996 resultados para flotation plant operations


Relevância:

30.00% 30.00%

Publicador:

Resumo:

A sensitive and robust analytical method for spectrophotometric determination of ethyl xanthate, CH(3)CH(2)OCS(2)(-) at trace concentrations in pulp solutions from froth flotation process is proposed. The analytical method is based on the decomposition of ethyl xanthate. EtX(-), with 2.0 mol L(-1) HCl generating ethanol and carbon disulfide. CS(2). A gas diffusion cell assures that only the volatile compounds diffuse through a PTFE membrane towards an acceptor stream of deionized water, thus avoiding the interferences of non-volatile compounds and suspended particles. The CS(2) is selectively detected by UV absorbance at 206 nm (epsilon = 65,000 L mol(-1) cm(-1)). The measured absorbance is directly proportional to EtX(-) concentration present in the sample solutions. The Beer`s law is obeyed in a 1 x 10(-6) to 2 x 10(-4) mol L(-1) concentration range of ethyl xanthate in the pulp with an excellent correlation coefficient (r = 0.999) and a detection limit of 3.1 x 10(-7) mol L(-1), corresponding to 38 mu g L. At flow rates of 200 mu L min(-1) of the donor stream and 100 mu L min(-1) of the acceptor channel a sampling rate of 15 injections per hour could be achieved with RSD < 2.3% (n = 10, 300 mu L injections of 1 x 10(-5) mol L(-1) EtX(-)). Two practical applications demonstrate the versatility of the FIA method: (i) evaluation the free EtX(-) concentration during a laboratory study of the EtX(-) adsorption capacity on pulverized sulfide ore (pyrite) and (ii) monitoring of EtX(-) at different stages (from starting load to washing effluents) of a flotation pilot plant processing a Cu-Zn sulfide ore. (C) 2010 Elsevier By. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Field experiments carried out with Cyperus rotundus L. at low (58-246), medium (318773), and high (675-1198 shoots/m(2)) densities showed sugarcane yield reductions of 13.5, 29.3, and 45.2%, respectively in relation to the control. In the second field experiment, the integration of a mechanic method with two sequences of plowing and disking operations in the dry season, and complementary applications of trifloxysulfuron-sodium + ametrine and sulfentrazone (rainy season) was studied. Average of the chain connected to original shoot showed 92, 95, and 65% of reduction with trifloxysulfuron-sodium + ametrine and surfactant, at the application stages early, preflowering, and full flowering, respectively.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

From the end of 2013 and during the following two years, 20 kt of CO2sc are planned to be injected in a saline reservoir (1500 m depth) at the Hontomín site (NE Spain). The target aquifers are Lower Jurassic limestone formations which are sealed by Lower Cretaceous clay units at the Hontomín site (NE Spain). The injection of CO2 is part of the activities committed in the Technology Development phase of the EC-funded OXYCFB300 project (European Energy Program for Recovery – EEPR, http://www.compostillaproject.eu), which include CO2 injection strategies, risk assessment, and testing and validating monitoring methodologies and techniques. Among the monitoring works, the project is intended to prove that present-day technology is able to monitor the evolution of injected CO2 in the reservoir and to detect potential leakage. One of the techniques is the measurement of CO2 flux at the soil–atmosphere interface, which includes campaigns before, during and after the injection operations. In this work soil CO2 flux measurements in the vicinity of oil borehole, drilled in the eighties and named H-1 to H-4, and injection and monitoring wells were performed using an accumulation chamber equipped with an IR sensor. Seven surveys were carried out from November 2009 to summer 2011. More than 4000 measurements were used to determine the baseline flux of CO2 and its seasonal variations. The measured values were low (from 5 to 13 g m−2 day−1) and few outliers were identified, mainly located close to the H-2 oil well. Nevertheless, these values cannot be associated to a deep source of CO2, being more likely related to biological processes, i.e. soil respiration. No anomalies were recognized close to the deep fault system (Ubierna Fault) detected by geophysical investigations. There, the CO2 flux is indeed as low as other measurement stations. CO2 fluxes appear to be controlled by the biological activity since the lowest values were recorded during autumn-winter seasons and they tend to increase in warm periods. Two reference CO2 flux values (UCL50 of 5 g m−2 d−1 for non-ploughed areas in autumn–winter seasons and 3.5 and 12 g m−2 d−1 for in ploughed and non-ploughed areas, respectively, in spring–summer time, and UCL99 of 26 g m−2 d−1 for autumn–winter in not-ploughed areas and 34 and 42 g m−2 d−1 for spring–summer in ploughed and not-ploughed areas, respectively) were calculated. Fluxes higher than these reference values could be indicative of possible leakage during the operational and post-closure stages of the storage project.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

