984 resultados para evaluation designs


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Bacterial leakage along the implant-abutment interface, with consequent species harboring the inner parts of two-part dental implant systems, has been reported in the literature. The aim of this in vitro study was to evaluate bacterial leakage from human saliva to the internal part of the implants along the implant-abutment interface under loaded and unloaded conditions using DNA Checkerboard. Materials and Methods: Sixty denial implants-20 each of external-hexagon, internal-hexagon, and Morse cone-connection designs-and their conical abutments were used in this study. Each group was subdivided into two groups of 10 loaded and 10 unloaded implants. The assemblies were immersed in human saliva and either (1) loaded with 500,000 cycles at 120 N (experimental group) or (2) incubated in static conditions for 7 days at 35 degrees C (unloaded control group). Results: Microorganisms were found in the internal surfaces of all types of connections. The Morse cone connection presented the lowest count of microorganisms in both the unloaded and loaded groups. Loaded implants presented with higher counts of microorganisms than unloaded implants for external- and internal-hex connections. Conclusion: Bacterial species from human saliva may penetrate along the implant-abutment interface under both unloaded and loaded conditions for all connections evaluated. Morse cone-connection implants showed the lowest counts of microorganisms for both conditions. External- and internal-hex implants showed a higher incidence of bacteria and higher bacterial counts after simulated loading. INT J ORAL MAXILLOFAC IMPLANTS 2012;27:551-560.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this research was to test the hypothesis that treatment with intra-oral appliances with different occlusal designs was beneficial in the management of pain of masticatory muscles compared with a control group. A total of 51 patients were analysed according to the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) to obtain the diagnosis of masticatory myofascial pain (MMP). The sample was then randomly divided into three groups: group I (n = 21) wore a full coverage acrylic stabilisation occlusal splint; group II (n = 16) wore an anterior device nociceptive trigeminal inhibitory (NTI) system; and group III (n = 14) only received counselling for behavioural changes and self-care (the control group). The first two groups also received counselling. Follow-ups were performed after 2 and 6 weeks and 3 months. In these sessions, patients were evaluated by means of a visual analogue scale (VAS) and pressure pain threshold (PPT) of the masticatory muscles. Possible adverse effects were also recorded, such as discomfort while using the appliance and occlusal changes. The results were analysed with KruskalWallis, anova, Tukeys and Friedman tests, with a significance level of 5%. Group I showed improvement in the reported pain at the first follow-up (2 weeks), whereas for groups II and III, this progress was detected only after 6 weeks and 3 months, respectively. The PPT values did not change significantly. It was concluded that behavioural changes are effective in the management of pain in MMP patients. However, the simultaneous use of occlusal devices appears to produce an earlier improvement.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: Because the mechanical behavior of the implant-abutment system is critical for the longevity of implant-supported reconstructions, this study evaluated the fatigue reliability of different implant-abutment systems used as single-unit crowns and their failure modes. Methods and Materials: Sixty-three Ti-6Al-4V implants were divided in 3 groups: Replace Select (RS); IC-IMP Osseotite; and Unitite were restored with their respective abutments. Anatomically correct central incisor metal crowns were cemented and subjected to separate single load to failure tests and step-stress accelerated life testing (n = 18). A master Weibull curve and reliability for a mission of 50,000 cycles at 200 N were calculated. Polarized-light and scanning electron microscopes were used for failure analyses. Results: The load at failure mean values during step-stress accelerated life testing were 348.14 N for RS, 324.07 N for Osseotite, and 321.29 N for the Unitite systems. No differences in reliability levels were detected between systems, and only the RS system mechanical failures were shown to be accelerated by damage accumulation. Failure modes differed between systems. Conclusions: The 3 evaluated systems did not present significantly different reliability; however, failure modes were different. (Implant Dent 2012;21:67-71)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Implant-abutment connections still present failures in the oral cavity due to the loosening of mechanical integrity by detorque and corrosion of the abutment screws. The objective of this study was to evaluate the detorque of dental abutment screws before and after immersion in fluoridated solutions. Materials and Methods: Five commercial implant-abutment assemblies were assessed in this investigation: (C) Conex˜aoR , (E) EmfilsR , (I) INPR , (S) SINR , and (T) Titanium FixR . The implants were embedded in an acrylic resin and then placed in a holding device. The abutments were first connected to the implants and torqued to 20Ncmusing a handheld torque meter. The detorque values of the abutments were evaluated after 10 minutes. After applying a second torque of 20 Ncm, implant-abutment assemblies were withdrawn every 3 hours for 12 hours in a fluoridated solution over a period of 90 days. After that period, detorque of the abutments was examined. Scanning electronicmicroscopy (SEM) associated to energy dispersive spectroscopy (EDS) was applied to inspect the surfaces of abutments. Results: Detorque values of systems C, E, and I immersed in the fluoridated solution were significantly higher than those of the initial