966 resultados para dynamic range
A real-time quantitative assay for hepatitis B DNA virus (HBV) developed to detect all HBV genotypes
Resumo:
Hepatitis B virus (HBV) is a major cause of chronic liver disease worldwide. Besides genotype, quantitative analysis of HBV infection is extensively used for monitoring disease progression and treatment. Affordable viral load monitoring is desirable in resource-limited settings and it has been already shown to be useful in developing countries for other viruses such as Hepatitis C virus (HCV) and HIV. In this paper, we describe the validation of a real-time PCR assay for HBV DNA quantification with TaqMan chemistry and MGB probes. Primers and probes were designed using an alignment of sequences from all HBV genotypes in order to equally amplify all of them. The assay is internally controlled and was standardized with an international HBV panel. Its efficacy was evaluated comparing the results with two other methods: Versant HBV DNA Assay 3.0 (bDNA, Siemens, NY, USA) and another real-time PCR from a reference laboratory. Intra-assay and inter-assay reproducibilities were determined and the mean of CV values obtained were 0.12 and 0.09, respectively. The assay was validated with a broad dynamic range and is efficient for amplifying all HBV genotypes, providing a good option to quantify HBV DNA as a routine procedure, with a cheap and reliable protocol.
Resumo:
Introduction Molecular biology procedures to detect, genotype and quantify hepatitis C virus (HCV) RNA in clinical samples have been extensively described. Routine commercial methods for each specific purpose (detection, quantification and genotyping) are also available, all of which are typically based on polymerase chain reaction (PCR) targeting the HCV 5′ untranslated region (5′UTR). This study was performed to develop and validate a complete serial laboratory assay that combines real-time nested reverse transcription-polymerase chain reaction (RT-PCR) and restriction fragment length polymorphism (RFLP) techniques for the complete molecular analysis of HCV (detection, genotyping and viral load) in clinical samples. Methods Published HCV sequences were compared to select specific primers, probe and restriction enzyme sites. An original real-time nested RT-PCR-RFLP assay was then developed and validated to detect, genotype and quantify HCV in plasma samples. Results The real-time nested RT-PCR data were linear and reproducible for HCV analysis in clinical samples. High correlations (> 0.97) were observed between samples with different viral loads and the corresponding read cycle (Ct - Cycle threshold), and this part of the assay had a wide dynamic range of analysis. Additionally, HCV genotypes 1, 2 and 3 were successfully distinguished using the RFLP method. Conclusions A complete serial molecular assay was developed and validated for HCV detection, quantification and genotyping.
Resumo:
Activation of the dorsomedial nucleus of the hypothalamus (DMH) by galanin (GAL) induces behavioural hyperalgesia. Since DMH neurones do not project directly to the spinal cord, we hypothesized that the medullary dorsal reticular nucleus (DRt), a pronociceptive region projecting to the spinal dorsal horn (SDH) and/or the serotoninergic raphe-spinal pathway acting on the spinal 5-HT3 receptor (5HT3R) could relay descending nociceptive facilitation induced by GAL in the DMH. Heat-evoked paw-withdrawal latency (PWL) and activity of SDH neurones were assessed in monoarthritic (ARTH) and control (SHAM) animals after pharmacological manipulations of the DMH, DRt and spinal cord. The results showed that GAL in the DMH and glutamate in the DRt lead to behavioural hyperalgesia in both SHAM and ARTH animals, which is accompanied particularly by an increase in heat-evoked responses of wide-dynamic range neurons, a group of nociceptive SDH neurones. Facilitation of pain behaviour induced by GAL in the DMH was reversed by lidocaine in the DRt and by ondansetron, a 5HT3R antagonist, in the spinal cord. However, the hyperalgesia induced by glutamate in the DRt was not blocked by spinal ondansetron. In addition, in ARTH but not SHAM animals PWL was increased after lidocaine in the DRt and ondansetron in the spinal cord. Our data demonstrate that GAL in the DMH activates two independent descending facilitatory pathways: (i) one relays in the DRt and (ii) the other one involves 5-HT neurones acting on spinal 5HT3Rs. In experimental ARTH, the tonic pain-facilitatory action is increased in both of these descending pathways.
