986 resultados para equipamento aplicador
Resumo:
Almost forty years computed tomography (CT) has been one of the most powerful tools in diagnostic imaging. However, this modality delivers relatively high doses to their patients. It is known that the inappropriate use and unnecessary radiation may be associated with a significant risk of cancer, especially in pediatric patients. Moreover, the quality assurance in CT, provided and required by Portaria 453/98 and the guide of the RE 1016/05, ensures that the images generated by computer tomography provide reliable diagnostic information with doses as low as reasonably achievable. This research aimed to make the quality control (QC) of CT equipment; establish a better relationship between dose and noise on the image to protocols of skull CT according to the study of optimization proposed in 2005 by Daros; and assess the dose distribution in different cranial organs for protocols of adult and pediatric use in the routine of the Department of Diagnostic Imaging of HCFMB-UNESP. The equipment used for testing QC, optimization and dosimetry was a third generation tomograph GE Sytec 3000i
Resumo:
Nowadays, there is a need for improvements in production processes for companies to be competitive, as it is an obligation of businesses, it is necessary to know about the production processes accurately, to learn where improvements in work and thus have large impacts results. The calculation of efficiency of production lines is necessary to know as much about the progress of production and for product costing, when the measurement is not suitable, it generates negative impacts on the company. Due to the impact generated by this parameter, the graduation work carry out the study of change in a method that does not include all requirements necessary, by another method known as Overall Equipment Effectiveness, and according to studies, covering various parameters, showing become more consistent. These values are contained in the pattern production which is used to fund the product, thereby also occur financial impacts. Thus the work will study the change along with the analysis of impacts caused by the change
Resumo:
O estágio realizado em parceria entre o Departamento de Física e Biofísica do IBB-UNESP e o Hemocentro de Botucatu da FMB-UNESP teve como objetivo desenvolver um novo equipamento de luz LED capaz de interagir com culturas celulares. Desta forma foi desenvolvido um equipamento com luz azul e luz vermelha. A luz azul é responsável por inibir o crescimento celular, a luz vermelha é responsável por aumentar o crescimento celular. O equipamento consiste de uma fonte, e dois conjuntos com três LEDs cada. A cultura celular escolhida foi a de Miemola Murino (NS1), uma linhagem que possui alta taxa de crescimento e que foi mantida em estufa e meio de cultura, (simulando condições normais de sobrevivência), sendo irradiada três vezes ao dia. As amostras foram coletadas e contadas em câmara de Neubauer. Os resultados obtidos, quando comparados com o controle, não apresentaram significativa diferença de crescimento quando irradiados com luz LED vermelho. Porém quando comparados o grupo controle com o grupo irradiado com LED azul, notou-se uma significativa redução da quantidade de células a partir do sétimo dia de irradiação. Acredita-se que a ineficácia dos LEDs vermelhos ocorreram pois utilizamos células com metabolismo bastante elevado, dificultando um aumento ainda maior da taxa de crescimento. A redução da população de células azuis ocorre pois a radiação interage com a membrana celular, causando a quebra dessa membrana e conseqüente morte da célula. Outra via para a morte é a lesão causada no DNA das células, que ocorre quando a luz azul é absorvida pela molécula
Resumo:
In the industrial environment the challenge is use better the productive resources: people and machine. The following work has the main goal improve the efficient losses analysis in the stator bar’s production bottleneck equipment situated in the Electric generator’s factory. The action research involved Theory of Constraints on the restriction system identification and developed the data collection framework by losses typology for indicator measurement. The research showed the data collection standardization importance to obtain reliable data and strategic efficiency indicator to optimize equipments. Besides of this, OEE and TEEP indicator demonstrated efficiency results to analyze the actual efficiency when the machine works and the increase capacity opportunity to treat the hide costs in the organization following the continuous improvement
Resumo:
Induction heating is a process closely linked to the concepts of heat transfer. It also covers electromagnetic induction and effect of film. Many companies use this technology in their processes due to the high accuracy that can be obtained at temperatures induced. However the dominance of this technology is not common among Brazilian industries. This involves complex systems of equation and heat exchange in transient conduction, and convection and radiation losses. With this work we seek the ability to analyze which parameters influence over this process and the order of magnitude of time required for heating a cylindrical part