detorque. ANOVA demonstrated no significant differences in detorque values between designs S and T. Signs of localized corrosion could not be detected by SEM although chemical analysis by EDS showed the presence of elements involved in corrosive processes. Conclusion: An increase of detorque values recorded on abutments after immersion in fluoridated artificial saliva solutions was noticed in this study. Regarding chemical analysis, such an increase of detorque can result from a corrosion layer formed between metallic surfaces at static contact in the implant-abutment joint during immersion in the fluoridated solutions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The scale down of transistor technology allows microelectronics manufacturers such as Intel and IBM to build always more sophisticated systems on a single microchip. The classical interconnection solutions based on shared buses or direct connections between the modules of the chip are becoming obsolete as they struggle to sustain the increasing tight bandwidth and latency constraints that these systems demand. The most promising solution for the future chip interconnects are the Networks on Chip (NoC). NoCs are network composed by routers and channels used to inter- connect the different components installed on the single microchip. Examples of advanced processors based on NoC interconnects are the IBM Cell processor, composed by eight CPUs that is installed on the Sony Playstation III and the Intel Teraflops pro ject composed by 80 independent (simple) microprocessors. On chip integration is becoming popular not only in the Chip Multi Processor (CMP) research area but also in the wider and more heterogeneous world of Systems on Chip (SoC). SoC comprehend all the electronic devices that surround us such as cell-phones, smart-phones, house embedded systems, automotive systems, set-top boxes etc... SoC manufacturers such as ST Microelectronics , Samsung, Philips and also Universities such as Bologna University, M.I.T., Berkeley and more are all proposing proprietary frameworks based on NoC interconnects. These frameworks help engineers in the switch of design methodology and speed up the development of new NoC-based systems on chip. In this Thesis we propose an introduction of CMP and SoC interconnection networks. Then focusing on SoC systems we propose: • a detailed analysis based on simulation of the Spidergon NoC, a ST Microelectronics solution for SoC interconnects. The Spidergon NoC differs from many classical solutions inherited from the parallel computing world. Here we propose a detailed analysis of this NoC topology and routing algorithms. Furthermore we propose aEqualized a new routing algorithm designed to optimize the use of the resources of the network while also increasing its performance; • a methodology flow based on modified publicly available tools that combined can be used to design, model and analyze any kind of System on Chip; • a detailed analysis of a ST Microelectronics-proprietary transport-level protocol that the author of this Thesis helped developing; • a simulation-based comprehensive comparison of different network interface designs proposed by the author and the researchers at AST lab, in order to integrate shared-memory and message-passing based components on a single System on Chip; • a powerful and flexible solution to address the time closure exception issue in the design of synchronous Networks on Chip. Our solution is based on relay stations repeaters and allows to reduce the power and area demands of NoC interconnects while also reducing its buffer needs; • a solution to simplify the design of the NoC by also increasing their performance and reducing their power and area consumption. We propose to replace complex and slow virtual channel-based routers with multiple and flexible small Multi Plane ones. This solution allows us to reduce the area and power dissipation of any NoC while also increasing its performance especially when the resources are reduced. This Thesis has been written in collaboration with the Advanced System Technology laboratory in Grenoble France, and the Computer Science Department at Columbia University in the city of New York.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Surgery and other invasive therapies are complex interventions, the assessment of which is challenged by factors that depend on operator, team, and setting, such as learning curves, quality variations, and perception of equipoise. We propose recommendations for the assessment of surgery based on a five-stage description of the surgical development process. We also encourage the widespread use of prospective databases and registries. Reports of new techniques should be registered as a professional duty, anonymously if necessary when outcomes are adverse. Case series studies should be replaced by prospective development studies for early technical modifications and by prospective research databases for later pre-trial evaluation. Protocols for these studies should be registered publicly. Statistical process control techniques can be useful in both early and late assessment. Randomised trials should be used whenever possible to investigate efficacy, but adequate pre-trial data are essential to allow power calculations, clarify the definition and indications of the intervention, and develop quality measures. Difficulties in doing randomised clinical trials should be addressed by measures to evaluate learning curves and alleviate equipoise problems. Alternative prospective designs, such as interrupted time series studies, should be used when randomised trials are not feasible. Established procedures should be monitored with prospective databases to analyse outcome variations and to identify late and rare events. Achievement of improved design, conduct, and reporting of surgical research will need concerted action by editors, funders of health care and research, regulatory bodies, and professional societies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

