879 resultados para false negative


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: 1. To assess the diagnostic value of MDCT for acute colitis of various origin confirmed by colonoscopy and histology. 2. To evaluate the accuracy of MDCT of making the correct differential diagnosis. Methods and materials: The electronic hospital database from January 2006 to August 2008 revealed 351 patients with acute colitis of any origin wdetected by colonoscopy. In 85 out of these patients MDCT had been simultaneously performed (delay 3.1 days). Two radiologists jointly reviewed their corresponding CT features without knowledge of pathology and correlated them with the final histological diagnosis. Results: Eighty patients were finally included (46 women, mean age 63.4). Colitis was of ischemic (n = 35, 44%) or infectious (n = 15, 19%) origin. 18 patients (23%) had acute ulcerative colitis or Crohn's disease, in 10 patients (12%) another inflammatory cause and in two patients (2%) post radiation colitis was proven. MDCT was positive in 63 patients (78.9%). In 11 out of the 17 negative MDCT, the examination had been performed without large bowel distention. Ischemic colitis was responsible for 47.1% of the negative MDCT. Correct differential diagnosis was made in 32 (50.7%) out of the 63 positive MDCT. Among the different etiologies, the ischemic colitis was the most often misdiagnosed cause (n = 17, 58.6%). Conclusion: Large bowel distension is mandatory for reliable MDCT detection of acute colitis of any origin. Among the different aetiologies the ischemic cause is the most often associated with false negative MDCT findings and, in case of positive features, the most difficult to recognize as such.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction: The general strategy to perform anti-doping analysis starts with a screening followed by a confirmatory step when a sample is suspected to be positive. The screening step should be fast, generic and able to highlight any sample that may contain a prohibited substance by avoiding false negative and reducing false positive results. The confirmatory step is a dedicated procedure comprising a selective sample preparation and detection mode. Aim: The purpose of the study is to develop rapid screening and selective confirmatory strategies to detect and identify 103 doping agents in urine. Methods: For the screening, urine samples were simply diluted by a factor 2 with ultra-pure water and directly injected ("dilute and shoot") in the ultrahigh- pressure liquid chromatography (UHPLC). The UHPLC separation was performed in two gradients (ESI positive and negative) from 5/95 to 95/5% of MeCN/Water containing 0.1% formic acid. The gradient analysis time is 9 min including 3 min reequilibration. Analytes detection was performed in full scan mode on a quadrupole time-of-flight (QTOF) mass spectrometer by acquiring the exact mass of the protonated (ESI positive) or deprotonated (ESI negative) molecular ion. For the confirmatory analysis, urine samples were extracted on SPE 96-well plate with mixed-mode cation (MCX) for basic and neutral compounds or anion exchange (MAX) sorbents for acidic molecules. The analytes were eluted in 3 min (including 1.5 min reequilibration) with a S1-25 Ann Toxicol Anal. 2009; 21(S1) Abstracts gradient from 5/95 to 95/5% of MeCN/Water containing 0.1% formic acid. Analytes confirmation was performed in MS and MS/MS mode on a QTOF mass spectrometer. Results: In the screening and confirmatory analysis, basic and neutral analytes were analysed in the positive ESI mode, whereas acidic compounds were analysed in the negative mode. The analyte identification was based on retention time (tR) and exact mass measurement. "Dilute and shoot" was used as a generic sample treatment in the screening procedure, but matrix effect (e.g., ion suppression) cannot be avoided. However, the sensitivity was sufficient for all analytes to reach the minimal required performance limit (MRPL) required by the World Anti Doping Agency (WADA). To avoid time-consuming confirmatory analysis of false positive samples, a pre-confirmatory step was added. It consists of the sample re-injection, the acquisition of MS/MS spectra and the comparison to reference material. For the confirmatory analysis, urine samples were extracted by SPE allowing a pre-concentration of the analyte. A fast chromatographic separation was developed as a single analyte has to be confirmed. A dedicated QTOF-MS and MS/MS acquisition was performed to acquire within the same run a parallel