"United States Atomic Energy Commission, Savannah River Operations Office, Contract AT (38-1) 213, supplements 1 & 2."

Relevância:

30.00% 30.00%

Publicador:

Resumo:

"NUREG-0698."

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This communication reports a laboratory and plant comparison between the University of Cape Town (UCT) device (capillary) and the McGill University bubble sizing method (imaging). The laboratory work was conducted on single bubbles to establish the accuracy of the techniques by comparing with a reference method (capture in a burette). Single bubble measurements with the McGill University technique showed a tendency to slightly underestimate (4% for a 1.3 mm bubble) and the UCT technique to slightly overestimate (1% for the 1.3 man bubble). Both trends are anticipated from fundamental considerations. In the UCT technique bubble breakup was observed when measuring a 2.7 mm bubble using a 0.5 mm ID capillary tube. A discrepancy of 11% was determined when comparing the techniques in an industrial-scale mechanical flotation cell. The possible sources of bias are discussed. (C) 2003 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Water recovery is one of the key parameters in flotation modelling for the purposes of plant design and process control, as it determines the circulating flow and residence time in the individual process units in the plant and has a significant effect on entrainment and froth recovery. This paper reviews some of the water recovery models available in the literature, including both empirical and fundamental models. The selected models are tested using the data obtained from the experimental work conducted in an Outokumpu 3 m(3) tank cell at the Xstrata Mt Isa copper concentrator. It is found that all the models fit the experimental data reasonably well for a given flotation system. However, the empirical models are either unable to distinguish the effect of different cell operating conditions or required to determine the empirical model parameters to be derived in an existing flotation system. The model developed by [Neethling, SJ., Lee, H.T., Cilliers, J.J., 2003, Simple relationships for predicting the recovery of liquid from flowing foams and froths. Minerals Engineering 16, 1123-1130] is based on fundamental understanding of the froth structure and transfer of the water in the froth. It describes the water recovery as a function of the cell operating conditions and the froth properties which can all be determined on-line. Hence, the fundamental model can be used for process control purposes in practice. By incorporating additional models to relate the air recovery and surface bubble size directly to the cell operating conditions, the fundamental model can also be used for prediction purposes. (C) 2005 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Jameson Cell is a high intensity flotation device, which utilises induced air from the atmosphere. It was developed jointly by Mount Isa Mines and Professor Graeme Jameson of the University of Newcastle in the 1980s. It is proven to generate fine bubbles, in the order of 300 to 500 µm, in a high intensity, high shear and compact zone contained in the downcomer. This aerated mixture exits the downcomer into the pulp zone, which is the quiescent mineral and gangue separation zone. A number of Australian base metal flotation circuits feature a reverse flotation stage at the head of the circuit. Testwork and plant operating data has shown that the use of a Jameson Cell in the prefloat cleaner application has further improved prefloat gangue recovery and selectivity. Operation of a Jameson Cell in a carbonaceous/pyrite prefloat cleaner duty at the Mt Isa copper concentrator increased copper recovery and reduced pyrite in the copper concentrate. Testwork at Zinifex Century Zinc Mine showed a decrease in zinc losses by the utilisation of Jameson Cell prefloat cleaner. Appraisal of a Jameson Cell in a scalping role within the Mt Isa Copper Concentrator indicated significant benefits could be achieved.