While navigation systems for cars are in widespread use, only recently, indoor navigation systems based on smartphone apps became technically feasible. Hence tools in order to plan and evaluate particular designs of information provision are needed. Since tests in real infrastructures are costly and environmental conditions cannot be held constant, one must resort to virtual infrastructures. This paper presents the development of an environment for the support of the design of indoor navigation systems whose center piece consists in a hands-free navigation method using the Microsoft Kinect in the four-sided Definitely Affordable Virtual Environment (DAVE). Navigation controls using the user's gestures and postures as the input to the controls are designed and implemented. The installation of expensive and bulky hardware like treadmills is avoided while still giving the user a good impression of the distance she has traveled in virtual space. An advantage in comparison to approaches using a head mounted display is that the DAVE allows the users to interact with their smartphone. Thus the effects of different indoor navigation systems can be evaluated already in the planning phase using the resulting system

Relevância:

30.00% 30.00%

Publicador:

Resumo:

During the last years two studies for the investigation of the etiology of porcine ear necrosis were carried out at the Clinic for Swine of the University of Veterinary Medicine Vienna. In study 1, parameters, which are discussed in this context, were collected by veterinary practitioners by completing specially designed questionnaires in farms with symptoms of the porcine ear necrosis syndrome. In study 2, samples of piglets and feed were collected for laboratory analysis of the most important infectious agents as well as mycotoxins. In the present manuscript, the results of both projects were compared. Even if the selection criteria of both studies differed, the affected age class was comparable (5.5 to ten weeks of life in study 1 and six to ten weeks of life in study 2). The herd-specific prevalence of the porcine ear necrosis syndrome varied considerably with percentages between 2 and 10, respectively, to 100%. The evaluation of questionnaires in study 1 showed that 51% of the farms had problems with cannibalism. Particles of plant material, which were frequently seen on the histologic slides of study 2, could have got into the tissue by chewing the ears of the pen mates or cannibalism. Whereas in study 1 the negative effect of parameters as high pig density, suboptimal climate, missing enrichment material and bad quality of feed and water were considered, in study 2 all these factors were checked at sample collection and ruled out as precursor for cannibalism. In both studies bacterial agents proved to be a crucial co-factor for the expansion of the necroses to deeper tissue layers, whereas viral pathogens were classified less important. In both projects it was not possible to estimate the direct impact of infectious agents and mycotoxins as direct trigger of the necroses as well as their participation as co-factors or precursor in the sense of an immunosuppression or previous damage of blood vessels or tissue.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Self-administered online surveys provide a higher level of privacy protection to respondents than surveys administered by an interviewer. Yet, studies indicate that asking sensitive questions is problematic also in self-administered surveys. Because respondents might not be willing to reveal the truth and provide answers that are subject to social desirability bias, the validity of prevalence estimates of sensitive behaviors from online surveys can be challenged. A well-known method to overcome these problems is the Randomized Response Technique (RRT). However, convincing evidence that the RRT provides more valid estimates than direct questioning in online surveys is still lacking. A new variant of the RRT called the Crosswise Model has recently been proposed to overcome some of the deficiencies of existing RRT designs. We therefore conducted an experimental study in which different implementations of the RRT, including two implementations of the crosswise model, were tested and compared to direct questioning. Our study is a large-scale online survey (N = 6,037) on sensitive behaviors by students such as cheating in exams and plagiarism. Results indicate that the crosswise-model RRT---unlike the other variants of RRT we evaluated---yields higher prevalence estimates of sensitive behaviors than direct questioning. Whether higher estimates are a sufficient condition for more valid results, however, remains questionable.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