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
Pós-graduação em Medicina Veterinária - FCAV
Resumo:
Pós-graduação em Engenharia Mecânica - FEIS
Resumo:
Pós-graduação em Engenharia Civil - FEIS
Resumo:
Aperfeiçoamento em equipamento para digestão de amostras por via úmida. É descrito um aperfeiçoamento em equipamento para digestão de amostras por via úmida que emprega tubos de digestão (20) fechados não encapsulados e aquecimento condutivo que possibilita a rápida decomposição de amostras botânicas, alimentícias, clínicas, ambientais e similares, promovendo um gradiente de temperatura em direção à parte superior do tubo de digestão, permitindo que a temperatura da fase gasosa seja inferior à da fase líquida, de forma que as digestões são realizadas à pressão pouco elevada e, consequentemente, os tubos de digestão utilizados podem ter paredes menos espessas, permitindo o rápido aquecimento e resfriamento das amostras, bem como baixo custo de operação e manutenção, simplicidade, alta frequência analítica,; redução do consumo de reagentes e diminuição da geração de resíduos, dito equipamento provido de um gabinete (10) que evita a contaminação da atmosfera do laboratório por vapores ácidos e a perda dos componentes voláteis da amostra durante o aquecimento
Resumo:
Equipamento e processo de enriquecimento superficial seletivo de ligas metálicas. É descrito um equipamento e processo de enriquecimento superficial seletivo de ligas metálicas com controle da velocidade e da intensidade do processo, de forma a permitir controlar a espessura da camada enriquecida e a diminuição do tempo necessário para ser obtida camada enriquecida com espessura desejada.
Resumo:
Although they are no longer manufactured, the applicators of 90Sr +90Y acquired in the decades of 1990 are still in use, by having half-life of 28.5 years. These applicators have calibration certificate given by their manufacturers, where few have been recalibrated. Thus it becomes necessary to accomplish thorough dosimetry of these applicators. This paper presents a dosimetric analysis distribution radial dose profiles for emitted by an 90Sr+90Y betatherapy applicator, using the MCNP-4C code to simulate the distribution radial dose profiles and radiochromium films to get them experimentally . The results with the simulated values were compared with the results of experimental measurements, where both curves show similar behavior, which may validate the use of MCNP-4C and radiochromium films for this type of dosimetry
Resumo:
É descrito um equipamento e método para medição de dureza de materiais lignocelulósicos que compreende um equipamento portátil eletromecânico que mede a dureza de materiais, com princípio de funcionamento semelhante ao ensaio de dureza brinell, apresentando um conjunto eletrônico composto por um sensor de deslocamento do tipo encoder magnético incremental que permite a automatização da leitura da dureza por meio de controlador digital de sinais integrado.
Resumo:
This study aimed to establish a calibration model of a TDR equipment to determinate thewood moisture of Grevillea robusta (Cunn.). It was selected alleatory, 11 logs of Grevillea robusta (Cunn.), it was dried in a regulate electric greenhouse at 40o C. During the dry process, the moisture was determinate, periodically and systematically by gravimetric and TDR methods. Through the gravimetric method, moisture vary from 125,88% to 6,62% while the TDR method, the variation was from 119,83% to 5,79%. The best model adjusted to the wood moisture in the determination of the function of relative dielectric constant, using this technique, was the exponential 50,20 132,72 140,27 K U e − = − ⋅ , with a R2 = 0,96, with indicator of trust or performance 0,97 they were classified as very good, according to Camargo and Sentelhas (1997). The correlation between the gravimetric method (reference) and TDR, showed to be equivalent for both methodologies. It was concluded that the TDR can be used to the determination of wood moisture of Grevillea robusta (Cunn.), in a precise and fast way, once it was established it calibration.
Resumo:
Baseado em um controlador digital de sinais, o sistema de monitoramento e detecção da queima em tempo real proposto neste estudo realiza a aquisição das sinais RMS de emissão acústica e da potência ativa do motor de acionamento do rebolo. Essas ações são necessárias para realizar o cálculo de estatísticas que foram utilizadas em trabalhos científicos e mostraram-se eficientes na detecção da queima em processos de retiticação. Dessa forma, é possível atuar sobre a retificadora, interrompendo seu funcionamento ou realizando correções nas variáveis do processo.