scanning of two functions. Low collision energy was applied in the first channel to obtain the protonated molecular ion (QTOF-MS), while dedicated collision energy was set in the second channel to obtain fragmented ions (QTOF-MS/MS). Enough identification points were obtained to compare the spectra with reference material and negative urine sample. Finally, the entire process was validated and matrix effects quantified. Conclusion: Thanks to the coupling of UHPLC with the QTOF mass spectrometer, high tR repeatability, sensitivity, mass accuracy and mass resolution over a broad mass range were obtained. The method was sensitive, robust and reliable enough to detect and identify doping agents in urine. Keywords: screening, confirmatory analysis, UHPLC, QTOF, doping agents

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Forensic scientists have long detected the presence of drugs and their metabolites in biological materials using body fluids such as urine, blood and/or other biological liquids or tissues. For doping analysis, only urine has so far been collected. In recent years, remarkable advances in sensitive analytical techniques have encouraged the analysis of drugs in unconventional biological samples such as hair, saliva and sweat. These samples are easily collected, although drug levels are often lower than the corresponding levels in urine or blood. This chapter reviews recent studies in the detection of doping agents in hair, saliva and sweat. Sampling, analytical procedures and interpretation of the results are discussed in comparison with those obtained from urine and blood samples.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Sentinel lymph node dissection (SLND) identifies melanoma patients with metastatic disease who would benefit from radical lymph node dissection (RLND). Rarely, patients with melanoma have an underlying lymphoproliferative disease, and melanoma metastases might develop as collision tumours in the sentinel lymph node (SLN). The aim of this study was to measure the incidence and examine the effect of collision tumours on the accuracy of SLND and on the validity of staging in this setting. Between 1998 and 2012, 750 consecutive SLNDs were performed in melanoma patients using the triple technique (lymphoscintigraphy, gamma probe and blue dye). The validity of SLND in collision tumours was analysed. False negativity was reflected by the disease-free survival. The literature was reviewed on collision tumours in melanoma. Collision tumours of melanoma and chronic lymphocytic leukaemia (CLL) were found in two SLN and in one RLND (0.4%). Subsequent RLNDs of SLND-positive cases were negative for melanoma. The patient with negative SLND developed relapse after 28 months with an inguinal lymph node metastasis of melanoma; RLND showed collision tumours. The literature review identified 12 cases of collision tumours. CLL was associated with increased melanoma incidence and reduced overall survival. This is, to our knowledge, the first assessment of the clinical value of SLND when collision tumours of melanoma and CLL are found. In this small series of three patients with both malignancies present in the same lymph node basin, lymphocytic infiltration of the CLL did not alter radioisotope uptake into the SLN. No false-negative result was observed. Our data suggest the validity of SLND in collision tumours, but given the rarity of the problem, further studies are necessary to confirm this reliability.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Abstract-Due to the growing use of biometric technologies inour modern society, spoofing attacks are becoming a seriousconcern. Many solutions have been proposed to detect the use offake "fingerprints" on an acquisition device. In this paper, wepropose to take advantage of intrinsic features of friction ridgeskin: pores. The aim of this study is to investigate the potential ofusing pores to detect spoofing attacks.Results show that the use of pores is a promising approach. Fourmajor observations were made: First, results confirmed that thereproduction of pores on fake "fingerprints" is possible. Second,the distribution of the total number of pores between fake andgenuine fingerprints cannot be discriminated. Third, thedifference in pore quantities between a query image and areference image (genuine or fake) can be used as a discriminatingfactor in a linear discriminant analysis. In our sample, theobserved error rates were as follows: 45.5% of false positive (thefake passed the test) and 3.8% of false negative (a genuine printhas been rejected). Finally, the performance is improved byusing the difference of pore quantity obtained between adistorted query fingerprint and a non-distorted referencefingerprint. By using this approach, the error rates improved to21.2% of false acceptation rate and 8.3% of false rejection rate.