696 resultados para feeder reconfiguration
Resumo:
Reconfigurable computing is becoming an important new alternative for implementing computations. Field programmable gate arrays (FPGAs) are the ideal integrated circuit technology to experiment with the potential benefits of using different strategies of circuit specialization by reconfiguration. The final form of the reconfiguration strategy is often non-trivial to determine. Consequently, in this paper, we examine strategies for reconfiguration and, based on our experience, propose general guidelines for the tradeoffs using an area-time metric called functional density. Three experiments are set up to explore different reconfiguration strategies for FPGAs applied to a systolic implementation of a scalar quantizer used as a case study. Quantitative results for each experiment are given. The regular nature of the example means that the results can be generalized to a wide class of industry-relevant problems based on arrays.
Resumo:
Observations are presented of the response of the dayside cusp/cleft aurora to changes in both the clock and elevation angles of the interplanetary magnetic field (IMF) vector, as monitored by the WIND spacecraft. The auroral observations are made in 630 nm light at the winter solstice near magnetic noon, using an all-sky camera and a meridian-scanning photometer on the island of Spitsbergen. The dominant change was the response to a northward turning of the IMF which caused a poleward retreat of the dayside aurora. A second, higher-latitude band of aurora was seen to form following the northward turning, which is interpreted as the effect of lobe reconnection which reconfigures open flux. We suggest that this was made possible in the winter hemisphere, despite the effect of the Earth's dipole tilt, by a relatively large negative X component of the IMF. A series of five events then formed in the poleward band and these propagated in a southwestward direction and faded at the equatorward edge of the lower-latitude band as it migrated poleward. It is shown that the auroral observations are consistent with overdraped lobe flux being generated by lobe reconnection in the winter hemisphere and subsequently being re-closed by lobe reconnection in the summer hemisphere. We propose that the balance between the reconnection rates at these two sites is modulated by the IMF elevation angle, such that when the IMF points more directly northward, the summer lobe reconnection site dominates, re-closing all overdraped lobe flux and eventually becoming disconnected from the Northern Hemisphere.
Resumo:
The reconfiguration of a distribution network is a change in its topology, aiming to provide specific operation conditions of the network, by changing the status of its switches. It can be performed regardless of any system anomaly. The service restoration is a particular case of reconfiguration and should be performed whenever there is a network failure or whenever one or more sections of a feeder have been taken out of service for maintenance. In such cases, loads that are supplied through lines sections that are downstream of portions removed for maintenance may be supplied by the closing of switches to the others feeders. By classical methods of reconfiguration, several switches may be required beyond those used to perform the restoration service. This includes switching feeders in the same substation or for substations that do not have any direct connection to the faulted feeder. These operations can cause discomfort, losses and dissatisfaction among consumers, as well as a negative reputation for the energy company. The purpose of this thesis is to develop a heuristic for reconfiguration of a distribution network, upon the occurrence of a failure in this network, making the switching only for feeders directly involved in this specific failed segment, considering that the switching applied is related exclusively to the isolation of failed sections and bars, as well as to supply electricity to the islands generated by the condition, with significant reduction in the number of applications of load flows, due to the use of sensitivity parameters for determining voltages and currents estimated on bars and lines of the feeders directly involved with that failed segment. A comparison between this process and classical methods is performed for different test networks from the literature about networks reconfiguration
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The objective of this study was to compare the effects of 24-h road transport or 24-h feed and water deprivation on acute-phase and performance responses of feeder cattle. Angus x Hereford steers (n = 30) and heifers (n = 15) were ranked by gender and BW (217 +/- 3 kg initial BW; 185 +/- 2 d initial age) and randomly assigned to 15 pens on d -12 of the experiment (3 animals/pen; 2 steers and 1 heifer). Cattle were fed alfalfa-grass hay ad libitum and 2.3 kg/animal daily (DM basis) of a corn-based concentrate throughout the experiment (d -12 to 28). on d 0, pens were randomly assigned to 1 of 3 treatments: 1) transport for 24 h in a livestock trailer for 1,200 km (TRANS), 2) no transport but feed and water deprivation for 24 h (REST), or 3) no transport and full access to feed and water (CON). Treatments were concurrently applied from d 0 to d 1. Total DMI was evaluated daily from d -12 to d 28. Full BW was recorded before treatment application (d -1 and 0) and at the end of experiment (d 28 and 29). Blood samples were collected on d 0, 1, 4, 7, 10, 14, 21, and 28. Mean ADG was greater (P < 0.01) in CON vs. TRANS and REST cattle but similar (P = 0.46) between TRANS and REST cattle (1.27, 0.91, and 0.97 kg/d, respectively; SEM = 0.05). No treatment effects were detected for DMI (P >= 0.25), but CON had greater G: F vs. TRANS (P < 0.01) and REST cattle (P = 0.08) whereas G: F was similar (P = 0.21) between TRANS and REST cattle. Plasma cortisol concentrations were greater (P <= 0.05) in REST vs. CON and TRANS cattle on d 1, 7, 14, and 28 and also greater (P = 0.02) in TRANS vs. CON cattle on d 1. Serum NEFA concentrations were greater (P < 0.01) in REST and TRANS vs. CON cattle on d 1 and greater (P < 0.01) in REST vs. TRANS cattle on d 1. Plasma ceruloplasmin concentrations were greater (P = 0.04) in TRANS vs. CON cattle on d 1, greater (P = 0.05) in REST vs. CON on d 4, and greater (P <= 0.05) in REST vs. TRANS and CON on d 14. Plasma haptoglobin concentrations were greater (P < 0.01) in TRANS vs. CON and REST cattle on d 1 and greater (P <= 0.05) for REST vs. TRANS and CON cattle on d 7. In conclusion, 24-h transport and 24-h nutrient deprivation elicited acute-phase protein reactions and similarly reduced feedlot receiving performance of feeder cattle. These results suggest that feed and water deprivation are major contributors to the acute-phase response and reduced feedlot receiving performance detected in feeder cattle transported for long distances.