Resumo:
A generic optical biosensing strategy was developed that relies on the absorbance enhancement phenomenon occurring in a multiple scattering matrix. Experimentally, inserts made of glass fiber membrane were placed into microplate wells in order to significantly lengthen the trajectory of the incident light through the sample and therefore increase the corresponding absorbance. Enhancement factor was calculated by comparing the absorbance values measured for a given amount of dye with and without the absorbance-enhancing inserts in the wells. Moreover, the dilution of dye in solutions with different refractive indices (RI) clearly revealed that the enhancement factor increased with the ΔRI between the membrane and the surrounding medium, reaching a maximum value (EF>25) when the membranes were dried. On this basis, two H2O2-biosensing systems were developed based on the biofunctionalization of the glass fiber inserts either with cytochrome c or horseradish peroxidase (HRP) and the analytical performances were systematically compared with the corresponding bioassay in solution. The efficiency of the absorbance-enhancement approach was particularly clear in the case of the cytochrome c-based biosensor with a sensitivity gain of 40 folds and wider dynamic range. Therefore, the developed strategy represents a promising way to convert standard colorimetric bioassays into optical biosensors with improved sensitivity.
Resumo:
Microarray transcript profiling and RNA interference are two new technologies crucial for large-scale gene function studies in multicellular eukaryotes. Both rely on sequence-specific hybridization between complementary nucleic acid strands, inciting us to create a collection of gene-specific sequence tags (GSTs) representing at least 21,500 Arabidopsis genes and which are compatible with both approaches. The GSTs were carefully selected to ensure that each of them shared no significant similarity with any other region in the Arabidopsis genome. They were synthesized by PCR amplification from genomic DNA. Spotted microarrays fabricated from the GSTs show good dynamic range, specificity, and sensitivity in transcript profiling experiments. The GSTs have also been transferred to bacterial plasmid vectors via recombinational cloning protocols. These cloned GSTs constitute the ideal starting point for a variety of functional approaches, including reverse genetics. We have subcloned GSTs on a large scale into vectors designed for gene silencing in plant cells. We show that in planta expression of GST hairpin RNA results in the expected phenotypes in silenced Arabidopsis lines. These versatile GST resources provide novel and powerful tools for functional genomics.
Resumo:
The misuse of human growth hormone (hGH) in sport is deemed to be unethical and dangerous because of various adverse effects. Thus, it has been added to the International Olympic Committee list of banned substances. Until now, the very low concentration of hGH in the urine made its measurement difficult using classical methodology. Indeed, for routine diagnosis, only plasma measurements were available. However, unlike blood samples, urine is generally provided in abundant quantities and is, at present, the only body fluid allowed to be analysed in sport doping controls. A recently developed enzyme-linked immunosorbent assay (Norditest) makes it now possible, without any extraction, to measure urinary hGH (u-hGH) in a dynamic range of 2-50 ng hGH/l. In our protocol, untreated and treated non-athlete volunteers were followed. Some of them received therapeutical doses of recombinant hGH (Norditropin) for one week either intramuscularly (three increasing doses) or subcutaneously (12 i.u. every day). The u-hGH excretion after treatment showed dramatic increases of 50-100 times the basal values and returned to almost the mean normal level after 24 h. u-hGH was also measured in samples provided by the anti-doping controls at major and minor competitions. Depending on the type of efforts made during the competition, the hGH concentration in urine was dramatically increased. Insulin-like growth factor binding proteins and beta 2-microglobulins in urine and/or in blood could be necessary for the correct investigation of any hGH doping test procedure.
Resumo:
Nucleic acid amplification techniques are commonly used currently to diagnose viral diseases and manage patients with this kind of illnesses. These techniques have had a rapid but unconventional route of development during the last 30 years, with the discovery and introduction of several assays in clinical diagnosis. The increase in the number of commercially available methods has facilitated the use of this technology in the majority of laboratories worldwide. This technology has reduced the use of some other techniques such as viral culture based methods and serological assays in the clinical virology laboratory. Moreover, nucleic acid amplification techniques are now the methods of reference and also the most useful assays for the diagnosis in several diseases. The introduction of these techniques and their automation provides new opportunities for the clinical laboratory to affect patient care. The main objectives in performing nucleic acid tests in this field are to provide timely results useful for high-quality patient care at a reasonable cost, because rapid results are associated with improvements in patients care. The use of amplification techniques such as polymerase chain reaction, real-time polymerase chain reaction or nucleic acid sequence-based amplification for virus detection, genotyping and quantification have some advantages like high sensitivity and reproducibility, as well as a broad dynamic range. This review is an up-to-date of the main nucleic acid techniques and their clinical applications, and special challenges and opportunities that these techniques currently provide for the clinical virology laboratory.