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Here we present a one-tube nested PCR test, which allows the detection of minimal quantities of Chlamydia trachomatis in human fluids. This assay includes the use of an internal control to avoid false negative results due to the presence of inhibitors. The results obtained show that this assay is robust enough to be used for clinical diagnosis.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: The optimal coronary MR angiography sequence has yet to be determined. We sought to quantitatively and qualitatively compare four coronary MR angiography sequences. SUBJECTS AND METHODS. Free-breathing coronary MR angiography was performed in 12 patients using four imaging sequences (turbo field-echo, fast spin-echo, balanced fast field-echo, and spiral turbo field-echo). Quantitative comparisons, including signal-to-noise ratio, contrast-to-noise ratio, vessel diameter, and vessel sharpness, were performed using a semiautomated analysis tool. Accuracy for detection of hemodynamically significant disease (> 50%) was assessed in comparison with radiographic coronary angiography. RESULTS: Signal-to-noise and contrast-to-noise ratios were markedly increased using the spiral (25.7 +/- 5.7 and 15.2 +/- 3.9) and balanced fast field-echo (23.5 +/- 11.7 and 14.4 +/- 8.1) sequences compared with the turbo field-echo (12.5 +/- 2.7 and 8.3 +/- 2.6) sequence (p < 0.05). Vessel diameter was smaller with the spiral sequence (2.6 +/- 0.5 mm) than with the other techniques (turbo field-echo, 3.0 +/- 0.5 mm, p = 0.6; balanced fast field-echo, 3.1 +/- 0.5 mm, p < 0.01; fast spin-echo, 3.1 +/- 0.5 mm, p < 0.01). Vessel sharpness was highest with the balanced fast field-echo sequence (61.6% +/- 8.5% compared with turbo field-echo, 44.0% +/- 6.6%; spiral, 44.7% +/- 6.5%; fast spin-echo, 18.4% +/- 6.7%; p < 0.001). The overall accuracies of the sequences were similar (range, 74% for turbo field-echo, 79% for spiral). Scanning time for the fast spin-echo sequences was longest (10.5 +/- 0.6 min), and for the spiral acquisitions was shortest (5.2 +/- 0.3 min). CONCLUSION: Advantages in signal-to-noise and contrast-to-noise ratios, vessel sharpness, and the qualitative results appear to favor spiral and balanced fast field-echo coronary MR angiography sequences, although subjective accuracy for the detection of coronary artery disease was similar to that of other sequences.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: The early detection of medullary thyroid carcinoma (MTC) can improve patient prognosis, because histological stage and patient age at diagnosis are highly relevant prognostic factors. As a consequence, delay in the diagnosis and/or incomplete surgical treatment should correlate with a poorer prognosis for patients. Few papers have evaluated the specific capability of fine-needle aspiration cytology (FNAC) to detect MTC, and small series have been reported. This study conducts a meta-analysis of published data on the diagnostic performance of FNAC in MTC to provide more robust estimates. RESEARCH DESIGN AND METHODS: A comprehensive computer literature search of the PubMed/MEDLINE, Embase and Scopus databases was conducted by searching for the terms 'medullary thyroid' AND 'cytology', 'FNA', 'FNAB', 'FNAC', 'fine needle' or 'fine-needle'. The search was updated until 21 March 2014, and no language restrictions were used. RESULTS: Fifteen relevant studies and 641 MTC lesions that had undergone FNAC were included. The detection rate (DR) of FNAC in patients with MTC (diagnosed as 'MTC' or 'suspicious for MTC') on a per lesion-based analysis ranged from 12·5% to 88·2%, with a pooled estimate of 56·4% (95% CI: 52·6-60·1%). The included studies were statistically heterogeneous in their estimates of DR (I-square >50%). Egger's regression intercept for DR pooling was 0·03 (95% CI: -3·1 to 3·2, P = 0·9). The study that reported the largest MTC series had a DR of 45%. Data on immunohistochemistry for calcitonin in diagnosing MTC were inconsistent for the meta-analysis. CONCLUSIONS: The presented meta-analysis demonstrates that FNAC is able to detect approximately one-half of MTC lesions. These findings suggest that other techniques may be needed in combination with FNAC to diagnose MTC and avoid false negative results.