990 resultados para equilíbrio líquido-vapor
Resumo:
In the last years, a great interest in nonequilibrium systems has been witnessed. Although the Master Equations are one of the most common methods used to describe these systems, the literature about these equations is not straightforward due to the mathematical framework used in their derivations. The goals of this work are to present the physical concepts behind the Master Equations development and to discuss their basic proprieties via a matrix approach. It is also shown how the Master Equations can be used to model typical nonequilibrium processes like multi-wells chemical reactions and radiation absorption processes.
Resumo:
O objetivo deste estudo foi analisar o equilíbrio muscular dos flexores e extensores (RFE) de joelho ao longo de uma temporada de treinamento em jogadores de futebol categoria sub-20. Fizeram parte da amostra 15 sujeitos pertencentes à equipe sub-20 da Associação Atlética Ponte Preta de Campinas. Os atletas participaram de um macrociclo de preparação (MP) de 29 semanas, composto por período preparatório e competitivo que foram divididos em quatro mesociclos: etapa geral (M1), etapa especial (M2), etapa pré-competitiva (M3) e etapa competitiva (M4). A RFE de ambos os membros foi determinada em dinamômetro isocinético utilizando o pico de torque (PT) obtido em três séries consecutivas de cinco repetições com velocidade de 60º/s. Avaliação isocinética foi realizada em quatro momentos ao longo do MP, sempre ao final de cada mesociclo (M1, M2, M3 e M4). Para análise estatística, foi empregado teste Friedman de medidas repetidas, seguida do teste de Wilcoxon e teste U de Mann-Whitney, com nível de significância de p<0,05. O PT nos músculos flexores de joelho, em ambos os membros, no M2 e M3 foram superiores aos observados em M1 e M4. O PT dos extensores de joelho em M1 foi significantemente inferior aos demais momentos do estudo (M2, M3 e M4), em ambos os membros. A RFE, em ambos os membros, foi inferior em M1 quando comparado a M2 e M3. A comparação da RFE entre os membros não revelou diferenças significantes em nenhum dos momentos do estudo (M1, M2, M3 e M4). Os resultados encontrados na presente investigação indicaram existência de alterações na magnitude da RFE, porém dentro da normalidade, e, manutenção da proporcionalidade entre os membros ao longo do MP. Esses resultados sugerem que não existem períodos sensíveis para a ocorrência de lesões em virtude de desequilíbrios musculares ao longo do MP em jogadores de futebol da categoria sub-20.
Resumo:
Alterações no equilíbrio corporal das pessoas idosas podem gerar quedas e incapacidades diminuindo sua expectativa de vida e conseqüentemente sua qualidade de vida. Programas de reabilitação vestibular auxiliam na prevenção de tais desfechos e devem ser considerados entre as estratégias de intervenção a serem desenvolvidas na atenção básica
Resumo:
In this work, we have studied the influence of the substrate surface condition on the roughness and the structure of the nanostructured DLC films deposited by High Density Plasma Chemical Vapor Deposition. Four methods were used to modify the silicon wafers surface before starting the deposition processes of the nanostructured DLC films: micro-diamond powder dispersion, micro-graphite powder dispersion, and roughness generation by wet chemical etching and roughness generation by plasma etching. The reference wafer was only submitted to a chemical cleaning. It was possible to see that the final roughness and the sp(3) hybridization degree strongly depend on the substrate surface conditions. The surface roughness was observed by AFM and SEM and the hybridization degree of the DLC films was analyzed by Raman Spectroscopy. In these samples, the final roughness and the sp(3) hybridization quantity depend strongly on the substrate surface condition. Thus, the effects of the substrate surface on the DLC film structure were confirmed. These phenomena can be explained by the fact that the locally higher surface energy and the sharp edges may induce local defects promoting the nanostructured characteristics in the DLC films. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
A simple method with a fast sample preparation procedure for total and inorganic mercury determinations in blood samples is proposed based on flow injection cold vapor inductively coupled plasma mass spectrometry (FI-CVICP-MS). Aliquots of whole blood (500 mL) are diluted 1 + 1 v/v with 10.0% v/v tetramethylammonium hydroxide (TMAH) solution, incubated for 3 h at room temperature and then further diluted 1 + 4 v/v with 2.0% v/v HCl. The inorganic Hg was released by online addition of L-cysteine and then reduced to elemental Hg by SnCl(2). On the other hand, total mercury was determined by on-line addition of KMnO(4) and then reduced to elemental Hg by NaBH(4). Samples were calibrated against matrix-matching. The method detection limit was found to be 0.80 mu g L(-1) and 0.08 mu g L(-1) for inorganic and total mercury, respectively. Sample throughput is 20 samples h(-1). The method accuracy is traceable to Standard Reference Material (SRM) 966 Toxic Metals in Bovine Blood from the National Institute of Standards and Technology (NIST). For additional validation purposes, human whole blood samples were analyzed by the proposed method and by an established CV AAS method, with no statistical difference between the two techniques at 95% confidence level on applying the t-test.