Resumo:
Hepatitis B virus (HBV) and Hepatitis C virus (HCV) infections pose major public health problems because of their prevalence worldwide. Consequently, screening for these infections is an important part of routine laboratory activity. Serological and molecular markers are key elements in diagnosis, prognosis and treatment monitoring for HBV and HCV infections. Today, automated chemiluminescence immunoassay (CLIA) analyzers are widely used for virological diagnosis, particularly in high-volume clinical laboratories. Molecular biology techniques are routinely used to detect and quantify viral genomes as well as to analyze their sequence; in order to determine their genotype and detect resistance to antiviral drugs. Real-time PCR, which provides high sensitivity and a broad dynamic range, has gradually replaced other signal and target amplification technologies for the quantification and detection of nucleic acid. The next-generation DNA sequencing techniques are still restricted to research laboratories.The serological and molecular marker methods available for HBV and HCV are discussed in this article, along with their utility and limitations for use in Chronic Hepatitis B (CHB) diagnosis and monitoring.
Resumo:
Tone Mapping is the problem of compressing the range of a High-Dynamic Range image so that it can be displayed in a Low-Dynamic Range screen, without losing or introducing novel details: The final image should produce in the observer a sensation as close as possible to the perception produced by the real-world scene. We propose a tone mapping operator with two stages. The first stage is a global method that implements visual adaptation, based on experiments on human perception, in particular we point out the importance of cone saturation. The second stage performs local contrast enhancement, based on a variational model inspired by color vision phenomenology. We evaluate this method with a metric validated by psychophysical experiments and, in terms of this metric, our method compares very well with the state of the art.
Resumo:
BACKGROUND: HIV-1 RNA viral load is a key parameter for reliable treatment monitoring of HIV-1 infection. Accurate HIV-1 RNA quantitation can be impaired by primer and probe sequence polymorphisms as a result of tremendous genetic diversity and ongoing evolution of HIV-1. A novel dual HIV-1 target amplification approach was realized in the quantitative COBAS AmpliPrep/COBAS TaqMan HIV-1 Test, v2.0 (HIV-1 TaqMan test v2.0) to cope with the high genetic diversity of the virus. OBJECTIVES AND STUDY DESIGN: The performance of the new assay was evaluated for sensitivity, dynamic range, precision, subtype inclusivity, diagnostic and analytical specificity, interfering substances, and correlation with the COBAS AmpliPrep/COBAS TaqMan HIV-1 (HIV-1 TaqMan test v1.0) predecessor test in patients specimens. RESULTS: The new assay demonstrated a sensitivity of 20 copies/mL, a linear measuring range of 20-10,000,000 copies/mL, with a lower limit of quantitation of 20 copies/mL. HIV-1 Group M subtypes and HIV-1 Group O were quantified within +/-0.3 log(10) of the assigned titers. Specificity was 100% in 660 tested specimens, no cross reactivity was found for 15 pathogens nor any interference for endogenous substances or 29 drugs. Good comparability with the predecessor assay was demonstrated in 82 positive patient samples. In selected clinical samples 35/66 specimens were found underquantitated in the predecessor assay; all were quantitated correctly in the new assay. CONCLUSIONS: The dual-target approach for the HIV-1 TaqMan test v2.0 enables superior HIV-1 Group M subtype coverage including HIV-1 Group O detection. Correct quantitation of specimens underquantitated in the HIV-1 TaqMan test v1.0 test was demonstrated.