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Distribution systems with distributed generation require new analysis methods since networks are not longer passive. Two of the main problems in this new scenario are the network reconfiguration and the loss allocation. This work presents a distribution systems graphic simulator, developed with reconfiguration functions and a special focus on loss allocation, both considering the presence of distributed generation. This simulator uses a fast and robust power flow algorithm based on the current summation backward-forward technique. Reconfiguration problem is solved through a heuristic methodology and the losses allocation function, based on the Zbus method, is presented as an attached result for each obtained configuration. Results are presented and discussed, remarking the easiness of analysis through the graphic simulator as an excellent tool for planning and operation engineers, and very useful for training. © 2004 IEEE.
Resumo:
Low flexibility and reliability in the operation of radial distribution networks make those systems be constructed with extra equipment as sectionalising switches in order to reconfigure the network, so the operation quality of the network can be improved. Thus, sectionalising switches are used for fault isolation and for configuration management (reconfiguration). Moreover, distribution systems are being impacted by the increasing insertion of distributed generators. Hence, distributed generation became one of the relevant parameters in the evaluation of systems reconfiguration. Distributed generation may affect distribution networks operation in various ways, causing noticeable impacts depending on its location. Thus, the loss allocation problem becomes more important considering the possibility of open access to the distribution networks. In this work, a graphic simulator for distribution networks with reconfiguration and loss allocation functions, is presented. Reconfiguration problem is solved through a heuristic methodology, using a robust power flow algorithm based on the current summation backward-forward technique, considering distributed generation. Four different loss allocation methods (Zbus, Direct Loss Coefficient, Substitution and Marginal Loss Coefficient) are implemented and compared. Results for a 32-bus medium voltage distribution network, are presented and discussed.
Resumo:
In this paper a genetic algorithm based reconfiguration method is proposed to minimize the real power losses of distribution systems. The main innovation of this research work is that new types of crossover and mutation operators are proposed, such that the best possible results are obtained, with an acceptable computational effort. The crossover and mutation operators were developed so as to take advantage of the particular characteristics of distribution systems (as the radial topology). Simulation results indicate that the proposed method is very efficient, being able to find excellent configurations, with low computational effort, especially for larger systems. ©2007 IEEE.
Resumo:
Network reconfiguration is an important tool to optimize the operating conditions of a distribution system. This is accomplished modifying the network structure of distribution feeders by changing the open/close status of sectionalizing switches. This not only reduces the power losses, but also relieves the overloading of the network components. Network reconfiguration belongs to a complex family of problems because of their combinatorial nature and multiple constraints. This paper proposes a solution to this problem, using a specialized evolutionary algorithm, with a novel codification, and a brand new way of implement the genetic operators considering the problem characteristics. The algorithm is presented and tested in a real distribution system, showing excellent results and computational efficiency. © 2007 IEEE.
Resumo:
In an evermore competitive environment, power distribution companies need to continuously monitor and improve the reliability indices of their systems. The network reconfiguration (NR) of a distribution system is a technique that well adapts to this new deregulated environment for it allows improvement of system reliability indices without the onus involved in procuring new equipment. This paper presents a reliability-based NR methodology that uses metaheuristic techniques to search for the optimal network configuration. Three metaheuristics, i.e. Tabu Search, Evolution Strategy, and Differential Evolution, are tested using a Brazilian distribution network and the results are discussed. © 2009 IEEE.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The problem of reconfiguration of distribution systems considering the presence of distributed generation is modeled as a mixed-integer linear programming (MILP) problem in this paper. The demands of the electric distribution system are modeled through linear approximations in terms of real and imaginary parts of the voltage, taking into account typical operating conditions of the electric distribution system. The use of an MILP formulation has the following benefits: (a) a robust mathematical model that is equivalent to the mixed-integer non-linear programming model; (b) an efficient computational behavior with exiting MILP solvers; and (c) guarantees convergence to optimality using classical optimization techniques. Results from one test system and two real systems show the excellent performance of the proposed methodology compared with conventional methods. © 2012 Published by Elsevier B.V. All rights reserved.