When conducting a randomized comparative clinical trial, ethical, scientific or economic considerations often motivate the use of interim decision rules after successive groups of patients have been treated. These decisions may pertain to the comparative efficacy or safety of the treatments under study, cost considerations, the desire to accelerate the drug evaluation process, or the likelihood of therapeutic benefit for future patients. At the time of each interim decision, an important question is whether patient enrollment should continue or be terminated; either due to a high probability that one treatment is superior to the other, or a low probability that the experimental treatment will ultimately prove to be superior. The use of frequentist group sequential decision rules has become routine in the conduct of phase III clinical trials. In this dissertation, we will present a new Bayesian decision-theoretic approach to the problem of designing a randomized group sequential clinical trial, focusing on two-arm trials with time-to-failure outcomes. Forward simulation is used to obtain optimal decision boundaries for each of a set of possible models. At each interim analysis, we use Bayesian model selection to adaptively choose the model having the largest posterior probability of being correct, and we then make the interim decision based on the boundaries that are optimal under the chosen model. We provide a simulation study to compare this method, which we call Bayesian Doubly Optimal Group Sequential (BDOGS), to corresponding frequentist designs using either O'Brien-Fleming (OF) or Pocock boundaries, as obtained from EaSt 2000. Our simulation results show that, over a wide variety of different cases, BDOGS either performs at least as well as both OF and Pocock, or on average provides a much smaller trial. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

