pressure support of a given galaxy. The resulting galaxy distribution on the M-r - v(circ) plane was then modelled as a mixture of two distinct populations, allowing robust and reproducible rejection of outliers, a significant fraction of which are slow rotators. The selection effects are understood well enough that we were able to correct for the incompleteness of the sample. The 199 galaxies were weighted by volume and large-scale structure factors, which enabled us to fit a volume-corrected Tully-Fisher relation (TFR). More importantly, we also provide the volume-corrected distribution of galaxies in the M_r - v_circ plane, which can be compared with cosmological simulations. The joint distribution of the luminosity and circular velocity space densities, representative over the range of -20 > M_r > -22 mag, can place more stringent constraints on the galaxy formation and evolution scenarios than linear TFR fit parameters or the luminosity function alone.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

El propósito del presente estudio era generar los valores normativos de salto largo para niños de 9-17.9 años, e investigar las diferencias de sexo y grupo de edad

Relevância:

50.00% 50.00%

Publicador:

Resumo:

This study aimed to analyse the effects of a single stretching exercise session on a number of gait parameters ill elderly participants in all attempt to determine whether these exercises can influence the risk of fall. Fifteen healthy women living in the community Volunteered to participate in the study. A kinematic gait analysis was performed immediately before and after a session of static stretching exercises applied oil hip flexor/extensor muscles. Results showed a significant influence of stretching exercises on a number of gait parameters, which have previously been proposed as fall predictors. Participants showed increased gait velocity, greater step length and reduced double Support time during stance after performing stretching exercises, suggesting improved stability and mobility. Changes around the pelvis (increased anterior-posterior tilt and rotation range of motion) resulting from the stretching exercises were suggested to influence the gait parameters (velocity, step length and double support time). Therefore, stretching exercises were shown to be a promising strategy to facilitate changes in gait parameters related to the risk of fall. Some other gait variables related to the risk of fall remained Unaltered (e.g., toe clearance). The stable pattern of segmental angular velocities was proposed to explain the stability of these unchanged gait variables. The results indicate that stretching exercises, performed oil a regular (daily) basis, result in gait adaptations which can be considered as indicative of reduced fall risk. Other Studies to determine whether regular stretching routines are an effective strategy to reduce the risk of fall are required. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

This pilot study aimed to identify the effects of a 6-month, multimodal exercise program on clinical and gait parameters in patients with Parkinson's disease. Two groups of participants were enrolled in the study: Trained Group (TG) and Control Group (CG). Individuals in the TG exercised three times a week for 24 weeks (in a multimodal exercise program), while the CG participants maintained their regular activity level. Participants in both the TG and the CG were assessed at pre- and posttest by clinical rates and the spatiotemporal parameters of self-paced walking. The two groups were not significantly different in demographic, clinical, and gait data at baseline. There were no significant differences between groups for clinical data at posttest. The purposed multimodal exercise program has found improvement in some kinematic gait parameters for the TG. Further study in the form of randomized controlled trial would be required to establish effectiveness of the intervention.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Introduction: Changes in gait cadence caused by challenging situations in daily life might induce higher demand for strength and propulsion in diabetic neuropathic (DN) subjects. Methods: Forty-six subjects (healthy and DN) walked at two cadences (self-selected and 25% higher). Kinematic and electromyographic data were obtained from lower limbs and compared across the gait cycle. Results: DN subjects showed a delayed peak in plantarflexor activity along the whole cycle (irrespective of cadence) compared with healthy subjects. However, during the imposed cadence, DN individuals showed reduced ankle range of motion along the entire cycle compared with the self-selected condition and healthy individuals walking at both cadences (P = 0.002). Conclusions: These findings suggest that when diabetic individuals face a new challenging situation that induces a higher demand for muscle strength and propulsion, the necessary range of motion and neuromuscular control around distal joints are insufficient. Muscle Nerve 44: 258-268, 2011