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Reconstructive procedures after resection of nasal basal cell carcinoma (BCC) vary depending on the subunit involved. The aim of the present study was to assess the influence of the location of the BCC on the rate of incomplete excisions, so we made a retrospective analysis of all nasal BCC excised at our hospital between 2002 and 2005. The incomplete excision rate was 24/148 (16%). More incomplete excision occurred on the alae (n=13) when compared to the dorsum (n=2) of the nose (p<0.05). Eight two-staged procedures resulted in incomplete resection, whereas 9 (6%) frozen section analyses were false-negative. BCC were most likely to be incompletely excised on the nasal tip and alae, and both subunits required more elaborate reconstructions. This, however, was not the result of poor estimation of the extent of the tumour and reluctance to excise more challenging areas widely for reconstruction, but to the method chosen to eradicate the tumour.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background. The use of hospital discharge administrative data (HDAD) has been recommended for automating, improving, even substituting, population-based cancer registries. The frequency of false positive and false negative cases recommends local validation. Methods. The aim of this study was to detect newly diagnosed, false positive and false negative cases of cancer from hospital discharge claims, using four Spanish population-based cancer registries as the gold standard. Prostate cancer was used as a case study. Results. A total of 2286 incident cases of prostate cancer registered in 2000 were used for validation. In the most sensitive algorithm (that using five diagnostic codes), estimates for Sensitivity ranged from 14.5% (CI95% 10.3-19.6) to 45.7% (CI95% 41.4-50.1). In the most predictive algorithm (that using five diagnostic and five surgical codes) Positive Predictive Value estimates ranged from 55.9% (CI95% 42.4-68.8) to 74.3% (CI95% 67.0-80.6). The most frequent reason for false positive cases was the number of prevalent cases inadequately considered as newly diagnosed cancers, ranging from 61.1% to 82.3% of false positive cases. The most frequent reason for false negative cases was related to the number of cases not attended in hospital settings. In this case, figures ranged from 34.4% to 69.7% of false negative cases, in the most predictive algorithm. Conclusions. HDAD might be a helpful tool for cancer registries to reach their goals. The findings suggest that, for automating cancer registries, algorithms combining diagnoses and procedures are the best option. However, for cancer surveillance purposes, in those cancers like prostate cancer in which care is not only hospital-based, combining inpatient and outpatient information will be required.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to determine the impact of the learning curve on the diagnostic performances of CT colonography. Two blinded teams, each having a radiologist and gastroenterologist, prospectively examined 50 patients using helical CT scan followed by colonoscopy. Intermediate data evaluation was performed after 24 data sets (group 1) and compared with data from 26 subsequent patients (group 2). Parameters evaluated included sensitivity, specificity, false-positive and false-negative findings, time of data acquisition and interpretation. Using colonoscopy as the gold standard, sensitivity for CT colonography was for lesions >5 mm 63% for both teams for group 1 patients; for group 2 patients sensitivity was 45% for team 1 and 64% for team 2. Specificity per patients was for patient group 1 42% for team 1 and 58% for team 2; for patient group 2 it was 79% for both teams ( p=0.04 for team 1; p=0.2 for team 2). Comparing group 1 with group 2, the number of false-positive findings decreased significantly ( p=0.02). Furthermore, the mean time of data evaluation decreased from 45 to 17 min ( p=0.002) and the mean time of data acquisition from 19 to 17 min. With increasing experience, specificity and the time required for data interpretation improved and false positives decreased. There was no significant change of sensitivity, false-negative findings and time of data acquisition. A minimum experience of the readers is required for data interpretation of CT colonography.