With continuous new improvements in brachytherapy source designs and techniques, method of 3D dosimetry for treatment dose verifications would better ensure accurate patient radiotherapy treatment. This study was aimed to first evaluate the 3D dose distributions of the low-dose rate (LDR) Amersham 6711 OncoseedTM using PRESAGE® dosimeters to establish PRESAGE® as a suitable brachytherapy dosimeter. The new AgX100 125I seed model (Theragenics Corporation) was then characterized using PRESAGE® following the TG-43 protocol. PRESAGE® dosimeters are solid, polyurethane-based, 3D dosimeters doped with radiochromic leuco dyes that produce a linear optical density response to radiation dose. For this project, the radiochromic response in PRESAGE® was captured using optical-CT scanning (632 nm) and the final 3D dose matrix was reconstructed using the MATLAB software. An Amersham 6711 seed with an air-kerma strength of approximately 9 U was used to irradiate two dosimeters to 2 Gy and 11 Gy at 1 cm to evaluate dose rates in the r=1 cm to r=5 cm region. The dosimetry parameters were compared to the values published in the updated AAPM Report No. 51 (TG-43U1). An AgX100 seed with an air-kerma strength of about 6 U was used to irradiate two dosimeters to 3.6 Gy and 12.5 Gy at 1 cm. The dosimetry parameters for the AgX100 were compared to the values measured from previous Monte-Carlo and experimental studies. In general, the measured dose rate constant, anisotropy function, and radial dose function for the Amersham 6711 showed agreements better than 5% compared to consensus values in the r=1 to r=3 cm region. The dose rates and radial dose functions measured for the AgX100 agreed with the MCNPX and TLD-measured values within 3% in the r=1 to r=3 cm region. The measured anisotropy function in PRESAGE® showed relative differences of up to 9% with the MCNPX calculated values. It was determined that post-irradiation optical density change over several days was non-linear in different dose regions, and therefore the dose values in the r=4 to r=5 cm regions had higher uncertainty due to this effect. This study demonstrated that within the radial distance of 3 cm, brachytherapy dosimetry in PRESAGE® can be accurate within 5% as long as irradiation times are within 48 hours.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recently, methods for computing D-optimal designs for population pharmacokinetic studies have become available. However there are few publications that have prospectively evaluated the benefits of D-optimality in population or single-subject settings. This study compared a population optimal design with an empirical design for estimating the base pharmacokinetic model for enoxaparin in a stratified randomized setting. The population pharmacokinetic D-optimal design for enoxaparin was estimated using the PFIM function (MATLAB version 6.0.0.88). The optimal design was based on a one-compartment model with lognormal between subject variability and proportional residual variability and consisted of a single design with three sampling windows (0-30 min, 1.5-5 hr and 11 - 12 hr post-dose) for all patients. The empirical design consisted of three sample time windows per patient from a total of nine windows that collectively represented the entire dose interval. Each patient was assigned to have one blood sample taken from three different windows. Windows for blood sampling times were also provided for the optimal design. Ninety six patients were recruited into the study who were currently receiving enoxaparin therapy. Patients were randomly assigned to either the optimal or empirical sampling design, stratified for body mass index. The exact times of blood samples and doses were recorded. Analysis was undertaken using NONMEM (version 5). The empirical design supported a one compartment linear model with additive residual error, while the optimal design supported a two compartment linear model with additive residual error as did the model derived from the full data set. A posterior predictive check was performed where the models arising from the empirical and optimal designs were used to predict into the full data set. This revealed the optimal'' design derived model was superior to the empirical design model in terms of precision and was similar to the model developed from the full dataset. This study suggests optimal design techniques may be useful, even when the optimized design was based on a model that was misspecified in terms of the structural and statistical models and when the implementation of the optimal designed study deviated from the nominal design.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We describe a tool for analysing information flow in security hardware. It identifies both sub-circuits critical to the preservation of security as well as the potential for information flow due to hardware failure. The tool allows for the composition of both logical and physical views of circuit designs. An example based on a cryptographic device is provided.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: To evaluate the accuracy of an open-field autorefractor compared with subjective refraction in pseudophakes and hence its ability to assess objective eye focus with intraocular lenses (IOLs). Methods: Objective refraction was measured at 6 m using the Shin-Nippon NVision-K 5001/Grand Seiko WR-5100K open-field autorefractor (five repeats) and by subjective refraction on 141 eyes implanted with a spherical (Softec1 n=53), aspherical (SoftecHD n=37) or accommodating (1CU n=22; Tetraflex n=29) IOL. Autorefraction was repeated 2 months later. Results: The autorefractor prescription was similar (average difference: 0.09±0.53 D; p=0.19) to that found by subjective refraction, with ~71% within ±0.50 D. The horizontal cylindrical components were similar (difference: 0.00±0.39 D; p=0.96), although the oblique (J45) autorefractor cylindrical vector was slightly more negative (by -0.06±0.25 D; p=0.06) than the subjective refraction. The results were similar for each of the IOL designs except for the spherical IOL, where the mean spherical equivalent difference between autorefraction and subjective was more hypermetropic than the Tetraflex accommodating IOL (F=2.77, p=0.04). The intrasession repeatability was

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The evaluation and selection of industrial projects before investment decision is customarily done using marketing, technical and financial information. Subsequently, environmental impact assessment and social impact assessment are carried out mainly to satisfy the statutory agencies. Because of stricter environment regulations in developed and developing countries, quite often impact assessment suggests alternate sites, technologies, designs, and implementation methods as mitigating measures. This causes considerable delay to complete project feasibility analysis and selection as complete analysis requires to be taken up again and again till the statutory regulatory authority approves the project. Moreover, project analysis through above process often results sub-optimal project as financial analysis may eliminate better options, as more environment friendly alternative will always be cost intensive. In this circumstance, this study proposes a decision support system, which analyses projects with respect to market, technicalities, and social and environmental impact in an integrated framework using analytic hierarchy process, a multiple-attribute decision-making technique. This not only reduces duration of project evaluation and selection, but also helps select optimal project for the organization for sustainable development. The entire methodology has been applied to a cross-country oil pipeline project in India and its effectiveness has been demonstrated. © 2005 Elsevier B.V. All rights reserved.