Resumo:
We report on a quantitative study of the growth process of 87Rb Bose-Einstein condensates. By continuous evaporative cooling we directly control the thermal cloud from which the condensate grows. We compare the experimental data with the results of a theoretical model based on quantum kinetic theory. We find quantitative agreement with theory for the situation of strong cooling, whereas in the weak cooling regime a distinctly different behavior is found in the experiment.
Resumo:
Coating anatase TiO2 onto three different particle supports, activated carbon (AC), gamma -alumina (Al2O3) and silica gel (SiO2), by chemical vapor deposition (CVD) was studied. The effect of the CVD synthesis conditions on the loading rate of anatase TiO2 was investigated. It was found that introducing water vapor during CVD or adsorbing water before CVD was crucial to obtain anatase TiO2 on the surface of the particle supports. The evaporation temperature of precursor, deposition temperature in the reactor, flow rate of carrier gas, and the length of coating time were also important parameters to obtain more uniform and repeatable TiO2 coating. High inflow precursor concentration, high CVD reactor temperature and long coating time tended to cause block problem. Coating TiO2 onto small particles by CVD involved both chemical vapor deposition and particle deposition. It was believed that the latter was the reason for the block problem. In addition, the mechanism of CVD process in this study included two parts, pyrolysis and hydrolysis, and one of them was dominant in the CVD process under different synthesis route. Among the three types of materials, silica gel, with higher surface hydroxyl groups and macropore surface area, was found to be the most efficient support in terms of both anatase TiO2 coating and photocatalytic reaction. (C) 2001 Elsevier Science B.V. All rights reserved.
Resumo:
This study compared ultrasonic chemical vapor deposition (CVD)-coated tip (CVDentus #8.1117-1; Clorovale Diamantes Ind. e Com. Ltda Epp, Sao Jose dos Campos, SP, Brazil) versus high-speed (#FG700L) and low-speed (#699) carbide burs for apicoectomy, evaluating the time required for resection and analyzing the root-end surfaces by scanning electron microscopy. Thirty extracted human premolars had the canals instrumented and obturated and were randomly assigned to 3 groups (n = 10), according to the instrument used for root-end resection. The time required for resection of the apical 2 mm of each root was recorded. The resected apical segments were dried, sputter coated with gold, and examined with a scanning electron microscope at X 350 magnification. A four-point (0-3) scoring system was used to evaluate the apical surface smoothness. The results were analyzed statistically by the Kruskal-Wallis test and two-by-two comparisons analyses were performed using the Miller test. The significance level was set at 5%. Root-end resection with the high-speed bur was significantly faster (p < 0.05) compared with the low-speed bur and CVD tip. The carbide burs produced significantly smoother root-end surfaces than the CVD tip (p < 0.05). The low-speed bur produced the smoothest root-end surfaces, whereas the roughest and most irregular root ends (p < 0.05) were obtained with the CVD tip. However, no statistically significant difference (p > 0.05) was found between the high- and low-speed burs regarding the surface roughness of the resected root ends (p > 0.05). In conclusion, under the tested conditions, ultrasonic root-end resection took a longer time and resulted in rougher surfaces compared with the use of carbide burs at both high and low speed. (J Endod 2009;35:265-268)
Resumo:
Recently there has been experimental and theoretical interest in cross-dispersion effects in rubidium vapor, which allows one beam of light to be guided by another. We present theoretical results which account for the complications created by the D line hyperfine structure of rubidium as well as the presence of the two major isotopes of rubidium. This allows the complex frequency dependence of the effects observed in our experiments to be understood and lays the foundation for future studies of nonlinear propagation.
