939 resultados para equivalent web thickness method


Relevância:

40.00% 40.00%

Publicador:

Resumo:

formula for the thickness of a shear band formed in saturated soils under a simple shear or a combined stress state has been proposed. It is shown that the shear band thickness is dependent on the pore pressure properties of the material and the dilatancy rate, but is independent of the details of the combined stress state. This is in accordance with some separate experimental observations.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

For an orthotropic laminate, an equivalent system with doubly cyclic periodicity is introduced. Then a 3-dimensional finite element model for the equivalent system is transformed into the unitary space, where the large finite element matrix equation is decoupled into some small matrix equations. Such a decoupling very efficiently reduces the computational effort. For an orthotropic laminate with four clamped edges, no exact elasticity solution is available, and the deflection values predicted by different methods have a considerable difference each other for a small length-to-thickness ratio. The present predictions are the largest because the present method is a full 3-dimensional finite element analysis without superfluous constraints. Illustrative numerical examples are presented to observe the distributions of stresses through the thickness of the laminates. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In resin transfer molding processes, small clearances exist between the fiber preform and the mold edges, which result in a preferential resin flow in the edge channel and then disrupt the flow patterns during the mold filling stage. A mathematical model including the effect of cavity thickness on resin flow was developed for flow behavior involving the interface between an edge channel and a porous medium. According to the mathematical analysis of momentum equations in a fully developed rectangular duct and formulations of the equivalent edge permeability, comparing with three-dimensional Navier-Stokes equations, the governing equations were modified in the edge channel. The volume of fluid (VOF) method was applied to track the flow front. A simple case is numerically simulated using the modified governing equations. The effects of edge channel width and cavity thickness on flow front and inlet pressure are analyzed, and the evolution characteristics of simulated results are in agreement with the experimental results. (c) 2007 Elsevier B.V. All rights reserved

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Adhesive bonding is nowadays a serious candidate to replace methods such as fastening or riveting, because of attractive mechanical properties. As a result, adhesives are being increasingly used in industries such as the automotive, aerospace and construction. Thus, it is highly important to predict the strength of bonded joints to assess the feasibility of joining during the fabrication process of components (e.g. due to complex geometries) or for repairing purposes. This work studies the tensile behaviour of adhesive joints between aluminium adherends considering different values of adherend thickness (h) and the double-cantilever beam (DCB) test. The experimental work consists of the definition of the tensile fracture toughness (GIC) for the different joint configurations. A conventional fracture characterization method was used, together with a J-integral approach, that take into account the plasticity effects occurring in the adhesive layer. An optical measurement method is used for the evaluation of crack tip opening and adherends rotation at the crack tip during the test, supported by a Matlab® sub-routine for the automated extraction of these quantities. As output of this work, a comparative evaluation between bonded systems with different values of adherend thickness is carried out and complete fracture data is provided in tension for the subsequent strength prediction of joints with identical conditions.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This work presents detailed numerical calculations of the dielectrophoretic force in octupolar traps designed for single-cell trapping. A trap with eight planar electrodes is studied for spherical and ellipsoidal particles using an indirect implementation of the boundary element method (BEM). Multipolar approximations of orders one to three are compared with the full Maxwell stress tensor (MST) calculation of the electrical force on spherical particles. Ellipsoidal particles are also studied, but in their case only the dipolar approximation is available for comparison with the MST solution. The results show that the full MST calculation is only required in the study of non-spherical particles.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Web service composition can be facilitated by an automatic process which consists of rules, conditions and actions. This research has adapted ElementaryPetri Net (EPN) to analyze and model the web services and their composition. This paper describes a set of techniques for representing transition rules, algorithm and workflow that web service composition can be automatically carried out.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A sampling oscilloscope is one of the main units in automatic pulse measurement system (APMS). The time jitter in waveform samplers is an important error source that affect the precision of data acquisition. In this paper, this kind of error is greatly reduced by using the deconvolution method. First, the probability density function (PDF) of time jitter distribution is determined by the statistical approach, then, this PDF is used as convolution kern to deconvolve with the acquired waveform data with additional averaging, and the result is the waveform data in which the effect of time jitter has been removed, and the measurement precision of APMS is greatly improved. In addition, some computer simulations are given which prove the success of the method given in this paper.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this paper is to present a simple method for determining the high frequency parameters of a three-phase induction motor to be used in studies involving variable speed drives with PWM three-phase inverters, in which it is necessary to check the effects caused to the motor by the electromagnetic interference, (EMI) in the differential mode, as well as in the common mode. The motor parameters determination is generally performed in adequate laboratories using accurate instruments, such as very expensive RLC bridges. The method proposed here consists in the identification of the motor equivalent electrical circuit parameters in rated frequency and in high frequency through characteristic tests in the laboratory, together with the use of characteristic equations and curves, shown in the references to be mentioned for determining the motor high frequency parasite capacitances and also through system simulations using dedicated software, like Pspice, determining the characteristic waveforms involved in the differential and common mode phenomena, comparing and validating the procedure through published papers [01].

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: This study evaluated the influence of polymerization cycle and thickness of maxillary complete denture bases on the porosity of acrylic resin. Materials and Methods: Two heat-activated denture base resins - one conventional (Clássico) and one designed for microwave polymerization (Onda-Cryl) - were used. Four groups were established, according to polymerization cycles: A (Onda-Cryl, short microwave cycle), B (Onda-Cryl, long microwave cycle), C (Onda-Cryl, manufacturing microwave cycle), and T (Clássico, water bath). Porosity was evaluated for different thicknesses (2.0, 3.5, and 5.0 mm; thicknesses I, II, and III, respectively) by measurement of the specimen volume before and after its immersion in water. The percent porosity data were submitted to Kruskal-Wallis for comparison among the groups. Results: The Kruskal-Wallis test detected that the combinations of the different cycles and thicknesses showed significant differences, and the mean ranks of percent porosity showed differences only in the thinnest (2.0 mm) microwave-polymerized specimens (A = 53.55, B = 40.80, and C = 90.70). Thickness did not affect the results for cycle T (I = 96.15, II = 70.20, and III = 82.70), because porosity values were similar in the three thicknesses. Conclusions: Microwave polymerization cycles and the specimen thickness of acrylic resin influenced porosity. Porosity differences were not observed in the polymerized resin bases in the water bath cycle for any thickness. © 2007 by The American College of Prosthodontists.