Resumo:
Supernatants from cell cultures (also called conditioned media, CMs) are commonly analyzed to study the pool of secreted proteins (secretome). To reduce the exogenous protein background, serum-free media are often used to obtain CMs. Serum deprivation, however, can severely affect cell viability and phenotype, including protein secretion. We present a strategy to analyze the proteins secreted by cells in fetal bovine serum-containing CMs, which combines the advantage of metabolic labeling and protein concentration linearization techniques. Incubation of CMs with a hexapeptide ligand library was used to reduce the dynamic range of the samples and led to the identification of 3 times more proteins than in untreated CM samples. Labeling with a deuterated amino acid was used to distinguish between cellular proteins and homologous bovine proteins contained in the medium. Application of the strategy to two breast cancer cell lines led to the identification of proteins secreted in different amounts and which could correlate with their varying degree of aggressiveness. Selected reaction monitoring (SRM)-based quantitation of three proteins of interest in the crude samples yielded data in good agreement with the results from concentration-equalized samples.
Resumo:
A bidimensional array based on single-photon avalanche diodes for triggered imaging systems is presented. The diodes are operated in the gated mode of acquisition to reduce the probability to detect noise counts interfering with photon arrival events. In addition, low reverse bias overvoltages are used to lessen the dark count rate. Experimental results demonstrate that the prototype fabricated with a standard HV-CMOS process gets rid of afterpulses and offers a reduced dark count probability by applying the proposed modes of operation. The detector exhibits a dynamic range of 15 bits with short gated"on" periods of 10ns and a reverse bias overvoltage of 1.0V.
Resumo:
The gated operation is proposed as an effective method to reduce the noise in pixel detectors based on Geiger mode avalanche photodiodes. A prototype with the sensor and the front-end electronics monolithically integrated has been fabricated with a conventional HV-CMOS process. Experimental results demonstrate the increase of the dynamic range of the sensor by applying this technique.
Resumo:
Identification and relative quantification of hundreds to thousands of proteins within complex biological samples have become realistic with the emergence of stable isotope labeling in combination with high throughput mass spectrometry. However, all current chemical approaches target a single amino acid functionality (most often lysine or cysteine) despite the fact that addressing two or more amino acid side chains would drastically increase quantifiable information as shown by in silico analysis in this study. Although the combination of existing approaches, e.g. ICAT with isotope-coded protein labeling, is analytically feasible, it implies high costs, and the combined application of two different chemistries (kits) may not be straightforward. Therefore, we describe here the development and validation of a new stable isotope-based quantitative proteomics approach, termed aniline benzoic acid labeling (ANIBAL), using a twin chemistry approach targeting two frequent amino acid functionalities, the carboxylic and amino groups. Two simple and inexpensive reagents, aniline and benzoic acid, in their (12)C and (13)C form with convenient mass peak spacing (6 Da) and without chromatographic discrimination or modification in fragmentation behavior, are used to modify carboxylic and amino groups at the protein level, resulting in an identical peptide bond-linked benzoyl modification for both reactions. The ANIBAL chemistry is simple and straightforward and is the first method that uses a (13)C-reagent for a general stable isotope labeling approach of carboxylic groups. In silico as well as in vitro analyses clearly revealed the increase in available quantifiable information using such a twin approach. ANIBAL was validated by means of model peptides and proteins with regard to the quality of the chemistry as well as the ionization behavior of the derivatized peptides. A milk fraction was used for dynamic range assessment of protein quantification, and a bacterial lysate was used for the evaluation of relative protein quantification in a complex sample in two different biological states
Resumo:
At high magnetic field strengths (≥ 3T), the radiofrequency wavelength used in MRI is of the same order of magnitude of (or smaller than) the typical sample size, making transmit magnetic field (B1+) inhomogeneities more prominent. Methods such as radiofrequency-shimming and transmit SENSE have been proposed to mitigate these undesirable effects. A prerequisite for such approaches is an accurate and rapid characterization of the B1+ field in the organ of interest. In this work, a new phase-sensitive three-dimensional B1+-mapping technique is introduced that allows the acquisition of a 64 × 64 × 8 B1+-map in ≈ 20 s, yielding an accurate mapping of the relative B1+ with a 10-fold dynamic range (0.2-2 times the nominal B1+). Moreover, the predominant use of low flip angle excitations in the presented sequence minimizes specific absorption rate, which is an important asset for in vivo B1+-shimming procedures at high magnetic fields. The proposed methodology was validated in phantom experiments and demonstrated good results in phantom and human B1+-shimming using an 8-channel transmit-receive array.