Resumo:
A thermodynamic approach is developed in this paper to describe the behavior of a subcritical fluid in the neighborhood of vapor-liquid interface and close to a graphite surface. The fluid is modeled as a system of parallel molecular layers. The Helmholtz free energy of the fluid is expressed as the sum of the intrinsic Helmholtz free energies of separate layers and the potential energy of their mutual interactions calculated by the 10-4 potential. This Helmholtz free energy is described by an equation of state (such as the Bender or Peng-Robinson equation), which allows us a convenient means to obtain the intrinsic Helmholtz free energy of each molecular layer as a function of its two-dimensional density. All molecular layers of the bulk fluid are in mechanical equilibrium corresponding to the minimum of the total potential energy. In the case of adsorption the external potential exerted by the graphite layers is added to the free energy. The state of the interface zone between the liquid and the vapor phases or the state of the adsorbed phase is determined by the minimum of the grand potential. In the case of phase equilibrium the approach leads to the distribution of density and pressure over the transition zone. The interrelation between the collision diameter and the potential well depth was determined by the surface tension. It was shown that the distance between neighboring molecular layers substantially changes in the vapor-liquid transition zone and in the adsorbed phase with loading. The approach is considered in this paper for the case of adsorption of argon and nitrogen on carbon black. In both cases an excellent agreement with the experimental data was achieved without additional assumptions and fitting parameters, except for the fluid-solid potential well depth. The approach has far-reaching consequences and can be readily extended to the model of adsorption in slit pores of carbonaceous materials and to the analysis of multicomponent adsorption systems. (C) 2002 Elsevier Science (USA).
Resumo:
Poly(tetrafluoroethylene-co-perfluoropropyI vinyl ether), PFA, was grafted with styrene from the vapor phase using a simultaneous radiation grafting method. The graft yields were measured as a function of the dose and dose rate and were found to be initially linearly dependent on the dose and independent of the dose rate up to dose rates of similar to3 kGy/h. However, at a dose rate of 6.2 kGy/h, the slope of the yield-grafting time plot decreased. Raman depth profiles of the grafts showed that the polystyrene concentrations were greatest near the surface of the grafted samples and decreased with depth. The maximum penetration depth of the graft depended on the radiation dose for a fixed dose rate. Fmoc-Rink loading tests showed that the grafts displayed superior loading compared to grafts prepared from bulk styrene or from styrene solutions other than methanol.
Resumo:
Os métodos de análise de estruturas de contenção de solo reforçado sob condições de trabalho, em geral, desconsideram a contribuição da face para o equilíbrio da estrutura. Visando estudar a influência do peso específico da face e das propriedades relacionadas à rigidez da mesma sobre o desempenho das estruturas de solo reforçado, são realizadas simulações numéricas de diversas estruturas, utilizando a versão de dupla precisão do programa CRISP92-SC. Avalia-se, também, o emprego de diferentes tipos de elementos para a representação da face. Verifica-se que a face rígida impõe redução significativa das solicitações máximas de tração nos reforços e dos deslocamentos das estruturas de solo reforçado. A influência do peso específico da face sobre a estabilidade interna dos maciços reforçados mostrase desprezível e constata-se que a rigidez à flexão e a rigidez axial da face, função da sua geometria e do seu módulo de Young, são parâmetros influentes no comportamento das estruturas de contenção de solo reforçado. As variações da tração no reforço e da resultante de força cortante na face, em decorrência do enrijecimento da face, são analisadas e propõe-se uma relação entre elas. Quanto à forma de representação de uma face com rigidez expressiva, na simulação de uma estrutura de solo reforçado com o CRISP92-SC, é observado que a representação da face, seja por elementos de viga, seja por elementos quadriláteros, não altera os resultados da análise.