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Study design: Single-blind randomized, controlled clinical study. Objectives: To evaluate, using kinematic gait analysis, the results obtained from gait training on a treadmill with body weight support versus those obtained with conventional gait training and physiotherapy. Setting: Thirty patients with sequelae from traumatic incomplete spinal cord injuries at least 12 months earlier; patients were able to walk and were classified according to motor function as ASIA (American Spinal Injury Association) impairment scale C or D. Methods: Patients were divided randomly into two groups of 15 patients by the drawing of opaque envelopes: group A (weight support) and group B (conventional). After an initial assessment, both groups underwent 30 sessions of gait training. Sessions occurred twice a week, lasted for 30min each and continued for four months. All of the patients were evaluated by a single blinded examiner using movement analysis to measure angular and linear kinematic gait parameters. Six patients (three from group A and three from group B) were excluded because they attended fewer than 85% of the training sessions. Results: There were no statistically significant differences in intra-group comparisons among the spatial-temporal variables in group B. In group A, the following significant differences in the studied spatial-temporal variables were observed: increases in velocity, distance, cadence, step length, swing phase and gait cycle duration, in addition to a reduction in stance phase. There were also no significant differences in intra-group comparisons among the angular variables in group B. However, group A achieved significant improvements in maximum hip extension and plantar flexion during stance. Conclusion: Gait training with body weight support was more effective than conventional physiotherapy for improving the spatial-temporal and kinematic gait parameters among patients with incomplete spinal cord injuries. Spinal Cord (2011) 49, 1001-1007; doi:10.1038/sc.2011.37; published online 3 May 2011

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Locomotor tasks characterization plays an important role in trying to improve the quality of life of a growing elderly population. This paper focuses on this matter by trying to characterize the locomotion of two population groups with different functional fitness levels (high or low) while executing three different tasks-gait, stair ascent and stair descent. Features were extracted from gait data, and feature selection methods were used in order to get the set of features that allow differentiation between functional fitness level. Unsupervised learning was used to validate the sets obtained and, ultimately, indicated that it is possible to distinguish the two population groups. The sets of best discriminate features for each task are identified and thoroughly analysed. Copyright © 2014 SCITEPRESS - Science and Technology Publications. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Time periods composing stance phase of gait can be clinically meaningful parameters to reveal differences between normal and pathological gait. This study aimed, first, to describe a novel method for detecting stance and inner-stance temporal events based on foot-worn inertial sensors; second, to extract and validate relevant metrics from those events; and third, to investigate their suitability as clinical outcome for gait evaluations. 42 subjects including healthy subjects and patients before and after surgical treatments for ankle osteoarthritis performed 50-m walking trials while wearing foot-worn inertial sensors and pressure insoles as a reference system. Several hypotheses were evaluated to detect heel-strike, toe-strike, heel-off, and toe-off based on kinematic features. Detected events were compared with the reference system on 3193 gait cycles and showed good accuracy and precision. Absolute and relative stance periods, namely loading response, foot-flat, and push-off were then estimated, validated, and compared statistically between populations. Besides significant differences observed in stance duration, the analysis revealed differing tendencies with notably a shorter foot-flat in healthy subjects. The result indicated which features in inertial sensors' signals should be preferred for detecting precisely and accurately temporal events against a reference standard. The system is suitable for clinical evaluations and provides temporal analysis of gait beyond the common swing/stance decomposition, through a quantitative estimation of inner-stance phases such as foot-flat.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