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Stool is chemically complex and the extraction of DNA from stool samples is extremely difficult. Haemoglobin breakdown products, such as bilirubin, bile acids and mineral ions, that are present in the stool samples, can inhibit DNA amplification and cause molecular assays to produce false-negative results. Therefore, stool storage conditions are highly important for the diagnosis of intestinal parasites and other microorganisms through molecular approaches. In the current study, stool samples that were positive for Giardia intestinalis were collected from five different patients. Each sample was stored using one out of six different storage conditions [room temperature (RT), +4ºC, -20ºC, 70% alcohol, 10% formaldehyde or 2.5% potassium dichromate] for DNA extraction procedures at one, two, three and four weeks. A modified QIAamp Stool Mini Kit procedure was used to isolate the DNA from stored samples. After DNA isolation, polymerase chain reaction (PCR) amplification was performed using primers that target the β-giardin gene. A G. intestinalis-specific 384 bp band was obtained from all of the cyst-containing stool samples that were stored at RT, +4ºC and -20ºC and in 70% alcohol and 2.5% potassium dichromate; however, this band was not produced by samples that had been stored in 10% formaldehyde. Moreover, for the stool samples containing trophozoites, the same G. intestinalis-specific band was only obtained from the samples that were stored in 2.5% potassium dichromate for up to one month. As a result, it appears evident that the most suitable storage condition for stool samples to permit the isolation of G. intestinalis DNA is in 2.5% potassium dichromate; under these conditions, stool samples may be stored for one month.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this study, we evaluated several techniques for the detection of the yeast form of Cryptococcus in decaying wood and measured the viability of these fungi in environmental samples stored in the laboratory. Samples were collected from a tree known to be positive for Cryptococcus and were each inoculated on 10 Niger seed agar (NSA) plates. The conventional technique (CT) yielded a greater number of positive samples and indicated a higher fungal density [in colony forming units per gram of wood (CFU.g-1)] compared to the humid swab technique (ST). However, the difference in positive and false negative results between the CT-ST was not significant. The threshold of detection for the CT was 0.05.10³ CFU.g-1, while the threshold for the ST was greater than 0.1.10³ CFU-1. No colonies were recovered using the dry swab technique. We also determined the viability of Cryptococcus in wood samples stored for 45 days at 25ºC using the CT and ST and found that samples not only continued to yield a positive response, but also exhibited an increase in CFU.g-1, suggesting that Cryptococcus is able to grow in stored environmental samples. The ST.1, in which samples collected with swabs were immediately plated on NSA medium, was more efficient and less laborious than either the CT or ST and required approximately 10 min to perform; however, additional studies are needed to validate this technique.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We evaluated the use of a newly described sodC-based real-time-polymerase chain reaction (RT-PCR) assay for detecting Neisseria meningitidis in normally sterile sites, such as cerebrospinal fluid and serum. The sodC-based RT-PCR assay has an advantage over ctrA for detecting nongroupable N. meningitidis isolates, which are commonly present in asymptomatic pharyngeal carriage. However, in our study, sodC-based RT-PCR was 7.5% less sensitive than ctrA. Given the public health impact of possible false-negative results due to the use of the sodC target gene alone, sodC-based RT-PCR for the diagnosis of meningococcal meningitis should be used with caution.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Mice experimentally infected with a pathogenic strain of Leptospira interrogans serovar Canicola produced false negative results (prozone effect) in a microscopic agglutination test (MAT). This prozone effect occurred in several serum samples collected at different post-infection times, but it was more prominent in samples collected from seven-42 days post-infection and for 1:50 and 1:100 sample dilutions. This phenomenon was correlated with increased antibody titres in the early post-infection phase. While prozone effects are often observed in serological agglutination assays for the diagnosis of animal brucellosis and human syphilis, they are not widely reported in leptospirosis MATs.