Resumo:
O sistema vestibular é referencial absoluto na manutenção do equilíbrio. Seu déficit funcional pelo envelhecimento resulta em alterações no equilíbrio e aumento na possibilidade de queda. OBJETIVO: Verificar se a abordagem terapêutica específica para o sistema vestibular gera aprendizado motor e contribui para a melhora do equilíbrio e a diminuição na possibilidade de queda. FORMA DE ESTUDO: Clínico prospectivo. MATERIAL E MÉTODO: Quinze mulheres, entre 60 e 69 anos, média = 64,8 anos (±2,95), residentes no município de Barra Mansa - RJ, foram submetidas aos exercícios de Cawthorne e Cooksey, durante nove semanas, três vezes por semana, durante sessenta minutos, no período de março a junho de 2003. Avaliou-se o equilíbrio pela Escala do Equilíbrio de Berg (EEB), cujos escores determinaram a possibilidade de queda (PQ). Analisaram-se os resultados pelos testes T-Student e Wilcoxon. O nível de significância foi p<0,05. RESULTADOS: Na comparação dos resultados pré e pós-intervenção, observou-se diferença significativa (p<0,05), com melhora nos escores na EEB e diminuição no índice da PQ. CONCLUSÃO: Os exercícios de Cawthorne e Cooksey promoveram aprendizado motor nesta amostra e podem ser aplicados como medida preventiva e de tratamento nas alterações do equilíbrio no envelhecimento.
Resumo:
Com o passar dos anos, o organismo humano passa por um processo natural de envelhecimento, gerando modificações funcionais e estruturais no organismo. As vias responsáveis pelo equilíbrio corporal também sofrem com o processo do envelhecimento, gerando grande impacto para os idosos. OBJETIVO: Assim, o presente trabalho objetiva estudar a função vestibular de idosos em função das queixas de tontura, zumbido e dificuldade auditiva. FORMA DE ESTUDO: Coorte transversal. MATERIAL E MÉTODO: Foram avaliados 80 idosos de dois grupos distintos: Grupo A - composto por 38 mulheres e dois homens pertencentes a um grupo de terceira idade; e Grupo B: composto por 35 mulheres e cinco homens com queixas efetivas de alterações do equilíbrio corporal. RESULTADO: Os idosos foram submetidos à anamnese, sendo investigados prioritariamente aspectos relativos a tontura, zumbido e dificuldade auditiva; e à avaliação vestibular, realizada por intermédio do sistema computadorizado de vecto-eletronistagmografia SCV 5.0. Os resultados demonstram uma diferença estatisticamente significante entre os grupos, no que diz respeito às queixas de tontura e zumbido, as quais prevaleceram nos indivíduos do grupo B. Na hipótese diagnóstica predominante à vecto-eletronistagmografia computadorizada constatou-se que a maioria dos idosos apresentou diagnóstico normal, porém verificou-se a prevalência de alterações vestibulares nos idosos como Síndrome vestibular periférica deficitária e Síndrome vestibular periférica irritativa. Não se observou sinais patognomônicos de alterações centrais ao exame vestibular. CONCLUSÃO: Concluiu-se que as alterações vestibulares à Vecto-eletronistagmografia, em função das queixas de tontura, zumbido e dificuldade auditiva, são numericamente semelhantes no Grupo de Terceira Idade e no Grupo de idosos com queixas efetivas de alterações do equilíbrio corporal.
Resumo:
Tarefas do dia-a-dia podem ser muito desafiadoras para o equilíbrio do idoso. OBJETIVO: Verificar a associação entre equilíbrio funcional, avaliado pela Berg Balance Scale (BBS) e os dados sociodemográficos, clínicos e de mobilidade (Timed up and go test - TUGT, Dynamic Gait Index - DGI) em idosos vestibulopatas crônicos. MATERIAL E MÉTODO: Estudo de casos com 120 idosos com diagnóstico de disfunção vestibular crônica. Foram utilizados os testes de Mann-Whitney, Kruskal-Wallis seguido do teste de Dunn e Coeficiente de Correlação de Spearman. RESULTADOS: Ocorreram associações =-0,354; e correlações significantes entre a pontuação total da BBS e idade (p<0,001), faixa etária (p<0,001), número de doenças (p=0,030), número de =-0,287; p=0,001), número de medicamentos (p=0,014), número de doenças (=-0,274; p=0,002), quedas recorrentes (p=0,010), tendência a medicamentos (quedas (p=0,002), diagnóstico topográfico de vestibulopatia central (p<0,001) =-0,709; periodicidade da tontura (p=0,039), TUGT (<0,001) e DGI =-0,748; p(<0,001). CONCLUSÕES: O equilíbrio funcional de idosos vestibulopatas crônicos avaliados à BBS é mais comprometido quando associado ao avançar da idade, faixa etária mais idosa (80 anos ou mais), aumento do número de doenças, presença de cinco ou mais doenças, polifarmacoterapia, quedas recorrentes, tendência a quedas, vestibulopatia central, tontura diária, comprometimento da mobilidade e marcha.