During free walking, gait is automatically adjusted to provide optimal mechanical output and minimal energy expenditure; gait parameters, such as cadence, fluctuate from one stride to the next around average values. It was described that this fluctuation exhibited long-range correlations and fractal-like patterns. In addition, it was suggested that these long-range correlations disappeared if the participant followed the beep of metronome to regulate his or her pace. Until now, these fractal fluctuations were only observed for stride interval, because no technique existed to adequately analyze an extended time of free walking. The aim of the present study was to measure walking speed (WS), step frequency (SF) and step length (SL) with high accuracy (<1 cm) satellite positioning method (global positioning system or GPS) in order to detect long-range correlations in the stride-to-stride fluctuations. Eight participants walked 30 min under free and constrained (metronome) conditions. Under free walking conditions, DFA (detrended fluctuation analysis) and surrogate data tests showed that the fluctuation of WS, SL and SF exhibited a fractal pattern (i.e., scaling exponent alpha: 0.5 < alpha < 1) in a large majority of participants (7/8). Under constrained conditions (metronome), SF fluctuations became significantly anti-correlated (alpha < 0.5) in all participants. However, the scaling exponent of SL and WS was not modified. We conclude that, when the walking pace is controlled by an auditory signal, the feedback loop between the planned movement (at supraspinal level) and the sensory inputs induces a continual shifting of SF around the mean (persistent anti-correlation), but with no effect on the fluctuation dynamics of the other parameters (SL, WS).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Over the last century, numerous techniques have been developed to analyze the movement of humans while walking and running. The combined use of kinematics and kinetics methods, mainly based on high speed video analysis and forceplate, have permitted a comprehensive description of locomotion process in terms of energetics and biomechanics. While the different phases of a single gait cycle are well understood, there is an increasing interest to know how the neuro-motor system controls gait form stride to stride. Indeed, it was observed that neurodegenerative diseases and aging could impact gait stability and gait parameters steadiness. From both clinical and fundamental research perspectives, there is therefore a need to develop techniques to accurately track gait parameters stride-by-stride over a long period with minimal constraints to patients. In this context, high accuracy satellite positioning can provide an alternative tool to monitor outdoor walking. Indeed, the high-end GPS receivers provide centimeter accuracy positioning with 5-20 Hz sampling rate: this allows the stride-by-stride assessment of a number of basic gait parameters--such as walking speed, step length and step frequency--that can be tracked over several thousand consecutive strides in free-living conditions. Furthermore, long-range correlations and fractal-like pattern was observed in those time series. As compared to other classical methods, GPS seems a promising technology in the field of gait variability analysis. However, relative high complexity and expensiveness--combined with a usability which requires further improvement--remain obstacles to the full development of the GPS technology in human applications.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Tripping is considered a major cause of fall in older people. Therefore, foot clearance (i.e., height of the foot above ground during swing phase) could be a key factor to better understand the complex relationship between gait and falls. This paper presents a new method to estimate clearance using a foot-worn and wireless inertial sensor system. The method relies on the computation of foot orientation and trajectory from sensors signal data fusion, combined with the temporal detection of toe-off and heel-strike events. Based on a kinematic model that automatically estimates sensor position relative to the foot, heel and toe trajectories are estimated. 2-D and 3-D models are presented with different solving approaches, and validated against an optical motion capture system on 12 healthy adults performing short walking trials at self-selected, slow, and fast speed. Parameters corresponding to local minimum and maximum of heel and toe clearance were extracted and showed accuracy ± precision of 4.1 ± 2.3 cm for maximal heel clearance and 1.3 ± 0.9 cm for minimal toe clearance compared to the reference. The system is lightweight, wireless, easy to wear and to use, and provide a new and useful tool for routine clinical assessment of gait outside a dedicated laboratory.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In order to distinguish dysfunctional gait; clinicians require a measure of reference gait parameters for each population. This study provided normative values for widely used parameters in more than 1400 able-bodied adults over the age of 65. We also measured the foot clearance parameters (i.e., height of the foot above ground during swing phase) that are crucial to understand the complex relationship between gait and falls as well as obstacle negotiation strategies. We used a shoe-worn inertial sensor on each foot and previously validated algorithms to extract the gait parameters during 20 m walking trials in a corridor at a self-selected pace. We investigated the difference of the gait parameters between male and female participants by considering the effect of age and height factors. Besides; we examined the inter-relation of the clearance parameters with the gait speed. The sample size and breadth of gait parameters provided in this study offer a unique reference resource for the researchers.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Introduction: Ankle arthrodesis (AD) and total ankle replacement (TAR) are typical treatments for ankle osteoarthritis (AO). Despite clinical interest, there is a lack of their outcome evaluation using objective criteria. Gait analysis and plantar pressure assessment are appropriate to detect pathologies in orthopaedics but they are mostly used in lab with few gait cycles. In this study, we propose an ambulatory device based on inertial and plantar pressure sensors to compare the gait during long-distance trials between healthy subjects (H) and patients with AO or treated by AD and TAR. Methods: Our study included four groups: 11 patients with AO, 9 treated by TAR, 7 treated by AD and 6 control subjects. An ambulatory system (Physilog®, CH) was used for gait analysis; plantar pressure measurements were done using a portable insole (Pedar®-X, DE). The subjects were asked to walk 50 meters in two trials. Mean value and coefficient of variation of spatio-temporal gait parameters were calculated for each trial. Pressure distribution was analyzed in ten subregions of foot. All parameters were compared among the four groups using multi-level model-based statistical analysis. Results: Significant difference (p <0.05) with control was noticed for AO patients in maximum force in medial hindfoot and forefoot and in central forefoot. These differences were no longer significant in TAR and AD groups. Cadence and speed of all pathologic groups showed significant difference with control. Both treatments showed a significant improvement in double support and stance. TAR decreased variability in speed, stride length and knee ROM. Conclusions: In spite of a small sample size, this study showed that ankle function after AO treatments can be evaluated objectively based on plantar pressure and spatio-temporal gait parameters measured during unconstrained walking outside the lab. The combination of these two ambulatory techniques provides a promising way to evaluate foot function in clinics.